Search NASA⌕ Search

SEARCH · Search NASA

Results for “duct system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Modeling of Transport Processes in Liquid-Metal Fusion Blankets: Past, Present, and Future

The successful development of robust breeding blanket systems will strongly rely on computational tools for predicting the complex behavior of the electrically conducting liquid-metal (LM) breeder flowing in the complex-shaped blanket ducts in the presence of a strong plasma-confining magnetic field, volumetric heating, and tritium generation. Associated transport processes involve magnetohydrodynamic (MHD) flows, heat transfer, corrosion, and tritium transport. This paper is an overview of past and present efforts in the development, application, and verification and validation (V&V) of such computational tools. As a result of the ongoing campaign on V&V of computer codes for LM blankets, the international fusion community has identified several candidates that promise to become real blanket design and analysis tools in the near future. Among them are HIMAG, MHD-UCAS, COMSOL Multiphysics, ANSYS FLUENT, ANSYS CFX, and OpenFOAM. The progress, over the last decade, in the application of such codes in blanket studies is tremendous. This is illustrated with two examples for a dual-coolant lead-lithium (DCLL) blanket: (1) integrated computer modeling for the recently designed DCLL blanket in the United States and (2) application of the code MHD-UCAS to the analysis of PbLi flows and heat transfer in a generic DCLL blanket prototype at high Hartmann (Ha ~ 10 4 ) and Grashof numbers (Gr ~ 10 12 ). Here, this paper also presents an approach to the development of a new integrated computational tool called the virtual dual-coolant lead-lithium (VDCLL) blanket, which elaborates the existing U.S. MHD code HIMAG.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of the indoor near-field aerosol transmission in a model commercial office building

To evaluate the exposure potential of infectious aerosols containing SARS-CoV-2 in an office building setting, synthetic test aerosols were used to experimental study airborne particle transmission in a multizone small office test building at the Oak Ridge National Laboratory. Nine measurement points in a single zone using active aerosol impactors report that the coefficient of variation of the time-averaged concentration is <10% in two campaigns and < 15% in one campaign, so a nearly well-mixed condition was noted. To understand the effect of HVAC system operation on the dynamic concentration of aerosols in office spaces, an aerosol transport model that includes factors such as outside air (OA) ratio, filtration, return air fraction, transport loss in air ducts, and particle deposition has been developed. The results of model fitting demonstrate strong agreement with experimental data. Overall, our investigation finds the return air fraction effects outweigh other mechanisms for the aerosol recirculation in this study, and the impact of air change rate (ACR) is more important than the small particle deposition for aerosol removal. Because ACR dominates the aerosol transport, the full model can be simplified to just one factor, the ACR, while maintaining an acceptable representation of the experimental data.

60 APPLIED LIFE SCIENCES↗

Assembly Bowing Reactivity Calculation Methodology Applied to Lead Fast Reactor

Ducted assemblies bow during operation due to power and temperature gradients which can be influenced by operating flow rates. For fast spectrum cores using ducted assemblies, the bowing behavior follows that of the duct and because there are gaps between the ducts, the bowing can result in compaction or expansion of the active core. This local displacement can have a positive or negative impact and knowing the net effect during transients is important for system reactivity control. Keeping the net bowing reactivity worth low is possible with attentive placement of load pads above the active core and selecting load pad gap thicknesses that result in a desired behavior at standard operating conditions. This paper considers a Lead Fast Reactor (LFR) concept fueled by HALEU UO2 developed by Westinghouse Electric Company (WEC) and applies a workflow of Argonne-developed codes to estimate the core bowing reactivity worth. Using orifice flow rates grouped by assembly type, the net reactivity impact due to core assembly bowing for the LFR was found to be small and in line with other liquid metal fast reactors: +29/+32/+35 pcm, or about +$0.049/+$0.055/+$0.059, for BOEC/MOEC/EOEC, respectively.

bowing reactivity↗

Numerical Investigation of Enhanced Dehumidification Processes By Using Dielectrophoresis Principles in Moist Airflows

Dispersed particle-laden flows are encountered in many building and industrial applications, such as flow in a fluidized bed, hydrocarbon transportation in pipelines, and the fouling of air-cooled heat exchangers (Kuruneru et al., 2016; Ray et al., 2019; Wang et al., 2019). Computational fluid dynamic (CFD) models have been developed in recent years to depict particle-fluid and particle-particle interactions in laminar or turbulent flows with increasing accuracy and stability. One particular particle-laden system of interest for moisture control is electrically-enhanced condensation in air and water droplet flows. Electrically-enhanced condensation consists of the use of highly charged water droplets injected in the moist air. The droplets become electric seeds that attract polar water vapor molecules to their surfaces and promote condensation. The nucleation and growth of the charged droplets deplete the vapor phase near a droplet, which is compensated for by the dielectrophoresis flow and diffusion. Dielectrophoresis flow involves surrounding vapor at a distance of about 10 to 100 nm for droplets charged by an electrospray compared to ~2 nm for a single electron charge in a droplet. As the vapor molecules collapse on the surface of the droplets, their initial electrical charge decreases with time due to the neutralization of the ions. While the physics of this phenomena is well known, engineering models for predicting the condensation rates are not available. This work computationally investigates dehumidification of moist airflow in a converging rectangular duct. The objective is to develop an engineering model that predicts water vapor condensation by employing dielectrophoresis principles. We construct a Computational Fluid Dynamics (CFD) model of the duct with electrically-enhanced condensation. The model is implemented in the open-source software OpenFOAM. We utilize the Multi-Phase Particle-In-Cell (MP-PIC) method coupled with a Population Balance Equation (PBE) approach to simulate the particle-laden system. This methodology is an Eulerian-Lagrangian approach used to simulate the droplets' behavior in the humid air. The MP-PIC approach (Andrews and O'Rourke, 1996) mitigates the computational cost by parceling several fundamental particles with similar properties (such as types, sizes, and temperature) into one computational particle. Thus, the billions of particles can be substituted by millions of computational particles without significant loss of information. The PBE was considered with the Lagrangian frame to combine the particle distribution function used in MP-PIC (Kim et al., 2020). This approach preserves mass and energy conservation between the phases in the Eulerian and Lagrangian structures. The PBE in this procedure was directly linked to the discrete parcels, making the simulation of the particle distribution computationally efficient and robust. The MP-PIC-PBE approach used in the present work was applied to the dehumidification of air. Water droplets were injected in the air stream and forced to grow according to experimentally derived correlation. The experiments were conducted on a converging duct with the same geometry and boundary conditions used to build the CFD model. This approach enabled us to approximate the effect of dielectrophoresis phenomena on the droplet and air interface. This presentation will discuss the details of the new CFD model built for the duct, the implementation of the model in OpenFOAM CFD programming language, and the experimental validation of the newly developed model. The results revealed a moderate yet measurable increase in droplet diameter due to water vapor condensation at the vapor-liquid interface of the electrically charged droplets' surface. The seed water droplet particles grew in size by capturing the water vapor in the surrounding air. The OpenFOAM model predicted reductions of humidity in the air from 5 to 10 percent.

Yel Mahi, Maliha↗

Ducted Assembly Steady-State Heat Transfer Software (DASSH): Theory Manual

The Ducted Assembly Steady-State Heat transfer software (DASSH) is being developed at Argonne National Laboratory to obtain a steady-state thermal fluids result for the coolant flow and temperature distribution in a hexagonally gridded reactor core with ducted assemblies. In DASSH, each assembly is assumed to contain a hexagonal bundle of wire-wrapped pins. DASSH divides the coolant in the pin bundle into subchannels on which it applies energy balances to determine coolant and duct temperatures. DASSH offers multiple models for inter assembly heat transfer and features the ability to calculate pin temperatures. This document describes the models and equations implemented in DASSH. It includes a description of the geometric system to which the models are applied and a derivation of the subchannel energy balance formulation is presented. It also reviews the available correlations and provides an overview of the process by which power distributions are generated. Finally, it covers the code execution procedure, discussing the main code objects and their interactions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SO3/H2SO4 continuous real-time sensor demonstration at a power plant

We present results from field testing of a new, innovative sensor developed to measure SO3/H2SO4 continuously and in real time at a coal-fired power plant. The system utilizes the sensitivity, specificity, and real-time capabilities of mid-infrared (Mid-IR) laser-based sensor technology, along with a heated, close-coupled cell mounted directly to a power plant duct. Measurements were made by the laser sensor over a 2-day period and compared to results from the accepted method, EPA 8A, which requires a 30-minute collection, labor intensive processing, and off-site analysis at a lab. In contrast to the condensation method, the laser sensor continuously samples flue gas and reports measurements of the concentration of SO3/H2SO4, SO2 ever second with unattended operation. This initial demonstration proved the sensor concept and paves the way for its use for optimizing sorbent injection used to neutralize SO3/H2SO4. Optimized sorbent injection will enable significant cost savings associated with efforts to mitigate the presence and effects of SO3/H2SO4 such as “Blue Plume”, air heater fouling, and duct corrosion. In particular, the real-time, actionable information will enable better control of additive injection in flex conditions and variable fuels.

20 FOSSIL-FUELED POWER PLANTS↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

A Field and Laboratory Study to Characterize Fault Prevalence in Residential Comfort Systems

This report describes a project whose goal was to determine the prevalence of residential comfort system faults. The focus is on air conditioners and heat pumps, and on key faults that can occur during installation and have significant impacts on performance: (1) incorrect refrigerant charge level (undercharge or overcharge); (2) indoor coil airflow rate; (3) liquid line restrictions; (4) non-condensable gas in the refrigerant; and (5) duct leakage. In addition to quantifying fault prevalence, we collected metadata that could be studied to determine whether there are correlations that suggest drivers of fault prevalence, such as regional variations in practice, economic factors, climatic impacts, and others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developments and Challenges in the Design of the ITER DRGA

We report the ITER Diagnostic Residual Gas Analyzer (DRGA) will measure the distribution of gas species, i.e., deuterium (D), tritium (T), and impurities, in the divertor exhaust stream and in the plasma periphery, with time resolution relevant to fusion plasma–wall particle dynamics. The uniqueness of the DRGA, over previous implementations of plasma dynamics residual gas analysis, is an integrated approach, combining mass and low-temperature plasma-activated optical spectroscopy, in a differentially pumped analysis station. A further unique feature of the ITER divertor-specific DRGA is an ~8-m separation of the analysis station from the sampled pumping duct, while still maintaining a ~1-s response time for hydrogen isotopic concentrations. ITER DRGA final design activities are strongly benefiting from testing of prototypical DRGA components and methods on present fusion devices, most currently on JET and W7-X. DRGA systems are implemented on both these devices and include sensors (and pumping methods) that are directly relevant to the ITER DRGA design. The recent JET-DTE2 campaign has provided the first experience on operating the combined ITER DRGA sensors with D-T plasmas. While enhancing system design for ITER, this experience on operating devices has also revealed additional engineering challenges, which further guide the continuing final design project. Meanwhile, the recent determination that the ITER DRGA, with slight optimization, will resolve the helium isotopes well enough to support an ITER pre-DT, He-3-based heating scheme, has greatly increased ITER Research Program interest in the DRGA and its implementation well ahead of the DT phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated fault detection of residential air-conditioning systems using thermostat drive cycles

Residential air conditioning equipment comprises a significant portion of the total energy consumption of a home. Unfortunately, air-conditioning systems can be susceptible to faulty operation either from installation errors or faults that accrue over the equipment’s lifetime. This paper presents a novel automated fault detection algorithm for residential air-conditioning systems that can alert the homeowner of the presence of these faults. The proposed algorithm utilizes only the home’s thermostat and outside air temperature to perform automated fault detection over the course of the equipment’s lifetime, including immediately after installation. The algorithm uses an extended Kalman filter approach to identify a three-resistor, two-capacitor (3R2C) electrical equivalent thermodynamic model. The identified 3R2C model is used to predict cooling times during a testing period comprising of a series of thermostat drive-cycle experiments. We tested the algorithm on an EnergyPlus™ model of a typical residential building in Orlando, Florida. Duct faults, indoor airflow faults, and refrigerant undercharge faults were introduced into the building model one at a time. The algorithm was able to accurately determine duct-leak faults, 40% airflow faults, 40% undercharge faults, and no-fault cases with an accuracy of 70%, 77%, 82%, and 87%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerosol and Gas Transport in Ventilation Ducts in Nonreactor Nuclear Facilities

This document summarizes outcomes and finding in FY 2022 from a project sponsored by the Nuclear Safety Research and Development Program, which is managed by the Office of Nuclear Safety, within the Office of Environment, Health, Safety and Security. Literature survey and data collection are discussed in Sections 1 and 2, respectively. Numerical modeling of particulate transports in ventilation systems performed for standard geometries and a full-scale ventilation system is described in Section 3, and Section 4 summarizes the development of proof-of-concept sensors featuring ultrasound technology for particle deposition removal. Conclusions and recommendations are outlined in Section 5.

42 ENGINEERING↗

Multiphysics Demonstration of Temperature-Driven Assembly Bowing in SFRs using MOOSE-Based Codes

Core bowing is an important passive safety mechanism in liquid metal cooled fast reactors. When the core restraint system is properly designed, temperature and flux gradients influence assemblies in the core to bow into less reactive configurations during accident scenarios, resulting in negative reactivity feedback. Prediction of core bowing involves complex interplay of radiation transport, impacts of fluid flow and heat transfer on duct temperature, and mechanical responses to the induced temperature and flux gradients. Under the U.S. Department of Energy Office of Nuclear Energy’s Advanced Modeling and Simulation (NEAMS) Program [1], an integrated multiphysics approach is being developed to model the core bowing phenomena in liquid metal-cooled fast reactors with the Multiphysics Object Oriented Simulation Environment (MOOSE) [2]. In this methodology, the MOOSE-based reactor physics code Griffin [3] will solve the neutron transport equation and determine the power distribution. With the detailed power distribution from Griffin, the subchannel analysis codes MOOSE-Subchannel [4] and Pronghorn [5] are utilized to calculate the assembly temperature distribution. MOOSE’s Solid Mechanics [6] and Contact [7] Modules are leveraged to calculate the thermal expansion and duct bowing displacement with the duct wall temperature from thermal hydraulics calculation. In this work, an initial one-way coupling demonstration of the integrated multiphysics approach has been performed on a seven-assembly problem based on the sodium-cooled fast reactor ABR-1000 design [8]. The neutronics calculation with Griffin is not yet involved in the current simulation. MOOSE-Subchannel and Pronghorn evaluate fluid and solid temperature based on a fixed power distribution. In addition, one-way coupling is utilized in this coupled calculation, via Pronghorn passing the duct temperature data to the MOOSE Solid Mechanics calculation. An assessment of the Solid Mechanics module was performed in parallel to verify duct bowing behavior with duct-to-duct contact phenomenon [9]. The displacement from MOOSE Solid Mechanics is not yet transferred back and utilized in the Pronghorn and MOOSE-Subchannel calculation. This model will be available on the National Reactor Innovation Center (NRIC) Virtual Test Bed (VTB) repository [10]. Future stages of this work will involve solving problems of increasing complexity as well as adding more physics (e.g. reactor physics) to the integrated workflow to reach the end goal of modeling the core bowing phenomenon with an integrated multiphysics workflow.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Ducted Assembly Steady-State Heat Transfer Software (DASSH)

The Ducted Assembly Steady-State Heat transfer software (DASSH) is being developed at Argonne National Laboratory to perform a steady-state thermal fluids calculation to determine the coolant flow and temperature distribution for a hexagonal reactor core configuration with ducted assemblies. DASSH is intended to be used in the early stages of the reactor design process when assembly components can be undefined or are undergoing considerable design changes. DASSH provides a rapid assessment of the temperature and flow distribution to allow quick characterization of the system and identification of problem areas. This document is a guide for DASSH users. It summarizes the core capabilities of DASSH and highlights differences between DASSH and SE2-ANL. Instructions for obtaining and installing DASSH are provided along with some guidelines and recommendations for newer Python users. It covers the structure of the input file, provides directions for running DASSH, describes the various output files produced by the code, and provides instructions for visualizing data. Examples demonstrating various DASSH options are included. DASSH is under active development, so it is anticipated that this guide will grow and evolve as the code is updated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗