ECLSS Universal Waste Management System (UWMS) Metal Materials Compatibility Study - Elgiloy: Electrochemical and Crevice Corrosion Evaluation

Electrochemical evaluations were conducted on samples of Elgiloy in support of the materials compatibility program for the Environmental Control and Life Support System (ECLSS). Results were compared alongside three previously tested metals: Titanium 6Al-4V, Inconel 625, and Hastelloy C276. Titanium exhibited the best results of all the metals, indicating superior corrosive nobility and galvanic protection properties. Elgiloy demonstrated anti-corrosion behavior which appeared to be superior to the two nickel-chromium alloys. For this current effort, the results have clearly shown that Elgiloy possesses excellent corrosion protection properties and is galvanically compatible with the other three metals in the subject test media.

Lee, R. E.↗

Stress Corrosion Evaluation of Elgiloy Alloy for the ISS ECLSS — Universal Waste Management System

Elgiloy® alloy (UNS R30003)—a spring material per AMS 5876D (reference 1)—is one among several alloys recently evaluated for stress corrosion cracking resistance in support of the International Space Station (ISS) Environmental Control and Life Support System (ECLSS). Elgiloy was evaluated particularly for its expected use in the Universal Waste Management System (described in references 2 and 3). Data for other alloys previously evaluated were reported in references 4 and 5. Materials included in reference 4 are Inconel 625, Hastelloy® C276, commercially pure titanium, titanium with 6% aluminum and 4% vanadium (Ti6Al4V), extra-low interstitial Ti6Al4V, and Cronidur 30. The results for Nitinol 60 are in reference 5. During the water recovery process, the metallic components fabricated from these materials are exposed to acidic solutions used for waste treatment. The purpose of the current and previous stress corrosion evaluations is to determine if these materials have adequate stress corrosion resistance.

Torres, Pablo D.↗

Creating a Wastewater Technology ‘Toolbox’ for Space Exploration ECLSS

Life Support Systems (LSS) are essential for manned spaceflight; without them, humans would not survive. Upcoming long-duration missions demand robust environmental control LSS (ECLSS) due to their insolation and limited prospect for immediate resupply. As part of LSS, water purification systems will require high reliability, sustainability, and efficiency due to transport mass limitations, because routine water delivery will be very difficult and costly to resupply future habitats. This suggests a highly effective treatment method and reuse of every wastewater source. A variety of wastewater streams are generated by crew, and although not all are currently treated, habitat success will require each stream to be treated and utilized as a ‘resource’ rather than 'waste’. These wastewater streams include human wastewater (urine, feces), food waste (plate waste, inedible plant biomass), humidity condensate, hygiene water (shower, oral, handwash), and laundry. Proven technologies are often relied upon due to long-term operations. For future, longer-term missions, this paradigm must shift to include technologies based on meeting mission requirements rather than sacrificing productivity in lieu of proven existing technology capabilities. Many physical, chemical, and biological water-processing technologies are proven and established for terrestrial applications. Herein, these technologies were collected into a ‘toolbox’ to perform possible functions towards effective water purification steps in reduced gravity. Selection criteria are dependent on approach (physical, chemical, or biological), complexity/components, terrestrial performance, and potential applicability to space life support. Utilization of this ‘toolbox’ approach provides a streamline methodology for technology development and down-selection into future architecture in direct response to the dynamic space life support requirements. Establishing the ‘toolbox’ also provides organized and efficient identification of the most appropriate technologies. From there, the technologies with the largest potential to be configured for mission requirements can be further developed and appropriately assessed. This presentation seeks to provide a comprehensive review of space life support water purification requirements and challenges, as well as to present a ‘toolbox’ methodology of available technologies to aid in the difficult process of selecting appropriate LSS water purification for short and long-term NASA mission architectures.

Luke Roberson↗

ECLSS Four-Bed CO2 Scrubber Digital Twin

The ECLSS Digital Twin is a cloud-based simulation of the Four-Bed CO2 Scrubber, currently one of the primary means of removing carbon dioxide onboard the International Space Station, that operationalizes SME-developed multi-physics models and replicates conditions of the actual hardware in near real-time. In addition to providing insight into the system’s performance, it will enable prognostics, diagnostics, predictive maintenance, and simulated off-nominal scenarios. By leveraging digital representations, projects can save resources and gain a better understanding of their physical systems with the goal of building robust and reliable hardware for future deep space exploration. The use of data infrastructure in the cloud allows for streamlined analysis and visualization on a much larger scale than is possible with current tools.

Jared Wilson↗

Integrated ECLSS Ground Testbed Development and Status for 2025

The reliability of Spacecraft Life Support systems and the associated mass needed to support human spaceflight is one of the largest risks for missions beyond Low Earth Orbit. The reliability of these systems directly corresponds to the number of spares needed to support the mission. Performance improvements for these systems can reduce the consumables needed for long-duration missions. The only integrated spacecraft regenerative Life Support System exists in Low Earth Orbit. It is not practical to use the ISS system to fully understand the reliability of the technology as these systems are currently maintaining a livable environment and crew’s lives are dependent on the availability of these systems. To achieve advancement on reliability and mass, NASA has initiated the development of an Integrated ECLSS ground Testbed. This paper will provide a status on the testbed development, hardware development and areas for investigation. This paper will also cover planned testbed integration and support for Earth Independent Operations (EIO). This paper will be relevant to sessions: 205, 300, 301, 404, 406, 500, 50, 506, and 511.

Christopher Brown↗

Evaluation of Low-Energy Hydrogen Separation Method Using Metal-Organic Frameworks (MOFs) for Closed-Loop ECLSS Air Revitalization (CLEAR)

The State-of-the-Art (SOA) air revitalization architecture onboard the International Space Station (ISS) recovered approximately 50% of the oxygen (O 2 ) from metabolic carbon dioxide (CO 2 ) via the Sabatier process from 2011 to 2017. O 2 recovery is currently constrained by the limited availability of reactant hydrogen (H 2 ) preventing complete conversion of CO 2 to H 2 O. Increasing O 2 recovery within Closed-Loop ECLSS is essential to reducing resupply mass for long-duration manned missions; specifically focusing on water (H 2 O) which supplies H 2 for Sabatier via water electrolysis. Past ground test endeavors at Marshall Space Flight Center (MSFC) have attempted to recover H 2 from Sabatier-produced CH 4 using technologies such as carbon vapor deposition (CVD) and plasma pyrolysis. The byproducts of these technologies can act as a catalyst poison or reactor deadload to the Sabatier reactor. Hydrogen separation techniques must be utilized to maintain the Sabatier catalyst during gas recycling and must be scalable, non-energy intensive, and safe to operate in a habitation setting. Research indicated that metal-organic frameworks (MOFs) could meet these criteria and were tested for their capability to capture the various carbon-based gaseous products of CVD and plasma pyrolysis such as acetylene (C 2 H 2 ), ethylene (C 2 H 4 ), ethane (C 2 H 6 ), and carbon monoxide (CO) which would purify the hydrogen gas stream passing through the MOF. A sub-scale adsorption column was developed by Marshall Space Flight Center to test three MOF candidates against a synthetic gas mixture comprised of process-relevant carbonous gases and hydrogen to evaluate the separation capability of the MOFs. The results of the hydrogen separation capability, isothermal desorption capability, and demonstrated cyclic reuse of the MOF are presented in this paper.

Kagen Crawford↗

Shuttle ECLSS ammonia delivery capability

The possible effects of excessive requirements on ammonia flow rates required for entry cooling, due to extreme temperatures, on mission plans for the space shuttles, were investigated. An analysis of worst case conditions was performed, and indicates that adequate flow rates are available. No mission impact is therefore anticipated.

Source record↗

Crew and life support: ECLSS

The schedule NASA has proposed has four main elements. The focal point of all the life support activity is demonstrator for the initial space station. The demonstrator is composed of items that are ready for Phase C and D development. Technical options are scheduled during the early years to provide alternatives because the capability to substitute must be maintained. Growth technology and supporting research and technology (SR&T) will continue throughout the program life, and as new items emerge, the space station capability will be updated.

Drake, G.↗

Space station ECLSS integration analysis: Simplified General Cluster Systems Model, ECLS System Assessment Program enhancements

The data base verification of the ECLS Systems Assessment Program (ESAP) was documented and changes made to enhance the flexibility of the water recovery subsystem simulations are given. All changes which were made to the data base values are described and the software enhancements performed. The refined model documented herein constitutes the submittal of the General Cluster Systems Model. A source listing of the current version of ESAP is provided in Appendix A.

Ferguson, R. E.↗

Computer-aided-engineering system for modeling and analysis of ECLSS integration testing

The accurate modeling and analysis of two-phase fluid networks found in environmental control and life support systems is presently undertaken by computer-aided engineering (CAE) techniques whose generalized fluid dynamics package can solve arbitrary flow networks. The CAE system for integrated test bed modeling and analysis will also furnish interfaces and subsystem/test-article mathematical models. Three-dimensional diagrams of the test bed are generated by the system after performing the requisite simulation and analysis.

Sepahban, Sonbol↗

Space station ECLSS simplified integrated test

A discussion of the Space Station Simplified Integrated Test (SIT) was conducted. The first in a series of three integrated Environmental Control and Life Support (ECLS) system tests, the primary objectives of the SIT were to verify proper operation of ECLS subsystems functioning in an integrated fashion as well as to gather preliminary performance data for the partial ECLS system used in the test. A description of the SIT configuration, a summary of events, a discussion of anomalies that occurred during the test, and detailed results and analysis from individual measurements and water and gas samples taken during the test are included. The preprototype ECLS hardware used in the test is reported providing an overall process description and theory of operation for each hardware item.

Schunk, Richard G.↗

Space Station Freedom Environmental Control and Life Support System (ECLSS) phase 3 simplified integrated test trace contaminant control subsystem performance

Space Station Freedom environmental control and life support system testing has been conducted at Marshall Space Flight Center since 1986. The phase 3 simplified integrated test (SIT) conducted from July 30, 1989, through August 11, 1989, tested an integrated air revitalization system. During this test, the trace contaminant control subsystem (TCCS) was directly integrated with the bleed stream from the carbon dioxide reduction subsystem. The TCCS performed as expected with minor anomalies. The test set the basis for further characterizing the TCCS performance as part of advance air revitalization system configurations.

Perry, J. L.↗

Catalytic oxidation for treatment of ECLSS and PMMS waste streams

It is shown that catalytic oxidation is an effective technique for the removal of trace organic contaminants in a multifiltration potable processor's effluent. Essential elements of this technology are devices that deliver oxygen to the influent, and remove gaseous reaction byproducts from the effluent, via hollow-tube, gas-permeable membranes. Iodine, which poisons existing catalysis, is removed by a small deiodination bed prior to catalytic reactor entrance. The catalyst used is a mixture of Pt and Ru deposited on carbon, operating at 125-160 C and 39-90 psi pressures.

Akse, James R.↗

ECLSS medical support activities

During the period from April 10, 1990 to April 9, 1991, the Consortium for the Space Life Sciences provided technical assistance to the NASA/MSFC water recovery efforts. This assistance was in the form of literature reviews, technical recommendations, and presentations. This final report summarizes the activities completed during this period and identifies those areas requiring additional efforts. The tasks which the University of Alabama in Huntsville (UAH) water recovery team addressed were either identified by MSFC technical representatives or chosen from those outlined in the subject statement of work.

Crump, William J.↗

Advanced life support study. Modification 10: ECLSS logistical support analysis for Space Station Freedom

This addendum to the final report provides a description of the work performed under the subject contract. This report describes the work that was performed by SRS Technologies from Jan. 1992 - Jan. 1993. The work that was performed included the following: (1) a study of the Space Station Freedom (SSF) Preliminary Design Review (PDR) data package and an identification of the maintenance concept, structure, implementation plans, training plan, and the LSAR approach; development of a working ability with the ALSTAR and DATA Express software; (3) a review of the SSF maintenance concept; and (4) an update of the ALSTAR data base.

Source record↗

Catalytic oxidation for treatment of ECLSS and PMMS waste streams

Catalytic oxidation was added to the baseline multifiltration technology for use on the Space Station Freedom in order to convert low-molecular weight organic waste components such as alcohols, aldehydes, ketones, amides, and thiocarbamides to CO2 at low temperature (121 C), thereby reducing the total organic carbon (TOC) to below 500 ppb. The rate of reaction for the catalytic oxidation of aqueous organics to CO2 and water depends primarily upon the catalyst, temperature, and concentration of reactants. This paper describes a kinetic study conducted to determine the impact of each of these parameters upon the reaction rate. The results indicate that a classic kinetic model, the Langmuir-Hinshelwood rate equation for heterogeneous catalysis, can accurately represent the functional dependencies of this rate.

Akse, James R.↗