Search NASA⌕ Search

SEARCH · Search NASA

Results for “effective resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Intraband Radiometric Performance of the LANDSAT 4 Thematic Mapper

Those radiometric characteristics of the LANDSAT 4 thematic mapper (TM) that could be established without absolute calibration of spectral data were examined. Radiometrically raw (B type) data of three daytime and two nighttime scenes were used, including TM scenes from Washington, DC; northeast Arkansas; Cape Cod, MA; Roanoke, VA; Richmond, VA; and Silver Bell, AZ. The effective resolution in radiance is degraded by a factor of about 2 by the irregular width of the digital levels. Underpopulated levels are consistent over all bands and detectors, and are spaced an average of 4 digital numbers (DN) apart. In band 6, level 127 is avoided by a factor 30. Several detectors exhibit a change of gain with a period of several scans; the largest effect is about 4%. At high contrast boundaries, some of the detectors in band 5 commonly overshoot by several DN and require about 30 samples to recover. The high frequency noise level of each detector was characterized by the standard deviation of the first derivative in the sample direction across a flat field. A coherent-sinusoidal-noise pattern is evident in detector 1 of band 3. The correlation between the six reflective bands was determined and used to select three groups of bands whose aggregate first principal components contain the greatest total information. A composite of the first components of bands 1, 2, 3, bands 5 and 7, and band 4, together containing 89% of the information in the reflectance bands, has reduced the effect of noise.

Kieffer, H. H.↗

Evaluation of Satellite Remote Sensing Albedo Retrievals over the Ablation Area of the Southwestern Greenland Ice Sheet

MODerate resolution Imaging Spectroradiometer (MODIS) albedo products have been validated over spatially uniform, snow-covered areas of the Greenland ice sheet (GrIS) using the so-called single 'point-to-pixel' method. This study expands on this methodology by applying a 'multiple-point-to-pixel' method and examination of spatial autocorrelation (here using semivariogram analysis) by using in situ observations, high-resolution World- View-2 (WV-2) surface reflectances, and MODIS Collection V006 daily blue-sky albedo over a spatially heterogeneous surfaces in the lower ablation zone in southwest Greenland. Our results using 232 ground-based samples within two MODIS pixels, one being more spatial heterogeneous than the other, show little difference in accuracy among narrow and broad band albedos (except for Band 2). Within the more homogenous pixel area, in situ and MODIS albedos were very close (error varied from −4% to +7%) and within the range of ASD standard errors. The semivariogram analysis revealed that the minimum observational footprint needed for a spatially representative sample is 30 m. In contrast, over the more spatially heterogeneous surface pixel, a minimum footprint size was not quantifiable due to spatial autocorrelation, and far exceeds the effective resolution of the MODIS retrievals. Over the high spatial heterogeneity surface pixel, MODIS is lower than ground measurements by 4-7%, partly due to a known in situ undersampling of darker surfaces that often are impassable by foot (e.g., meltwater features and shadowing effects over crevasses). Despite the sampling issue, our analysis errors are very close to the stated general accuracy of the MODIS product of 5%. Thus, our study suggests that the MODIS albedo product performs well in a very heterogeneous, low-albedo, area of the ice sheet ablation zone. Furthermore, we demonstrate that single 'point-to-pixel' methods alone are insufficient in characterizing and validating the variation of surface albedo displayed in the lower ablation area. This is true because the distribution of in situ data deviations from MODIS albedo show a substantial range, with the average values for the 10th and 90th percentiles being −0.30 and 0.43 across all bands. Thus, if only single point is taken for ground validation, and is randomly selected from either distribution tails, the error would appear to be considerable. Given the need for multiple in-situ points, concurrent albedo measurements derived from existing AWSs, (low-flying vehicles (airborne or unmanned) and high-resolution imagery (WV-2)) are needed to resolve high sub-pixel variability in the ablation zone, and thus, further improve our characterization of Greenland's surface albedo.

Ablation zone↗

DEPENDENCE OF THE TURBULENT VELOCITY FIELD ON GAS DENSITY IN L1551

We have carried out mapping observations of the entire L1551 molecular cloud with about 2 pc x 2 pc size in the {sup 12}CO(1-0) line with the Nobeyama 45 m radio telescope at the high effective resolution of 22'' (corresponding to 0.017 pc at the distance of 160 pc), and analyzed the {sup 12}CO data together with the {sup 13}CO(1-0) and C{sup 18}O(1-0) data from the Nobeyama Radio Observatory database. We derived the new non-thermal line width-size relations, {sigma}{sub NT} {proportional_to} L {sup {gamma}}, for the three molecular lines, corrected for the effect of optical depth and the line-of-sight integration. To investigate the characteristic of the intrinsic turbulence, the effects of the outflows were removed. The derived relations are ({sigma}{sub NT}/km s{sup -1}) = (0.18 {+-} 0.010)(L/pc){sup 0.45{+-}0.095}, (0.20 {+-} 0.020)(L/pc){sup 0.48{+-}0.091}, and (0.22 {+-} 0.050) (L/pc){sup 0.54{+-}0.21} for the {sup 12}CO, {sup 13}CO, and C{sup 18}O lines, respectively, suggesting that the line width-size relation of the turbulence very weakly depends on our observed molecular lines, i.e., the relation does not change between the density ranges of 10{sup 2}-10{sup 3} and 10{sup 3}-10{sup 4} cm{sup -3}. In addition, the relations indicate that incompressible turbulence is dominant at the scales smaller than 0.6 pc in L1551. The power spectrum indices converted from the relations, however, seem to be larger than that of the Kolmogorov spectrum for incompressible flow. The disagreement could be explained by the anisotropy in the turbulent velocity field in L1551, as expected in MHD turbulence. Actually, the autocorrelation functions of the centroid velocity fluctuations show larger correlation along the direction of the magnetic field measured for the whole Taurus cloud, which is consistent with the results of numerical simulations for incompressible MHD flow.

79 ASTRONOMY AND ASTROPHYSICS↗

High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisition

Purpose: One of the technical advantages of functional magnetic resonance imaging (fMRI) is its precise localization of changes from neuronal activities. While current practice of fMRI acquisition at voxel size around 3 × 3 × 3 mm{sup 3} achieves satisfactory results in studies of basic brain functions, higher spatial resolution is required in order to resolve finer cortical structures. This study investigated spatial resolution effects on brain fMRI experiments using balanced steady-state free precession (bSSFP) imaging with 0.37 mm{sup 3} voxel volume at 3.0 T. Methods: In fMRI experiments, full and unilateral visual field 5 Hz flashing checkerboard stimulations were given to healthy subjects. The bSSFP imaging experiments were performed at three different frequency offsets to widen the coverage, with functional activations in the primary visual cortex analyzed using the general linear model. Variations of the spatial resolution were achieved by removing outerk-space data components. Results: Results show that a reduction in voxel volume from 3.44 × 3.44 × 2 mm{sup 3} to 0.43 × 0.43 × 2 mm{sup 3} has resulted in an increase of the functional activation signals from (7.7 ± 1.7)% to (20.9 ± 2.0)% at 3.0 T, despite of the threefold SNR decreases in the original images, leading to nearly invariant functional contrast-to-noise ratios (fCNR) even at high spatial resolution. Activation signals aligning nicely with gray matter sulci at high spatial resolution would, on the other hand, have possibly been mistaken as noise at low spatial resolution. Conclusions: It is concluded that the bSSFP sequence is a plausible technique for fMRI investigations at submillimeter voxel widths without compromising fCNR. The reduction of partial volume averaging with nonactivated brain tissues to retain fCNR is uniquely suitable for high spatial resolution applications such as the resolving of columnar organization in the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Topography of the Lunar Poles and Application to Geodesy with the Lunar Reconnaissance Orbiter

The Lunar Orbiter Laser Altimeter (LOLA) [1] onboard the Lunar Reconnaissance Orbiter (LRO) [2] has been operating continuously since July 2009 [3], accumulating approx.5.4 billion measurements from 2 billion on-orbit laser shots. LRO s near-polar orbit results in very high data density in the immediate vicinity of the lunar poles, which are each sampled every ~2h. With more than 10,000 orbits, high-resolution maps can be constructed [4] and studied [5]. However, this requires careful processing of the raw data, as subtle errors in the spacecraft position and pointing can lead to visible artifacts in the final map. In other locations on the Moon, ground tracks are subparallel and longitudinal separations are typically a few hundred meters. Near the poles, the track intersection angles can be large and the inter-track spacing is small (above 80 latitude, the effective resolution is better than 50m). Precision Orbit Determination (POD) of the LRO spacecraft [6] was performed to satisfy the LOLA and LRO mission requirements, which lead to a significant improvement in the orbit position knowledge over the short-release navigation products. However, with pixel resolutions of 10 to 25 meters, artifacts due to orbit reconstruction still exist. Here, we show how the complete LOLA dataset at both poles can be adjusted geometrically to produce a high-accuracy, high-resolution maps with minimal track artifacts. We also describe how those maps can then feedback to the POD work, by providing topographic base maps with which individual LOLA altimetric measurements can be contributing to orbit changes. These direct altimetry constraints improve accuracy and can be used more simply than the altimetric crossovers [6].

Mazarico, Erwan↗

Microstructure reconstruction of battery polymer separators by fusing 2D and 3D image data for transport property analysis

A new approach to generate high-fidelity 3D microstructure reconstructions by leveraging resolution and sample volume characteristics from 2D and 3D microscopy methods is presented here. This approach is employed to model the microstructure of a highly orthotropic polypropylene separator used in lithium-ion batteries, which have challenging multi-scale features of fibrils (<100 nm) and lamellae (>100 nm) to resolve in 3D. Phase contrast nano X-ray computed tomographic data are used to reconstruct the lamellae phase, while 2D scanning electron microscopy data are used to characterize sub-100 nm microstructure features such as the thin fibrils that are beyond the effective resolution of X-ray computed tomography. Fibril geometries are reconstructed stochastically based on the 2D higher resolution data, and integrated with the lamellae geometries in 3D space. Transport property analyses are performed to investigate the bias of microstructure models without considering the fibrils. A sensitivity study is also conducted to facilitate understanding of the relationship between microstructure characteristics and transport properties.

25 ENERGY STORAGE↗

AGB fluorine nucleosynthesis studied by means of Trojan-horse method: the case of {sup 15}N(p,{alpha}){sup 12}C

The low-energy bare-nucleus cross section for {sup 15}N(p,{alpha}){sup 12}C is extracted by means of the Trojan-horse Method applied to the {sup 2}H({sup 15}N,{alpha}){sup 12}C)n reaction at E{sub beam} = 60 MeV. The astrophysical S-factor is deduced and compared to the direct data in the same energy region. A fair agreement with direct data down to 80 keV is found if energy resolution effects are taken into account.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Top quark jets at the LHC

We investigate the reconstruction of high p{sub T} hadronically decaying top quarks at the Large Hadron Collider. One of the main challenges in identifying energetic top quarks is that the decay products become increasingly collimated. This reduces the efficacy of conventional reconstruction methods that exploit the topology of the top quark decay chain. We focus on the cases where the decay products of the top quark are reconstructed as a single jet, a 'top jet'. The most basic 'top-tagging' method based on jet mass measurement is considered in detail. To analyze the feasibility of the top-tagging method, both theoretical and experimental aspects of the large QCD jet background contribution are examined. Based on a factorization approach, we derive a simple analytic approximation for the shape of the QCD jet mass spectrum. We observe very good agreement with the Monte Carlo simulation. We consider high-p{sub T} tt production in the standard model as an example, and show that our theoretical QCD jet mass distributions can efficiently characterize the background via sideband analyses. We show that with 25 fb{sup -1} of data, our approach allows us to resolve top jets with p{sub T}{>=}1 TeV, from the QCD background, and about 1.5 TeV top jets with 100 fb{sup -1}, without relying on b-tagging. To further improve the significance we consider jet shapes (recently analyzed in 10), which resolve the substructure of energy flow inside cone jets. A method of measuring the top quark polarization by using the transverse momentum of the bottom quark is also presented. The main advantages of our approach are (i) the mass distributions are driven by first principle calculations, instead of relying solely on Monte Carlo simulation; (ii) for high p{sub T} jets (p{sub T}{>=}1 TeV), IR-safe jet shape variables are robust against detector resolution effects. Our analysis can be applied to other boosted massive particles such as the electroweak gauge bosons and the Higgs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uranium measurements in the field using high-resolution cadmium zinc telluride detectors

A new generation of cadmium zinc telluride (CZT) detectors has become available and is being evaluated by the International Atomic Energy Agency (IAEA) for safeguards verifications in the field. The new CZT detector, model M400, is a room temperature spectrometer manufactured by H3D, Inc. The M400 demonstrates superior energy resolution, effective isotope identification capabilities, and convenient usability features when tested in a controlled laboratory environment. These characteristics define the M400 as a potential platform for IAEA field detection applications, which could become suitable for nuclear material characterization (e.g., enrichment verification) and nuclear safeguards missions. The capabilities of gamma spectrometry codes including Fixed energy, Response function Analysis with Multiple efficiencies (FRAM) from Los Alamos National Laboratory, CZT for Uranium (CZTU) from Lawrence Livermore National Laboratory, and Gamma Detector Response and Analysis Software (GADRAS) from Sandia National Laboratories were adapted for M400 spectra, and the performance of the codes has been validated. This was reported in a prior work. To further validate the performance of the high-energy resolution CZT detector and the isotopic analysis codes, a field measurement campaign consisting of uranium hexafluoride (UF 6 ) cylinder measurements was conducted at a fuel fabrication facility. A total of 34 Type 30B cylinders containing UF6 were measured using three different M400 CZT detectors. Each detector was outfitted with a custom rectangular collimator and shield made out T-Flex®, a tungsten-impregnated polymer. Measurements were performed at three different locations of the cylinder, ensuring that the measurement geometry satisfied the infinite thickness criterion. The spectra from the M400 CZT were analyzed using the code General Enrichment Meter (GEM). For analyzing the gamma-ray spectra from UF 6 cylinder, the GEM code is the appropriate tool since it relies only on the gamma-ray emissions from 235 U and not from other isotopes. Results from the spectral analysis were compared with the known abundance of 235 U in the cylinders, as well as with the International Target Values 2020 (ITV2020). The suitability of the different underlying techniques used by the various codes for UF 6 analysis is discussed. The challenges of measuring UF 6 contained in cylinders and mitigation strategies are highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-214: Dose Reduction by Spatially Optimized Image Quality Via Fluence Modulated Proton CT (FMpCT)

Purpose: Proton CT (pCT) is a promising imaging modality for reducing range uncertainty in image-guided proton therapy. Range uncertainties partially originate from X-ray CT number conversion to stopping power ratio (SPR) and are limiting the exploitation of the full potential of proton therapy. In this study we explore the concept of spatially dependent fluence modulated proton CT (FMpCT), for achieving optimal image quality in a clinical region of interest (ROI), while reducing significantly the imaging dose to the patient. Methods: The study was based on simulated ideal pCT using pencil beam (PB) scanning. A set of 250 MeV protons PBs was used to create 360 projections of a cylindrical water phantom and a head and neck cancer patient. The tomographic images were reconstructed using a filtered backprojection (FBP) as well as an iterative algorithm (ITR). Different fluence modulation levels were investigated and their impact on the image was quantified in terms of SPR accuracy as well as noise within and outside selected ROIs, as a function of imaging dose. The unmodulated image served as reference. Results: Both FBP reconstruction and ITR without total variation (TV) yielded image quality in the ROIs similar to the reference images, for modulation down to 0.1 of the full proton fluence. The average dose was reduced by 75% for the water phantom and by 40% for the patient. FMpCT does not improve the noise for ITR with TV and modulation 0.1. Conclusion: This is the first work proposing and investigating FMpCT for producing optimal image quality for treatment planning and image guidance, while simultaneously reducing imaging dose. Future work will address spatial resolution effects and the impact of FMpCT on the quality of proton treatment plans for a prototype pCT scanner capable of list mode data acquisition. Acknowledgement: DFG-MAP DFG - Munich-Centre for Advanced Photonics (MAP)

60 APPLIED LIFE SCIENCES↗

BOREAS AFM-12 1-km AVHRR Seasonal Land Cover Classification

The Boreal Ecosystem-Atmosphere Study (BOREAS) Airborne Fluxes and Meteorology (AFM)-12 team's efforts focused on regional scale Surface Vegetation and Atmosphere (SVAT) modeling to improve parameterization of the heterogeneous BOREAS landscape for use in larger scale Global Circulation Models (GCMs). This regional land cover data set was developed as part of a multitemporal one-kilometer Advanced Very High Resolution Radiometer (AVHRR) land cover analysis approach that was used as the basis for regional land cover mapping, fire disturbance-regeneration, and multiresolution land cover scaling studies in the boreal forest ecosystem of central Canada. This land cover classification was derived by using regional field observations from ground and low-level aircraft transits to analyze spectral-temporal clusters that were derived from an unsupervised cluster analysis of monthly Normalized Difference Vegetation Index (NDVI) image composites (April-September 1992). This regional data set was developed for use by BOREAS investigators, especially those involved in simulation modeling, remote sensing algorithm development, and aircraft flux studies. Based on regional field data verification, this multitemporal one-kilometer AVHRR land cover mapping approach was effective in characterizing the biome-level land cover structure, embedded spatially heterogeneous landscape patterns, and other types of key land cover information of interest to BOREAS modelers.The land cover mosaics in this classification include: (1) wet conifer mosaic (low, medium, and high tree stand density), (2) mixed coniferous-deciduous forest (80% coniferous, codominant, and 80% deciduous), (3) recent visible bum, vegetation regeneration, or rock outcrops-bare ground-sparsely vegetated slow regeneration bum (four classes), (4) open water and grassland marshes, and (5) general agricultural land use/ grasslands (three classes). This land cover mapping approach did not detect small subpixel-scale landscape features such as fens, bogs, and small water bodies. Field observations and comparisons with Landsat Thematic Mapper (TM) suggest a minimum effective resolution of these land cover classes in the range of three to four kilometers, in part, because of the daily to monthly compositing process. In general, potential accuracy limitations are mitigated by the use of conservative parameterization rules such as aggregation of predominant land cover classes within minimum horizontal grid cell sizes of ten kilometers. The AFM-12 one-kilometer AVHRR seasonal land cover classification data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).

Steyaert, Lou↗

STRUCTURE AND COMPOSITION OF MOLECULAR CLOUDS WITH CN ZEEMAN DETECTIONS I: W3(OH)

We have carried out a multi-species study of a region which has had previous measurements of strong magnetic fields through the CN Zeeman effect in order to explore the relationship between CN and N{sub 2}H{sup +}, both of which have evidence that they remain in the gas phase at densities of 10{sup 5}-10{sup 6} cm{sup -3}. To achieve this, we map the 1 arcmin{sup 2} region around the UCHII region of W3(OH) using the Combined Array for Millimeter-wave Astronomy (CARMA). Approximately 105 hr of data were collected in multiple array configurations to produce maps with an effective resolution of {approx}2.''5 at high signal-to-noise ratios (S/Ns) in CN, C{sup 18}O, HCN, HCO{sup +}, N{sub 2}H{sup +}, and two continuum bands (91.2 GHz and 112 GHz). These data allow us to compare tracer molecules associated with both low- and high-density regions to infer gas properties. We determine that CARMA resolves out approximately 35% of the CN emission around W3(OH) when compared with spectra obtained from the IRAM 30 m telescope. The presence of strong absorption lines toward the continuum source in three of the molecular transitions infers the presence of a cold, dark, optically thick region in front of the continuum source. In addition, the presence of high-velocity emission lines near the continuum source shows the presence of hot clumpy emission behind the continuum source. These data determine that future high-resolution interferometric CN Zeeman measurements which cannot currently be performed (due to technical limitations of current telescopes) are feasible. We confirm that CN is indeed a good tracer for high-density regions; with certain objects such as W3(OH) it appears to be a more accurate tracer than N{sub 2}H{sup +}.

79 ASTRONOMY AND ASTROPHYSICS↗

Expected Performance of the GLAST Burst Monitor

The GLAST Burst Monitor (GBM) will enhance LAT observations of GRBs by extending the spectral coverage from the LAT threshold down to {approx}8 keV, and will provide a trigger for re-orienting the spacecraft to observe delayed emission from selected bursts outside the LAT field of view. GBM consists of twelve NaI scintillation detectors operating in the 8 keV to 1 MeV energy range and two BGO scintillation detectors operating in the 150 keV to 30 MeV energy range. Detector resolution, effective area, and angular response have been determined by calibrations. Analyses indicate that the on-board burst threshold will be {approx}0.7 photons cm{sup -2}s{sup -1} and the on-board burst localization accuracy will typically be better than 8 deg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative analysis of Sr2RuO4 angle-resolved photoemission spectra: Many-body interactions in a model Fermi liquid

Angle-resolved photoemission spectroscopy (ARPES) spectra hold a wealth of information about the many-body interactions in a correlated material. However, the quantitative analysis of ARPES spectra to extract the various coupling parameters in a consistent manner is extremely challenging, even for a model Fermi liquid system. We propose a fitting procedure which allows quantitative access to the intrinsic line shape, deconvolved of energy and momentum resolution effects, of the correlated two-dimensional material Sr2RuO4. In correlated two-dimensional materials, we find an ARPES linewidth that is narrower than its binding energy, a key property of quasiparticles within Fermi liquid theory. We also find that when the electron-electron scattering component is separated from the electron-phonon and impurity scattering terms, it decreases with a functional form compatible with Fermi liquid theory as the Fermi energy is approached. In combination with the previously determined Fermi surface, these results give a complete picture of a Fermi liquid system via ARPES. Furthermore, we show that the magnitude of the extracted imaginary part of the self-energy is in remarkable agreement with DC transport measurements.

36 MATERIALS SCIENCE↗

THE TWO-PHASE FORMATION HISTORY OF SPIRAL GALAXIES TRACED BY THE COSMIC EVOLUTION OF THE BAR FRACTION

We study the evolution of galactic bars and the link with disk and spheroid formation in a sample of zoom-in cosmological simulations. Our simulation sample focuses on galaxies with present-day stellar masses in the 10{sup 10}-10{sup 11} M{sub Sun} range, in field and loose group environments, with a broad variety of mass growth histories. In our models, bars are almost absent from the progenitors of present-day spirals at z > 1.5, and they remain rare and generally too weak to be observable down to z Almost-Equal-To 1. After this characteristic epoch, the fractions of observable and strong bars rise rapidly, bars being present in 80% of spiral galaxies and easily observable in two thirds of these at z {<=} 0.5. This is quantitatively consistent with the redshift evolution of the observed bar fraction, although the latter is presently known up to z Almost-Equal-To 0.8 because of band-shifting and resolution effects. Our models hence predict that the decrease in the bar fraction with increasing redshift should continue with a fraction of observable bars not larger than 10%-15% in disk galaxies at z > 1. Our models also predict later bar formation in lower-mass galaxies, in agreement with existing data. We find that the characteristic epoch of bar formation, namely redshift z Almost-Equal-To 0.8-1 in the studied mass range, corresponds to the epoch at which today's spirals acquire their disk-dominated morphology. At higher redshift, disks tend to be rapidly destroyed by mergers and gravitational instabilities and rarely develop significant bars. We hence suggest that the bar formation epoch corresponds to the transition between an early 'violent' phase of spiral galaxy formation at z {>=} 1 and a late 'secular' phase at z {<=} 0.8. In the secular phase, the presence of bars substantially contributes to the growth of the (pseudo-)bulge, but the bulge mass budget remains statistically dominated by the contribution of mergers, interactions, and disk instabilities at high redshift. Early bars at z > 1 are often short-lived, while most of the bars formed at z {<=} 1 persist down to z = 0, late cosmological gas infall being necessary to maintain some of them.

79 ASTRONOMY AND ASTROPHYSICS↗

Atmospheric effect on spatial resolution of surface imagery

The combined sensor-atmosphere characteristics, defined by the modulation transfer function, are calculated and used to evaluate the apparent resolution of remotely sensed imagery as determined by those characteristics. The atmospheric effect on the upward radiance is described, and the reduction of the apparent spatial resolution due to the atmospheric effect is discussed. The atmospheric effect on remote sensing is compared to the effect of the sensor's pixel size, and results are presented for the maximum resolution that can be achieved in the presence of atmospheric blurring effects.

Kaufman, Y. J.↗

Measurements of CP Asymmetries and Branching Fractions of Two-Body Charmless Decays of $B^0$ and $B^0_s$ Mesons

The thesis is organized as follows: Chapter 1 describes the theoretical framework of non-leptonic B$$0\atop{s}$$ → H +h' - decays, with a simple overview of the CP violation mechanism within the Standard Model and of the most used phenomenological approaches in the evaluation of strong interaction contributions. The chapter contains also a review of the theoretical expectations and the current experimental measurements along with a discussion about the importance of studying such decays. Chapter 2 contains a general description of the Tevatron collider and of the CDF II detector. Chapter 3 is devoted to the description of the data sample used for the measurement and the method used in extracting the signal from the background. Particular attention is dedicated to the on-line trigger selection, which is crucial to collect a sample enriched in B$$0\atop{s}$$ → h +h' - decays. Chapter 4 shows how the information from kinematics and particle identification was used to achieve a statistical discrimination amongst modes to extract individual measurements. The available resolutions in mass or in particle identification are separately insufficient for an event-by-event separation of B$$0\atop{s}$$ → h +h' - modes. The choice of observables and the technique used to combine them is an important and innovative aspect of the analysis described in this thesis. Chapter 5 is devoted to the accurate determination of the invariant mass lineshape. This is a crucial ingredient for resolving overlapping mass peaks. This chapter details all resolution effects with particular attention at the tails due to the emission of low-energy photons from charged kaons and pions in the final state (FSR). For the first time the effect of FSR has been accurately accounted for in a CDF analysis. Chapter 6 describes how kinematic and PID information, discussed in chap. 4 and chap. 5 were combined in a maximum Likelihood fit to statistically determine the composition of the B$$0\atop{s}$$ → h +h' - sample. This kinematics-PID combined fit has been developed and performed for the first time at CDF in the analysis presented in this thesis and this methodology was later inherited by several other analyses. Chapter 7 is devoted to the study of the isolation variable, which is a crucial handle to enhance the signal-to-background ratio in the off-line selection. It exploits the property that the b-hadrons tend to carry a larger fraction of the transverse momentum of the particles produced in the fragmentation, with respect to lighter hadrons. Since the simulators do not accurately reproduce the fragmentation processes, this chapter is devoted to the study of the control data sample of B$$0\atop{s}$$ → J/ΨX decays to probe the characteristics of this variable. Chapter 8 describes an innovative procedure used to optimize the selection to minimize the statistical uncertainty on the quantities one wishes to measure. The procedure is based on the fit of composition described in chap. 6. Chapter 9 reports the results of the fit of composition described in chap. 6 and the cross-checks performed to verify the goodness of the fit of composition. In order to translate the parameters returned from the fit into physics measurements the relative efficiency corrections between the various decay modes need to be applied. Chapter 10 is devoted to the description of these corrections. Chapter 11 describes the measurement of the detector-induced charge asymmetry between positively and negatively charged kaons and pions, due to their different probability of strong interaction in the tracker material using the real data. This allows to extract the acceptance correction factor for the CP asymmetries measurement without any external inputs from the simulation, and to perform a powerful check of whole analysis. Chapter 12 describes the main sources of systematic uncertainties and the method used to evaluate the significance of the results on rare modes. The final results of the measurements and their interpretation are discussed in chap. 13.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sculpting the Plasmonic Responses of Nanoparticles by Directed Electron Beam Irradiation

Spatial confinement of matter in functional nanostructures has propelled these systems to the forefront of nanoscience, both as a playground for exotic physics and quantum phenomena and in multiple applications including plasmonics, optoelectronics, and sensing. In parallel, the emergence of monochromated electron energy loss spectroscopy (EELS) has enabled exploration of local nanoplasmonic functionalities within single nanoparticles and the collective response of nanoparticle assemblies, providing deep insight into associated mechanisms. However, modern synthesis processes for plasmonic nanostructures are often limited in the types of accessible geometry, and materials and are limited to spatial precisions on the order of tens of nm, precluding the direct exploration of critical aspects of the structure-property relationships. Here, the atomic-sized probe of the scanning transmission electron microscope is used to perform precise sculpting and design nanoparticle configurations. Using low-loss EELS, dynamic analyses of the evolution of the plasmonic response are provided. It is shown that within self-assembled systems of nanoparticles, individual nanoparticles can be selectively removed, reshaped, or patterned with nanometer-level resolution, effectively modifying the plasmonic response in both space and energy. This process significantly increases the scope for design possibilities and presents opportunities for unique structure development, which are ultimately the key for nanophotonic design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗