Search NASA⌕ Search

SEARCH · Search NASA

Results for “elastic electron scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Analysis of the multicomponent relativistic Boltzmann equation for electron scattering in big bang nucleosynthesis

Big-bang nucleosynthesis (BBN) is valuable as a means to constrain the physics of the early universe and it is the only probe of the radiation-dominated epoch. A fundamental assumption in BBN is that the nuclear velocity distributions obey Maxwell-Boltzmann (MB) statistics as they do in stars. Specifically, the BBN epoch is characterized by a dilute baryon plasma for which the velocity distribution of nuclei is mainly determined by the dominant Coulomb elastic scattering with mildly relativistic electrons. One must therefore deduce the momentum distribution for reacting nuclei from the multicomponent relativistic Boltzmann equation. However, the full multicomponent relativistic Boltzmann equation has only recently been analyzed and its solution has only been worked out in special cases. Moreover, a variety of schemes have been proposed that introduce nonthermal components into the BBN environment which can alter the thermal distribution of reacting nuclei. Here, we construct the relativistic Boltzmann equation in the context of BBN. We also derive a Langevin model and perform relativistic Monte-Carlo simulations which clarify the baryon distribution during BBN and can be used to analyze any relaxation from a nonthermal injection. Further, we show by these analyses that the thermalization process leads to a nuclear distribution function that remains very close to MB statistics even during the most relativistic environment relevant to BBN. Hence, the predictions of standard BBN remain unchanged.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron Skin Measurement of 208Pb and 48Ca Using Parity Violating Electron Scattering

Parity-violating electron scattering experiments (PVES) provides a clean probe of neutron densities that is model independent and free from strong interaction uncertainties in interpretation. The PREX-2 and CREX experiments were run in 2019 and 2020 at Jefferson laboratory measured the nucleon skin thickness, the difference between the r.m.s. neutron radius Rn and the r.m.s. proton radius Rp, of 208Pb and 48Ca via parity violating electroweak asymmetry in the elastic scattering of longitudinally polarized electrons. PREX-2 experiment was performed with 950 MeV electrons scattered at a 5¿ angle with Q2 = 0.00616 ± 0.00004 (GeV/c)2, while CREX used 2182 MeV electrons at the same angle with Q2 = 0.0297 ± 0.0002 (GeV/c)2. For PREX-2 the measured asymmetry was AP V = 550 ± 16 (stat.) ± (syst.) ppb, which corresponds to Rskin = 0.278 ± 0.078 (exp.) ± 0.012 (theo.) fm. The CREX asymmetry was AP V = 2668 ± 106 (stat.) ± 40 (syst.) ppb, which corresponds to Rskin = 0.121 ± 0.026 (exp.) ±0.024 (model) fm. One of the crucial systematic uncertainty that PREX-2 and CREX were sensitive to was the non-parity violating asymmetries that resulted from the helicity correlated false asymmetries in the polarized electron beam. There was a lot of work put towards understanding and suppressing the asymmetries arising from these effects. The parity violating asymmetry measurement required a very precise determination of the electron beam polarization. To accurately determine the beam polarization, a Compton polarimeter was used during both PREX-2 and CREX. A careful alignment of the laser to the Fabry-Perot cavity, data analysis and systematic control was employed to get a precise beam polarization result for the experiments. The PREX-2 measurement has broad implications for increasing our knowledge about neutron star structure and the equation of state of nuclear matter. The combined PREX and CREX results will have implications for future energy density functional calculations and the theory of nuclear structure.

Premathilake, Sachinthani↗

Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment

Abstract The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $$\upbeta $$ β -decay endpoint region with a sensitivity on $$m_\nu $$ m ν of 0.2 $$\hbox {eV}/\hbox {c}^2$$ eV / c 2 (90% CL). For this purpose, the $$\upbeta $$ β -electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6 keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $$\upbeta $$ β -electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique. We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% $$\hbox {T}_2$$ T 2 gas mixture at 30 K, as used in the first KATRIN neutrino-mass analyses, as well as a $$\hbox {D}_2$$ D 2 gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $$\sigma (m_\nu ^2)< {{10}^{-2}}{\hbox {eV}^{2}}$$ σ ( m ν 2 ) < 10 - 2 eV 2 [1] in the KATRIN neutrino-mass measurement to a subdominant level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonequilibrium Thermodynamics of Colloidal Gold Nanocrystals Monitored by Ultrafast Electron Diffraction and Optical Scattering Microscopy

Metal nanocrystals exhibit important optoelectronic and photocatalytic functionalities in response to light. These dynamic energy conversion processes have been commonly studied by transient optical probes to date, but an understanding of the atomistic response following photoexcitation has remained elusive. In this paper, we use femtosecond resolution electron diffraction to investigate transient lattice responses in optically excited colloidal gold nanocrystals, revealing the effects of nanocrystal size and surface ligands on the electron–phonon coupling and thermal relaxation dynamics. First, we uncover a strong size effect on the electron–phonon coupling, which arises from reduced dielectric screening at the nanocrystal surfaces and prevails independent of the optical excitation mechanism (i.e., inter- and intraband). Second, we find that surface ligands act as a tuning parameter for hot carrier cooling. Particularly, gold nanocrystals with thiol-based ligands show significantly slower carrier cooling as compared to amine-based ligands under intraband optical excitation due to electronic coupling at the nanocrystal/ligand interfaces. Finally, we spatiotemporally resolve thermal transport and heat dissipation in photoexcited nanocrystal films by combining electron diffraction with stroboscopic elastic scattering microscopy. Taken together, we resolve the distinct thermal relaxation time scales ranging from 1 ps to 100 ns associated with the multiple interfaces through which heat flows at the nanoscale. Our findings provide insights into optimization of gold nanocrystals and their thin films for photocatalysis and thermoelectric applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An experimental program with high duty-cycle polarized and unpolarized positron beams at Jefferson Lab

Positron beams, both polarized and unpolarized, are identified as important ingredients for the experimental programs at the next generation of lepton accelerators. In the context of the hadronic physics program at Jefferson Lab (JLab), positron beams are complementary, even essential, tools for a precise understanding of the electromagnetic structure of nucleons and nuclei, in both the elastic and deep-inelastic regimes. For instance, elastic scattering of polarized and unpolarized electrons and positrons from the nucleon enables a model independent determination of its electromagnetic form factors. Also, the deeply-virtual scattering of polarized and unpolarized electrons and positrons allows unambiguous separation of the different contributions to the cross section of the lepto-production of photons and of lepton-pairs, enabling an accurate determination of the nucleons and nuclei generalized parton distributions, and providing an access to the gravitational form factors of the energy-momentum tensor. Furthermore, positron beams offer the possibility of alternative tests of the Standard Model of particle physics through the search of a dark photon, the precise measurement of electroweak couplings, and the investigation of charged lepton flavor violation. This document discusses the perspectives of an experimental program with high duty-cycle positron beams at JLab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Elastic positron–proton scattering at low Q$^2$

Systematic differences in the the proton's charge radius, as determined by ordinary atoms and muonic atoms, have caused a resurgence of interest in elastic lepton scattering measurements. The proton's charge radius, defined as the slope of the charge form factor at Q$^2$=0, does not depend on the probe. Any difference in the apparent size of the proton, when determined from ordinary versus muonic hydrogen, could point to new physics or need for the higher order corrections. While recent measurements seem to now be in agreement, there is to date no high precision elastic scattering data with both electrons and positrons. A high precision proton radius measurement could be performed in Hall B at Jefferson Lab with a positron beam and the calorimeter based setup of the PRad experiment. This measurement could also be extended to deuterons where a similar discrepancy has been observed between the muonic and electronic determination of deuteron charge radius. A new, high precision measurement with positrons, when viewed alongside electron scattering measurements and the forthcoming MUSE muon scattering measurement, could help provide new insights into the origins of the proton radius puzzle, and also provide new experimental constraints on radiative correction calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of mosaic crystal instrument functions on x-ray Thomson scattering diagnostics

Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.

47 OTHER INSTRUMENTATION↗

Precision Determination of the Neutral Weak Form Factor of Ca 48

In this work, we report a precise measurement of the parity-violating asymmetry $A_{\rm PV}$ in the elastic scattering of longitudinally polarized electrons from $^{48}{\rm Ca}$. We measure $A_{\rm PV} =2668\pm 106\ {\rm (stat)}\pm 40\ {\rm (syst)}$ parts per billion, leading to an extraction of the neutral weak form factor $F_{\rm W} (q=0.8733$ fm$^{-1}) = 0.1304 \pm 0.0052 \ {\rm (stat)}\pm 0.0020\ {\rm (syst)}$ and the charge minus the weak form factor $F_{\rm ch} - F_{\rm W} = 0.0277\pm 0.0055$. The resulting neutron skin thickness $R_n-R_p=0.121 \pm 0.026\ {\rm (exp)} \pm 0.024\ {\rm (model)}$~fm is relatively thin yet consistent with many model calculations. The combined CREX and PREX results will have implications for future energy density functional calculations and on the density dependence of the symmetry energy of nuclear matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assembly of the MOLLER Toroidal Magnets at Jefferson Lab

The MOLLER experiment at the Thomas Jefferson National Accelerator Facility (JLab) aims to precisely measure the weak interaction between electrons. This experiment leverages the 12 GeV electron beam and will run for three years. A crucial component of MOLLER is a system of five uniquely shaped water-cooled toroidal magnets. These magnets, possessing seven-fold symmetry, are designed to focus particles by separating electrons scattered off hydrogen in a liquid hydrogen target. The five magnets separate electrons scattered off electrons (Møller scattering) and protons (elastic e-p scattering) within target into approximately circular rings at the detector. Here, this paper presents the assembly process for these five toroidal magnets, detailing critical steps including epoxy application, pin insertion, soldering and brazing, coil assembly, and alignment, all performed to meet stringent magnet specifications. Additionally, it discusses challenges encountered during construction and highlights lessons learned, offering insights for future magnet development projects.

Lamont, Joseph [Thomas Jefferson National Accelera↗

Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The "Measurement of Lepton-Lepton Electroweak Reaction" (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. These magnets generate the magnetic field needed to separate incident beam electrons scattered from target electrons (Møller scattering) and protons (elastic e-p scattering) within a liquid hydrogen target. Here, this paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Design and Prototyping of a Novel Toroid Magnet System for the MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment ?Measurement of Lepton-Lepton Electroweak Reaction? (MOLLER) requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for 3 years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. This system of magnets provides the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This paper presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet in the magnet (TM0) to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 have been fabricated by Everson-Tesla Incorporated, PA (USA). The manuscript presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

Kashy, David↗

Multiscale and Multimodal Characterization of 2D Titanium Carbonitride MXene

Here, a comprehensive study on the prototype solid solution phase carbonitride MXene Ti 3 CN is conducted using nuclear magnetic resonance, electron spin resonance, total and quasi-elastic neutron scattering, combined with density functional theory-based electronic structure and molecular dynamic calculations. The combination of experiment and theory lead toward rational atomic structural models of Ti 3 CN. The remnant Al ions from the etching process significantly tune the interlayer spacing, distinct from the more typical MXene, Ti 3 C 2 , prepared similarly. Neutron scattering indicates the surface terminations of Ti 3 CN display high oxygen and fluorine concentrations and rather low hydroxyl and hydrogen concentrations. Calculations show that the structure including both the residual Al ions and mixed surface terminations give the best agreement with the measurements. The water molecules in Ti 3 CN are highly immobile, in strong contrast to those in Ti 3 C 2 . The analysis of the electronic structure suggests that the nitride MXene displays higher conductivity than the carbides. Finally, the absence of hydroxyl groups in terminations, the solid-solution in the anion sites, the remnants within layers, and immobile water altogether make the carbonitrides a unique series in the MXene family, implying a further exploration of their exotic properties and applications in energy storage.

36 MATERIALS SCIENCE↗

Characterization of muon and electron beams in the Paul Scherrer Institute PiM1 channel for the MUSE experiment

The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the properties of the beam line established for pions. We discuss the production processes that generate the electron and muon beams, and the simulations of these processes. Simulations of the π/μ/e beams through the channel using TURTLE and G4beamline are compared. The G4beamline simulation is then compared to several experimental measurements of the channel, including the momentum dispersion at the intermediate focal plane and target, the shape of the beam spot at the target, and timing measurements that allow the beam momenta to be determined. Finally, we conclude that the PiM1 channel can be used for high precision π, μ, and e scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intrinsic Berry curvature driven anomalous Nernst thermopower in the semimetallic Heusler alloy CoFeVSb

Understanding of spin-heat coupling mechanisms and magnetothermoelectric phenomena, including the anomalous Nernst effect (ANE), in emergent quaternary Heusler alloys is of practical importance for applications in thermal management and energy harvesting. Here, we demonstrate an intrinsic Berry curvature mediated anomalous Nernst thermopower in CoFeVSb, which orders magnetically at high temperature ( T C ≈ 850 K ) with a large saturation magnetization of ≈ 2.2 μ B / f . u . at room temperature. We show that the electron-electron elastic and electron-magnon inelastic scattering dominate longitudinal electrical transport at low temperatures ( T ≤ 50 K ), whereas the electron-phonon and electron-magnon scatterings govern it at higher T . The longitudinal thermopower is resulted mainly from the diffusive contribution with a very large longitudinal Seebeck coefficient ( 42 μ V K - 1 at 395 K). The value of the anomalous Nernst coefficient ( S ANE ) for CoFeVSb at room temperature is 0.039 μ V K - 1 which is higher than the compressively strained SrRu O 3 film ( 0.03 μ V K - 1 ) as well as the spin gapless semiconductor CoFeCrGa ( 0.018 μ V K - 1 ). On lowering T , both the ordinary Nernst coefficient and carrier mobility increase but an opposite trend is found for S ANE . Our ab initio simulations reveal the topological semimetallic nature of CoFeVSb with a pair of Weyl points. These Weyl crossings result in a significant contribution to the Berry curvature, leading to an intrinsic anomalous Hall conductivity ( σ x y AHE ) of ≈ 85 S/cm, which matches well with experiment (77 S/cm at 2 K). Our experimental findings and ab initio calculations support the dominance of the intrinsic Berry curvature in the observed ANE. The ratio of σ x y AHE to the transverse anomalous thermoelectric conductivity ( α x y ANE ) shows an increasing trend with T attaining a sizable fraction of k B e ( ≈ 0.35 k B e ) at room temperature.

36 MATERIALS SCIENCE↗

Electroweak observables in neutrino-electron scattering from a muon storage ring

We investigate the sensitivity of a companion neutrino detector situated in the plane of a high-energy, high-intensity muon storage ring to elastic ν μ and ν e scattering on electrons (EνES). Assuming a muon collider with center-of-mass energies of up to 10 TeV, we report sensitivity to the weak couplings g V and g A up to around 0.05% relative error, and sensitivity to the weak mixing angle in the momentum transfer Q ∈ [10 −2 , 2] GeV range up to around 0.03% relative error. EνES measurements with high-energy muon storage rings allow one to directly interrogate the momentum-transfer regime associated with the NuTeV anomaly. This level of precision allows unique sensitivity to the momentum-dependence of sin 2 θ W . We estimate that with the neutrinos from a E μ = 1.5 TeV (or higher) muon collider, the hypothesis that sin 2 θ W does not “run” can be safely ruled out.

electroweak precision physics↗

Spectral function for 4 He using the Chebyshev expansion in coupled-cluster theory

Here, we compute spectral function for 4 He by combining coupled-cluster theory with an expansion of integral transforms into Chebyshev polynomials. Our method allows us to estimate the uncertainty of spectral reconstruction. The properties of the Chebyshev polynomials make the procedure numerically stable and considerably lower in memory usage than the typically employed Lanczos algorithm. We benchmark our predictions with other calculations in the literature and with electron-scattering data in the quasi-elastic peak. The spectral function formalism allows one to extend ab initio lepton-nucleus cross sections into the relativistic regime. This makes it a promising tool for modeling this process at higher-energy transfers. The results we present open the door for studies of heavier nuclei, important for the neutrino oscillation programs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Transverse and Longitudinal Response Functions in 4He(e,e’) for the Range 0.55 GeV/c lte |q right-arrow| lte 1.0 GeV/c

In electron scattering off a nuclear target, the Coulomb sum is defined as the integration of the longitudinal response function RL over the energy loss of the incident electron in the quasi-elastic nucleon knock-out process. The Coulomb Sum Rule states that at sufficient high three-momentum-transfer |q-right arrow|, the Coulomb sum should equal to the total number of protons in the nucleus: SL -> 1. Previously, precision data existed only up to |q-right arrow| = 600 MeV/c due to the limited beam energy used, and one data point existed for |q-right arrow| = 1.14 GeV/c but with limited precision. During Jefferson Lab experiment E05-110, electron scattering cross sections were measured in the quasi-elastic region on 4He, 12C, 56Fe and 208Pb targets at four scattering angles (15deg., 60deg., 90deg., 120deg.). The longitudinal and transverse response functions RL and RT were extracted in the momentum transfer range 0.55 GeV/c lte |q-right arrow| lte 1.0 GeV/c using the Rosenbluth separation method. The Coulomb sum was formed in the same |q-right arrow| range. The focus of this thesis is the extraction of RL,T from the 4He target data. Preliminary results on RL,T and the Coulomb sum SL for 4He will be presented. The Coulomb sum for 4He is found to be in good agreement with previous data, and still indicate quenching (SL < 1) for the |q-right arrow| region measured by this experiment.

Jin, Kai↗