Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High-dimensional Data-driven Energy optimization for Multi-Modal Transit Agencies (HD-EMMA) (Final Technical Report)

Public bus transit services in the U.S. are responsible for at least 19.7 million metric tons of CO 2 emission annually. Electric vehicles (EVs) can have a much lower environmental impact than comparable internal combustion engine vehicles (ICEVs), especially in urban areas. Unfortunately, EVs are also much more expensive than ICEVs. As a result, many public transit agencies can afford only mixed fleets of transit vehicles, consisting of EVs, hybrids (HEVs), and ICEVs. Transit agencies that operate such mixed fleets of vehicles face a challenging optimization problem: these agencies need to decide which vehicles are assigned to serving which transit trips. Since the advantage of EVs over ICEVs varies depending on the route and time of day (e.g., the benefit of EVs is higher in slower traffic with frequent stops and lower on highways), the assignment can have a significant effect on energy use and, hence, environmental impact. Through this project, we have developed reference data about energy collections and constructed a set of machine learning models that can accurately predict the energy consumption for the whole fleet at the level of each trip. We have used these models to develop a scheduling and assignment strategy that can rotate the different vehicle types across the transit agencies’ routes. The optimization algorithm ensures that the vehicles are matched to trips considering weather patterns, expected congestion, and road gradients to minimize the overall energy usage. We list the key observations from our project for other practitioners below. Details are available in the report, and the list of source code and our publications are included in the appendix. 1. We have demonstrated the feasibility of collecting, merging and analyzing large volumes of high-resolution real-world telemetry data from a mixed vehicle fleet. To mitigate the inherent noise of the recorded GPS points, the team developed an algorithm that filters data and maps the points onto a street. The algorithm considers previous and subsequent location measurements and different characteristics of nearby streets to determine how likely the vehicle travels on them. Then, the team segmented the time series into disjoint contiguous samples based on adjacent road segments and repeated the outlier detection and removal. For each data point, the team added features corresponding to elevation changes within the samples, weather features, such as temperature, and traffic data, such as speed ratio between actual speed and free-flow speed. 2. We have developed two forms of machine learning models that be used to understand and analyze the energy operations of a mixed vehicle transit fleet. The micro prediction model provides estimates of instantaneous energy prediction for all types of buses (diesel, hybrid, and electric). Such a model is important in evaluating the energy impacts of real-time bus operation strategies, but it is challenging due to diversified driving cycles of transit buses. The model can help the drivers understand the impact of their driving behaviors and short-term congestions. The macro prediction models estimate average energy consumption across the whole trip considering the features: distance traveled, various road-type features, elevation change, day of the week, time of day, various weather features (temperature, humidity, etc.), and traffic features (speed ratio and jam factor). 3. We have demonstrated that it is possible to transfer the machine learning models we have developed in this project to other teams and cities by using inductive transfer learning. We also showed that the performance of the macro energy prediction models can be improved using a multi-task learning approach where the learning parameters are shared between the models being developed for different vehicle types. The advantage of this approach is improved learning performance as the models can exploit common spatio-temporal and environmental characteristics. 4. Finally, we have developed trip and vehicle assignment and scheduling algorithms that use the energy prediction models and develop a trip to vehicle type (diesel, electric, hybrid) assignment for the whole operation to reduce overall emissions and cost. We have shown through simulations that the proposed algorithms can save $\$$ 48,910 in energy costs and 175 metric tons of CO 2 emission annually for CARTA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SunLine Transit Agency American Fuel Cell Bus Progress Report (Jan 2017-Jul 2019)

This report presents results of the American Fuel Cell Bus (AFCB) project, a deployment of fuel cell electric buses (FCEBs) operating in the Coachella Valley area of California. The prototype AFCB, which was developed as part of the Federal Transit Administration’s National Fuel Cell Bus Program, was put in revenue service in mid-December 2011. This report is focused on the upgraded design buses, which include two FCEBs delivered in June/July of 2014, one delivered in February 2015, and five delivered in 2018. The project team is collaborating with the U.S. Department of Energy (DOE) and DOE’s National Renewable Energy Laboratory to evaluate the buses in revenue service. This final report on the AFCBs updates the data through July 2019.

33 ADVANCED PROPULSION SYSTEMS↗

Fabrication of the Fermilab Pre-Series Cold Mass for the HL-LHC Accelerator Upgrade Project

Fermilab is fabricating ten full length cold masses for the high-luminosity Large Hadron Collider Accelerator Upgrade Project (HL-LHC AUP). One practice assembly and one pre-series assembly have been completed. Here this paper summarizes the construction details. Topics include incoming inspection, bus assembly, component machining, shell forming, beam tube insertion, bus expansion loop installation, instrumentation installation, electrical testing, heat exchanger installation and final assembly welding. In-process surveys, alignment measurements and testing are presented and explained. Problems encountered during construction and their solutions are discussed.

43 PARTICLE ACCELERATORS↗

Real-Time Modal Analysis of Electric Power Grids - The Need for Dynamic State Estimation

We articulate the reason why dynamic state estimation is needed to push the boundaries of the modal analysis of electric power grids in real-time operation. Then, we demonstrate how to unravel linear and nonlinear modes by using the extended dynamic mode decomposition along with estimates of the synchronous generators’ rotor angles and rotor speed deviations from nominal speed. The estimated modes are associated with electromechanical oscillations that take place continuously in electric power grids because of imbalances between power generation and demand. The numerical simulations are performed on a synthetic, albeit realistic, 2,000-bus network that was designed to resemble the electric power grid of Texas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Time Modal Analysis of Electric Power Grids - The Need for Dynamic State Estimation: Preprint

We articulate the reason why dynamic state estimation is needed to push the boundaries of the modal analysis of electric power grids in real-time operation. Then, we demonstrate how to unravel linear and nonlinear modes by using the extended dynamic mode decomposition along with estimates of the synchronous generators' rotor angles and rotor speed deviations from nominal speed. The estimated modes are associated with electromechanical oscillations that take place continuously in electric power grids because of imbalances between power generation and demand. The numerical simulations are performed on a synthetic, albeit realistic, 2,000-bus network that was designed to resemble the electric power grid of Texas.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluating the current perceived cost of ownership for buses and trucks in China

Decarbonizing commercial vehicles, including buses, trucks, and special purpose vehicles, is essential for China to achieve its carbon neutrality target by 2060. However, understanding the adoption barriers of alternative fuel technologies for commercial vehicles has largely been limited to the total cost of ownership approach that mainly considers tangible costs. Additionally, this study proposes a perceived cost of ownership (PCO) model, which monetizes both tangible and implicit costs, including charging annoyance for buses and trucks by size and classification under different use scenarios. In the case study for China's current bus and truck market, the PCO of alternative fuel technologies, such as battery electric vehicles (BEVs) and fuel cell electric vehicles (FCEVs) are 27%–129% and 31%–86% higher than the most economically competitive powertrains – the compressed natural/liquefied petroleum gas technology and hybrid electric technology. BEVs could be cost-effective in the mini/midsize bus segment or in the daily short-distance driving scenario, and FCEVs could firstly be deployed in cities with a low hydrogen price. Though the implicit costs caused by range anxiety and charging annoyance account for at least 27% of BEV's PCO, making BEV uncompetitive, the battery swapping technique could reduce the implicit cost and overall cash outflow for BEV owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Riders’ perceptions towards transit bus electrification: Evidence from Salt Lake City, Utah

While battery electric buses (BEBs) can lead to energy savings and reduced emissions, BEB adoption is developing slowly. Although BEBs offer quieter operations, better acceleration, and no smell of diesel or gas fumes, little focus has been placed on the user’s perspective. Here, this study investigates bus riders’ preferences toward BEBs. To achieve these objectives, a survey was designed and administered to solicit riders’ typical travel behaviors and patterns as well as preferences and opinions about BEBs’ performance in terms of emissions and noise. Statistical analysis showed that several factors influence rider perceptions towards transit bus electrification that include trip purpose, attitudes towards environmental issues and environmental impacts of BEBs, and certain non-instrumental ride factors such as ride comfort and social image. A better understanding of the importance of electrification to transit riders can help transit service providers adjust their marketing decisions and their systemwide operations to accommodate preferences towards BEBs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Si/SiGe QuBus for single electron information-processing devices with memory and micron-scale connectivity function

The connectivity within single carrier information-processing devices requires transport and storage of single charge quanta. Single electrons have been adiabatically transported while confined to a moving quantum dot in short, all-electrical Si/SiGe shuttle device, called quantum bus (QuBus). Here we show a QuBus spanning a length of 10 μm and operated by only six simply-tunable voltage pulses. We introduce a characterization method, called shuttle-tomography, to benchmark the potential imperfections and local shuttle-fidelity of the QuBus. The fidelity of the single-electron shuttle across the full device and back (a total distance of 19 μm) is (99.7 ± 0.3) %. Using the QuBus, we position and detect up to 34 electrons and initialize a register of 34 quantum dots with arbitrarily chosen patterns of zero and single-electrons. The simple operation signals, compatibility with industry fabrication and low spin-environment-interaction in 28 Si/SiGe, promises long-range spin-conserving transport of spin qubits for quantum connectivity in quantum computing architectures.

97 MATHEMATICS AND COMPUTING↗

Secondary Frequency Regulation from Variable Generation through Uncertainty Decomposition: An Economic and Reliability Perspective

The rapid integration of variable generation (VG), such as photovoltaics (PV), necessitates an increase in the secondary frequency regulation (SFR) to handle the system intra-dispatch interval imbalance because of VG's variation. Although PV has the control capability to provide SFR, the main challenge is in guaranteeing the delivery of PV's energy and SFRs capacities in the automatic generation control (AGC) within each dispatch interval considering its uncertainty. This paper proposes a deliverable VG SFR provision model with endogenous VG's power uncertainty decomposition. First, the uncertainty of VG is decomposed using distributionally robust chance constraints through which the deliverable SFR provision is guaranteed. Next, the intra-interval frequency response of PV's SFR is validated with a user defined AGC model including the PV power plant. Finally, the economic benefits and the reliability improvements such as the frequency deviation reduction with PV providing SFRcan be integrated and evaluated. The proposed model is tested in a modified 18-bus system and in the Western Electricity Coordinating Council test system. Results demonstrate that with the deliverable SFR from PV, the system cost and the frequency reliability can be improved simultaneously. PV's SFR performance can be guaranteed with the proposed model.

14 SOLAR ENERGY↗

Operational Resilience of Nuclear-Renewable Integrated-Energy Microgrids

The increasing prevalence and severity of wildfires, severe storms, and cyberattacks is driving the introduction of numerous microgrids to improve resilience locally. While distributed energy resources (DERs), such as small-scale wind and solar photovoltaics with storage, will be major components in future microgrids, today, the majority of microgrids are backed up with fossil-fuel-based generators. Small modular reactors (SMRs) can form synergistic mix with DERs due to their ability to provide baseload and flexible power. The heat produced by SMRs can also fulfill the heating needs of microgrid consumers. This paper discusses an operational scheme based on distributed control of flexible power assets to strengthen the operational resilience of SMR-DER integrated-energy microgrids. A framework is developed to assess the operational resilience of SMR-DER microgrids in terms of system adaptive real-power capacity quantified as a response area metric (RAM). Month-long simulation results are shown with a microgrid developed in a modified Institute of Electrical and Electronics Engineers (IEEE)-30 bus system. The RAM values calculated along the operational simulation reflect the system resilience in real time and can be used to supervise the microgrid operation and reactor’s autonomous control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Substation-Level Grid Topology Optimization Using Bus Splitting

Operations of substation circuit breakers are important for maintenance needs and topology reconfiguration in power systems. Bus splitting is one type of topology change where the two bus bars at a substation can become electrically disconnected under certain actions of circuit breakers. Because these events involve detailed substation modeling, they are typically not considered in routine power system operation and control. In this paper, an improved substation-level topology optimization framework is developed by expanding traditional line switching decisions by breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bilinear terms in the resultant optimization problem to linear inequality constraints. Thus, a tractable mixed-integer linear program reformulation is attained that allows for efficient solutions in real-time operations. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the computational performance and economic benefits of the proposed topology optimization approach.

bus split↗

Energy and Emission Prediction for Mixed-Vehicle Transit Fleets Using Multi-task and Inductive Transfer Learning

Public transit agencies are focused on making their fixed-line bus systems more energy efficient by introducing electric (EV) and hybrid (HV) vehicles to their fleets. However, because of the high upfront cost of these vehicles, most agencies are tasked with managing a mixed-fleet of internal combustion vehicles (ICEVs), EVs, and HVs. In managing mixed-fleets, agencies require accurate predictions of energy use for optimizing the assignment of vehicles to transit routes, scheduling charging, and ensuring that emission standards are met. The current state-of-the-art is to develop separate neural network models to predict energy consumption for each vehicle class. Although different vehicle classes’ energy consumption depends on a varied set of covariates, we hypothesize that there are broader generalizable patterns that govern energy consumption and emissions. In this paper, we seek to extract these patterns to aid learning to address two problems faced by transit agencies. First, in the case of a transit agency which operates many ICEVs, HVs, and EVs, we use multi-task learning (MTL) to improve accuracy of forecasting energy consumption. Second, in the case where there is a significant variation in vehicles in each category, we use inductive transfer learning (ITL) to improve predictive accuracy for vehicle class models with insufficient data. As this work is to be deployed by our partner agency, we also provide an online pipeline for joining the various sensor streams for fixed-line transit energy prediction. Here, we find that our approach outperforms vehicle-specific baselines in both the MTL and ITL settings.

97 MATHEMATICS AND COMPUTING↗

Power System Recovery Coordinated with (Non-)Black-Start Generators

Power restoration is an urgent task after a black-out, and recovery efficiency is critical when quantifying system resilience. Multiple elements should be considered to restore the power system quickly and safely. This paper proposes a recovery model to solve a direct-current optimal power flow (DCOPF) based on mixed-integer linear programming (MILP). Since most of the generators cannot start independently, the interaction between black-start (BS) and non-black-start (NBS) generators must be modeled appropriately. The energization status of the NBS is coordinated with the recovery status of transmission lines, and both of them are modeled as binary variables. Also, only after an NBS unit receives the cranking power through connected transmission lines, will it be allowed to participate in the following system dispatch. The amount of cranking power is estimated as a fixed proportion to the maximum generation capacity. The proposed model is validated on several test systems, as well as a 1393-bus representation system of the Puerto Rican electric power grid. Test results demonstrate how the recovery of NBS units and damaged transmission lines can be optimized, resulting in an efficient and well-coordinated recovery procedure.

Zhao, Meng↗

DC-Ripple-Energy Adaptive-Minimization (DREAM) Modulation Scheme for a High Power Density Inverter

The DC bus capacitor is one of the major power-density and reliability hurdles of electric drive systems. It is hard to shrink because it is constrained by the DC bus RMS ripple current, which is only load dependent. A dual-inverter based segmented drive can reduce the ripple current by ~50% compared to a non-segmented case. This paper analyzes the origin of this ripple current and points out the path for minimization. An optimal DC-ripple-energy adaptive-minimization (DREAM) modulation method is proposed to further reduce the ripple current. It is observed in experimental results that the proposed method can achieve additional 38% reduction over the traditional segmented drive system.

Xue, Lincoln↗

Electrifying Transit: A Guidebook for Implementing Battery Electric Buses

This guidebook is organized to give transit decision-makers and relevant stakeholders an overview of BEB facts, data, and considerations important for planning their implementation in a variety of jurisdictions. First, the benefits and barriers for BEB are identified. Second, BEB basics in terms of the major components, including a) the bus, b) the battery, and c) the numerous charging options. BEB introduces new, high demand loads as the buses are charging and thus have a number of interactions with the electricity grid and the utility, which are explored third. Operation and maintenance of BEBs are considered fourth as BEBs should not be operated and maintained in the same approach as diesel buses. Fifth, the costs of BEB prices are summarized – and the choices of bus and battery are explored in how they impact BEB prices. Funding and financing options that support BEBs and their charging stations are also explored. Safety is a key consideration for BEBs and the guidebook touches upon codes and standards, hazards, and emergencies. The final section examines project execution, bringing together information from all the other sections so that long-term planning, route analysis, and fleet and infrastructure planning can be considered in the preparation of BEB deployment, and then deployment can be evaluated on a regular basis. A final conclusion revisits the information covered in the guidebook.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Integrated Assessment of a G3 GMD Event on Large-Scale Power Grids: From Magnetometer Data to Geomagnetically Induced Current Analysis

Solar activities can cause geomagnetic disturbances (GMDs) that give rise to geomagnetically induced currents (GICs) which may compromise the reliability of the power system. In order to build more reliable models representing GMD interactions with the power grid, the power system’s detailed electrical model must be considered along with fluctuations in the earth’s magnetic and induced surface electric fields. Here, this study investigates the impact of incorporating spatially varying magnetic fields into surface electric field models on GMD risk metrics. A spatially independent magnetic field model and a spatially varying model are compared through simulations. To perform this analysis, the earth’s magnetic field disturbances are transformed into surface electric fields using respective one-dimensional earth conductivity models. Then, the modeling impact of these electric fields is studied using a 2,000-bus grid for Texas and a 25,000-bus grid for the northeast and mid- Atlantic regions of the United States. Simulation results reveal that the inclusion of spatially varying magnetic fields results in considerable differences in GMD risk metrics, highlighting the importance of accounting for spatial variability when assessing GMD risks in the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrifying Education: Insights into Charging Electric School Buses in the United States

School buses (SBs) have historically been a source of both greenhouse gas emissions and local air pollutants have negative health impacts for students and others living nearby. Battery electric SBs (ESBs) are a promising emerging technology for decarbonizing student transport, however, ESB adoption in the U.S. remains at an early stage (approximate 1.1%) with many outstanding uncertainties. In this study, we take inventory of the current SB stock within U.S. states and observe real-world SB operating profiles to better understand the potential battery range requirements, daily charging opportunities, and charging infrastructure needs for ESBs.

ADVANCED PROPULSION SYSTEMS↗