Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical connectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Data Base On Cables And Connectors

Report describes Connector Adapter Cable Information Data Base (CONNAID) computer program, managing data base containing necessary information concerning electrical connectors, breakout boxes, adapter cables, backshells, and pertinent torque specifications for engineering project.

Bowen, Arlen R.↗

Rugged microelectronic module package supports circuitry on heat sink

Rugged module package for thin film hybrid microcircuits incorporated a rigid, thermally conductive support structure, which serves as a heat sink, and a lead wire block in which T-shaped electrical connectors are potted. It protects the circuitry from shock and vibration loads, dissipates internal heat, and simplifies electrical connections between adjacent modules.

Johnson, A. L.↗

Spline screw multiple rotations mechanism

A system for coupling two bodies together and for transmitting torque from one body to another with mechanical timing and sequencing is reported. The mechanical timing and sequencing is handled so that the following criteria are met: (1) the bodies are handled in a safe manner and nothing floats loose in space, (2) electrical connectors are engaged as long as possible so that the internal processes can be monitored throughout by sensors, and (3) electrical and mechanical power and signals are coupled. The first body has a splined driver for providing the input torque. The second body has a threaded drive member capable of rotation and limited translation. The embedded drive member will mate with and fasten to the splined driver. The second body has an embedded bevel gear member capable of rotation and limited translation. This bevel gear member is coaxial with the threaded drive member. A compression spring provides a preload on the rotating threaded member, and a thrust bearing is used for limiting the translation of the bevel gear member so that when the bevel gear member reaches the upward limit of its translation the two bodies are fully coupled and the bevel gear member then rotates due to the input torque transmitted from the splined driver through the threaded drive member to the bevel gear member. An output bevel gear with an attached output drive shaft is embedded in the second body and meshes with the threaded rotating bevel gear member to transmit the input torque to the output drive shaft.

Vranish, John M.↗

Checking Fits With Digital Image Processing

Computer-aided video inspection of mechanical and electrical connectors feasible. Report discusses work done on digital image processing for computer-aided interface verification (CAIV). Two kinds of components examined: mechanical mating flange and electrical plug.

Davis, R. M.↗

Clamp provides efficient connection for high-density currents

Electrical connector clamp /bus bar/ gives high contact-surface efficiency for providing a high current to thin wall stainless steel tubing containing hydrogen gas. It uses lead solder film to provide the electrical equivalent of a fusion bond without degrading the grain structure, permitting disassembly and reuse of the components.

Mc Carthy, J. R.↗

Dust Tolerant Connectors

Methods and systems may provide for debris exclusion and removal apparatuses for connectors which have inverting end caps with a multi-axis lever configuration, inverting end caps with enlarged handle and/or side rail configurations, rotating end cap configurations, poppet valve configurations, O-ring configurations, filament barrier configurations, retractable cover configurations, clamshell end cap configurations, or any combination thereof. Apparatuses may also provide for an intelligent electrical connector system capable of detecting damage to or faults within a plurality of conductors and then rerouting the energy through a non-damaged spare conductor.

Mueller, Robert P.↗

Making Macroscopic Assemblies of Aligned Carbon Nanotubes

A method of aligning and assembling single-wall carbon nanotubes (SWNTs) to fabricate macroscopic structures has been invented. The method entails suspending SWNTs in a fluid, orienting the SWNTs by use of a magnetic and/or electric field, and then removing the aligned SWNTs from suspension in such a way as to assemble them while maintaining the alignment. SWNTs are essentially tubular extensions of fullerene molecules. It is desirable to assemble aligned SWNTs into macroscopic structures because the common alignment of the SWNTs in such a structure makes it possible to exploit, on a macroscopic scale, the unique mechanical, chemical, and electrical properties that individual oriented SWNTs exhibit at the molecular level. Because of their small size and high electrical conductivity, carbon nanotubes, and especially SWNTs, are useful for making electrical connectors in integrated circuits. Carbon nanotubes can be used as antennas at optical frequencies, and as probes in scanning tunneling microscopes, atomic-force microscopes, and the like. Carbon nanotubes can be used with or instead of carbon black in tires. Carbon nanotubes are useful as supports for catalysts. Ropes of SWNTs are metallic and, as such, are potentially useful in some applications in which electrical conductors are needed - for example, they could be used as additives in formulating electrically conductive paints. Finally, macroscopic assemblies of aligned SWNTs can serve as templates for the growth of more and larger structures of the same type. The great variety of tubular fullerene molecules and of the structures that could be formed by assembling them in various ways precludes a complete description of the present method within the limits of this article. It must suffice to present a typical example of the use of one of many possible variants of the method to form a membrane comprising SWNTs aligned substantially parallel to each other in the membrane plane. The apparatus used in this variant of the method (see figure) includes a reservoir containing SWNTs dispersed in a suspending agent (for example, dimethylformamide) and a reservoir containing a suitable solvent (for example, water mixed with a surfactant). By use of either pressurized gas supplied from upstream or suction from downstream, the suspension of SWNTs and the solvent are forced to mix and flow into a tank. A filter inside the tank contains pores small enough to prevent the passage of most SWNTs, but large enough to allow the passage of molecules of the solvent and suspending agent. The filter is oriented perpendicular to the flow path. A magnetic field parallel to the plane of the filter is applied. The success of the method is based on the tendency of SWNTs to become aligned with their longitudinal axes parallel to an applied magnetic field. The alignment energy of an SWNT increases with the length of the SWNT and the magnetic-field strength. In order to obtain an acceptably small degree of statistical deviation of SWNTs of a given length from alignment with a magnetic field, one must make the field strong enough so that the thermal energy associated with rotation of an SWNT away from alignment is less than the alignment energy.

Smalley, Richard E.↗

Release mechanism for releasing and reattaching experiments on the Space Shuttle

The release mechanism (REM) unlatches an experiment so that it can be moved about inside and outside the shuttle bay by the remote manipulator system (RMS), and then reattaches it to the REM base. Operated from the crew compartment after the RMS has been attached to the experiment, the REM releases the experiment by an electric motor driving a gear train and linkage which extracts four pins from holes in four plates. Electrical connectors on the REM are disengaged by the mechanical action of the structural pins retracting from the plates. When the REM releases the experiment, an unlatched indicator is actuated in the crew compartment, and then the experiment can be moved by using the RMS. To reattach the experiment to the REM, the RMS places the experiment with REM attachment angles against the flat, smooth surface of the REM; then the RMS moves the experiment into position for latchup. Actuation of an electric motor drives the four pins into the four holes in the plates. When fully latched, a switch actuated by the motion of the linkage, shuts the electric motor off and gives an indication to the crew compartment that the REM is latched.

Clark, A. V.↗

Flammability control for electrical cables and connectors

Technique of covering fire-hazardous sections of electrical wiring with fireproof materials prevents fires from spreading in oxygen-enriched atmospheres and eliminates use of heavy metal enclosures. Materials used to cover potting on connectors and ground terminals are made from Teflon-coated Beta cloth and Fluorel, a nonflammable fully-saturated polymer.

Wick, W. O.↗

An improved method for electrical cable terminations

Method utilizes a standard terminal lug, a braided wire passed through the barrel and overlapping the top of the lug, and a ferrule to clamp the end of the wire. Electrical connectors can be sterilized and visibly inspected for reliability.

Baker, C. D.↗

Coupling device

Releasable coupling device designed to receive and retain matching ends of electrical connectors

Tucker, E. M.↗

Flexible electrical conductors for high-temperature switchgear

Arch-shaped conductors fabricated from flat strips of beryllium oxide dispersion-strengthened copper alloy serve as flexible electrical connectors capable of operating in 1000 deg F temperature range, under vacuum conditions for periods of 10,000 hours or more without failure.

Koutnik, E. A.↗

Electrical grounding bracket

Device serves as common grounding point for shielded wires of multipin electrical connector and permits addition or removal of ground leads without disturbing other grounded wires.

Carroll, C. E.↗

Multilayer flat electrical cable

Flat electrical cable is lightweight, flexible over wide temperature range, withstands continuous exposure to high levels of nuclear radiation, and can carry high currents with minimum of temperature rise. Its magnetic cleanliness is equal to or better than twisted pair of wires, and it can be terminated in conventional electrical connector.

Silverman, P. G.↗

Safe electrical receptacle and modified plug

Recently-developed electrical receptacle has internal sliding protective cover that prevents accidental contact with live terminals. Sliding protective cover is used in combination with modified male plug. Design provides excellent protector against electrical shock and should interest manufacturers of electrical connectors.

Rabb, L. W.↗

MSFC connector development

NASA flat conductor cable connectors with individually sealed contacts are described. Descriptions of the design, main features, contact spring, connector electrical data, dimensions and weight, FCC termination, and keying system for plug and receptacle are included.

Angele, W.↗