Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Review of Technical Requirements for Inverter-Based Resources in Chile

This document compares the technical requirements in the grid code of Chile (NTSyCS) against the EirGrid (Ireland transmission system operator) and National Grid Electricity System Operator (NESO) grid codes and the Institute of Electrical and Electronics Engineers (IEEE) 2800-2022 standard for conventional inverter technology at the transmission and subtransmission levels in the process of being adopted by system operators in the U.S. The document is intended to be a guide and reference for future updates of the NTSyCS, considering the local system requirements and present improvements in inverter-based resource (IBR) technology. In light of the findings of the aforementioned comparative review, this document proposes and describes the requirements for conventional IBRs that could be incorporated and updated into the Chilean grid code. The document is structured around the main grid challenges posed by the transition to an IBR-dominated grid and conventional IBRs capabilities to help address them. This document does not provide guidance on how this specification should be implemented (e.g., through a mandate or market solution).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Introduction to Microgrids

A microgrid is simply a typical power system that has distributed energy resources (DERs), like small diesel generators, with loads in the network. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. One key factor that differentiates microgrids from a typical distribution grid is its ability to disconnect itself in the event of a blackout and sustain its loads through DERs. Microgrid systems will reconnect to the main grid when the grid comes back up. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. This presentation discusses the typical key steps involved in microgrid planning, installation, operation in a interoperable and interconnectable fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Constrained Electric Vehicle Fast Charging Sites: Battery-Buffered Options

This case study summarizes recent Joint Office of Energy and Transportation technical assistance work performed by the National Renewable Energy Laboratory which involved helping a state department of transportation analyze the feasibility of a battery energy storage system solution at a grid-constrained EV charging location.

ADVANCED PROPULSION SYSTEMS↗

Technical Impacts of Light-Duty and Heavy-Duty Transportation Electrification on a Coordinated Transmission and Distribution System

In this study, we propose a strategy to model the required spatiotemporal charging demand from light-duty (LD) and medium- and heavy-duty (MHD) electric vehicles (EVs) using actual transportation data by mapping the demand for the required EV charging to a realistic and coordinated distribution and transmission electric grid at the predicted times of the day to study their impact on the power system in a variety of load, weather, and EV penetration scenarios. This work is the first study that includes the actual weather data and transportation data with realistic and coordinated distribution and transmission grid data in a large industry-scale level study. The main goal of this study is to identify possible issues and required upgrades in the electric grid, caused by an increase in EV integration. The transmission case study is a large grid with 6717 buses over a Texas footprint, and the distribution grid is over Houston, a city in Texas, covering over three million customers. The resulting overloads and voltage violations experienced in the system are discussed, and required planning upgrades to avoid these issues are suggested.

AC optimal power flow (AC-OPF)↗

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays↗

Resource assessment of ocean thermal energy conversion in Puerto Rico and U.S. Virgin Islands

Island communities often struggle to establish and maintain traditional electric grids and are therefore heavily reliant on costly imported fossil fuels. In the case of Puerto Rico, these challenges are enhanced by extreme weather and other natural hazards that threaten the local electricity generation and transmission infrastructure. Ocean thermal energy conversion (OTEC) could play an important role in establishing a more resilient electrical grid in the region. Here, in this study, a detailed analysis is conducted to characterize the ocean thermal resource and power potential of OTEC in Puerto Rico based on a 14-year dataset of modeled ocean temperature. The assessment considers seasonal and interannual variability in the region's thermal resource and examines the operational limitations associated with minimal thermal gradients required to run a typical OTEC heat engine. Notably, the local thermal resource is found to be sensitive to El Niño-Southern Oscillation (ENSO) climate patterns, with La Niña conditions linked to greater OTEC power availability. Seven areas of opportunity are identified based on their resource potential and proximity to existing electrical distribution lines, including two that could benefit the nearby U.S. Virgin Islands. The greatest OTEC power potential is observed to the south of the main island of Puerto Rico in the Caribbean Sea with an estimated capacity of 138 MW for a plant pumping cold water from a depth of 1,000 m, or the equivalent amount of electricity required to power 219,000 households.

OTEC↗

Data for Carbon-negative Hydrogen: Aqueous Phase Reforming (APR) of Glycerol over NiPt Bimetallic Catalyst Coupled with CO2 Sequestration

Herein we report the production of high-pressure (19.3 bar), carbon-negative hydrogen (H2) from glycerol with a purity of 98.2 mol% H2, 1.8 mol% light hydrocarbons (mainly methane), and 400 ppm of CO. Aqueous phase reforming (APR) of 10 wt% glycerol solution was studied with a series of NiPt alumina bimetallic catalysts supported on alumina. The Ni8Pt1-450 catalyst had the highest hydrogen selectivity (95.6%) and the lowest alkanes selectivity (3.7%) of the tested catalysts. The hydrogen selectivity decreased in the order of Ni8Pt1-450 > Ni8Pt1-260 > Ni1Pt1-260 > Pt-260. The CO2 was sequestered with CaO adsorbent which formed CaCO3. We measured the adsorption capacity of the CaO adsorbent at different temperatures. Life cycle analysis showed that the APR of glycerol coupled with CO2 capture has net negative CO2 equivalent greenhouse gas emissions. The CO2 emissions are −9.9 kg CO2 eq./kg H2 and −50.1 kg CO2 eq./kg H2 when grid electricity and renewable electricity are used, respectively, and the CO2 is allocated respectively to the mass of products produced. The cost of this H2 (denoted as “green-emerald”) was estimated to be 2.4 USD per kg H2 when grid electricity is used and 2.7 USD per kg H2 when using renewable electricity. The cost of glycerol has the highest contribution of 1.71 USD per kg H2. Participation in the carbon credit markets can further decrease the price of the produced H2.

Catalysis↗

Carbon-negative hydrogen: aqueous phase reforming (APR) of glycerol over NiPt bimetallic catalyst coupled with CO 2 sequestration

Herein we report the production of high-pressure (19.3 bar), carbon-negative hydrogen (H 2 ) from glycerol with a purity of 98.2 mol% H 2 , 1.8 mol% light hydrocarbons (mainly methane), and 400 ppm of CO. Aqueous phase reforming (APR) of 10 wt% glycerol solution was studied with a series of NiPt alumina bimetallic catalysts supported on alumina. The Ni 8 Pt 1 -450 catalyst had the highest hydrogen selectivity (95.6%) and the lowest alkanes selectivity (3.7%) of the tested catalysts. The hydrogen selectivity decreased in the order of Ni 8 Pt 1 -450 > Ni 8 Pt 1 -260 > Ni 1 Pt 1 -260 > Pt-260. The CO 2 was sequestered with CaO adsorbent which formed CaCO 3 . We measured the adsorption capacity of the CaO adsorbent at different temperatures. Life cycle analysis showed that the APR of glycerol coupled with CO 2 capture has net negative CO 2 equivalent greenhouse gas emissions. The CO 2 emissions are –9.9 kg CO 2 eq./kg H 2 and –50.1 kg CO 2 eq./kg H 2 when grid electricity and renewable electricity are used, respectively, and the CO 2 is allocated respectively to the mass of products produced. The cost of this H 2 (denoted as “green-emerald”) was estimated to be 2.4 USD per kg H 2 when grid electricity is used and 2.7 USD per kg H 2 when using renewable electricity. The cost of glycerol has the highest contribution of 1.71 USD per kg H 2 . As a result, participation in the carbon credit markets can further decrease the price of the produced H 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparative assessment of the economic viability of nuclear-integrated direct air capture systems

Direct air capture (DAC) systems require heat and electricity to operate, which can be supplied by nuclear power plants (NPPs). In this study, the performance and cost of various conceptual nuclear-DAC systems are assessed, and their performance is compared with several non-nuclear options. Three nuclear-DAC systems are considered: (1) a liquid solvent direct air capture (L-DAC) system with heat supplied from natural gas (NG) and electricity supplied by an NPP, (2) an electrified L-DAC system, fully powered by electricity from an NPP, and (3) a solid sorbent direct air capture (S-DAC) system utilizing both heat and electricity generated by an NPP. Two nuclear technologies are considered: a pressurized water reactor and a high-temperature gas-cooled reactor. Under the medium conservatism scenario, the levelized cost of direct air capture (LCOD) for these systems range from $\$$310/tCO 2 to $\$$525/tCO 2 with the L-DAC system having an NG heat supply at the lower end of the range, and the electrified L-DAC system and the S-DAC system at the higher end of the range. Coupling with nuclear energy led to a 21 % reduction in LCOD for the L-DAC system with NG heat supply and a 29 % reduction for the S-DAC system when compared to fully NG-powered options. When powering the DAC system with grid electricity, the LCOD is highly dependent on the assumed electricity price and carbon intensity. The nuclear option is the cheaper choice when the price of low-carbon grid electricity exceeds $\$$95/MWh and $\$$45/MWh for the L-DAC and S-DAC systems, respectively.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Techno-Economic Analysis of Compressed Air Energy Storage and Hydrogen Production from Variable Renewable Energy

This study presents the techno-economic analysis (TEA) results of integrating electrolysis hydrogen (H 2 ) production, compressed air energy storage (CAES), and H 2 -fired combustion turbines in a high variable renewable energy (VRE) market environment. The inconsistent nature of VRE creates challenges for power producers in maintaining a stable electrical grid as it is increasingly utilized. The mission of the National Energy Technology Laboratory (NETL) is driving innovation and delivering energy solutions, and a multiangle approach involving H 2 production, energy storage, and next-level H 2 -fired combustion turbine generator (CTG) technologies could provide one solution for the nation’s growing electrical grid issues with increasing VRE sources. The H 2 production and CAES concept were investigated due to its ability to provide utility-scale H 2 -fueled power generation with large-scale energy storage capabilities. Two facilities with CAES and natural gas-fired CTGs (in McIntosh, Alabama, and Huntorf, Germany) have been operating for decades. In contrast, this study investigates the potential to replace the natural gas fuel with H 2 fuel. This concept has been publicly presented by both Siemens Energy and Bechtel Global Engineering, Construction & Project Management (Bechtel) at two different power generating levels. The CAES and air expansion/combustion turbine power generation in this study are primarily based on the Siemens Energy system (Bailie, Aug. 10-11, 2021) (Scheller, Feb. 21, 2023). The inclusion of a H 2 turboexpander generator is from Bechtel (Gülen, Sep. 6, 2022). A block flow diagram of the proposed process is illustrated in Exhibit ES-1.

08 HYDROGEN↗

Wind 2H2 Project (CRADA Final Report)

The Xcel-NREL Wind Electrolysis R&D Project is designed to gain knowledge and insight about producing hydrogen from electricity for use as a vehicle fuel and as a “stored wind”. The project will analyze producing hydrogen directly from wind as well as from the electric grid. In addition, it will look at storing hydrogen and then using it to put electricity back onto the grid. Modifications were made to the original scope to also include electric vehicles integration with the electric grid. This report addresses Task 8 portion of the CRADA, focused on testing and measuring the attributes of plug-in electric vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Change Agent: Energy Storage as a Driver of Regulatory Evolution

Purpose of Review Dividing the electric grid into the functions of generation, transmission, anddistribution enabled the drawing of jurisdictional lines and the application of the U.S.Constitution’s federalist system to energy regulation. Energy storage technologies,which can be placed throughout the grid to increase flexibility, can provide serviceacross all three of those functions. But the jurisdictional boundaries that have beendrawn around those functions have created barriers that restrict energy storagetechnologies from achieving their full potential. This review analyzes regulatory changes made to reduce barriers to storage deployment and their broader impacts on energy regulation in the U.S. Recent Findings Major energy regulations promulgated at the state and federal levels have generally focused on liberalizing the U.S. electric system through deregulation and increased competition. Paradoxically, however, these efforts have erected strict regulatory barriers that prevent energy storage technologies from providing service across multiple functions. A new wave of regulations in recent years has endeavored to reduce and remove those barriers. Summary Energy regulations adopted in recent years to reduce barriers to energy storage functionality in recent years have had deep and far-reaching impacts on U.S. electric regulation. These impacts go beyond storage and affect all energy technologies. This paper traces the development of energy regulation in U.S., the functional barriers that they created that impede energy storage functionality, recent efforts to remove those barriers, and the broader effects of those efforts. It concludes with a brief discussion of remaining barriers that prevent energy storage from reaching their full potential on the U.S. electric grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Infrastructure Futures: A Multiscale Evaluation of Projected Power Plant Siting Across the Western Interconnection

The US Western Interconnection is facing unprecedented challenges in the form of less predictable peak demand, increasingly diverse generating resources, and fast-growing loads due to the onset of artificial intelligence, hyperscale computing, and electrification. Projecting where future generation may be developed is critical to maintaining a robust and resilient electric grid under this mounting uncertainty and variability. Using an integrated multisectoral, multiscale modeling framework that links a human-Earth systems model, an hourly load model, a geospatial power plant siting model, and an hourly grid operations model, we evaluate the power plant landscape evolution under eight alternative futures between 2020 and 2055. These futures represent a wide but plausible range of atmospheric conditions, emissions constraints, and economic, technological, and population growth assumptions. We find that local-level development can vary substantially both by generation type and capacity buildout across these futures. Specific regions of the Western Interconnection are projected to see large amounts of capacity development regardless of the future scenario. We additionally determine that projected power plant locations are more heavily influenced by the cost to interconnect to the electric grid than the locational energy value.

Mongird, Kendall↗

Assessment of Technoeconomic Opportunities in Automation for Nuclear Microreactors

Achieving full decarbonization of all economic sectors remains a challenge, especially in niche markets. For example, remote communities and industrial or mining activities detached from the main electric grid heavily rely on fossil fuels, similar to urban and industrial microgrids with combined heat and power needs. A combination of renewables and energy storage is often not suitable due to cost, reliability, intermittency, and large storage requirements. Small nuclear reactors with a flexible purpose could serve these applications. Microreactors (MR) are a class of reactors that are compact, factory manufactured, transportable, and self-regulating. Typically, they generate much less power than their large reactor counterparts. The main advantages of microreactors include the versatile nature of the energy produced, the reliability of supply, and freedom from having to transport and store large quantities of fuels on-site, coupled with the absence of dependence on an electrical grid. A strong business case is needed to move from the microreactor prototype to the commercialization phase. In fact, fossil fuels are still relatively inexpensive, and in the near term, carbon credits will be available to virtually compensate for emissions. For microreactors, one of the main costs in operation and maintenance (O&M) is their staffing levels. In this study, we investigate how to optimize the number (and thus the cost) of workers, moving from a traditional, fully manned, on-site personnel approach to an unmanned, remote personnel approach. We examine four different staffing models that can be implemented as the technology matures and evolves. We estimate the staffing needs of each model and build a business case to justify the substitution of on-site personnel with adequate technologies. To do so, we propose a cost model to quantify potential cost reductions from automating O&M activities. The model accounts for both the reduction in cost derived from the reduced number of full-time-equivalent (FTE) employees and the increase in cost derived from the need to buy new control hardware as needed. Applying the cost model that we created to different scenarios, an on-site O&M cost reduction exceeding 80% can be expected. Additionally, we found that it is more impactful to focus on automating routine O&M tasks rather than attempting to automate transient management (shutdowns, restarts, monitoring condition deviations). In fact, transients typically account for less than 1% of the total FTE time spent on the reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DEReliction: A Cybersecurity Vulnerability Assessment Methodology for Distributed Energy Resources

With the increasing integration of Distributed Energy Resources (DER) into the electric grid, maintaining grid reliability and resilience requires that these devices remain secure. This paper discusses a cybersecurity vulnerability assessment methodology that incorporates best practices from Sandia National Laboratories, SANS Institute, OWASP Foundation, and other web and Internet of Things (IoT) penetration testing (“pen testing”) programs, courses, and frameworks for assessing the security posture of devices. The methodology involves five sequential steps: (1) Collect Public Information, (2) Extract Hardware Details, (3) Inventory Software Components, (4) Identify Vulnerabilities, and (5) Test Vulnerabilities. Each step uncovers potential weaknesses in both hardware and software components of DER devices, considering adversary tactics, techniques, and procedures (TTPs), and potential attack vectors along the way. The results from the execution of this method on multiple residential- and small commercial-scale photovoltaic (PV) inverters reveled hardware and software vulnerabilities, which highlight the benefit of taking a methodical approach to discover vulnerabilities. While the specific vulnerability details are not shared here, a generalized overview of findings underscore the importance of robust security assessments for DER devices. Adoption of an assessment framework of this kind will identify and mitigate cybersecurity threats and bolster the resilience of DER-integrated electric grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Clustering and Classification of Outage Patterns with Insights into their Links to Extreme Events

At a global level extreme events have increased in both scale and impact. These events have the potential to affect the electrical grid infrastructure and cause a wide range of outages, which can lead to a disruption in daily patterns, cost millions of dollars and also the loss of life. Currently, to track these outage events there have been various approaches developed ranging from regional to national level quantifications for what defines an outage. However, this variation in methods can potentially lead to subjective decision-making and a lack of proper management in relation to the event. While previous work has made strides in determining spatio-temporal patterns, minimal attention has been given to the type and number of outages an area may be exposed to. The differences in incurred cost and the overall severity of an event between a transformer box malfunction and a hurricane are drastic, and by finding historical signals, we can allow for more efficient management, potentially saving lives and millions of dollars. Here, we leverage unsupervised machine learning techniques to delineate outage patterns among 22 counties within the United States and find that there are clear, segregated clusters (0.93 silhouette) of data which are related by event behavior and underlying cause. This finding will allow for energy stakeholders, policy makers, and researchers to gain a deeper understanding of the extent and severity of historic events and to better prepare for electrical grid infrastructure planning and management.

Koob, Benjamin [ORNL]↗

A Model Predictive Control to Improve Grid Resilience

The following article details a model predictive control (MPC) to improve grid resilience when faced with variable generation resources. This topic is of significant interest to utility power systems where distributed intermittent energy sources will increase significantly and be relied on for electric grid ancillary services. Previous work on MPCs has focused on narrowly targeted control applications such as improving electric vehicle (EV) charging infrastructure or reducing the cost of integrating Energy Storage Systems (ESSs) into the grid. In contrast, this article develops a comprehensive treatment of the construction of an MPC tailored to electric grids and then applies it integration of intermittent energy resources. To accomplish this, the following article includes a description of a reduced order model (ROM) of an electric power grid based on a circuit model, an optimization formulation that describes the MPC, a collocation method for solving linear time-dependent differential algebraic equations (DAEs) that result from the ROM, and an overall strategy for iteratively refining the behavior of the MPC. Next, the algorithm is validated using two separate numerical experiments. First, the algorithm is compared to an existing MPC code and the results are verified by a numerically precise simulation. It is shown that this algorithm produces a control comparable to existing algorithms and the behavior of the control carefully respects the bounds specified. Second, the MPC is applied to a small nine bus system that contains a mix of turbine-spinning-machine-based and intermittent generation in order to demonstrate the algorithm’s utility for resource planning and control of intermittent resources. This study demonstrates how the MPC can be tuned to change the behavior of the control, which can then assist with the integration of intermittent resources into the grid. The emphasis throughout the paper is to provide systematic treatment of the topic and produce a novel nonlinear control compatible design framework applicable to electric grids and the control of variable resources. This differs from the more targeted application-based focus in most presentations.

microgrid↗