Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Interrogation of Electrochemical Properties of Polymer Electrolyte Thin Films with Interdigitated Electrodes

The ability to characterize bulk and interfacial transport properties of polymer electrolytes is critical to realizing their potential applications in electrochemical energy storage devices. In this paper, we leverage custom microfabricated interdigitated electrode array (IDEs) as a platform to probe ion transport properties of polymer electrolytes films through electrochemical impedance spectroscopy (EIS) measurements. Using poly(ethylene oxide) (PEO) blended with lithium bis(trifluoromethanesulfonyl) imide (LiTFSI) as a model dry polymer electrolyte system, we investigate how geometric parameters of the IDEs influence the quality and analysis of EIS measurements. By focusing on films on the nanometer film thickness (ca. 50 nm), EIS measurements revealed diffusional processes near the electrode/polymer interface that may be difficult to observe with conventional thick films. Moreover, irreversible impedance spectra were observed at elevated temperatures when using IDEs with large electrode metal fractions. These irreversible processes were eliminated through passivation of the IDE with different oxides (SiO 2 , Al 2 O 3 , or TiO 2 ). Ultimately, the ionic conductivity of PEO-LiTFSI electrolytes is confidently determined when appropriate IDE geometries and equivalent circuits are used. Lastly, our work demonstrates the use of IDEs and nanothin polymer electrolytes films as a versatile platform for rapid and efficient interrogation of both bulk and interfacial electrochemical properties.

36 MATERIALS SCIENCE↗

Multifunctional bulk plasma source based on discharge with electron injection

A bulk plasma source, based on a high-current dc glow discharge with electron injection, is described. Electron injection and some special design features of the plasma arc emitter provide a plasma source with very long periods between maintenance down-times and a long overall lifetime. The source uses a sectioned sputter-electrode array with six individual sputter targets, each of which can be independently biased. This discharge assembly configuration provides multifunctional operation, including plasma generation from different gases (argon, nitrogen, oxygen, acetylene) and deposition of composite metal nitride and oxide coatings.

36 MATERIALS SCIENCE↗

Groundwater characterization and monitoring at a complex industrial waste site using electrical resistivity imaging

A contaminated industrial waste site in Washington State (USA) containing buried, metallic-waste storage tanks, pipes, and wells, was evaluated to determine the feasibility of monitoring groundwater remediation activities associated with an underlying perched aquifer system using electrical resistivity tomography. The perched aquifer, located ~65 m below ground surface and ~10 m above the regional water table, contains high concentrations of nitrate, uranium, and other contaminants of concern from past tank leaks and intentional releases of wastes to surface disposal sites. The extent of the perched water aquifer is not well known, and the effectiveness of groundwater extraction for contaminant removal is uncertain, so supplemental characterization and monitoring technologies are being evaluated. Numerical simulations of subsurface flow and contaminant transport were performed with a highly resolved model of the hydrogeologic system and waste site infrastructure, and these simulations were used as the physical basis for electrical resistivity tomography modeling. The modeling explicitly accounted for metallic infrastructure at the site. The effectiveness of using surface electrodes versus surface and horizontal subsurface electrodes, for imaging groundwater extraction from the perched water aquifer, was investigated. Although directional drilling is a mature technology, its use for electrode emplacement in the deep subsurface under a complex industrial waste site via horizontal wells has not yet been demonstrated. Results from this study indicate that using horizontal subsurface electrode arrays could significantly improve the ability of electrical resistivity tomography to image deep subsurface features and monitor remediation activities under complex industrial waste sites.

54 ENVIRONMENTAL SCIENCES↗

Pyroelectric energy harvesting using liquid-based switchable thermal interfaces

The pyroelectric effect offers an intriguing solid-state approach for harvesting ambient thermal energy to power distributed networks of sensors and actuators that are remotely located or otherwise difficult to access. There have been, however, few device-level demonstrations due to challenges in converting spatial temperature gradients into temporal temperature oscillations necessary for pyroelectric energy harvesting. We demonstrate the feasibility of a device concept that uses liquid-based thermal interfaces for rapid switching of the thermal conductance between a pyroelectric material and a heat source/sink and can thereby deliver high output power density. Using a thin film of a pyroelectric co-polymer together with a macroscale mechanical actuator, we operate pyroelectric thermal energy harvesting cycles at frequencies close to 1 Hz. Film-level power densities as high as 110 mW/cm(3) were achieved, limited by slow heat diffusion across a glass substrate. When combined with a laterally interdigitated electrode array and a MEMS actuator, the present design offers an attractive option for compact high-power density thermal energy harvesters. (C) 2012 Elsevier B.V. All rights reserved.

Cha, G↗

Silicon nanomembranes for fingertip electronics

We describe the use of semiconductor nanomaterials, advanced fabrication methods and unusual device designs for a class of electronics capable of integration onto the inner and outer surfaces of thin, elastomeric sheets in closed-tube geometries, specially formed for mounting on the fingertips. Multifunctional systems of this type allow electrotactile stimulation with electrode arrays multiplexed using silicon nanomembrane (Si NM) diodes, high-sensitivity strain monitoring with Si NM gauges, and tactile sensing with elastomeric capacitors. Analytical calculations and finite element modeling of the mechanics quantitatively capture the key behaviors during fabrication/assembly, mounting and use. The results provide design guidelines that highlight the importance of the NM geometry in achieving the required mechanical properties. Furthermore, this type of technology could be used in applications ranging from human–machine interfaces to 'instrumented' surgical gloves and many others.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Global transcriptome profile of the developmental principles of in vitro iPSC-to-motor neuron differentiation

Abstract Background Human induced pluripotent stem cells (iPSC) have opened new avenues for regenerative medicine. Consequently, iPSC-derived motor neurons have emerged as potentially viable therapies for spinal cord injuries and neurodegenerative disorders including Amyotrophic Lateral Sclerosis. However, direct clinical application of iPSC bears in itself the risk of tumorigenesis and other unforeseeable genetic or epigenetic abnormalities. Results Employing RNA-seq technology, we identified and characterized gene regulatory networks triggered by in vitro chemical reprogramming of iPSC into cells with the molecular features of motor neurons (MNs) whose function in vivo is to innervate effector organs. We present meta-transcriptome signatures of 5 cell types: iPSCs, neural stem cells, motor neuron progenitors, early motor neurons, and mature motor neurons. In strict response to the chemical stimuli, along the MN differentiation axis we observed temporal downregulation of tumor growth factor-β signaling pathway and consistent activation of sonic hedgehog, Wnt/β-catenin, and Notch signaling. Together with gene networks defining neuronal differentiation (neurogenin 2, microtubule-associated protein 2, Pax6, and neuropilin-1), we observed steady accumulation of motor neuron-specific regulatory genes, including Islet-1 and homeobox protein HB9. Interestingly, transcriptome profiling of the differentiation process showed that Ca 2+ signaling through cAMP and LPC was downregulated during the conversion of the iPSC to neural stem cells and key regulatory gene activity of the pathway remained inhibited until later stages of motor neuron formation. Pathways shaping the neuronal development and function were well-represented in the early motor neuron cells including, neuroactive ligand-receptor interactions, axon guidance, and the cholinergic synapse formation. A notable hallmark of our in vitro motor neuron maturation in monoculture was the activation of genes encoding G-coupled muscarinic acetylcholine receptors and downregulation of the ionotropic nicotinic acetylcholine receptors expression. We observed the formation of functional neuronal networks as spontaneous oscillations in the extracellular action potentials recorded on multi-electrode array chip after 20 days of differentiation. Conclusions Detailed transcriptome profile of each developmental step from iPSC to motor neuron driven by chemical induction provides the guidelines to novel therapeutic approaches in the re-construction efforts of muscle innervation.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing Rat PNS Electrophysiological Response to Electrical Stimulation Using in vitro Chip-Based Human Investigational Platform (iCHIP)

Ex vivo systems and organ-on-a-chip technology offer an unprecedented approach to modeling the inner workings of the human body. The ultimate goal of LLNL’s in vitro Chip-based Human Investigational Platform (iCHIP) is to integrate multiple organ tissue cultures using microfluidic channels, multi-electrode arrays (MEA), and other biosensors in order to effectively simulate and study the responses and interactions of the major organs to chemical and physical stimulation. In this study, we focused on the peripheral nervous system (PNS) component of the iCHIP system. Specifically we sought to expound on prior research investigating the electrophysiological response of rat dorsal root ganglion cells (rDRGs) to chemical exposures, such as capsaicin. Our aim was to establish a protocol for electrical stimulation using the iCHIP device that would reliably elicit a characteristic response in rDRGs. By varying the parameters for both the stimulation properties – amplitude, phase width, phase shape, and stimulation/ return configuration – and the culture conditions – day in vitro and neural cell types - we were able to make several key observations and uncover a potential convention with a minimal number of devices tested. Future work will seek to establish a standard protocol for human DRGs in the iCHIP which will afford a portable, rapid method for determining the effects of toxins and novel therapeutics on the PNS.

42 ENGINEERING↗

Evaluating the organophosphate NIMP on a 3D-brain-on-a-chip system

In the early 1940s, organophosphates used in insecticides were discovered to act as chemical nerve agents. The most common nerve agents are: isopropyl methylphosphonofluoridate (sarin), ethyl dimethylphosphoramidocyanidate (tabun), and S-2-diisopropylaminoethyl O-ethyl methylphosphonothioate (VX). These nerve agents are responsible for causing acetylcholinesterase (AChE) inhibition which leads to acetylcholine gathering in the synapses. This accumulation causes hyperactivity in the nervous system which causes seizures, bradycardia, respiratory paralysis, and eventually death. For this study, the effects of a sarin chemical surrogate, 4-nitrophenyl isopropyl methylphosphonate (NIMP), was evaluated along with the pre-treatment, pyridostigmine bromide (PB) on 3D cultures of human neurons placed on the novel multi-electrode array (MEA). Neuronal spiking and bursting activity was monitored throughout the experiment and levels of cytotoxicity were determined using the lactate dehydrogenase (LDH) assay. In addition, in-vivo analysis was performed for comparison.

59 BASIC BIOLOGICAL SCIENCES↗

Science & Technology Review June 2019

In collaboration with researchers at the University of California at San Francisco (UCSF), Lawrence Livermore scientists developed a novel system for recording widespread brain activity using highdensity, implantable electrode arrays. The research appears in the January 2, 2019, edition of the journal Neuron. As described in the paper, the system is capable of continuously recording the activity of nearly 400 single neurons over a period of at least five months from devices distributed in multiple brain regions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

An Investigational Platform of the Human Brain for Understanding Complex Neural Function

In this project we focused on developing an experimental model of the human central nervous system that more accurately mirrors the function and physiology of the human brain. This in vitro brain-on-a-chip can provide critical insight into human brain function in response to chemical exposure and disease. To develop a more accurate experimental model, we evaluated and optimized key elements designed to more accurately recapitulate neuron function. We demonstrated that neuronal function was more robust when neurons were cultured with other neuronal cells as well as complex extracellular matrix molecules. We also designed a novel threedimensional multi-electrode array (3DMEA) that provides an unprecedented ability to noninvasively monitor and record neuronal function in 3D in a reproducible manner. We also optimized an experimental model of the blood-brain barrier, providing an important tool for understanding how this interface regulates the exchange of molecules from the blood to the brain. Underpinning all of these experimental efforts were novel data analytics and modeling approaches. The successful completion of this project has positioned LLNL to use our novel tools and expertise to understand human brain function in the context of the Lab’s national security mission.

59 BASIC BIOLOGICAL SCIENCES↗

High-power ultraviolet (UV) and vacuum ultraviolet (VUV) lamps with micro-cavity plasma arrays

A plasma lamp includes plates that are approximately parallel, with at least one array of microcavities formed in a surface of at least one plate. When desirable, the plates are separated a fixed distance by spacers with at least one spacer being placed near the plate's edge to form a hermetic seal therewith. A gas makes contact with the microcavity array. Electrodes capable of delivering a time-varying voltage are located on the surface of each plate. At least one electrode is located on an exterior surface of at least one interior plate. Optionally, protective windows may be placed over the electrodes. The application of the time-varying voltage interacts with the gas to form a glow discharge plasma in the microcavities and the fixed volume between the plates (when present). The glow discharge plasma efficiently and uniformly emits UV/VUV radiation over the entire surface of the lamp.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-power ultraviolet (UV) and vacuum ultraviolet (VUV) lamps with micro-cavity plasma arrays

A product having at least one plasma lamp that includes plates that are approximately parallel, with at least one array of microcavities formed in a surface of at least one plate. When desirable, the plates are separated a fixed distance by spacers with at least one spacer being placed near the plate's edge to form a hermetic seal therewith. A gas makes contact with the microcavity array. Electrodes capable of delivering a time-varying voltage are located such that the application of the time-varying voltage interacts with the gas to form a glow discharge plasma in the microcavities and the fixed volume between the plates. The glow discharge plasma efficiently and uniformly emits radiation that is predominantly in the UV/VUV spectral range with at least a portion of the radiation being emitted from the plasma lamp.

Park, Sung-Jin↗

Near Real-Time Two and Three-Dimensional Electrical Geophysical Monitoring of Natural and Engineered Processes Associated with Subsurface Remediation - 16052

Legacy soil and groundwater contamination associated with nuclear weapons production is projected to be one of the largest cleanup liabilities to the U.S. Department of Energy for the foreseeable future. Remediation of subsurface contaminants is complicated by the combined effects of geochemical heterogeneity, geological heterogeneity, and the difficulty and expense of adequate borehole access. Each of these complications contributes to uncertainty in the distribution of contaminants and the performance of in situ treatments, which increases risk to human health and the environment and cost to closure in general. Electrical resistivity tomography (ERT) is a method of remotely imaging the electrical properties of the subsurface, which are governed by both geochemical and geological structure, thereby providing useful proxies for understanding contaminant distribution and the behavior in situ remediation processes. Recent advancements in both data collection and data processing capabilities are enabling ERT monitoring to be executed and provided to site operators in near real-time. To summarize the process, ERT surveys are rapidly and continuously collected during a time-sensitive operation such as an amendment injection. At the completion of each survey, data are transferred by wireless internet to offsite supercomputing resources for parallel tomographic inversion. Inversion results are then transferred back to onsite operators and/or other locations for visualization. In this paper, we demonstrate the utility of time-lapse ERT for monitoring fluid transport (both gas and liquid phase). We then demonstrate two real-time imaging applications for monitoring both natural and engineered processes at the Hanford Site within the vadose and the saturated zones. We expect this new capability for autonomous real-time imaging to enable ERT to be used as a cost-effective, short-term rapid feedback mechanism for guiding subsurface remediation injections, in addition to longer term monitoring of post-injection performance and environmental impact, all using the same electrode array and instrumentation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implantable neuromodulation system for closed-loop stimulation and recording simultaneously at multiple brain sets

The present disclosure relates to a modular system for deep brain stimulation (DBS) and electrocorticography (ECoG). The system may have an implantable neuromodulator for generating electrical stimulation signals adapted to be applied to a desired region of a brain via an attached electrode array. An aggregator module may be used for collecting and aggregating electrical signals and transmitting the electrical signals to the neuromodulator. A control module may be used which is in communication with the aggregator module for controlling generation of the electrical signals and transmitting the electrical signals to the aggregator.

Pannu, Satinderpall S.↗

Fabrication and electrical properties of single wall carbon nanotube channel and graphene electrode based transistors arrays

A transistor structure composed of an individual single-walled carbon nanotube (SWNT) channel with a graphene electrode was demonstrated. The integrated arrays of transistor devices were prepared by transferring patterned graphene electrode patterns on top of the aligned SWNT along one direction. Both single and multi layer graphene were used for the electrode materials; typical p-type transistor and Schottky diode behavior were observed, respectively. Based on our fabrication method and device performances, several issues are suggested and discussed to improve the device reliability and finally to realize all carbon based future electronic systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-supported Zn/Si core-shell arrays as advanced electrodes for lithium ion batteries

Graphical abstract: Zn/Si core-shell arrays prepared by combined hydrothermal plus sputtering method show good performance with high specific capacity and excellent cycling stability. - Highlights: • Construct Zn/Si core-shell arrays via sputtering. • The Zn/Si core-shell arrays show high capacity and good cycles. • Core-shell arrays is favorable for fast ion/electron transfer. - Abstract: Silicon is considered as the most promising substitute for the commercial graphite anode of lithium ion batteries (LIBs) due to its high capacity and low working voltage. In this work, we realize the rational combination between Zn nanorods and Si forming self-supported Zn/Si core-shell arrays with the aid of hydrothermal and sputtering methods. Amorphous Si layer is well coated on the backbone of Zn nanorods with diameters of 70–80 nm. As a preliminary test, the Zn/Si core-shell arrays are used as the anode of LIBs and demonstrated with a high initial reversible capacity of 2795 mAh g{sup −1} at 0.1C, good high-rate capability with 1985 mAh g{sup −1} at 1C and stable cycling life. The good performance is due to the highly conductive Zn nanorod network and porous core-shell structure providing good mechanical support and fast transport of ions/electrons.

36 MATERIALS SCIENCE↗

Method and device for ion mobility separation

Methods and devices for ion separations or manipulations in gas phase are disclosed. The device includes a non-planar surface having a first, second and third region. An inner arrays of electrodes is positioned on the first region. A first set of electrodes of the inner array of electrodes is configured to receive RF voltages and generate a first potential upon the receipt of the RF voltage. A first and second outer arrays of electrodes are coupled to the second and third region, respectively. The first and second outer arrays are configured to receive a first DC voltage and generate a second potential upon the receipt of the first DC voltages. The first and second generated potential manipulate movement of ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fabrication of Nickel Oxide Nanopillar Arrays on Flexible Electrodes for Highly Efficient Perovskite Solar Cells

Semiconductor nanomaterials with controlled morphologies and architectures are of critical importance for high-performance optoelectronic devices. However, the fabrication of such nanomaterials on polymer-based flexible electrodes is particularly challenging due to degradation of the flexible electrodes at a high temperature. In this paper, we report the fabrication of nickel oxide nanopillar arrays (NiO x NaPAs) on a flexible electrode by vapor deposition, which enables highly efficient perovskite solar cells (PSCs). The NiO x NaPAs exhibit an enhanced light transmittance for light harvesting, prohibit exciton recombination, promote irradiation-generated hole transport and collection, and facilitate the formation of large perovskite grains. These advantageous features result in a high efficiency of 20% and 17% for the rigid and flexible PSCs, respectively. Additionally, the NaPAs show no cracking after 500 times of bending, consistent with the mechanic simulation results. Lastly, this robust fabrication opens a new opportunity for the fabrication of a large area of high-performance flexible optoelectronic devices.

14 SOLAR ENERGY↗