Search NASASearch

SEARCH · Search NASA

Results for “electrode microstructure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

98 records · Page 6

Inhomogeneous Magnetic Anisotropy in an Fe 5– x GeTe 2 Nanoflake Observed by Imaging

Few-layer flakes of ferromagnetic Fe 5–x GeTe 2 with x = 0.3 (F5GT) possess a c-axis magnetocrystalline anisotropy that is large enough below ∼200 K to outcompete the easy-plane shape anisotropy, yielding distinctive magnetic microstructures with out-of-plane (OOP) magnetizations. Using photoemission electron microscopy (PEEM) with magnetic contrast from X-ray magnetic circular dichroism (XMCD) to study a thermally demagnetized h-BN-protected nanoflake of F5GT at 110 K, we observe a micron-scale coexistence between domains with OOP magnetizations (∼70% areal fraction) and hitherto unknown domains in which in-plane (IP) magnetization components dominate (∼30% areal fraction). The regions with dominant IP magnetization components do not correlate with small variations of flake thickness (6–10 nm) and instead arise from local changes of magnetocrystalline anisotropy due to a hitherto unidentified chemical inhomogeneity that we suggest to be a higher concentration of Fe vacancies. Our observation of micron-scale inhomogeneity would likely be missed if imaging a single flake orientation and should affect the viability and performance of van der Waals (vdW) spintronic devices with F5GT electrodes.

2D materials

Developing Stable Critical Materials and Microstructure for High-Flux and Efficient Hydrogen Production through Reversible Solid Oxide Cells

Reversible Solid Oxide Cells (RSOCs), which operate as either Solid Oxide Fuel Cells (SOFCs) or Solid Oxide Electrolytic Cells (SOECs), hold great promise for clean, high-efficiency energy conversion and hydrogen production. However, their commercial potential is hindered by stability issues arising from temperature-induced materials degradation. While substantial progress has been made in developing durable, reduced-temperature SOFCs - bringing them closer to commercial deployment, SOECs still exhibit substantially higher degradation rates at both the cell and stack levels under practical operating conditions.

08 HYDROGEN

ED-cPSD: Fast Phase-Size Distribution via Sequential Erosion-Dilation

The Erosion-Dilation continuous Phase-Size Distribution, ED-cPSD, is an application for calculating continuous pore and particle-size distribution from digital reconstructions and/or image-based structural data. It is based on the erosion-dilation continuous phase-size distribution method. A continuous size distribution is a measure of the probability density of finding a particle or pore of a certain size. These distributions are of interest in any field of study involving porous media, including but not limited to electrochemistry, petroleum engineering, geology, and food science. The algorithm behind the software provides a computationally efficient way to calculate phase-size distributions for large domains. For a 3D battery electrode reconstruction with 1.3 x 10 8 voxels, the particle size distribution is derived in under 2 min on a desktop, while also retaining flexibility and computational efficiency for HPC-scale multi-threading. The software can handle structures with over 10 9 voxels. The algorithm is roughly 280 times faster than a previous version on the same task.

Characterization

Some Aspects of the Failure Mechanisms in BaTiO3-Based Multilayer Ceramic Capacitors

The objective of this presentation is to gain insight into possible failure mechanisms in BaTiO3-based ceramic capacitors that may be associated with the reliability degradation that accompanies a reduction in dielectric thickness, as reported by Intel Corporation in 2010. The volumetric efficiency (microF/cm3) of a multilayer ceramic capacitor (MLCC) has been shown to not increase limitlessly due to the grain size effect on the dielectric constant of ferroelectric ceramic BaTiO3 material. The reliability of an MLCC has been discussed with respect to its structure. The MLCCs with higher numbers of dielectric layers will pose more challenges for the reliability of dielectric material, which is the case for most base-metal-electrode (BME) capacitors. A number of MLCCs manufactured using both precious-metal-electrode (PME) and BME technology, with 25 V rating and various chip sizes and capacitances, were tested at accelerated stress levels. Most of these MLCCs had a failure behavior with two mixed failure modes: the well-known rapid dielectric wearout, and so-called 'early failures." The two failure modes can be distinguished when the testing data were presented and normalized at use-level using a 2-parameter Weibull plot. The early failures had a slope parameter of Beta >1, indicating that the early failures are not infant mortalities. Early failures are triggered due to external electrical overstress and become dominant as dielectric layer thickness decreases, accompanied by a dramatic reduction in reliability. This indicates that early failures are the main cause of the reliability degradation in MLCCs as dielectric layer thickness decreases. All of the early failures are characterized by an avalanche-like breakdown leakage current. The failures have been attributed to the extrinsic minor construction defects introduced during fabrication of the capacitors. A reliability model including dielectric thickness and extrinsic defect feature size is proposed in this presentation. The model can be used to explain the Intel-reported reliability degradation in MLCCs with respect to the reduction of dielectric thickness. It can also be used to estimate the reliability of a MLCC based on its construction and microstructure parameters such as dielectric thickness, average grain size, and number of dielectric layers. Measures for preventing early failures are also discussed in this document.

Liu, David Donhang

Robust dynamic operation of high temperature electrolysis solid oxide cells

Here, this study evaluates the durability of Ni/YSZ-supported SOECs under dynamic operating conditions relevant to real-world applications. Systematic tests were conducted to assess cell performance under steam cycling (3 to 75% humidified H 2 ), mode cycling between SOFC and SOEC operation, thermal cycling (150 to 750 °C at OCV, and 600 to 800 °C at 1.3V), and redox cycling (between 50% humidified H 2 and 50% humidified N 2 ). Steam cycling, mode cycling, and thermal cycling at OCV do not significantly accelerate performance degradation. Thermal cycling at 1.3V caused minimal damage within 600 to 800 °C. Full redox cycling (multi-hour oxidation holds) induced cell structural failure, while partial redox cycling (0.5 h holds) was tolerated. Extensive characterization revealed some material evolution, namely Sr and Co secondary phase formation, within the oxygen electrode due to La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ instability, especially for steam cycling and mode cycling. Minimal changes were identified within the Ni-YSZ fuel electrodes. These findings provide critical insights into SOEC reliability under dynamic conditions, supporting their application in dynamic or intermittent energy systems.

08 HYDROGEN

Development of a scalable, robust electrocatalytic technology for conversion of CO 2 to formic acid via microstructured materials

This project was funded by the Bioenergy Engineering for Product Synthesis (BEEPS) program under the Funding Opportunity Announcement (FOA) DE-FOA-0001916 Topic Area 5 “Rewiring Carbon Utilization”. This FOA sought projects that would electrocatalytically reduce CO 2 to a carbon intermediate and then upconvert to a multi-carbon product or fuel via non-photosynthetic biological system engineering. The project sought to combine the expertise of OCO Chem, whose chief scientist had previously developed an efficient electrocatalytic reactor for conversion of CO 2 to formate with potential to scale, Montana State University investigators who had recently patented a method for laterally grading membranes with the potential of improving reactant distribution and more uniform efficiency across membrane-based reactors, and University of South Florida which had recently discovered a novel C-C bond forming reaction not known to naturally occur in biological systems and which uses C1 substrates and circumvents the central microbial metabolism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Kinetics and Thermodynamics of Sr Permeation in CeO 2 -Based Barrier Layers for Solid-Oxide Electrolyzer Cells

Solid-oxide electrolyzer cells (SOECs) convert steam to hydrogen efficiently at high temperatures. However, during operation, the diffusion of cations or impurities through the cells due to electrode degradation can cause unwanted secondary phases to form, which may degrade device performance. Here, in this study, we use atomistic and mesoscale simulations coupled with experimental analysis to study the diffusion of Sr through the Gd-doped CeO 2 (GDC) barrier layer used to protect the yttria-stabilized zirconia (YSZ) electrolyte in SOECs. From our atomistic calculations, we find Sr diffusion to be negligibly slow in bulk GDC; however, surface diffusion is much more favorable. Subsequent mesoscale simulations show that Sr diffusion is activated when the porosity of GDC exceeds ∼10% and significantly exceeds diffusion in bulk and grain boundary regions. We also find that SrO-based species can accumulate at GDC surfaces; however, SrO aggregation and coarsening will be limited by the large lattice mismatch between GDC and SrO. Energy-dispersive X-ray spectroscopy (EDS) and electron diffraction confirm that Sr can accumulate within GDC pores and form disperse Sr-containing secondary phases. Altogether, Sr diffusion in dense GDC is unlikely to give rise to thick SrO layers, which would severely limit device performance. The formation of Sr-containing secondary phases can largely be avoided by restricting the porosity of the GDC layer as much as possible.

36 MATERIALS SCIENCE

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill