At least 109 records · Page 6

EASY-SHIFT v Alpha

The software is a generic, price- and load-responsive control algorithm integrating heat pumps with thermal energy storage. The algorithm leverages simple models of the system and easily accessible data to schedule operation of heat pumps and thermal energy storage in ways that minimize the cost of operating the heating/cooling system. This tool is specifically designed to be easy to interact with, and something that industry partners are able to adopt. There are two current state of the art approaches. Industry tends to develop very simple algorithms, with predetermined schedules that are not capable of changing operation in response to changes in operating environment. For example, a control designed to avoid high-price electricity from 5-8 PM will not be able to adapt if the high-price period changes to 4-9 PM. Academia commonly develops algorithms called Model predictive control (MPC). MPC requires extensive data and highly trained staff to develop a specific type of simulation model of the building, connect the building to optimization algorithms, and leverage powerful computers. Industry, with limited time/finance budgets for any project, is resistant to adopting MPC due to the associated high complexity and cost.

Grant, Peter [Lawrence Berkeley National Laborator↗

Machine-Learning Assisted Identification of Accurate Battery Lifetime Models with Uncertainty

Reduced-order battery lifetime models, which consist of algebraic expressions for various aging modes, are widely utilized for extrapolating degradation trends from accelerated aging tests to real-world aging scenarios. Identifying models with high accuracy and low uncertainty is crucial for ensuring that model extrapolations are believable, however, it is difficult to compose expressions that accurately predict multivariate data trends; a review of cycling degradation models from literature reveals a wide variety of functional relationships. Here, a machine-learning assisted model identification method is utilized to fit degradation in a stand-out LFP-Gr aging data set, with uncertainty quantified by bootstrap resampling. The model identified in this work results in approximately half the mean absolute error of a human expert model. Models are validated by converting to a state-equation form and comparing predictions against cells aging under varying loads. Parameter uncertainty is carried forward into an energy storage system simulation to estimate the impact of aging model uncertainty on system lifetime. The new model identification method used here reduces life-prediction uncertainty by more than a factor of three (86% ± 5% relative capacity at 10 years for human-expert model, 88.5% ± 1.5% for machine-learning assisted model), empowering more confident estimates of energy storage system lifetime.

25 ENERGY STORAGE↗

Analysis of controls for integrated energy storage system in energy arbitrage configuration with concrete thermal energy storage

Novel highly detailed NuScale reactor and turbo-generator models have been built in Modelica to analyze potential controls for an integrated energy system (IES) configuration combining a nuclear reactor and concrete thermal energy storage (CTES) operating in energy arbitrage. A shakedown test demonstrates the viability of the control schemes to operate across expected operating conditions while maintaining safety limits and buffers. A five-day data set from Idaho is used to show a load-following application of this system that increases the average reactor power level by 20% over the data set and matching demand at nearly all points. Here, by integrating these models, feedback mechanisms across the primary and secondary sides of the nuclear reactor are integrated, and realistic control evaluation is done. All models are consistent with the Hybrid repository, a suite of Modelica models, maintained at Idaho National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling distributed energy resource aggregations in security constrained unit commitment and economic dispatch

The Federal Energy Regulatory Commission (FERC) recently issued Order 2222, which requires all wholesale electricity markets in the US to allow distributed energy resources (DERs) to participate in the market as aggregated resources. These DER aggregations may be composed of many individual resources that are offered and dispatched by the market as a single entity. We present here a model of a distributed energy resource aggregator (DERA) that is scheduled by a market operator’s security constrained unit commitment (SCUC) and security constrained economic dispatch (SCED). The DERA model includes constraints for battery energy storage systems (BESSs), demand response resources (DRRs), and a simple distributed energy resource (DER). This paper describes a model for each resource type and presents two methods for the DERA to generate market offer curves: a profit-maximizing optimization to compute cost curves and a direct cost algorithm to determine dispatch costs for each resource and combine into cost curves. Once all participating DERAs are scheduled in SCUC/SCED, the model is then modified to dispatch individual DERs to maximize profit or minimize schedule deviation of the DERAs. A simulation of a representative day illustrates the DERA offers, the scheduled generation, and the DERA dispatch. Findings show the potential for unavoidable schedule deviations due to internal DER constraints and due to economic incentives to deviate from the SCUC/SCED schedules. This highlights the importance of DERA offer construction on market efficiency and system reliability. Novel aspects of our approach include: (1) We consider the asymmetry of price incentives impacting DERAs from the wholesale market compared to those impacting consumers from the retail market, as imposed by current regulations and laws. (2) We model aggregate consumer response through statistically parameterizable utility functions rather than a potentially impractical approach of modeling each individual consumer. (3) We show how to use the DERA operational dispatch model to create offers into the wholesale electricity market. (4) We show how DERAs may fail to meet their scheduled dispatch because the market offer format may not permit them to fully express their operational features such as intertemporal costs and constraints to the market.

aggregations↗

Where and When Does Solar Plus Storage Make Sense for Commercial Buildings?

As the capital cost of battery energy storage systems (BESS) declines, opportunities for commercial buildings to achieve net savings through peak demand management and energy arbitrage are emerging. National Renewable Energy Laboratory researchers modeled energy storage project economics - with and without accompanying solar photovoltaic systems - using local utility rates, ASHRAE climate zones, and solar intensity data to identify regions where these systems deliver life cycle savings now and in future cost scenarios.

battery energy storage systems↗

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM's existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

batteries↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Rapid Detection of Anomalies in Battery Energy Storage System Data

Data analytics is pivotal in assessing the technical characteristics and performance of Battery Energy Storage Systems (BESS), underpinning BESS modeling, optimization, and control. However, raw datasets frequently harbor anomalies from measurement errors and equipment malfunctions, impacting BESS reliability and analysis accuracy To address the challenge, this paper presents a novel methodology for the rapid detection of anomalous charge or discharge cycles within BESS operational data, expediting the cleaning process while ensuring data integrity. We’ve collected diverse and comprehensive real-world BESS operational datasets in collaboration with the Electric Power Research Institute and multiple Washington State utilities. These datasets serve dual roles: enabling comprehensive data exploration and analysis for understanding underlying challenges and method development, while also acting as a vital validation resource, demonstrating practical effectiveness. The proposed method detects anomalies and aids in their resolution, improving system performance characterization precision. It also reveals recurring data anomaly sources, offering insights for data collection and handling enhancement. Practitioners can gain valuable insights from the identified anomalous cycles in the real-world datasets along with the investigative process for root cause analyses and essential data cleaning steps.

Crawford, Aladsair J.↗

Subscale Hardware-In-The-Loop Results for Hybrid Electric Turbofan Controls Use Cases

NASA is investigating hybrid electric turbine engine systems for commercial transport aircraft due to the potentially significant improvements hybrid electric technology offers in performance, fuel consumption, and operational and design flexibility. Recently, the technology has been tested at full scale in partnership with industry and advanced to Technology Readiness Level 4. This presentation will focus on a recent subscale hardware-in-the-loop test of an open source turbofan engine model developed by NASA. The Advanced Geared Turbofan 30,000 lbf – electrified (AGTF30-e) engine is used as a reference model to demonstrate control system design and use cases for an example mild hybrid electric system with no large-scale energy storage. This model is run in real-time in NASA’s Hybrid Propulsion Emulation Rig (HyPER) and is used to drive an emulation of the turbomachinery system using subscale electric machines. This dynamic scaled shaft emulation interacts with a subscale (<100 kW) hybrid system consisting of electric machines, motor controllers, and a programmable electronic load. Specific use cases demonstrated include the use of Turbine Electrified Energy Management to improve operation during transients, megawatt-scale power extraction from the AGTF30-e, and power transfer between engine spools. Results related to the effectiveness of hybrid systems are qualitatively compared to results from industry testing.

Hybrid↗

PyBLM (Python-based Battery Life Model) [SWR-21-50]

PyBLM is a battery life model to predict the capacity fade of two home battery energy storage systems, manufactured by LG and Tesla. The battery life model is built from experimental test data, and accounts for calendar and cycling aging mechanisms as functions of cell environmental conditions and use. PyBLM is developed in Python and formatted to work in conjunction with another NREL software named TEMPEST (Thermo-Electric Model for Powering Energy Storage Technologies).

Mishra, Partha↗

Investigation of two concrete thermal energy storage system configurations for continuous power production

Two Modelica concrete thermal energy storage (CTES) models are built to analyze potential CTES system designs. One design is the single pipe network design wherein a heat transfer fluid (HTF) flows in one direction during heat deposition and the opposite direction during heat removal. All pipes in the network are used for either deposition (charging) or removal (discharging). The second design is a dual pipe network design in which a network of HTF pipes carries charging fluid and a separate piping network carries discharging HTF. Operation of these two configurations to produce constant steam is evaluated. Here, results indicate that the designs are likely appropriate for different applications with the single pipe network appearing appropriate for batch energy applications and the dual pipe network for continuous energy applications.

25 ENERGY STORAGE↗

Optimal Sizing of an Electric Vehicle Charging Station with Integration of PV and Energy Storage

This paper proposes an optimization model for the optimal configuration of an grid-connected electric vehicle (EV) extreme fast charging station considering integration of photovoltaic (PV) and energy storage. The proposed model minimizes the annualized net cost (i.e., maximizes the annualized net profit) of the extreme fast charging station, including investment and maintenance cost of charging ports, PV and energy storage, net cost of purchasing energy from utility and selling energy to EV customers, degradation cost of energy storage and demand charge. The decision variables are number of charging ports, capacity of invested PV and the power and energy ratings of invested energy storage. The Erlang-loss system is adopted to model the EV mobility. Results of numerical simulations indicate that investment of PV and energy storage could increase the annualized profit of the extreme fast charging station. In addition, the impacts of various parameters on the optimal solution are investigated by sensitivity analysis.

Liu, Guodong↗

Optimal design and integration of decentralized electrochemical energy storage with renewables and fossil plants

Increasing renewable energy requires improving the electricity grid flexibility. Existing measures include power plant cycling and grid-level energy storage, but they incur high operational and investment costs. Using a systems modeling and optimization framework, we study the integration of electrochemical energy storage with individual power plants at various renewable penetration levels. Furthermore, our techno-economic analysis includes both Li-ion and NaS batteries to encompass different technology maturity levels. A California case-study indicates localized integration to be cost-effective for greater grid flexibility. Li-ion batteries can mitigate the residual demand fluctuations of small to medium-sized plants, while NaS batteries would be best-suited for larger storage with higher renewable penetration. Overall, the battery-enabled renewable integration could reduce the unmet grid demand by 75%, the renewable curtailment by 58%, and the CO 2 emission intensity by 16% while including the life cycle emissions of the battery and the renewable farm. Our scenario-based analysis also indicates that rather than replacing all fossil power plants, it is more economical to combine batteries and renewables with individual fossil plants to achieve a clean energy grid.

25 ENERGY STORAGE↗