Search NASA⌕ Search

SEARCH · Search NASA

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Composition Measurements of the HFG1 Glasses

This report provides results from the analyses of glass compositions for the High Fluoride Glasses-1, a series of simulated nuclear waste glasses fabricated at the Pacific Northwest National Laboratory. The series included the quenched version of the glasses. These data will be used to validate or identify areas of potential characterization improvements in the current glass property/composition models. Chemical analyses were performed on a representative sample of each of the quenched glasses to allow for comparisons with the targeted compositions. The relative differences between the targeted and measured concentrations of F, K 2 0, and Li 2 O for some of the glasses were greater than 10%. Overall, there were no indications of errors in batching of the simulated waste glasses. These results can be used in further characterization of this series of glasses, including the normalization of Product Consistency Test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modified Isotherm Modeling to Predict Cs Exchange with Crystalline Silicotitanate in Tank Waste Simulants

The U.S. Department of Energy is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant. To support this goal, Washington River Protection Solutions is designing a Tank Side Cesium Removal (TSCR) system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The ion exchange media selected for Cs removal at TSCR is crystalline silicotitanate (CST) that is manufactured in a nearly spherical form by Honeywell UOP LLC (UOP; Des Plaines, IL) as product IONSIV® R9140-B (Na form). The Zheng Anthony Miller (ZAM) isotherm model (Zheng et al. 1997) is a multicomponent ion exchange model used to predict the exchange of Group I metals onto CST. The ZAM isotherm has historically been used to predict Cs distribution values from Hanford and Savannah River Site (SRS) tank waste simulants. Figure S.1 summarizes model predictions from the ZAM isotherm that indicate poor prediction of Cs distribution values for simple and complex simulants with the engineered form of CST, IONSIV® R9140-B, and IONSIV® R9120-B where the solid line indicates a perfect fit by the model. The dotted lines indicate ±20% error. Batch contact testing with Hanford tank waste complex and simple simulants was used in conjunction with SRS simulants to experimentally determine Cs distribution values using a modification to the original isotherm model. The experimentally determined maximum Cs capacity for IONSIV® R9140-B CST in both the simple and complex matrices was found to be 0.53±0.3 mmoles Cs/g of CST. This value is not drastically different from the maximum Cs capacity of 0.58 mmoles Cs/g TAM-5 reported by Zheng et al. (1997). However, it is important to note that TAM-5 (commercially IONSIV® IE-910) is a powder. Hamm et al. (2002) determined that a dilution factor was needed to account for the Zr(OH)2 binder in the engineered form of CST. Hamm et al. determined that a dilution factor of 0.68 was appropriate to account for binder contribution and correct overprediction of Cs exchange on the engineered form of CST in ZAM calculations. This reduced the total capacity from 0.58 mmol/g with TAM-5 to 0.39 mmol/g for the engineered form of CST (Hamm et al. 2002). Despite substituting the experimentally determined maximum Cs capacity of 0.55 mmoles Cs/g for the literature-reported capacity of 0.39 mmoles Cs/g, it was determined that additional modifications to the model’s equilibrium rate constants were necessary in refining the isotherm model. The modified model overpredicted K+ uptake by the CST when compared to digested CST results described by Campbell et al. (2019). The modified model was further revised to omit three of the five K+ exchange equilibrium reactions described by ZAM to reduce the additional K+ loading seen by the model. Figure S.2 summarizes the revised model isotherm predictions plotted against measured Kd values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

What is the limiting performance of PDV (really)?

The limiting performance of PDV is determined by power spectrum location resolution - The uncertainty principle overestimates error and peak fit confidences underestimates error. Simulations indicate that PDV is: (1) Inaccurate and imprecise at low frequencies; (2) Accurate and (potentially) precise otherwise; (3) Limiting performance can be tied to sampling rate, noise fraction, and analysis duration. Frequency conversion is a good thing. PDV is competitive with VISAR, despite wavelength difference.

99 GENERAL AND MISCELLANEOUS↗

A High-resolution Regional Wave Resource Characterization For The U.S. West Coast

Objectives/Scope: Wave resource characterization is a critical step for wave energy converter deployment in the coastal ocean and relies on long-term, high-resolution wave datasets. This study presents a detailed modeling study of the wave resource along the U.S. West Coast (Washington, Oregon, and California), a coastal region that was identified with high wave energy potential in earlier studies. Methods, Procedures, Process: The wave hindcast covers a 32-year period from 1979 to 2010 and is based on a multi-resolution, unstructured-grid SWAN model framework. Model configuration closely follows and meets the requirements recommended by the International Electrotechnical Commission Technical Specification (IEC TS) for wave energy resource assessment and characterization (Class 2 - feasibility study). The model domain covers the entire U.S. Exclusive Economic Zone (EEZ) in the West Coast and has a spatial resolution varying from ~300 m in the nearshore region (20 km from the shoreline) to ~2500 m within the EEZ and ~5000 m at the open boundary, which extends beyond the EEZ. The model was forced by hourly 2-D wave spectra produced by a two-way nested WaveWatch III model, which covers the global ocean domain and the broader U.S. West Coast region domain with spatial resolutions of 0.5 degree and 10 arc-minutes, respectively. Both wave models are forced by hourly, 0.5-degree wind forcing obtained from NCEP’s Climate Forecast System Reanalysis (CFSR) product. Results, Observations, Conclusions: The standard model output for the SWAN model includes 3-hourly output for the six IEC wave resource parameters (e.g., omnidirectional wave power) at each grid point and hourly 2-D spectra at more than 50 NDBC buoys. Extensive model validation was achieved by comparing the six model-predicted IEC parameters with those derived from field observations at representative NDBC buoys. The error statistics indicated the model’s satisfactory performance. Further analyses were conducted to systematically evaluate the temporal and spatial distributions of wave energy potential and wave climate along the U.S. West Coast. Results suggest that Washington and Oregon coasts have similar nearshore wave resource, which is significantly higher than resources in Southern California. Strong seasonal variations are also observed, e.g., high wave energy tends to occur in the winter months. In summary, this study produced the first high-resolution, comprehensive dataset on wave energy distribution along the U.S. West Coast. Novel/Additive Information: The results are being used by the National Renewable Energy Laboratory to update the MHK Atlas, which was originally derived from NOAA’s 4-arc-minute WaveWatch III model output. In addition, the monthly averaged wave energy climatology dataset can be readily shared to support a variety of research and application efforts within the EEZ of the U.S. West Coast.

Wang, Taiping↗

Poster — Thur Eve — 08: Rotational errors with on-board cone beam computed tomography

The focus of this study is on the Elekta XVI on-board cone beam computed tomography (CBCT) system. A rotational mismatch as large as 0.5° is observed between clockwise (CW) and counter-clockwise (CCW) CBCT scans. The error could affect non-isocentric treatments (e.g., lung SBRT and acoustic neuroma), as well as off-axis organs-at-risk. The error is caused by mislabeling of the projections with a lagging gantry angle, which is caused by the finite image acquisition time and delays in the imaging system. A 30 cm diameter cylindrical phantom with 5 mm diameter holes is used for the scanning. CW and CCW scans are acquired for five gantry speeds (360 to 120 deg./min.) on six linacs from three generations (MLCi, MLCi2, and Agility). Additional scans are acquired with different x-ray pulse widths for the same mAs. In the automated CBCT analysis (using ImageJ), the CW/CCW mismatch in a series of line profiles is identified and used to calculate the rotational error. Results are consistent among all linacs and indicate that the error varies linearly with gantry speed. The finite width of the x-ray pulses is a major but predictable contributor to the delay causing the error. For 40 ms pulses, the delay is 34 ± 1 ms. A simple solution applied in our clinic is adjusting the gantry angle offset to make the CCW one-minute scans correct. A more involved approach we are currently investigating includes adjustments of pulse width and mA, resulting in focal spot changes, with potential impact on image quality.

60 APPLIED LIFE SCIENCES↗

TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project was supported by National Institutes of Health grants R01 EB017095 and U01 EB017185 from the National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

High Order Implicit Residual-Based Spatial Discretization Error Estimation for S N Neutron Transport

This work demonstrates our novel residual source spatial discretization error estimator (LeR/TEAD) for a DGFEM-1 discretization and assesses it along with two contemporary estimators, Ragusa and Wang's h -refinement estimator (RW) and Duo, Azmy, and Zikatanov's explicit residual-based estimator (DAZ), on a suite of Method of Manufactured Solutions (MMS) 2D problems and three realistic problem geometries. LeR/TE-AD is attractive because it directly estimates the local error in the angular flux, as opposed to a mere indicator of the error's behavior, on the same mesh and method order as the original numerical solution, thus typically being less computationally intensive than a refinement-based method. On the MMS suite, LeR/TE-AD consistently displayed a reduced performance versus its DGFEM-0 results in terms of accuracy and precision metrics, though it was not typically grossly inaccurate. This is attributed to the irregularities in the true solution across singular characteristics limiting the local accuracy of the numerical flux solution, leading to poor derivative approximations used in the residual approximations. The error transport problem then spreads the error in the residual to nearby cells, causing a greater degree of imprecision that did not afflict DAZ or RW. In testing the estimators on realistic problem geometries, however, LeR/TE-AD fared better. In practice, the true error is much larger in non-idealized geometries like in MMS, and a superlinear true solution means that RW and DAZ are not beneficially biased for DGFEM-1 error estimation. LeR/TE-AD was typically first or second in accuracy, primarily competing with RW, but the latter usually consumed 2-4 times the computational time as LeR/TE-AD, and requires a solution with four times as many unknowns. Furthermore, RW and LeR/TE-AD can be used to compute direct estimates of the error in any quantity of interest that is based on the angular ux solution, such as the fission rate density in a fuel pin, whereas DAZ requires a heuristic extension due to its norm-based nature.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-330: To Analyze the Calculation Error of Live Dose-Volume Indices Applying 4D-CT in Radiotherapy for PTVs Within the Liver Completely

Purpose: To study the variation rule of normal liver dose-volume indices calculation for the liver malignancy patients whose plan target volumes were in the liver completely in all breath phases. Methods: Ten patients who accepted radiotherapy for malignant tumor were selected in our study. All patients underwent 4D-CT simulation and 3D-CT simulation in free breathing(FB). 4D-CT was sorted into 10 series CT images according to breath phase, named CT0, CT10 to CT90, respectively. And GTVs were contoured on different CT series, and the individual target volume(ITV) was obtained by merging 10 GTVs from 4D-CT. The PTVs were obtained from ITV applying margins. The PTVs were not beyond the boundary of liver in all breath phase observed by dynamic 4D-CT. The radiotherapy plans were designed and irradiation dose was calculated on 3D-CT images, and the livers were contoured on different series CT images and mapped to 3D-CT images applying rigid registration. To compare the dose-volume difference of livers based on distinct CT images. Results: (1)The liver volumes were similar on 4D-CT and 3D-CT images(CTFB 1485±500cm{sup 3}, CT0 1413±377cm{sup 3}, CT10 1409±396cm{sup 3}, CT20 1419±418cm{sup 3},CT30 1485±500cm{sup 3}, CT40 1438±392cm{sup 3}, CT50 1437±404cm{sup 3}, CT60 1439±409cm{sup 3}, CT70 1408±393cm{sup 3}, CT80 1384±397cm{sup 3}, CT90 1398±397cm{sup 3}; F=0.064,p=1.00) (2) The PTVs volume were 30.17±14.62cm{sup 3};(3) The mean dose and V5 to V10 of liver were similar among 4D-CT different series CT images(p>0.05), and the indices varied less than ±4% refer to liver on CT50. Conclusion: The calculation affection of liver dose-volume indices induced by breath motion were not significant for the PTV within liver completely as estimation before. And more objective prediction indices for radiation induced l.

60 APPLIED LIFE SCIENCES↗

PRESAGE: Protecting Structured Address Generation against Soft Errors

Modern computer scaling trends in pursuit of larger component counts and power efficiency have, unfortunately, lead to less reliable hardware and consequently soft errors escaping into application data ("silent data corruptions"). Techniques to enhance system resilience hinge on the availability of efficient error detectors that have high detection rates, low false positive rates, and lower computational overhead. Unfortunately, efficient detectors to detect faults during address generation (to index large arrays) have not been widely researched. We present a novel lightweight compiler-driven technique called PRESAGE for detecting bit-flips affecting structured address computations. A key insight underlying PRESAGE is that any address computation scheme that flows an already incurred error is better than a scheme that corrupts one particular array access but otherwise (falsely) appears to compute perfectly. Enabling the flow of errors allows one to situate detectors at loop exit points, and helps turn silent corruptions into easily detectable error situations. Our experiments using PolyBench benchmark suite indicate that PRESAGE-based error detectors have a high error-detection rate while incurring low overheads.

Sharma, Vishal C.↗

Observations of greenhouse gases as climate indicators

Humans have significantly altered the energy balance of the Earth’s climate system mainly not only by extracting and burning fossil fuels but also by altering the biosphere and using halocarbons. The 3rd US National Climate Assessment pointed to a need for a system of indicators of climate and global change based on long-term data that could be used to support assessments and this led to the development of the National Climate Indicators System (NCIS). Here we identify a representative set of key atmospheric indicators of changes in atmospheric radiative forcing due to greenhouse gases (GHGs), and we evaluate atmospheric composition measurements, including non-CO<:sub>2 GHGs for use as climate change indicators in support of the US National Climate Assessment. GHG abundances and their changes over time can provide valuable information on the success of climate mitigation policies, as well as insights into possible carbon-climate feedback processes that may ultimately affect the success of those policies. To ensure that reliable information for assessing GHG emission changes can be provided on policy-relevant scales, expanded observational efforts are needed. Furthermore, the ability to detect trends resulting from changing emissions requires a commitment to supporting long-term observations. Long-term measurements of greenhouse gases, aerosols, and clouds and related climate indicators used with a dimming/brightening index could provide a foundation for quantifying forcing and its attribution and reducing error in existing indicators that do not account for complicated cloud processes.

54 ENVIRONMENTAL SCIENCES↗

Localization of Southern Resident Killer Whales Using Two Star Arrays to Support Marine Renewable Energy

Tidal power has been identified as one of the most potential commercial-scale renewable energy sources. Puget Sound, Washington, is a potential site to deploy tidal power generating devices. The risk of injury for killer whales needs to be managed before the deployment of these types of devices can be approved by regulating authorities. A passive acoustic system consisting of two star arrays, each with four hydrophones, was designed and implemented for the detection and localization of Southern Resident killer whales. Deployment of the passive acoustic system was conducted at Sequim Bay, Washington. A total of nine test locations were chosen, within a radius of 250 m around the star arrays, to test our localization approach. For the localization algorithm, a least square solver was applied to obtain a bearing location from each star array. The final source location was determined by the intersection of the bearings given by each of the two star arrays. Bearing and distance errors were obtained to conduct comparison between the calculated and true (from Global Positioning System) locations. The results indicated that bearing errors were within 1.04º for eight of the test locations; one location had bearing errors slightly larger than expected due to the strong background noise at that position. For the distance errors, six of the test locations were within the range of 1.91 to 32.36 m. The other two test locations were near the intersection line between the centers of the two star arrays, which were expected to have large errors from the theoretical sensitivity analysis performed.

Passive acoustic system, localization, star array,↗

Bit error protection in cache memories

A computing device having a cache memory (or “cache”) is described, as is a method for operating the cache. The method for operating the cache includes maintaining, in a history record, a representation of a number of bit errors detected in a portion of the cache. When the history record indicates that no bit errors or a single-bit bit error was detected in the portion of the cache memory, the method includes selecting, based on the history record, an error protection to be used for the portion of the cache memory. When the history record indicates that a multi-bit bit error was detected in the portion of the cache memory, the method includes disabling the portion of the cache memory.

97 MATHEMATICS AND COMPUTING↗

Investigating Resilience of Loops in HPC Programs: A Semantic Approach with LLMs

Soft errors have become one of the major concerns for the error resilience of the HPC applications as those errors may cause HPC applications to generate serious outcomes such as silent data corruptions (SDCs). Protecting the applications from soft errors is an essential while challenging task. Among different approaches, obtaining a profound understanding of the resilience proneness of an application is very important to devise efficient error detection and recovery strategies. Given the scale of the HPC applications both in the code size and execution time, there are often cases that the error propagation analysis on such applications would produce a massive volume of unstructured data, which requires a significant amount of efforts, to process and to obtain indicating actions towards error protection. In this paper, we present a control-flow based visual analysis framework to help the users conduct error propagation analysis and identify the critical sections of a program that may have a higher likelihood of leading to erroneous outcomes when affected by the control flow related errors. We also design and implement the scalable visualization framework - ResilienceVis that efficiently and effectively visualizes the affected program states under errors and the propagation traces for an application in a user-friendly manner, and eventually, we combine the analysis and visualization to exhibit the error-proneness of the different sections of applications.

Jiang, Hailong↗

Quantifying structural errors in cloud condensation nuclei activity from reduced representation of aerosol size distributions

Aerosol effects on clouds and radiation are the dominant contribution to uncertainty in radiative forcing relative to the pre-industrial atmosphere. While previous studies have assessed the impact of parametric uncertainty on modeled forcing, structural errors from the numerical representation of particle distributions have not been well quantified. Here we present a framework for quantifying error in aerosol size distributions and cloud condensation nuclei activity, which we apply to the widely used 4-mode version of the Modal Aerosol Module (MAM4). Box model predictions from the MAM4 are evaluated against the Particle Monte Carlo Model for Simulating Aerosol Interactions and Chemistry (PartMC-MOSAIC), a benchmark model that tracks the evolution of individual particles. We show that size distributions simulated by MAM4 diverge from those simulated by PartMC-MOSAIC after only a few hours of aging by condensation and coagulation in polluted conditions, which leads to large errors in modeled cloud condensation nuclei concentrations. We find that differences between MAM4 and PartMC-MOSAIC are largest under polluted conditions, where the size distribution evolves rapidly though aging by condensation of semi-volatile substances and coagulation among particles. These findings suggest that structural error in modeled aerosol properties contributes to the large inter-model variability in aerosol radiative forcing.

Fierce, Laura M.↗

Real-time tumor tracking: Automatic compensation of target motion using the Siemens 160 MLC

Purpose: Advanced high quality radiation therapy techniques such as IMRT require an accurate delivery of precisely modulated radiation fields to the target volume. Interfractional and intrafractional motion of the patient's anatomy, however, may considerably deteriorate the accuracy of the delivered dose to the planned dose distributions. In order to compensate for these potential errors, a dynamic real-time capable MLC control system was designed. Methods: The newly developed adaptive MLC control system contains specialized algorithms which are capable of continuous optimization and correction of the aperture of the MLC according to the motion of the target volume during the dose delivery. The algorithms calculate the new leaf positions based on target information provided online to the system. The algorithms were implemented in a dynamic target tracking control system designed for a Siemens 160 MLC. To assess the quality of the new target tracking system in terms of dosimetric accuracy, experiments with various types of motion patterns using different phantom setups were performed. The phantoms were equipped with radiochromic films placed between solid water slabs. Dosimetric results of exemplary deliveries to moving targets with and without dynamic MLC tracking applied were compared in terms of the gamma criterion to the reference dose delivered to a static phantom. Results: Our measurements indicated that dose errors for clinically relevant two-dimensional target motion can be compensated by the new control system during the dose delivery of open fields. For a clinical IMRT dose distribution, the gamma success rate was increased from 19% to 77% using the new tracking system. Similar improvements were achieved for the delivery of a complete IMRT treatment fraction to a moving lung phantom. However, dosimetric accuracy was limited by the system's latency of 400 ms and the finite leaf width of 5 mm in the isocenter plane. Conclusions: Different experimental setups representing different target tracking scenarios proved that the tracking concept, the new algorithms and the dynamic control system make it possible to effectively compensate for dose errors due to target motion in real-time. These early results indicate that the method is suited to increasing the accuracy and the quality of the treatment delivery for the irradiation of moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

High Impedance Fault Detection Through Quasi-Static State Estimation: A Parameter Error Modeling Approach

This paper presents a model for detecting high impedance faults using parameter error modeling and a two step per-phase weighted-least squares state estimation process. The proposed scheme leverages the use of Phasor Measurement Units and synthetic measurements to identify per-phase power flow and injection measurements which indicate a parameter error through ?2 Hypothesis Testing applied to the composed measurement error. Although current and voltage waveforms are commonly analyzed for high-impedance fault detection, wide area power flow and injection measurements, which are already inherent to the state estimation process, also show promise for real-world high-impedance fault detection applications. The error distributions after detection share the measurement function error spread observed in proven parameter error diagnostics and can be applied to high-impedance fault identification. Further, this error spread across measurement functions related to the fault will be clearly discerned from measurement error. Case studies are performed on the IEEE 33-Bus Distribution System along with the proposed model in Simulink.

Cooper, Austin↗

An Hp-Adaptive Minimum Action Method Based on a Posteriori Error Estimate

In this work, we develop an hp-adaptive minimum action method (MAM). MAM plays an important role to minimize the Freidlin-Wentzell action functional, which is the central object of the Freidlin-Wentzell theory of large deviations for transitions induced by small random perturbations. Because of the demanding computation cost, especially in spatially extended systems, numerical efficiency is a critical issue for MAM. Difficulties come from discretizations of both time and space. One hurdle for the application of MAM to large scale systems is the global reparametrization in time direction, which is required by most versions of MAM. We recently introduced a new version of MAM in [25], called tMAM, where we used some simple heuristic criteria to demonstrate that tMAM can be effectively coupled with h-adaptivity. The target of this paper is to integrate hp-adaptivity into tMAM using a posterior error estimation techniques. More specifically, we use the arc length constraint given by geometric minimum action method (gMAM) to define an indicator of the effect of linear time scaling in tMAM, and the derivative recovery technique to construct an error indicator and a regularity indicator for hp-refinement. Numerical results are presented.

Wan, Xiaoliang↗

Motoneuron axon pathfinding errors in zebrafish: Differential effects related to concentration and timing of nicotine exposure

Nicotine exposure during embryonic stages of development can affect many neurodevelopmental processes. In the developing zebrafish, exposure to nicotine was reported to cause axonal pathfinding errors in the later born secondary motoneurons (SMNs). These alterations in SMN axon morphology coincided with muscle degeneration at high nicotine concentrations (15–30 μM). Previous work showed that the paralytic mutant zebrafish known as sofa potato exhibited nicotine-induced effects onto SMN axons at these high concentrations but in the absence of any muscle deficits, indicating that pathfinding errors could occur independent of muscle effects. In this study, we used varying concentrations of nicotine at different developmental windows of exposure to specifically isolate its effects onto subpopulations of motoneuron axons. We found that nicotine exposure can affect SMN axon morphology in a dose-dependent manner. At low concentrations of nicotine, SMN axons exhibited pathfinding errors, in the absence of any nicotine-induced muscle abnormalities. Moreover, the nicotine exposure paradigms used affected the 3 subpopulations of SMN axons differently, but the dorsal projecting SMN axons were primarily affected. We then identified morphologically distinct pathfinding errors that best described the nicotine-induced effects on dorsal projecting SMN axons. To test whether SMN pathfinding was potentially influenced by alterations in the early born primary motoneuron (PMN), we performed dual labeling studies, where both PMN and SMN axons were simultaneously labeled with antibodies. We show that only a subset of the SMN axon pathfinding errors coincided with abnormal PMN axonal targeting in nicotine-exposed zebrafish. We conclude that nicotine exposure can exert differential effects depending on the levels of nicotine and developmental exposure window. - Highlights: • Embryonic nicotine exposure can specifically affect secondary motoneuron axons in a dose-dependent manner. • The nicotine-induced secondary motoneuron axonal pathfinding errors can occur independent of any muscle fiber alterations. • Nicotine exposure primarily affects dorsal projecting secondary motoneurons axons. • Nicotine-induced primary motoneuron axon pathfinding errors can influence secondary motoneuron axon morphology.

60 APPLIED LIFE SCIENCES↗