BBMap: A Fast, Accurate, Splice-Aware Aligner

Alignment of reads is one of the primary computational tasks in bioinformatics. Of paramount importance to resequencing, alignment is also crucial to other areas - quality control, scaffolding, string-graph assembly, homology detection, assembly evaluation, error-correction, expression quantification, and even as a tool to evaluate other tools. An optimal aligner would greatly improve virtually any sequencing process, but optimal alignment is prohibitively expensive for gigabases of data. Here, we will present BBMap [1], a fast splice-aware aligner for short and long reads. We will demonstrate that BBMap has superior speed, sensitivity, and specificity to alternative high-throughput aligners bowtie2 [2], bwa [3], smalt, [4] GSNAP [5], and BLASR [6].

09 BIOMASS FUELS↗

The Reduction of Random Uncertainty in Differential Temperature Measurements Using Common Leg Thermocouples

The uncertainty quantification of random error is considered for common leg thermocouples (i.e., where one thermoelement is shared along the length of the TC for all other TC junctions present). The uncertainty is presented for both a common leg and individual, separate leg thermocouples. For Type K thermocouples a reduction in uncertainty by up to 3x is capable when differential temperatures, ?T, are within 150°C, and diminishes to little to no improvement above 150°C.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

SU-G-IeP1-07: Inaccuracy of Lesion Blood Flow Quantification Related to the Proton Density Reference Image in Arterial Spin Labeling MRI of Brain Tumors

Purpose: Cerebral blood flow quantification in arterial spin labeling (ASL) MRI requires an estimate of the equilibrium magnetization of blood, which is often obtained by a set of proton density (PD) reference image. Normally, a constant blood-brain partition coefficient is assumed across the brain. However, this assumption may not be valid for brain lesions. This study aimed to evaluate the impact of lesion-related PD variations on ASL quantification in patients with brain tumors. Methods: MR images for posttreatment evaluation of 42 patients with brain tumors were retrospectively analyzed. These images were acquired on a 3T MRI scanner, including T2-weighted FLAIR, 3D pseudo-continuous ASL and post-contrast T1-weighted images. Anatomical images were coregistered with ASL images using the SPM software. Regions of interest (ROIs) of the enhancing and FLAIR lesions were manually drawn on the coregistered images. ROIs of the contralateral normal appearing tissues were also determined, with the consideration of approximating coil sensitivity patterns in lesion ROIs. Relative lesion blood flow (lesion/contralateral tissue) was calculated from both the CBF map (dependent on the PD) and the ΔM map for comparison. Results: The signal intensities in both enhancing and FLAIR lesions were significantly different than contralateral tissues on the PD reference image (p<0.001). The percent signal difference ranged from −15.9 to 19.2%, with a mean of 5.4% for the enhancing lesion, and from −2.8 to 22.9% with a mean of 10.1% for the FLAIR lesion. The high/low lesion-related PD signal resulted in inversely proportional under-/over-estimation of blood flow in both enhancing and FLAIR lesions. Conclusion: Significant signal differences were found between lesions and contralateral tissues in the PD reference image, which introduced errors in blood flow quantification in ASL. The error can be up to 20% in individual patients with an average of 5- 10% for the group of patients with brain tumors.

60 APPLIED LIFE SCIENCES↗

On-line Generation and Error Handling for Surrogate Models within Multifidelity Uncertainty Quantification

Uncertainty quantification is recognized as a fundamental task to obtain predictive numerical simulations. However, many realistic engineering applications require complex and computationally expensive high-fidelity numerical simulations for the accurate characterization of the system responses. Moreover, complex physical models and extreme operative conditions can easily lead to hundreds of uncertain parameters that need to be propagated through high-fidelity codes. Under these circumstances, a single fidelity approach, i.e. a workflow that only uses high-fidelity simulations to perform the uncertainty quantification task, is unfeasible due to the prohibitive overall computational cost. In recent years, multifidelity strategies have been introduced to overcome this issue. The core idea of this family of methods is to combine simulations with varying levels of fidelity/accuracy in order to obtain the multifidelity estimators or surrogates with the same accuracy of their single fidelity counterparts at a much lower computational cost. This goal is usually accomplished by defining a prioria sequence of discretization levels or physical modeling assumptions that can be used to decrease the complexity of a numerical realization and thus its computational cost. However ,less attention has been dedicated to low-fidelity models that can be built directly from the small number of high-fidelity simulations available. In this work we focus our attention on Reduced-Order Models that can be considered a particular class of data-driven approaches. Our main goal is to explore the combination of multifidelity uncertainty quantification and reduced-order models to obtain an efficient framework for propagating uncertainties through expensive numerical codes.

97 MATHEMATICS AND COMPUTING↗

Simulation of Wingtip Vortex Flows with Reynolds-Averaged Navier–Stokes and Scale-Resolving Simulation Methods

The simulation of wingtip vortex flows is reported on with Reynolds-averaged Navier–Stokes (RANS) equations and scale-resolving simulation (SRS) models. These range from turbulent viscosity and Reynolds-stress model (RSM) RANS closures, to hybrid and bridging SRS methods. The aim of the study was threefold: assess the relevance of replicating the experimental flow conditions, evaluate the numerical requisites of each mathematical model, and determine their modeling accuracy in prediction of a representative wingtip vortex flow. The selected problem is the flow around a NACA 0012 wing at 10 deg of angle of attack and Reynolds number of 4.60×10 6 . The results confirm the relevance of reproducing the experimental flow conditions, in particular at the inlet boundary where the flow is not uniform. For this reason, the evaluation of modeling errors using the available measurements requires the specification of the experimental inlet conditions. On the other hand, the quantification of the modeling error indicates that solely RANS–RSM can achieve an accurate representation of the flow dynamics. Whereas the well-recognized limitations of turbulent viscosity RANS closures to deal with solid-body rotation lead to the overprediction of turbulence and consequent rapid diffusion of the wingtip vortex, the predictive use of SRS methods may reveal excessively complex and demanding.

42 ENGINEERING↗

Mapping DNA polymerase errors by single-molecule sequencing

Genomic integrity is compromised by DNA polymerase replication errors, which occur in a sequence-dependent manner across the genome. Accurate and complete quantification of a DNA polymerase's error spectrum is challenging because errors are rare and difficult to detect. We report a high-throughput sequencing assay to map in vitro DNA replication errors at the single-molecule level. Unlike previous methods, our assay is able to rapidly detect a large number of polymerase errors at base resolution over any template substrate without quantification bias. To overcome the high error rate of high-throughput sequencing, our assay uses a barcoding strategy in which each replication product is tagged with a unique nucleotide sequence before amplification. Here, this allows multiple sequencing reads of the same product to be compared so that sequencing errors can be found and removed. We demonstrate the ability of our assay to characterize the average error rate, error hotspots and lesion bypass fidelity of several DNA polymerases.

60 APPLIED LIFE SCIENCES↗

Carbonyl Identification and Quantification Uncertainties for Oxidative Polymer Degradation

The most revealing indicator for oxidative processes or state of degraded plastics is usually carbonyl formation, a key step in materials degradation as part of the carbon cycle for man-made materials. Hence, the identification and quantification of carbonyl species with infrared spectroscopy have been the method of choice for generations, thanks to their strong absorbance and being an essential intermediate in carbon oxidation pathways. Despite their importance, precise identification and quantification can be challenging and rigorous fully traceable data are surprisingly rare in the existing literature. An overview of the complexity of carbonyl quantification is presented by the screening of reference compounds in solution with transmission and polymer films with ATR IR spectroscopy, and systematic data analyses. Significant variances in existing data and their past use have been recognized. Guidance is offered how better measurements and data reporting could be accomplished. Experimental variances depend on the combination of uncertainty in exact carbonyl species, extinction coefficient, contributions from neighboring convoluting peaks, matrix interaction phenomena and instrumental variations in primary IR spectral acquisition (refractive index and penetration depth for ATR measurements). In addition, diverging sources for relevant extinction coefficients may exist, based on original spectral acquisition. For common polymer degradation challenges, a relative comparison of carbonyl yields for a material is easily accessible, but quantification for other purposes, such as degradation rates and spatially dependent interpretation, requires thorough experimental validation. All variables featured in this overview demonstrate the significant error margins in carbonyl quantification, with exact carbonyl species and extinction coefficients already being major contributors on their own.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical analysis on the measurement errors of local 2D DIC: Part I temporal and spatial uncertainty quantification of displacement measurements

This study presents a theoretical uncertainty quantification of displacement measurements by subset-based 2D-digital image correlation. A generalized solution to estimate the random error of displacement measurement is presented. The obtained solution suggests that the random error of displacement measurements is determined by the image noise, the summation of the intensity gradient in a subset, the subpixel part of displacement, and the interpolation scheme. The proposed method is validated with virtual digital image correlation tests.

2D-DIC↗

Whitepaper prepared for DOE Workshop on Integrated Simulations for Magnetic Fusion Energy Sciences: Topic E: Beyond interpretive simulations

Predictive simulations of magnetic confinement fusion and burning plasmas will require the quantification of all uncertainties and errors relating to the simulation capabilities. These include: discretization error (temporal and spatial); incomplete convergence error (nonlinear, linear, etc.); uncertainties in input data (initial conditions, boundary conditions, coefficients, thermo-physical properties, source terms, etc.); and uncertainties in the component models (the specific form and parameter values).13 Typically, there is a focus on model parameter uncertainties but uncertainties about which model to use and about the bias or discrepancy of a particular model (sometimes called model form error) often dominate parameter uncertainty. This whitepaper addresses the challenges of performing uncertainty quantification (UQ) for expensive computational models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-C-BRE-08: IMRT QA: Selecting Meaningful Gamma Criteria Based On Error Detection Sensitivity

Purpose: To develop a strategy for defining meaningful tolerance limits and studying the sensitivity of IMRT QA gamma criteria by inducing known errors in QA plans. Methods: IMRT QA measurements (ArcCHECK, Sun Nuclear) were compared to QA plan calculations with induced errors. Many (>24) gamma comparisons between data and calculations were performed for each of several kinds of cases and classes of induced error types with varying magnitudes (e.g. MU errors ranging from -10% to +10%), resulting in over 3,000 comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using various gamma criteria. Results: This study demonstrates that random, case-specific, and systematic errors can be detected by the error curve analysis. Depending on location of the peak of the error curve (e.g., not centered about zero), 3%/3mm threshold=10% criteria may miss MU errors of up to 10% and random MLC errors of up to 5 mm. Additionally, using larger dose thresholds for specific devices may increase error sensitivity (for the same X%/Ymm criteria) by up to a factor of two. This analysis will allow clinics to select more meaningful gamma criteria based on QA device, treatment techniques, and acceptable error tolerances. Conclusion: We propose a strategy for selecting gamma parameters based on the sensitivity of gamma criteria and individual QA devices to induced calculation errors in QA plans. Our data suggest large errors may be missed using conventional gamma criteria and that using stricter criteria with an increased dose threshold may reduce the range of missed errors. This approach allows quantification of gamma criteria sensitivity and is straightforward to apply to other combinations of devices and treatment techniques.

60 APPLIED LIFE SCIENCES↗

Spatial DIC Errors due to Pattern-Induced Bias and Grey Level Discretization

Digital image correlation (DIC) is an optical metrology method widely used in experimental mechanics for full-field shape, displacement and strain measurements. The required strain resolution for engineering applications of interest mandates DIC to have a high image displacement matching accuracy, on the order of 1/100th of a pixel, which necessitates an understanding of DIC errors. In this paper, we examine two spatial bias terms that have been almost completely overlooked. They cause a persistent offset in the matching of image intensities and thus corrupt DIC results. We name them pattern-induced bias (PIB), and intensity discretization bias (IDB). We show that the PIB error occurs in the presence of an undermatched shape function and is primarily dictated by the underlying intensity pattern for a fixed displacement field and DIC settings. The IDB error is due to the quantization of the gray level intensity values in the digital camera. In this paper we demonstrate these errors and quantify their magnitudes both experimentally and with synthetic images.

47 OTHER INSTRUMENTATION↗

Assessment of Planning Target Volume Margins for Intensity-Modulated Radiotherapy of the Prostate Gland: Role of Daily Inter- and Intrafraction Motion

Purpose: To determine planning target volume margins for prostate intensity-modulated radiotherapy based on inter- and intrafraction motion using four daily localization techniques: three-point skin mark alignment, volumetric imaging with bony landmark registration, volumetric imaging with implanted fiducial marker registration, and implanted electromagnetic transponders (beacons) detection. Methods and Materials: Fourteen patients who underwent definitive intensity-modulated radiotherapy for prostate cancer formed the basis of this study. Each patient was implanted with three electromagnetic transponders and underwent a course of 39 treatment fractions. Daily localization was based on three-point skin mark alignment followed by transponder detection and patient repositioning. Transponder positioning was verified by volumetric imaging with cone-beam computed tomography of the pelvis. Relative motion between the prostate gland and bony anatomy was quantified by offline analyses of daily cone-beam computed tomography. Intratreatment organ motion was monitored continuously by the Calypso (registered) System for quantification of intrafraction setup error. Results: As expected, setup error (that is, inter- plus intrafraction motion, unless otherwise stated) was largest with skin mark alignment, requiring margins of 7.5 mm, 11.4 mm, and 16.3 mm, in the lateral (LR), longitudinal (SI), and vertical (AP) directions, respectively. Margin requirements accounting for intrafraction motion were smallest for transponder detection localization techniques, requiring margins of 1.4 mm (LR), 2.6 mm (SI), and 2.3 mm (AP). Bony anatomy alignment required 2.1 mm (LR), 9.4 mm (SI), and 10.5 mm (AP), whereas image-guided marker alignment required 2.8 mm (LR), 3.7 mm (SI), and 3.2 mm (AP). No marker migration was observed in the cohort. Conclusion: Clinically feasible, rapid, and reliable tools such as the electromagnetic transponder detection system for pretreatment target localization and, subsequently, intratreatment target location monitoring allow clinicians to reduce irradiated volumes and facilitate safe dose escalation, where appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Intrafraction and Interfraction Tumor Motion Amplitude and Prediction Error for Different Liver Tumor Trajectories in Cyberknife Synchrony Tracking

To research the fiducial-based, real-time tracking intrafraction (during the fraction [intra-]) and interfraction (between fractions [inter-]) tumor respiration amplitude, motion trajectory, and prediction error and quantify their relationships for different types of motion trajectories during Cyberknife-based stereotactic ablation radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stochastic multiscale modeling for quantifying statistical and model errors with application to composite materials

This paper provides a coherent and efficient computational framework for stochastic multiscale analysis of material systems in the presence of parametric uncertainties and modeling errors. Uncertainty in those model parameters that are not deduced as upscaled quantities is attributed to an uncertainty “germ”. While such parameters can appear at any scale, they are predominant at the finest analysis scale. Additional uncertainties stemming from statistical estimation, attributed to lack of data and model error, are associated with each submodel contributing to the multiscale system. Here, a robust and efficient framework based on a generalized extended polynomial chaos expansion (gEPCE) is proposed to simultaneously propagate all these uncertainties in order to provide a probabilistic representation of specific quantities of interest (QoI). We characterize the full probability distribution of the QoI and the uncertainty in the failure probability pertaining to its tails. By combining gEPCE with kernel density estimation (KDE) and directional derivatives, we construct sensitivity measures that connect these statistical metrics of QoI to the various sources of uncertainty to assess their individual and combined impacts. An illustrative problem featuring three-point bending of a composite beam is investigated to demonstrate the presented approach.