Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Modifications to the Bubble experiment and preparation for additional irradiations

SHINE Medical Technologies is planning to use neutron-induced fission in a subcritical low-enriched-uranium uranyl sulfate target solution for production of 99 Mo. During this operation, the solution will undergo self-heating due to fissioning of the uranium, radiolytic decomposition of the water, and circulation due to thermal gradients generated in the solution, and will be cooled by cooling tubes running through the annulus and from cooling outside the annulus. Because the formation of the radiolysis-induced bubbles (H 2 and O 2 ) and their size and dynamics will impact the operational parameters of the liquid target, an understanding of bubble behavior is critical for the ability to predict the behavior of the target solution during this operation. It is also important to be able to predict the thermal gradients and the circulation in the vessel. Researchers at Argonne National Laboratory have designed an experimental setup to study radiolytic gas formation in uranyl sulfate under direct electron beam irradiation and have conducted initial experiments. Results of those experiments provided invaluable information on thermal hydraulic behavior of the solution and some information on bubble formation and behavior, but those initial experiments fell short in the measurements of the gas generation rates and bubble behavior. To address the shortcomings of the original experiment, the irradiation setup was modified to improve our abilities to measure gas generation rates and measure the temperature distribution in the solution with better precision. Modifications to the experimental setup and preparation for the irradiations are described below.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of the weak charge of the carbon-12 nucleus within the P2 experiment in Mainz

The P2 experiment at the MESA facility in Mainz aims to make a high precision measurement of the weak charge of the proton, and a suitable experimental setup is currently being designed [1]. As high precision measurements of the weak charges of different particles and nuclei are differently sensitive to physics beyond the Standard Model in the form of new quantum loop correction parameters, experiments with a range of different target materials are complementary. We introduce first feasibility considerations for the determination of the Weak Mixing Angle via the scattering of electrons from carbon nuclei in a graphite target with the P2 detector setup. In order to make an estimate of the achievable precision we present analytic calculations as well as Monte-Carlo simulations. The results of Geant4 simulations of proposed experimental setups are included.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward quasi-DC conductivity of warm dense matter measured by single-shot terahertz spectroscopy

Here, we present an experimental setup capable of measuring the near DC conductivity of laser generated warm dense matter using single-shot terahertz time-domain spectroscopy. The setup uses a reflective echelon and balanced detection to record THz waveforms with a minimum detectable signal of 0.2% in a single laser pulse. We describe details of the experimental setup and the data analysis procedure and present single-shot terahertz transmission data on aluminum that has been laser heated to an electron temperature of 0.5 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A straightforward method for Vacuum-Ultraviolet flux measurements: The case of the hydrogen discharge lamp and implications for solid-phase actinometry

Vacuum-Ultraviolet (VUV) radiation is responsible for the photo-processing of simple and complex molecules in several terrestrial and extraterrestrial environments. In the laboratory such radiation is commonly simulated by inexpensive and easy-to-use microwave-powered hydrogen discharge lamps. However, VUV flux measurements are not trivial and the methods/devices typically used for this purpose, mainly actinometry and calibrated VUV silicon photodiodes, are not very accurate or expensive and lack of general suitability to experimental setups. Here, we present a straightforward method for measuring the VUV photon flux based on the photoelectric effect and using a gold photodetector. This method is easily applicable to most experimental setups, bypasses the major problems of the other methods, and provides reliable flux measurements. As a case study, the method is applied to a microwave-powered hydrogen discharge lamp. In addition, the comparison of these flux measurements to those obtained by O{sub 2} actinometry experiments allow us to estimate the quantum yield (QY) values QY{sub 122} = 0.44 ± 0.16 and QY{sub 160} = 0.87 ± 0.30 for solid-phase O{sub 2} actinometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous translational temperature measurements of different atomic species in plasma flows using scanning Fabry-Perot interferometry

A revised scientific instrument to measure simultaneously kinetic temperatures of different atoms from their optical emission profile is reported. Emission lines are simultaneously detected using one single scanning Fabry-Perot-interferometer (FPI) for a combined spectroscopic setup to acquire different emission lines simultaneously. The setup consists in a commercial Czerny-Turner spectrometer configuration which is combined with a scanning Fabry-Perot interferometer. The fast image acquisition mode of an intensified charge coupled device camera allows the detection of a wavelength interval of interest continuously while acquiring the highly resolved line during the scan of the FPI ramp. Results using this new setup are presented for the simultaneous detection of atomic nitrogen and oxygen in a high enthalpy air plasma flow as used for atmospheric re-entry research and their respective kinetic temperatures derived from the measured line profiles. The paper presents the experimental setup, the calibration procedure, and an exemplary result. The determined temperatures are different, a finding that has been published so far as due to a drawback of the experimental setup of sequential measurements, and which has now to be investigated in more detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Setup for chemical atmospheric control during in situ grazing incidence X-ray scattering of printed thin films

In order to tailor the assembling of polymers and organic molecules, a deeper understanding of the kinetics involved in thin film production is necessary. While post-production characterization only provides insight on the final film structure, more sophisticated experimental setups are needed to probe the structure formation processes in situ during deposition. The drying kinetics of a deposited organic thin film strongly influences the assembling process on the nanometer scale. Lastly, this work presents an experimental setup that enables fine control of the atmosphere composition surrounding the sample during slot die coating, while simultaneously probing the film formation kinetics using in situ grazing incidence X-ray scattering and spectroscopy.

36 MATERIALS SCIENCE↗

Experimental Studies on Dynamic Vibration Absorber using Shape Memory Alloy (NiTi) Springs

Shape memory alloy (SMA) springs have been used as actuators in many applications although their use in the vibration control area is very recent. Since shape memory alloys differ from conventional alloy materials in many ways, the traditional design approach for springs is not completely suitable for designing SMA springs. Some vibration control concepts utilizing unique characteristics of SMA's will be presented in this paper.A dynamic vibration absorber (DVA) using shape memory alloy (SMA) actuator is developed for attenuation of vibration in a cantilever beam. The design procedure of the DVA is presented. The system consists of a cantilever beam which is considered to generate the real-time vibration using shaker. A SMA spring is used with a mass attached to its end. The stiffness of the SMA spring is dynamically varied in such a way to attenuate the vibration. Both simulation and experimentation are carried out using PID controller. The experiments were carried out by interfacing the experimental setup with a computer using LabVIEW software, Data acquisition and control are implemented using a PCI data acquisition card. Standard PID controllers have been used to control the vibration of the beam. Experimental results are used to demonstrate the effectiveness of the controllers designed and the usefulness of the proposed test platform by exciting the structure at resonance. In experimental setup, an accelerometer is used to measure the vibration which is fed to computer and correspondingly the SMA spring is actuated to change its stiffness to control the vibration. The results obtained illustrate that the developed DVA using SMA actuator is very effective in reducing structural response and have great potential to be an active vibration control medium.

36 MATERIALS SCIENCE↗

Preparations for a high gradient inverse free electron laser experiment at Brookhaven national laboratory

Preparations for an inverse free electron laser experiment at Brookhaven National Laboratory's Accelerator Test Facilty are presented. Details of the experimental setup including beam and laser transport optics are first discussed. Next, the driving laser pulse structure is investigated and initial diagnostics are explored and compared to simulations. Finally, planned improvements to the experimental setup are discussed.

43 PARTICLE ACCELERATORS↗

Simultaneous measurement of specific heat and thermal conductivity in pulsed magnetic fields

Here we report an experimental setup for simultaneously measuring specific heat and thermal conductivity in feedback-controlled pulsed magnetic fields of 50 ms duration at cryogenic temperatures. A stabilized magnetic field pulse obtained by the feedback control, which dramatically improves the thermal stability of the setup and sample, is used in combination with the flash method to obtain absolute values of thermal properties up to 37.2 T in the 22–16 K temperature range. We describe the experimental setup and demonstrate the performance of the present method with measurements on single-crystal samples of the geometrically frustrated quantum spin-dimer system SrCu 2 (BO 3 ) 2 . Our proof-of-principle results show excellent agreement with data taken using a standard steady-state method, confirming the validity and convenience of the present approach.

47 OTHER INSTRUMENTATION↗

Large Field Photogrammetry Techniques in Aircraft and Spacecraft Impact Testing

The Landing and Impact Research Facility (LandIR) at NASA Langley Research Center is a 240 ft. high A-frame structure which is used for full-scale crash testing of aircraft and rotorcraft vehicles. Because the LandIR provides a unique capability to introduce impact velocities in the forward and vertical directions, it is also serving as the facility for landing tests on full-scale and sub-scale Orion spacecraft mass simulators. Recently, a three-dimensional photogrammetry system was acquired to assist with the gathering of vehicle flight data before, throughout and after the impact. This data provides the basis for the post-test analysis and data reduction. Experimental setups for pendulum swing tests on vehicles having both forward and vertical velocities can extend to 50 x 50 x 50 foot cubes, while weather, vehicle geometry, and other constraints make each experimental setup unique to each test. This paper will discuss the specific calibration techniques for large fields of views, camera and lens selection, data processing, as well as best practice techniques learned from using the large field of view photogrammetry on a multitude of crash and landing test scenarios unique to the LandIR.

Littell, Justin D.↗

The Halls B and C semi-inclusive deep inelastic scattering program towards the transverse momentum dependence of valence quarks

Inclusive and semi-inclusive deep inelastic scattering (DIS and SIDIS) are important tools for understanding the structure of nucleons and nuclei. Spin asymmetries in polarized SIDIS are directly related to transverse momentum dependent parton distributions (TMDs) and fragmentation functions. The usual collinear parton distribution functions depend on the fraction of hadron momentum carried by the parton, x, and the space-time resolution scale, Q2. The TMDs, which depend also on the intrinsic transverse momentum of the parton, kT, provide a three-dimensional partonic picture of the nucleon in momentum space. These TMDs have not yet been studied in detail. The 12 GeV era at JLab can move this to a new level of sophistication, thanks to the extraordinary statistical accuracy achievable and the extended kinematic reach provided by the 11 GeV beam. This calls for a multi-pronged approach with multi-dimensional data, for all combinations of beam and target polarization, and different hadrons. Hall B with its large-acceptance CLAS12 spectrometer will likely be the workhorse of SIDIS physics to provide multi-dimensional cross sections, azimuthal distributions and single- and double-spin asymmetries, using both unpolarized and polarized proton and deuteron targets, and unpolarized nuclear targets. The much-anticipated addition of a RICH detector to the CLAS12 base equipment will start an unprecedented SIDIS program with kaons, giving insights to the strange flavor dependence of the TMDs. Hall C with its "pinhole" magnetic spectrometer pair would add precision cross sections and their ratios for both pions and kaons. The rigid connection to the pivot allows for longitudinal-transverse separations, unique amongst the Hall experimental setups. Given the relative simplicity to change the magnet polarities, and the anticipated large reproducibility and systematic understanding of the spectrometer setup, Hall C will be the best place for 1%-level measurements of ?+/?? ratios, or kaon ratios, and due to its precision will allow for longitudinal-transverse separations, unique amongst the Hall experimental setups. Disadvantage of the setup is the lack of full azimuthal coverage at larger pT. The multi-pronged SIDIS approach combining foreseen 12-GeV experiments in large acceptance Hall B and precision Hall C will be presented.

Ent, Rolf↗

Direct speciation analysis of arsenic in sub-cellular compartments using micro-X-ray absorption spectroscopy

Identification of arsenic chemical species at a sub-cellular level is a key to understanding the mechanisms involved in arsenic toxicology and antitumor pharmacology. When performed with a microbeam, X-ray absorption near-edge structure ({mu}-XANES) enables the direct speciation analysis of arsenic in sub-cellular compartments avoiding cell fractionation and other preparation steps that might modify the chemical species. This methodology couples tracking of cellular organelles in a single cell by confocal or epifluorescence microscopy with local analysis of chemical species by {mu}-XANES. Here we report the results obtained with a {mu}-XANES experimental setup based on Kirkpatrick-Baez X-ray focusing optics that maintains high flux of incoming radiation (>10{sup 11} ph/s) at micrometric spatial resolution (1.5x4.0 {mu}m{sup 2}). This original experimental setup enabled the direct speciation analysis of arsenic in sub-cellular organelles with a 10{sup -15} g detection limit. {mu}-XANES shows that inorganic arsenite, As(OH){sub 3}, is the main form of arsenic in the cytosol, nucleus, and mitochondrial network of cultured cancer cells exposed to As{sub 2}O{sub 3}. On the other hand, a predominance of As(III) species is observed in HepG2 cells exposed to As(OH){sub 3} with, in some cases, oxidation to a pentavalent form in nuclear structures of HepG2 cells. The observation of intra-nuclear mixed redox states suggests an inter-individual variability in a cell population that can only be evidenced with direct sub-cellular speciation analysis.

60 APPLIED LIFE SCIENCES↗

Three-dimensional full-field velocity measurements in shock compression experiments using stereo digital image correlation

Shock compression plate impact experiments conventionally rely on point-wise velocimetry measurements based on laser-based interferometric techniques. This study presents an experimental methodology to measure the free surface full-field particle velocity in shock compression experiments using high-speed imaging and three-dimensional (3D) digital image correlation (DIC). The experimental setup has a temporal resolution of 100 ns with a spatial resolution varying from 90 to 200 μm/pixel. Experiments were conducted under three different plate impact configurations to measure spatially resolved free surface velocity and validate the experimental technique. First, a normal impact experiment was conducted on polycarbonate to measure the macroscopic full-field normal free surface velocity. Second, an isentropic compression experiment on Y-cut quartz–tungsten carbide assembly is performed to measure the particle velocity for experiments involving ramp compression waves. To explore the capability of the technique in multiaxial loading conditions, a pressure shear plate impact experiment was conducted to measure both the normal and transverse free surface velocities under combined normal and shear loading. The velocities measured in the experiments using digital image correlation are validated against previous data obtained from laser interferometry. Numerical simulations were also performed using established material models to compare and validate the experimental velocity profiles for these different impact configurations. The novel ability of the employed experimental setup to measure full-field free surface velocities with high spatial resolutions in shock compression experiments is demonstrated for the first time in this work.

47 OTHER INSTRUMENTATION↗

Two-Fluid and Discrete Element Modeling of a Parallel Plate Fluidized Bed Heat Exchanger for Concentrating Solar Power

A novel high-temperature particle solar receiver is developed using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a fluidized bed at the lower section, leaving the system from the bottom at a constant flowrate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built by collaborators at the Colorado School of Mines and their data are used for model validation. In this experimental setup, near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using the discrete element method and a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A new continuum conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2 K.

concentrating solar power↗

Pascal conductance series in ballistic one-dimensional LaAlO 3 /SrTiO 3 channels

One-dimensional electronic systems can support exotic collective phases because of the enhanced role of electron correlations. We describe the experimental observation of a series of quantized conductance steps within strongly interacting electron waveguides formed at the lanthanum aluminate–strontium titanate (LaAlO 3 /SrTiO 3 ) interface. The waveguide conductance follows a characteristic sequence within Pascal’s triangle: (1, 3, 6, 10, 15, …) e 2 /h , where e is the electron charge and h is the Planck constant. This behavior is consistent with the existence of a family of degenerate quantum liquids formed from bound states of n = 2, 3, 4, … electrons. Our experimental setup could provide a setting for solid-state analogs of a wide range of composite fermionic phases.

Science & Technology - Other Topics↗

Transition Fracture Toughness Characterization of Eurofer 97 Steel using Pre-Cracked Miniature Multi-notch Bend Bar Specimens

In this report, we present the feasibility study of using pre-cracked miniature multi-notch bend bar specimens (M4CVN) with a dimension of 45mm (length) x 3.3mm (width) x 1.65mm (thickness) to characterize the transition fracture toughness of Eurofer97 based on the ASTM E1921 Master Curve method. From literature survey results, we did not find any obvious specimen size effects on the measured fracture toughness of unirradiated Eurofer97. Nonetheless, in order to exclude the specimen size effect on the measured fracture toughness of neutron irradiated Eurofer97, comparison of results obtained from larger size specimens with those from smaller size specimens after neutron irradiation is necessary, which is not practical and can be formidably expensive. However, limited literature results indicate that the transition fracture toughness of Eurofer97 obtained from different specimen sizes and geometries followed the similar irradiation embrittlement trend. We then described the newly designed experimental setup to be used for testing neutron irradiated Eurofer97 pre-cracked M4CVN bend bars in the hot cell. We recently used the same setup for testing neutron irradiated F82H pre-cracked miniature multi-notch bend bars with great success. Considering the similarity in materials, specimen types, and the nature of tests between Eurofer97 and F82H, we believe the newly designed experimental setup can be used successfully in fracture toughness testing of Eurofer97 pre-cracked M4CVN specimens.

36 MATERIALS SCIENCE↗

The physics potential of a reactor neutrino experiment with Skipper-CCDs: searching for new physics with light mediators

In this work, we explore the sensitivity to new physics of the recently proposed vIOLETA experiment: a 10 kg Skipper Charged Coupled Device detector deployed 12 meters away from a commercial nuclear reactor core. We investigate two broad classes of models which benefit from the very low energy recoil threshold of these detectors, namely neutrino magnetic moments and light mediators coupled to neutrinos and quarks or electrons. We find that this experimental setup is very sensitive to light, weakly coupled new physics, and in particular that it could probe potential explanations of the event excess observed in XENON1T. We also provide a detailed study on the dependence of the sensitivity on the experimental setup assumptions and on the neutrino flux systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ measurement of surface potential developed on MgO thin film surface under ion irradiation using ion scattering spectroscopy

The application of ion scattering spectroscopy (ISS) to the in situ measurement of the surface potential developed on an insulator surface under positive ion irradiation was investigated. The ISS spectra measured for a MgO film of 600 nm thickness on a Si substrate by the irradiation of 950 eV He{sup +} ions revealed that the surface is positively charged by approximately 180 V. For accurate measurement of the surface potential, a correction to take into account the angular deflection of primary ions induced by the high surface potential is required. The dependence of the surface potential on the sample temperature revealed that no charging is induced above 700 deg. C, indicating that accumulated charges can be removed by heating to 700 deg. C. From the measurement of the ion-induced secondary electron yield using a collector electrode located in front of the sample surface, the surface potential and ion-induced secondary electron yield were found to be strongly affected by the experimental setup. Secondary electrons produced by the impact of slow positive secondary ions, the maximum energy of which corresponds to the surface potential, play an important role when the bias voltage applied to the collector electrode is positively high for the present experimental setup. The surface potential developed on the surface of MgO films of 600 and 200 nm thickness was measured in situ, revealing that the amount of accumulated charges and the time required to attain the steady state of charging are slightly dependent on the beam current of primary ions and strongly dependent on the thickness of the MgO film. The present results confirmed that the application of ISS has high potential for investigating charging phenomena and the secondary electron emission from insulator surfaces under positive ion irradiation.

36 MATERIALS SCIENCE↗