Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Simultaneous measurement of specific heat and thermal conductivity in pulsed magnetic fields

Here we report an experimental setup for simultaneously measuring specific heat and thermal conductivity in feedback-controlled pulsed magnetic fields of 50 ms duration at cryogenic temperatures. A stabilized magnetic field pulse obtained by the feedback control, which dramatically improves the thermal stability of the setup and sample, is used in combination with the flash method to obtain absolute values of thermal properties up to 37.2 T in the 22–16 K temperature range. We describe the experimental setup and demonstrate the performance of the present method with measurements on single-crystal samples of the geometrically frustrated quantum spin-dimer system SrCu 2 (BO 3 ) 2 . Our proof-of-principle results show excellent agreement with data taken using a standard steady-state method, confirming the validity and convenience of the present approach.

47 OTHER INSTRUMENTATION↗

The Halls B and C semi-inclusive deep inelastic scattering program towards the transverse momentum dependence of valence quarks

Inclusive and semi-inclusive deep inelastic scattering (DIS and SIDIS) are important tools for understanding the structure of nucleons and nuclei. Spin asymmetries in polarized SIDIS are directly related to transverse momentum dependent parton distributions (TMDs) and fragmentation functions. The usual collinear parton distribution functions depend on the fraction of hadron momentum carried by the parton, x, and the space-time resolution scale, Q2. The TMDs, which depend also on the intrinsic transverse momentum of the parton, kT, provide a three-dimensional partonic picture of the nucleon in momentum space. These TMDs have not yet been studied in detail. The 12 GeV era at JLab can move this to a new level of sophistication, thanks to the extraordinary statistical accuracy achievable and the extended kinematic reach provided by the 11 GeV beam. This calls for a multi-pronged approach with multi-dimensional data, for all combinations of beam and target polarization, and different hadrons. Hall B with its large-acceptance CLAS12 spectrometer will likely be the workhorse of SIDIS physics to provide multi-dimensional cross sections, azimuthal distributions and single- and double-spin asymmetries, using both unpolarized and polarized proton and deuteron targets, and unpolarized nuclear targets. The much-anticipated addition of a RICH detector to the CLAS12 base equipment will start an unprecedented SIDIS program with kaons, giving insights to the strange flavor dependence of the TMDs. Hall C with its "pinhole" magnetic spectrometer pair would add precision cross sections and their ratios for both pions and kaons. The rigid connection to the pivot allows for longitudinal-transverse separations, unique amongst the Hall experimental setups. Given the relative simplicity to change the magnet polarities, and the anticipated large reproducibility and systematic understanding of the spectrometer setup, Hall C will be the best place for 1%-level measurements of ?+/?? ratios, or kaon ratios, and due to its precision will allow for longitudinal-transverse separations, unique amongst the Hall experimental setups. Disadvantage of the setup is the lack of full azimuthal coverage at larger pT. The multi-pronged SIDIS approach combining foreseen 12-GeV experiments in large acceptance Hall B and precision Hall C will be presented.

Ent, Rolf↗

Direct speciation analysis of arsenic in sub-cellular compartments using micro-X-ray absorption spectroscopy

Identification of arsenic chemical species at a sub-cellular level is a key to understanding the mechanisms involved in arsenic toxicology and antitumor pharmacology. When performed with a microbeam, X-ray absorption near-edge structure ({mu}-XANES) enables the direct speciation analysis of arsenic in sub-cellular compartments avoiding cell fractionation and other preparation steps that might modify the chemical species. This methodology couples tracking of cellular organelles in a single cell by confocal or epifluorescence microscopy with local analysis of chemical species by {mu}-XANES. Here we report the results obtained with a {mu}-XANES experimental setup based on Kirkpatrick-Baez X-ray focusing optics that maintains high flux of incoming radiation (>10{sup 11} ph/s) at micrometric spatial resolution (1.5x4.0 {mu}m{sup 2}). This original experimental setup enabled the direct speciation analysis of arsenic in sub-cellular organelles with a 10{sup -15} g detection limit. {mu}-XANES shows that inorganic arsenite, As(OH){sub 3}, is the main form of arsenic in the cytosol, nucleus, and mitochondrial network of cultured cancer cells exposed to As{sub 2}O{sub 3}. On the other hand, a predominance of As(III) species is observed in HepG2 cells exposed to As(OH){sub 3} with, in some cases, oxidation to a pentavalent form in nuclear structures of HepG2 cells. The observation of intra-nuclear mixed redox states suggests an inter-individual variability in a cell population that can only be evidenced with direct sub-cellular speciation analysis.

60 APPLIED LIFE SCIENCES↗

Three-dimensional full-field velocity measurements in shock compression experiments using stereo digital image correlation

Shock compression plate impact experiments conventionally rely on point-wise velocimetry measurements based on laser-based interferometric techniques. This study presents an experimental methodology to measure the free surface full-field particle velocity in shock compression experiments using high-speed imaging and three-dimensional (3D) digital image correlation (DIC). The experimental setup has a temporal resolution of 100 ns with a spatial resolution varying from 90 to 200 μm/pixel. Experiments were conducted under three different plate impact configurations to measure spatially resolved free surface velocity and validate the experimental technique. First, a normal impact experiment was conducted on polycarbonate to measure the macroscopic full-field normal free surface velocity. Second, an isentropic compression experiment on Y-cut quartz–tungsten carbide assembly is performed to measure the particle velocity for experiments involving ramp compression waves. To explore the capability of the technique in multiaxial loading conditions, a pressure shear plate impact experiment was conducted to measure both the normal and transverse free surface velocities under combined normal and shear loading. The velocities measured in the experiments using digital image correlation are validated against previous data obtained from laser interferometry. Numerical simulations were also performed using established material models to compare and validate the experimental velocity profiles for these different impact configurations. The novel ability of the employed experimental setup to measure full-field free surface velocities with high spatial resolutions in shock compression experiments is demonstrated for the first time in this work.

47 OTHER INSTRUMENTATION↗

Two-Fluid and Discrete Element Modeling of a Parallel Plate Fluidized Bed Heat Exchanger for Concentrating Solar Power

A novel high-temperature particle solar receiver is developed using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a fluidized bed at the lower section, leaving the system from the bottom at a constant flowrate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built by collaborators at the Colorado School of Mines and their data are used for model validation. In this experimental setup, near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using the discrete element method and a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A new continuum conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2 K.

concentrating solar power↗

Pascal conductance series in ballistic one-dimensional LaAlO 3 /SrTiO 3 channels

One-dimensional electronic systems can support exotic collective phases because of the enhanced role of electron correlations. We describe the experimental observation of a series of quantized conductance steps within strongly interacting electron waveguides formed at the lanthanum aluminate–strontium titanate (LaAlO 3 /SrTiO 3 ) interface. The waveguide conductance follows a characteristic sequence within Pascal’s triangle: (1, 3, 6, 10, 15, …) e 2 /h , where e is the electron charge and h is the Planck constant. This behavior is consistent with the existence of a family of degenerate quantum liquids formed from bound states of n = 2, 3, 4, … electrons. Our experimental setup could provide a setting for solid-state analogs of a wide range of composite fermionic phases.

Science & Technology - Other Topics↗

Transition Fracture Toughness Characterization of Eurofer 97 Steel using Pre-Cracked Miniature Multi-notch Bend Bar Specimens

In this report, we present the feasibility study of using pre-cracked miniature multi-notch bend bar specimens (M4CVN) with a dimension of 45mm (length) x 3.3mm (width) x 1.65mm (thickness) to characterize the transition fracture toughness of Eurofer97 based on the ASTM E1921 Master Curve method. From literature survey results, we did not find any obvious specimen size effects on the measured fracture toughness of unirradiated Eurofer97. Nonetheless, in order to exclude the specimen size effect on the measured fracture toughness of neutron irradiated Eurofer97, comparison of results obtained from larger size specimens with those from smaller size specimens after neutron irradiation is necessary, which is not practical and can be formidably expensive. However, limited literature results indicate that the transition fracture toughness of Eurofer97 obtained from different specimen sizes and geometries followed the similar irradiation embrittlement trend. We then described the newly designed experimental setup to be used for testing neutron irradiated Eurofer97 pre-cracked M4CVN bend bars in the hot cell. We recently used the same setup for testing neutron irradiated F82H pre-cracked miniature multi-notch bend bars with great success. Considering the similarity in materials, specimen types, and the nature of tests between Eurofer97 and F82H, we believe the newly designed experimental setup can be used successfully in fracture toughness testing of Eurofer97 pre-cracked M4CVN specimens.

36 MATERIALS SCIENCE↗

The physics potential of a reactor neutrino experiment with Skipper-CCDs: searching for new physics with light mediators

In this work, we explore the sensitivity to new physics of the recently proposed vIOLETA experiment: a 10 kg Skipper Charged Coupled Device detector deployed 12 meters away from a commercial nuclear reactor core. We investigate two broad classes of models which benefit from the very low energy recoil threshold of these detectors, namely neutrino magnetic moments and light mediators coupled to neutrinos and quarks or electrons. We find that this experimental setup is very sensitive to light, weakly coupled new physics, and in particular that it could probe potential explanations of the event excess observed in XENON1T. We also provide a detailed study on the dependence of the sensitivity on the experimental setup assumptions and on the neutrino flux systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ measurement of surface potential developed on MgO thin film surface under ion irradiation using ion scattering spectroscopy

The application of ion scattering spectroscopy (ISS) to the in situ measurement of the surface potential developed on an insulator surface under positive ion irradiation was investigated. The ISS spectra measured for a MgO film of 600 nm thickness on a Si substrate by the irradiation of 950 eV He{sup +} ions revealed that the surface is positively charged by approximately 180 V. For accurate measurement of the surface potential, a correction to take into account the angular deflection of primary ions induced by the high surface potential is required. The dependence of the surface potential on the sample temperature revealed that no charging is induced above 700 deg. C, indicating that accumulated charges can be removed by heating to 700 deg. C. From the measurement of the ion-induced secondary electron yield using a collector electrode located in front of the sample surface, the surface potential and ion-induced secondary electron yield were found to be strongly affected by the experimental setup. Secondary electrons produced by the impact of slow positive secondary ions, the maximum energy of which corresponds to the surface potential, play an important role when the bias voltage applied to the collector electrode is positively high for the present experimental setup. The surface potential developed on the surface of MgO films of 600 and 200 nm thickness was measured in situ, revealing that the amount of accumulated charges and the time required to attain the steady state of charging are slightly dependent on the beam current of primary ions and strongly dependent on the thickness of the MgO film. The present results confirmed that the application of ISS has high potential for investigating charging phenomena and the secondary electron emission from insulator surfaces under positive ion irradiation.

36 MATERIALS SCIENCE↗

An analytical and numerical study of the nonlinear reflection at a stress-free surface

Implementation of the ultrasonic second harmonic generation has typically been restricted to simple setups such as through-transmission or Rayleigh surface waves. Recent research has evaluated the second harmonic waves generation in P- and SV- waves reflected from a stress-free surface to enable the single-sided interrogation of a specimen. This research considers the second harmonic generation in an aluminum specimen, which is analytically evaluated using an approach based on a perturbation method. Here, the model is chosen to mimic an experimental setup where the longitudinal wave is generated at oblique angle using a wedge transducer. Due to the mode conversion at the interface of the wedge and the specimen, it is necessary to evaluate longitudinal and shear waves, determining all second harmonic waves generated in the bulk and at the stress-free boundary. The theoretically developed model is then implemented in a commercial finite element code, COMSOL, using increasing fundamental wave amplitudes for different values of third order elastic constants. The results of this computational model verify the analytical approach and the proposed measurement setup, taking into account assumptions and approximations of the solution procedure. Furthermore, the computational model is used to draw important conclusions relevant to the experimental setup, including the need to avoid interaction with diffracted waves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the high energy component of the x-ray spectra in the VENUS electron cyclotron resonance ion source (abstract only)

High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (versatile ECR for nuclear science), produce large amounts of x rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental setup to measure bremsstrahlung spectra from ECR ion sources is somewhat different than for the traditional nuclear physics measurements these detectors are generally used for. In particular, the collimation and background shielding can be problematic. In this paper we will discuss the experimental setup for such a measurement, the energy calibration and background reduction, the shielding of the detector, and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates in dependence of various ion source parameters such as confinement fields, minimum B-field, rf power, and heating frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous photonic generation of multiple chirp and unchirp microwave waveform with frequency multiplying capability for optical beam forming system

A photonic technique based on the Mach–Zehnder Modulator and the dual parallel Mach–Zehnder modulator is proposed for the simultaneous generation of multiple chirp and unchirp microwave waveform with frequency multiplying capability for efficient beam steering applications. There is provision to obtain a single chirp signal of a particular center frequency and chirp rate from a multiple chirp signal without any alternation in the experimental setup. In the proposed methodology, the PIN photodetector is used for the detection of 12 GHz unchirp microwave waveform showing the frequency doubling characteristics and the balance photodetector is used for the detection of multiple chirp signal with frequency components 6, 12, and 18 GHz. The same experimental setup is used to generate dual linear chirp microwave signal of 12 GHz center frequency. This can be achieved by adjusting the bias voltage of the phase modulator. Time bandwidth product and bandwidth of the signal are 18.33 and 410 MHz, respectively. This technique is tunable in frequency, but the generation of higher frequency microwave signals is limited by the speed and bandwidth of the Mach–Zehnder Modulator and photodetector. The novelty of our proposed scheme is that we are going to drive MZM by chirp RF signal to multiply the chirp rate in manifold. To the best of our knowledge the effect of chirp microwave signal on photonic highly steerable beam forming system has not yet been studied experimentally in past, which we are targeting under this paper. It is expected that the range of beam steering performance should be improved substantially as compared to previously reported results.

42 ENGINEERING↗

Measurement of the high energy component of the x-ray spectra in the VENUS electron cyclotron resonance ion source

High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (Versatile ECR for NUclear Science), produce large amounts of x-rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet, adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental setup to measure bremsstrahlung spectra from ECR ion sources is somewhat different from that for the traditional nuclear physics measurements these detectors are generally used for. In particular, the collimation and background shielding can be problematic. In this paper, we will discuss the experimental setup for such a measurement, the energy calibration and background reduction, the shielding of the detector, and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates depending on various ion source parameters, such as confinement fields, minimum B-field, rf power, and heating frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization Simulations for a Gamma-Ray Calibration Standard for a Cyclic Neutron Activation Analysis Pneumatic System at the Penn State Breazeale Reactor

For new experimental setups, the initial testing and calibrations can be expensive and time consuming without prior optimization. However, these issues can be mitigated using realistic modeling and simulation studies of the proposed system a priori. Specifically, an experiment can be performed virtually using realistic simulations and the expected results evaluated to inform adjustments of the experimental setup to achieve optimum results. At the Penn State Breazeale Reactor, a new pneumatic transfer system has been developed for the detection and characterization of short-lived fission fragments to enhance and complement existing nuclear data. The system accomplishes this task by transporting samples cyclically between an assortment of gamma-ray/neutron detectors and the reactor-core vicinity with sub-second transit times. The measured neutron flux paired with simulations of detector response using Geant4 and a custom module for estimating cascade summing effects and corrections were used to select sample-material masses for system characterization. With the optimized sample masses, an experimental counting plan for characterizing the repeatability of the newly developed pneumatic system was developed. Finally, the predictions made with these simulations allowed for optimization of the irradiation sample characteristics and gamma-ray detection system.

cyclic neutron activation, gamma-ray spectroscopy↗

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cross-Scale Land-Atmosphere Experiment Field Campaign Report

The experimental setup was installed in 2017. It is located adjacent to the world’s largest and most extensive climate research facility, the Southern Great Plains (SGP) atmospheric observatory, which was established by the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility. This site was selected due to the abundance of environmental data that can support the proposed project. The location and layout of the experimental setup are presented in Figure 1. The site extends through two agricultural fields separated by the Coal Road. One agricultural field (hereafter called “the homogeneous site”) contains a relatively homogeneous soil composition and a homogeneous alfalfa vegetation cover. The other agricultural field (hereafter called “the heterogeneous site”) extends through two different soil compositions and is covered by two vegetation covers, which are different in type and coverage ratio.

54 ENVIRONMENTAL SCIENCES↗

An experimental and computational investigation of the standard temperature-pressure correction factor for ion chambers in kilovoltage x rays

For ion chambers with cavities open to the surrounding atmosphere, the response measured at a given temperature and pressure must be corrected using the standard temperature-pressure correction factor (P{sub TP}). A previous paper based solely on Monte Carlo simulations [D. J. La Russa and D. W. O. Rogers, Med. Phys. 33, 4590-4599 (2006)] pointed out the shortcomings of the P{sub TP} correction factor when used to correct the response of non-air-equivalent chambers for low-energy x-ray beams. This work presents the results of several experiments that corroborate these calculations for a number of ion chambers. Monte Carlo simulations of the experimental setup revealed additional insight into the various factors affecting the extent of the breakdown of P{sub TP}, including the effect of impurities and the sensitivity to chamber dimensions. For an unfiltered 60 kV beam, the P{sub TP}-corrected response of an NE 2571 ion chamber measured at 0.7 atm was 2.5% below the response measured at reference conditions. In general, Monte Carlo simulations of the experimental setup using EGSnrc were within 0.5% of measured values. EGSnrc-calculated values of air kerma calibration coefficients (N{sub K}) at low x-ray energies are also provided as a means of estimating the level of impurities in the chambers investigated. Calculated values of N{sub K} normalized to the value measured for a 250 kV beam were obtained for three chambers and were within 1% of experiment with one exception, the Exradin A12 in a 50 kV beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

The physics potential of a reactor neutrino experiment with Skipper CCDs: Measuring the weak mixing angle

We analyze in detail the physics potential of an experiment like the one recently proposed by the vIOLETA collaboration: a kilogram-scale Skipper CCD detector deployed 12 meters away from a commercial nuclear reactor core. This experiment would be able to detect coherent elastic neutrino nucleus scattering from reactor neutrinos, capitalizing on the exceptionally low ionization energy threshold of Skipper CCDs. To estimate the physics reach, we elect the measurement of the weak mixing angle as a case study. We choose a realistic benchmark experimental setup and perform variations on this benchmark to understand the role of quenching factor and its systematic uncertainties, background rate and spectral shape, total exposure, and reactor antineutrino flux uncertainty. We take full advantage of the reactor flux measurement of the Daya Bay collaboration to perform a data driven analysis which is, up to a certain extent, independent of the theoretical un- certainties on the reactor antineutrino flux. We show that, under reasonable assumptions, this experimental setup may provide a competitive measurement of the weak mixing angle at few MeV scale with neutrino-nucleus scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗