Search NASA⌕ Search

SEARCH · Search NASA

Results for “facing direction detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Zero-crosstalk silicon photonic refractive index sensor with subwavelength gratings

Abstract Silicon photonic index sensors have received significant attention for label-free bio and gas-sensing applications, offering cost-effective and scalable solutions. Here, we introduce an ultra-compact silicon photonic refractive index sensor that leverages zero-crosstalk singularity responses enabled by subwavelength gratings. The subwavelength gratings are precisely engineered to achieve an anisotropic perturbation-led zero-crosstalk, resulting in a single transmission dip singularity in the spectrum that is independent of device length. The sensor is optimized for the transverse magnetic mode operation, where the subwavelength gratings are arranged perpendicular to the propagation direction to support a leaky-like mode and maximize the evanescent field interaction with the analyte space. Experimental results demonstrate a high wavelength sensitivity of − 410 nm/RIU and an intensity sensitivity of 395 dB/RIU, with a compact device footprint of approximately 82.8 μm 2 . Distinct from other resonant and interferometric sensors, our approach provides an FSR-free single-dip spectral response on a small device footprint, overcoming common challenges faced by traditional sensors, such as signal/phase ambiguity, sensitivity fading, limited detection range, and the necessity for large device footprints. This makes our sensor ideal for simplified intensity interrogation. The proposed sensor holds promise for a range of on-chip refractive index sensing applications, from gas to biochemical detection, representing a significant step towards efficient and miniaturized photonic sensing solutions. Graphical Abstract

Materials Science↗

Results of the examination of the Skylab/Apollo windows for micrometeroid impacts

Examination of the Command Module windows of the Skylab/Apollo 3 and 4 spacecraft at 5x magnification resulted in the detection of 18 micrometeroid craters 80 microns and larger in diameter for an accumulated exposure time of 144 days. A 20x magnification examination of the windows of the Skylab/Apollo 4 spacecraft identified 6 such craters between 20 and 70 microns in diameter for 84 days exposure. As the Skylab was oriented such that its solar panels faced the sun continuously, the three windows examined had a fixed orientation also. The six small craters were all found on the window that faced in the solar direction. A cumulative flux per square centimeter per year is given for pit and spall diameters.

Cour-Palais, B. G.↗

ALMA Reveals a Misaligned Inner Gas Disk inside the Large Cavity of a Transitional Disk

Pairs of azimuthal intensity decrements at near-symmetric locations have been seen in a number of protoplanetary disks. They are most commonly interpreted as the two shadows cast by a highly misaligned inner disk. Direct evidence of such an inner disk, however, remains largely illusive, except in rare cases. In 2012, a pair of such shadows were discovered in scattered-light observations of the near face-on disk around 2MASS J16042165- 2130284, a transitional object with a cavity ∼60 au in radius. The star itself is a “dipper,” with quasi-periodic dimming events on its light curve, commonly hypothesized as caused by extinctions by transiting dusty structures in the inner disk. Here, we report the detection of a gas disk inside the cavity using Atacama Large Millimeter/ submillimeter Array (ALMA) observations with ∼0".2 angular resolution. A twisted butterfly pattern is found in the moment 1 map of the CO (3–2) emission line toward the center, which is the key signature of a high misalignment between the inner and outer disks. In addition, the counterparts of the shadows are seen in both dust continuum emission and gas emission maps, consistent with these regions being cooler than their surroundings. Our findings strongly support the hypothesized misaligned inner disk origin of the shadows in the J1604-2130 disk. Finally, the inclination of the inner disk would be close to −45° in contrast with 45°; it is possible that its internal asymmetric structures cause the variations on the light curve of the host star.

azimuthal intensity decrements↗

An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s (18.0 l/min) for the mono-directional sensor and a measurement range of {+-}3.00 Multiplication-Sign 10{sup -4} m{sup 3}/s ({+-}18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the coefficient of determination r{sup 2} is equal to 0.997; for the bi-directional configuration, the coefficient of determination r{sup 2} is equal to 0.990 for positive flows (inspiration) and 0.988 for negative flows (expiration). Measurement uncertainty {delta}Q of air flow rate has been evaluated by means of the propagation of distributions and the percentage error in the arrangement of bi-directional sensor ranges from a minimum of about 0.5% at -18.0 l/min to a maximum of about 9% at -12.0 l/min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary geologic analyses of SIR-B radar data for Hawaii

A number of distinct topographic and textural units were discerned on SIR-B radar images of the Kilauea/Kau Desert area. The SIR-B enhanced large-scale topographic features, such as the Kahuku Pali and the Koae Faults (both oriented towards the radar antenna), while it was unable to detect features facing away from the radar antenna such as the Hilina and Kaoiki Pali. Textural units which were identified on the SIR-B images include aa flows of various ages, and several pyroclastic units. The extreme surface roughness of aa flows produced high radar returns on both the 28 deg and 48 deg SIR-B data sets. In contrast, pahoehoe flows produced smooth, low return units which were difficult to distinguish from surrounding radar-dark materials. It is suggested that multilook direction data, acquired at steeper incidence angles during a reflight of SIR-B, may aid in the further identification of pahoehoe flows and subtle topographic features.

Gaddis, L. R.↗

Deep Analysis Net with Causal Embedding for Coal-fired Power Plant Fault Detection and Diagnosis (DANCE4CFDD)

Fault detection and diagnosis is critical to power plant operation to ensure attaining high reliability while reducing operation cost. As more renewable power is introduced to the power grid, traditional fossil power plants take on the extra burden of excessive load cycling to compensate the generation variability from renewable power. Such load cycling will pose more reliability challenges to power plant operation. There are a number of challenges faced by today’s asset health management system in coal- fired (or gas) power plants: 1) high-dimensional nonlinear interaction among multiple time series measurements; 2) high measurement variance induced by operational conditions/modes; 3) variation among asset types and plant configurations; and 4) a small number of faulty events to learn from. To cope with these challenges, today’s fielded asset health management systems rely heavily on manual efforts from domain experts and hand-crafted features or rules based on domain knowledge. Despite its role in plant reliability, such a practice is costly and hinders its scalability and sustainability, particularly when a plant undergoes modifications. The objective of this project is to develop a novel end-to-end AI learning system that is trainable (i.e., the AI representation of a complex system behavior can be directly learned from properly labeled data) for accurate fault detection and root cause analysis. The ability to create a fault detection model directly from time series could alleviate the efforts associated with today’s asset management solution development. In the course of this project, we have achieved the following: Created an AI model development environment incorporating state-of-the-art neural network architectures for rapid model development and evaluation; Developed novel learning strategies for training of fault detection model; Developed special-purpose neural network architecture embedded with variable association graph aiming for better interpretability; Developed a learning strategy to leverage a small number of faulty events for enhanced fault detection capability; Conducted detailed experimental study based on public benchmark datasets and demonstrated the effectiveness of the proposed solution; and Validated the developed system with data from both a coal-fired plant boiler dynamic simulation model and real-world coal-fired power plant covering multiple asset and fault types. Overall, the project attained a technology readiness level of TRL 5 from TRL 2 at the beginning of the project.

20 FOSSIL-FUELED POWER PLANTS↗

Light new physics in XENON1T

We examine the recently-reported low-energy electron recoil spectrum observed at the XENON1T underground dark matter direct detection experiment, in the context of new interactions with solar neutrinos. In particular we show that scalar and vector mediators with masses $\lesssim 50$ keV coupled to leptons could already leave a visible signature in the XENON1T experiment, similar to the observed peak below 7 keV. This signals that dark matter detectors are already competing with neutrino scattering experiments such as GEMMA, CHARM-II and Borexino. If these results from XENON1T are interpreted as a new signal of such physics, the parameters which fit the excess face challenges from astrophysics which seem very difficult to overcome. If they are rather viewed as a constraint on new couplings, they herald the start of an era of novel precise probes of physics beyond the standard model with dark matter detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

Rapid sensing of hidden objects and defects using a single-pixel diffractive terahertz sensor

Abstract Terahertz waves offer advantages for nondestructive detection of hidden objects/defects in materials, as they can penetrate most optically-opaque materials. However, existing terahertz inspection systems face throughput and accuracy restrictions due to their limited imaging speed and resolution. Furthermore, machine-vision-based systems using large-pixel-count imaging encounter bottlenecks due to their data storage, transmission and processing requirements. Here, we report a diffractive sensor that rapidly detects hidden defects/objects within a 3D sample using a single-pixel terahertz detector, eliminating sample scanning or image formation/processing. Leveraging deep-learning-optimized diffractive layers, this diffractive sensor can all-optically probe the 3D structural information of samples by outputting a spectrum, directly indicating the presence/absence of hidden structures or defects. We experimentally validated this framework using a single-pixel terahertz time-domain spectroscopy set-up and 3D-printed diffractive layers, successfully detecting unknown hidden defects inside silicon samples. This technique is valuable for applications including security screening, biomedical sensing and industrial quality control.

Li, Jingxi (ORCID:0000000165958680)↗

Machine Learning-based Intrusion Detection for Smart Grid Computing: A Survey

Machine learning (ML)-based intrusion detection system (IDS) approaches have been significantly applied and advanced the state-of-the-art system security and defense mechanisms. In smart grid computing environments, security threats have been significantly increased as shared networks are commonly used, along with the associated vulnerabilities. However, compared to other network environments, ML-based IDS research in a smart grid is relatively unexplored, although the smart grid environment is facing serious security threats due to its unique environmental vulnerabilities. In this article, we conducted an extensive survey on ML-based IDS in smart grids based on the following key aspects: (1) The applications of the ML-based IDS in transmission and distribution side power components of a smart power grid by addressing its security vulnerabilities; (2) dataset generation process and its usage in applying ML-based IDSs in the smart grid; (3) a wide range of ML-based IDSs used by the surveyed papers in the smart grid environment; (4) metrics, complexity analysis, and evaluation testbeds of the IDSs applied in the smart grid; and (5) lessons learned, insights, and future research directions.

SCADA↗

Crack Identification and Characterization in Deformed Nb3Sn Rutherford Cable Stacks Using Machine Learning

An investigation of instance segmentation of cracks in Nb3Sn 4-stack 40-strand Rutherford cables using machine learning is presented. Three samples were uniaxially and biaxially loaded before metallographic inspections were performed. The Mask R-CNN model was used in the Detectron2 framework with pre-trained weights but fine-tuned to detect and segment cracks. The model detected cracks with bounding box and mask average precisions (AP) of 42.8 and 27.9, respectively, and was used for instance segmentation of all cracks in the three samples. More cracks were found in the sample pre-loaded along the z-axis (i.e., along the cable length). Pre-loading along the x-axis (i.e., on the cables edges) reduced the number of cracks and changed the crack orientation distribution, away from being highly aligned with the y-axis (i.e., normal to the cables broad faces), i.e., the direction with the highest applied load. Fine-tuning of the Segment Anything Model (SAM) was also studied but performed poorly without human-provided prompts. However, the zero-shot capability of SAM showed high promises to accelerate the image annotation process for applications beyond this study.

Croteau, Jean-Francois↗

Local Sensitivities of the Gulf Stream Separationa

Abstract Robust and accurate Gulf Stream separation remains an unsolved problem in general circulation modeling whose resolution will positively impact the ocean and climate modeling communities. Oceanographic literature does not face a shortage of plausible hypotheses that attempt to explain the dynamics of the Gulf Stream separation, yet a single theory that the community agrees on is missing. In this paper, the authors investigate the impact of the deep western boundary current (DWBC), coastline curvature, and continental shelf steepening on the Gulf Stream separation within regional configurations of the Massachusetts Institute of Technology General Circulation Model. Artificial modifications to the regional bathymetry are introduced to investigate the sensitivity of the separation to each of these factors. Metrics for subsurface separation detection confirm the direct link between flow separation and the surface expression of the Gulf Stream in the Mid-Atlantic Bight. It is shown that the Gulf Stream separation and mean surface position are most sensitive to the continental slope steepening, consistent with a theory proposed by Melvin Stern in 1998. In contrast, the Gulf Stream separation exhibits minimal sensitivity to the presence of the DWBC and coastline curvature. The implications of these results to the development of a “separation recipe” for ocean modeling are discussed. This study concludes adequate topographic resolution is a necessary, but not sufficient, condition for proper Gulf Stream separation.

58 GEOSCIENCES↗

Detection and characterization of fatigue cracks in thin metal plates by low frequency resonant model analysis

Low-frequency resonant model analysis, a technique for the detection and characterization of fatigue cracks in thin metal plates, which could be adapted to rapid scan or large area testing, is considered. Experimental data displaying a direct correlation between fatigue crack geometry and resonance frequency for the second vibrational plate mode are presented. FEM is used to calculate the mechanical behavior of the plates, and provides a comparison basis for the experimentally determined resonance frequency values. The waveform of the acoustic emission generated at the resonant frequency is examined; it provides the basis for a model of the interaction of fatigue crack faces during plate vibration.

Wincheski, B.↗

An LDEF follow-on spacecraft concept

The successful flight, retrieval, and analyses of the Long Duration Exposure Facility (LDEF) experiments demonstrated the value of long duration space exposure for a broad spectrum of science and engineering investigations. The original LDEF was an excellent gravity gradient spacecraft, but because of its 9 m length and 9,700 kg mass it was difficult to manifest on the Shuttle, for either launch or retrieval, in conjunction with other payloads. This paper discusses an LDEF follow-on spacecraft concept whose short stowed length (approximately 3 m) greatly improves Shuttle manifesting opportunities while still providing very large surface area exposure for experiments. Deployable 'wings' on each end of the short, 'cylindrical' main body of this new spacecraft provide the means for gravity gradient stabilization while greatly increasing the spacecraft surface area. The center section of the spacecraft is oriented with the end faces of the twelve sided, 4.2 m diameter 'cylinder' perpendicular to the velocity vector thus providing large areas for experiments in both the ram and anti-ram directions as well as additional exposure area around the periphery of the cylinder. When deployed and properly oriented with the Shuttle's Remote Manipulator System (RMS), both wings of the spacecraft are oriented edge on to the direction of motion and lie in the plane which contains the local gravity vector. The relatively thin wings readily accommodate dual side exposure of glass plate stacks for cosmic ray detection. Flat surfaces mounted normal to and on the periphery of the wings provide additional areas in both the ram and anti-ram directions for cosmic dust, micrometeoroid, and orbital debris collection free of contamination from 'splatter' off secondary surfaces. The baseline concept provides enhancements not available on the original LDEF such as solar array generated electrical power and data telemetry. Status of the efforts to promote support for and ultimately space flight of this concept will be presented. Suggestions for improvements in the spacecraft design and proposed utilization are solicited.

Keller, Vernon↗

Development of a System for Rapid Detection of Contaminants in Water Supplies Using Magnetic Resonance and Nanoparticles

To keep the water supply safe and to ensure a swift and accurate response to a water supply contamination event, rapid and robust methods for microbial testing are necessary. Current technologies are complex, lengthy and costly and there is a need for rapid, reliable, and precise approaches that can readily address this fundamental security and safety issue. T2 Biosystems is focused on providing solutions to this problem by making breakthroughs in nanotechnology and biosensor techniques that address the current technical restrictions facing rapid, molecular analysis in complex samples. In order to apply the T2 Biosystems nucleic acid detection procedure to the analysis of nucleic acid targets in unprocessed water samples, Bacillus thuringeinsis was selected as a model organism and local river water was selected as the sample matrix. The initial assay reagent formulation was conceived with a manual magnetic resonance reader, was optimized using a high throughput system, and transferred back to the MR reader for potential field use. The final assay employing the designed and manufactured instruments was capable of detecting 10 CFU/mL of B. thuringiensis directly within the environmental water sample within 90 minutes. Further, discrimination of two closely related species of Bacilli was accomplished using the methods of this project; greater than 3-fold discrimination between B. cereus and B. thuringiensis at a concentrations spanning 10 CFU/mL to 10 5 CFU/mL was observed.

60 APPLIED LIFE SCIENCES↗

Crack detection in fuel cell electrodes using a spatial filtering technique for overcoming noisy backgrounds

Image processing is a powerful tool that allows for rapid and automated data parsing in settings that occupy large variable spaces and require large data sets. Feature detection on difficultly discerned backgrounds is a subset of image processing that facilitates the extraction of quantitative metrics from otherwise subjective data. Crack detection and quantification is an important capability in polymer electrolyte membrane fuel cell quality control, failure analysis, and optimization. This work presents a technique to perform crack detection and quantification which overcomes challenges faced by commonly used image segmentation techniques. We demonstrate the use of a geometrically filtered noise‐level detection technique to select a binary threshold value from which we then quantify how cracked a sample is. Furthermore, we demonstrate the accuracy of our technique using programmatically generated test images of known crack amounts and their performance on real‐world fuel cell catalyst layer samples.

30 DIRECT ENERGY CONVERSION↗

Structure and luminescence properties of silver-doped NaY(PO{sub 3}){sub 4} crystal

Single crystals of NaY(PO{sub 3}){sub 4} and Ag{sub 0.07}Na{sub 0.93}Y(PO{sub 3}){sub 4} have been synthesized by flux method. These new compounds turned out to be isostructural to NaLn(PO{sub 3}){sub 4}, with Ln=La, Nd, Gd and Er [monoclinic, P2{sub 1}/n, a=7.1615(2) A, b=13.0077(1) A, c=9.7032 (3) A, {beta}=90.55 (1){sup o}, V=903.86(14) A{sup 3} and Z=4]. The structure is based upon long polyphosphate chains running along the shortest unit-cell direction and made up of PO{sub 4} tetrahedra sharing two corners, linked to yttrium and sodium polyhedra. Infrared and Raman spectra at room temperature confirms this atomic arrangement. The luminescence of silver ions was reported in metaphosphate of composition Ag{sub 0.07}Na{sub 0.93}Y(PO{sub 3}){sub 4}. One luminescent centre was detected and assigned to single Ag{sup +} ions. - Graphical abstract: The presence of only one Ag{sup +} luminescence centre is the result from the perfect isolation (Ag{sup +}-Ag{sup +}=5.90 A) of each oxygenated silver site (AgO{sub 8} polyhedra) sharing two faces and one corner with three yttrium polyhedra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Gas and Star-formation in Low Surface Brightness Galaxies

We have obtained CO(J = 2−1) spectra of nine face-on low surface brightness galaxies using the JCMT 15 m telescope and observed Hα images using the 2.16 m telescope of NAOC. As no CO has been detected, only upper limits on the H{sub 2} masses are given. The upper limits of total molecular hydrogen masses are about (1.2--82.4)×10{sup 7} M{sub ⊙}. Their star-formation rates are mainly lower than 0.4 M{sub ⊙} yr{sup −1} and star-formation efficiencies are lower than 1.364×10{sup −10} yr{sup −1}. Our results show that the absence of molecular gas content is the direct reason for the low star-formation rate. The low star-formation efficiency probably resulted from the low efficiency of H i gas transforming to H{sub 2} gas.

79 ASTRONOMY AND ASTROPHYSICS↗