Search NASA⌕ Search

SEARCH · Search NASA

Results for “fan efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Generation After Next Propulsor Research: Robust Design for Embedded Engine Systems

The National Aeronautics and Space Administration, United Technologies Research Center and Virginia Polytechnic and State University have contracted to pursue multi-disciplinary research into boundary layer ingesting (BLI) propulsors for generation after next environmentally responsible subsonic fixed wing aircraft. This Robust Design for Embedded Engine Systems project first conducted a high-level vehicle system study based on a large commercial transport class hybrid wing body aircraft, which determined that a 3 to 5 percent reduction in fuel burn could be achieved over a 7,500 nanometer mission. Both pylon-mounted baseline and BLI propulsion systems were based on a low-pressure-ratio fan (1.35) in an ultra-high-bypass ratio engine (16), consistent with the next generation of advanced commercial turbofans. An optimized, coupled BLI inlet and fan system was subsequently designed to achieve performance targets identified in the system study. The resulting system possesses an inlet with total pressure losses less than 0.5%, and a fan stage with an efficiency debit of less than 1.5 percent relative to the pylon-mounted, clean-inflow baseline. The subject research project has identified tools and methodologies necessary for the design of next-generation, highly-airframe-integrated propulsion systems. These tools will be validated in future large-scale testing of the BLI inlet / fan system in NASA's 8 foot x 6 foot transonic wind tunnel. In addition, fan unsteady response to screen-generated total pressure distortion is being characterized experimentally in a JT15D engine test rig. These data will document engine sensitivities to distortion magnitude and spatial distribution, providing early insight into key physical processes that will control BLI propulsor design.

Arend, David J.↗

Performance Assessment of High-Efficiency Refrigerated Display Cases with Low-GWP Refrigerants: Preprint

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas (GHG) reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison was to assess the energy performance of two high efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513a, respectively. Performance of these display cases were compared to a baseline fixture using HFC (R-134a) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores, and small supermarkets. The high efficiency cases were equipped with energy efficient lighting, improved panel insulation, high efficiency evaporator and condenser fan motors, and high effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions. However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining target product temperature, the energy efficient fixtures containing R-290 and R-513a consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134a refrigerant. The daily energy consumption of the R-290, R-513a, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

The aerodynamic design and performance of the General Electric/NASA EEE fan

The aerodynamic design and test results of the fan and quarter-stage component for the GE/NASA Energy Efficient Engine (EEE) are presented. The fan is a high bypass ratio, single-stage design having 32 part-span shrouded rotor blades, coupled with a unique quarter-stage arrangement that provides additional core-stream pressure ratio and particle separation. The fan produces a bypass pressure ratio of 1.65 at the exit of the low aspect ratio vane/frame and a core-stream pressure ratio of 1.67 at the entrance to the core frame struts. The full-scale fan vehicle was instrumented, assembled and tested as a component in November 1981. Performance mapping was conducted over a range of speeds and bypass ratios using individually-controlled bypass and core-stream discharge valves. The fan bypass and core-stream test data showed excellent results, with the fan exceeding all performance goals at the important engine operating conditions.

Sullivan, T. J.↗

Distributed Turboelectric Propulsion for Hybrid Wing Body Aircraft

Meeting future goals for aircraft and air traffic system performance will require new airframes with more highly integrated propulsion. Previous studies have evaluated hybrid wing body (HWB) configurations with various numbers of engines and with increasing degrees of propulsion-airframe integration. A recently published configuration with 12 small engines partially embedded in a HWB aircraft, reviewed herein, serves as the airframe baseline for the new concept aircraft that is the subject of this paper. To achieve high cruise efficiency, a high lift-to-drag ratio HWB was adopted as the baseline airframe along with boundary layer ingestion inlets and distributed thrust nozzles to fill in the wakes generated by the vehicle. The distributed powered-lift propulsion concept for the baseline vehicle used a simple, high-lift-capable internally blown flap or jet flap system with a number of small high bypass ratio turbofan engines in the airframe. In that concept, the engine flow path from the inlet to the nozzle is direct and does not involve complicated internal ducts through the airframe to redistribute the engine flow. In addition, partially embedded engines, distributed along the upper surface of the HWB airframe, provide noise reduction through airframe shielding and promote jet flow mixing with the ambient airflow. To improve performance and to reduce noise and environmental impact even further, a drastic change in the propulsion system is proposed in this paper. The new concept adopts the previous baseline cruise-efficient short take-off and landing (CESTOL) airframe but employs a number of superconducting motors to drive the distributed fans rather than using many small conventional engines. The power to drive these electric fans is generated by two remotely located gas-turbine-driven superconducting generators. This arrangement allows many small partially embedded fans while retaining the superior efficiency of large core engines, which are physically separated but connected through electric power lines to the fans. This paper presents a brief description of the earlier CESTOL vehicle concept and the newly proposed electrically driven fan concept vehicle, using the previous CESTOL vehicle as a baseline.

Kim, Hyun Dae↗

Performance of two-stage fan having low-aspect-ratio first-stage rotor blading

The NASA two stage fan was tested with a low aspect ratio first stage rotor having no midspan dampers. At design speed the fan achieved an adiabatic design efficiency of 0.846, and peak efficiencies for the first stage and rotor of 0.870 and 0.906, respectively. Peak efficiency occurred very close to the stall line. In an attempt to improve stall margin, the fan was retested with circumferentially grooved casing treatment and with a series of stator blade resets. Results showed no improvement in stall margin with casing treatment but increased to 8 percent with stator blade reset.

Urasek, D. C.↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unsteady Flows in a Single-Stage Transonic Axial-Flow Fan Stator Row

Measurements of the unsteady velocity field within the stator row of a transonic axial-flow fan were acquired using a laser anemometer. Measurements were obtained on axisymmetric surfaces located at 10 and 50 percent span from the shroud, with the fan operating at maximum efficiency at design speed. The ensemble-average and variance of the measured velocities are used to identify rotor-wake-generated (deterministic) unsteadiness and turbulence, respectively. Correlations of both deterministic and turbulent velocity fluctuations provide information on the characteristics of unsteady interactions within the stator row. These correlations are derived from the Navier-Stokes equation in a manner similar to deriving the Reynolds stress terms, whereby various averaging operators are used to average the aperiodic, deterministic, and turbulent velocity fluctuations which are known to be present in multistage turbomachines. The correlations of deterministic and turbulent velocity fluctuations throughout the axial fan stator row are presented. In particular, amplification and attenuation of both types of unsteadiness are shown to occur within the stator blade passage.

Hathaway, Michael D.↗

Experimental quiet engine program aerodynamic performance of Fan C

This report presents the aerodynamic component test results of Fan C, a high-bypass-ratio, low-aerodynamic-loading, 1550 feet per second (472.4 m/sec), single-stage fan, which was designed and tested as part of the NASA Experimental Quiet Engine Program. The fan was designed to deliver a bypass pressure ratio of 1.60 with an adiabatic efficiency of 84.2 percent at a total fan flow of 915 lb/sec (415.0 kg/sec). It was tested with and without inlet distortion. A bypass total-pressure ratio of 1.61 and an adiabatic efficiency of 83.9 percent at a total fan flow of 921 lb/sec (417.8 kg/sec) were actually achieved. An operating margin in excess of 14.6 percent was demonstrated at design speed.

Giffin, R. G.↗

Coupled Analysis of an Inlet and Fan for a Quiet Supersonic Jet

A computational analysis of a Gulfstream isentropic external compression supersonic inlet coupled to a Rolls-Royce fan has been completed. The inlet was designed for a small, low sonic boom supersonic vehicle with a design cruise condition of M = 1.6 at 45,000 ft. The inlet design included an annular bypass duct that routed flow subsonically around an engine-mounted gearbox and diverted flow with high shock losses away from the fan tip. Two Reynolds-averaged Navier-Stokes codes were used for the analysis: an axisymmetric code called AVCS for the inlet and a three dimensional (3-D) code called SWIFT for the fan. The codes were coupled at a mixing plane boundary using a separate code for data exchange. The codes were used to determine the performance of the inlet/fan system at the design point and to predict the performance and operability of the system over the flight profile. At the design point the core inlet had a recovery of 96 percent, and the fan operated near its peak efficiency and pressure ratio. A large hub radial distortion generated in the inlet was not eliminated by the fan and could pose a challenge for subsequent booster stages. The system operated stably at all points along the flight profile. Reduced stall margin was seen at low altitude and Mach number where flow separated on the interior lips of the cowl and bypass ducts. The coupled analysis gave consistent solutions at all points on the flight profile that would be difficult or impossible to predict by analysis of isolated components.

Chima, Rodrick V.↗

Coupled Analysis of an Inlet and Fan for a Quiet Supersonic Aircraft

A computational analysis of a Gulfstream isentropic external compression supersonic inlet coupled to a Rolls-Royce fan was completed. The inlet was designed for a small, low sonic boom supersonic vehicle with a design cruise condition of M = 1.6 at 45,000 feet. The inlet design included an annular bypass duct that routed flow subsonically around an engine-mounted gearbox and diverted flow with high shock losses away from the fan tip. Two Reynolds-averaged Navier-Stokes codes were used for the analysis: an axisymmetric code called AVCS for the inlet and a 3-D code called SWIFT for the fan. The codes were coupled at a mixing plane boundary using a separate code for data exchange. The codes were used to determine the performance of the inlet/fan system at the design point and to predict the performance and operability of the system over the flight profile. At the design point the core inlet had a recovery of 96 percent, and the fan operated near its peak efficiency and pressure ratio. A large hub radial distortion generated in the inlet was not eliminated by the fan and could pose a challenge for subsequent booster stages. The system operated stably at all points along the flight profile. Reduced stall margin was seen at low altitude and Mach number where flow separated on the interior lips of the cowl and bypass ducts. The coupled analysis gave consistent solutions at all points on the flight profile that would be difficult or impossible to predict by analysis of isolated components.

Chima, Rodrick V.↗

A Comparison of Propeller and Centrifugal Fans for Circulating the Air in a Wind Tunnel

The tests described in this paper afford a direct comparison of the efficiency and smoothness of flow obtained with propeller fan and multiblade centrifugal fan drives in the same wind tunnel. The propeller fan was found to be superior to the centrifugal fan in that the efficiency was about twice as great, and the flow much smoother.

Weick, Fred E↗

Preliminary performance of a low loading high tip speed fan stage

Limited data indicates the feasibility of designing fan stages for operation with weak oblique shocks in the rotor blade tip region. A 1600 ft/sec rotor tip speed fan indicated an overall efficiency of 0.846 at a pressure ratio of 1.51 even though the rotor blades had incurred damage in the leading edge tip region prior to obtaining the design speed performance. After the test it was observed that a number of the rotor blade mid-span dampers had failed, subsequently damaging a number of rotor blades in the leading edge tip region.

Bailey, E. E.↗

Performance of two-stage fan with a first-stage rotor redesigned to account for the presence of a part-span damper

The NASA two-stage fan was tested with a redesigned first-stage rotor. The redesign included a new design approach to account for the presence of a part-span damper. At design speed the fan achieved a peak efficiency of 0.803, which is 1.9 percentage points higher than the original design. The peak efficiencies of the first stage and first rotor were 0.789 and 0.821, respectively. An improvement in efficiency of up to 5 percentage points in the damper region was achieved over the original large damper version. The stall margin, based on flow conditions at peak efficiency, was 10 percent at design speed.

Gorrell, W. T.↗

New Dynamic Spin Rig Capabilities Used to Determine Rotating Blade Dynamics

The Dynamic Spin Rig Facility at the NASA Glenn Research Center is used to determine the structural response of rotating engine components without the effects of aerodynamic loading. Recently, this rig's capabilities were enhanced through the replacement of grease-lubricated ball bearings with magnetic bearings. Magnetic bearings offer a number of advantages--the most important here being that they not only fully support the rotor system, but excite it as well. Three magnetic bearings support the rotor and provide five axes of controlled motion: an x- and y-axis translation at each of two radial bearings and a z-axis translation in the vertical or axial direction. Sinusoidal excitation (most commonly used) can be imparted on the rotor through the radial magnetic bearings in either a fixed or rotating frame of reference. This excitation is added directly to the magnetic bearing control output. Since the rotor is fully levitated, large translations and rotations of the rotor system can be achieved. Some of the capabilities of this excitation system were determined and reported. The accelerations obtained at the tip of a titanium flat plate test article versus the swept sine excitation sent to both radial bearings in phase and perpendicular to the plane containing the two blades are shown. Recent tests required the excitation of fundamental bending and torsional blade resonances at rotor speeds up to 10,000 rpm. Successful fixed synchronous rotation of the excitation signal provided the best detectable blade resonant vibrations at excitation frequencies up to 1100 Hz for the particular blades of interest. A noncontacting laser measurement system was used to collect blade-tip motions. From these data, the amplitude and frequency of the motion could be determined as well as the blade damping properties. Damping could be determined using two methods: (1) free decay and (2) curve fitting the vibration amplitude as a function of frequency in and around the resonance of interest and using the half-power method. The free decay of a composite blade vibrating at its first bending resonance while rotating at 3000 rp is shown. This new system is currently being used to support the Efficient Low-Noise Fan project at Glenn. The damping properties of prototype hollow composite blades specially designed to reduce fan noise are currently being determined.

Provenza, Andrew J.↗

Flight Deck Design of a Hybrid Turbine/Electric Aircraft

The SUbsonic Single Aft eNgine (SUSAN) program is being developed as a sustainable subsonic regional aircraft. NASA is conducting trade studies for this future hybrid single aisle passenger aircraft. The goal of reducing emission levels by 50% will be enabled through an advanced design. An aft mounted single turbine engine provides thrust and electric power to drive 16 wing mounted electric engines. Using the 16 counter-rotating electric fans will create an efficient, very high bypass ratio, engine. Electric engines allow for distributed thrust, reducing control surfaces and provide a greater dynamic response. Batteries provide boost for takeoff and climb, allowing a smaller, more efficient, turbine engine. As part of the SUSAN effort, two pilot-in-the-loop studies were conducted at NASA Langley Research Center in Virginia to explore flight deck design issues. In particular: how many throttles are required/desired for a 17-engine aircraft, does the hybrid electric design change the answer, what are the requirements for electric engine displays, what system pages are required, and what information is required to monitor the batteries. Objective and subjective data were collected after each scenario and at the end of the day with a guided set of questionnaires from sixteen crews paired by airline. Data along with pilot comments were used to improve the throttle and engine displays between the studies and used to make the final recommendations on flight deck configurations. This paper provides final design recommendations for the SUSAN flight deck and justification for each recommendation.

PAI↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Test of Single-Stage Axial-Flow Fan

A single-stage axial fan was built and tested in the shop of the propeller-research tunnel of the NACA. The fan comprised a simple 24-blade rotor having a diameter of 21 inches and a solidity of 0.86 and a set of 37 contravanes having a solidity of 1.33. The rotor was driven by a 25-horsepower motor capable of rotating at a speed of 3600 r.p.m. The fan was tested for volume, pressure, and efficiency over a range of delivery pressures and volumes for a wide range of contravane and blade-angle settings. The test results are presented in chart form in terms of nondimensional units in order that similar fans may be accurately designed with a minimum effort. The maximum efficiency (88 percent) was obtained by the fan at a blade angle of 30 degrees and a contravane angle of 70 degrees. An efficiency of 80 percent was obtained by the fan with the contravanes removed.

Bell, E Barton↗

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗