Search NASA⌕ Search

SEARCH · Search NASA

Results for “fiber optic cable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

102 records · Page 6

Development of a Radiation-Tolerant Front End Digitizer

High-radiation and high-temperature environments represent notoriously detrimental conditions for electronics. Yet sensors and instrumentation are critically important for the safe operation of nuclear reactors and for the validity of the scientific experiments conducted within them. Traditionally, sensors in such extreme environments operate with few active components, resulting in small signals (mV–V, nA–µA range) that must be transmitted through long cable runs before digitization by sensitive data acquisition systems located in clean, less-harsh environments. Long cables are prone to picking up noise through electromagnetic interference and distortion caused by their parasitic impedances, resulting in signal degradation. The Front End Digitizer (FREND) system described and demonstrated herein seeks to address these issues by enabling the placement of a radiation-resistant analog front end within reactor containment, or other high-radiation environments. FREND will enable early signal pre-amplification, digitization, and optical encoding within the high-radiation field to transmit sensor signals over an optical fiber to the non-nuclear environment of an instrument room. Early signal pre-amplification and digitization maintain signal integrity, whereas optical transmission renders the system blind to induced electromagnetic noise over the long cable runs. This report describes the FREND initial prototype, which can multiplex and optically encode data from up to four sensor inputs, though, in principle, this can be extended to any number of sensor inputs. The end result is an extremely flexible, high-fidelity system.

42 ENGINEERING↗

R$\&$D of Power Over Fiber in harsh environments and its novel application for the DUNE Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) is a next generation long-baseline neutrino experiment that will send an intense beam of neutrinos through two detector complexes: a near detector complex located at Fermilab (Chicago), and a far detector complex located $\sim$ 1.5 km underground at Sanford Underground Research Facility (SURF) in South Dakota. One of the DUNE Far Detector (FD) modules will employ the Vertical Drift (VD) Technology, which will vertically drift the ionized electrons from the cathode plane suspended at the mid-height of the active volume of the cryostat. The Photon Detection System (PDS) will be installed along the cathode and behind the field cage to increase the photon detection coverage. Due to the high voltage ($\sim$300 kV) present at the cathode, conventional copper cables cannot be used to power the photon detectors. Therefore, Power-over-Fiber (PoF) technology will be deployed to power the PDS based on optical power transmission over optical fibers. This poster presents the R$&$D campaign on different PoF components under harsh environments and its novel application in the DUNE PDS.

Martinez caicedo, David Alejandro [South Dakota Sc↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Performance of synthetic DAS as a function of array geometry

Distributed Acoustic Sensing (DAS) can record acoustic wavefields at high sampling rates and with dense spatial resolution difficult to achieve with seismometers. Using optical scattering induced by cable deformation, DAS can record strain fields with spatial resolution of a few meters. However, many experiments utilizing DAS have relied on unused, dark telecommunication fibers. As a result, the geophysical community has not fully explored DAS survey parameters to characterize the ideal array design. This limits our understanding of guiding principles in array design to deploy DAS effectively and efficiently in the field. A better quantitative understanding of DAS array behavior can improve the quality of the data recorded by guiding the DAS array design. Here we use steered response functions, which account for DAS fiber’s directional sensitivity, as well as beamforming and back-projection results from forward modelling calculations to assess the performance of varying DAS array geometries to record regional and local sources. A regular heptagon DAS array demonstrated improved capabilities for recording regional sources over other polygonal arrays, with potential improvements in recording and locating local sources. These results help reveal DAS array performance as a function of geometry and can guide future DAS deployments.

58 GEOSCIENCES↗

Transition to Online Cable Insulation Condition Monitoring

Nuclear power plant cables were originally qualified for 40 year life and generally have not required specific test verification to assure service availability through the initial plant qualification period. However, license renewals to 60 and 80 years of operation require a cable aging management program that depends on some form of test and verification to assure fitness for service. Environmental stress (temperature, radiation, chemicals, water, and mechanical) varies dramatically within a nuclear power plant and, in some cases, cables have degraded and required repair or replacement before their qualified end-of-life period. In other cases, cable conditions have been mild and dependable cable performance confirmed to extend well beyond the initial qualified life. Most offline performance-based testing requires cables to be de-coupled and de-energized for specially trained technicians to perform testing. These offline tests constitute an expensive operational burden that limits the economic viability of nuclear power plants. Although initial investment may be higher, new online test practices are emerging as options or complements to offline testing that avoid or minimize the regularly scheduled offline test burden. These online methods include electrical and fiber-optic partial discharge measurement, spread spectrum time or frequency domain reflectometry, distributed temperature profile measurements, and local interdigital capacitance measurement of insulation characteristics. Introduction of these methods must be supported by research to confirm efficacy plus either publicly financed or market driven investment to support the start-up expense of cost-effective instrumentation to monitor cable condition and assure reliable operation. This work summarizes various online cable assessment technologies plus introduces a new cable motor test bed to assess some of these technologies in a controlled test environment.

Glass, Samuel W.↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion sensor was also tested in soil at > 1 foot depth. Fe-coated OFS was loaded into a Draka cable, which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil (50/50).

corrosion↗

Fe Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. Effective monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of Fe-coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscatterring reflectometer (OBR), corrosion was monitored based on the increase in backscattered intensity amplitude of the light being passed as Fe undergoes corrosion. The Fe-coated OFSs were prepared with a film thickness between 25-225 nm by an electroless plating approach and corroded by a CO2-saturated acidic electrolyte. The corrosion rate was approximately 2.5 mm/yr for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based corrosion rates were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during corrosion of Fe was established. Corrosion was measurable out to > 100 m which is a significant improvement over our previous work showing corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at >1 ft depth. Fe-coated OFS was loaded into a Draka cable which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil.

aqueous environment↗

SYSM-562: DIM Fiber Connection Improvement Analysis

The National Ignition Facility is equipped with a wide suite of diagnostics including optical, x-ray, and neutron diagnostics to analyze experiments and look for areas of improvements. NIF diagnostics are either deployed to a fixed location on the target chamber or on a Diagnostic Instrument Manipulator (DIM). DIMs are two-stage telescoping devices used to insert, retract, position, and align a diagnostic instrument in the target chamber. Additionally, DIMs provide a standard set of cables to support operation of all DIM-based diagnostic instruments.

42 ENGINEERING↗

Scalable stable comb-to-tone integrated RF photonic drive for superconducting qubits

The recent advent of quantum computing has the potential to overhaul security, communications, and scientific modeling. Superconducting qubits are a leading platform that is advancing noise-tolerant intermediate-scale quantum processors. The implementation requires scaling to large numbers of superconducting qubits, circuit depths, and gate speeds, wherein high-purity RF signal generation and effective cabling transport are desirable. Fiber photonic-enhanced RF signal generation has demonstrated the principle of addressing both signal generation and transport requirements, supporting intermediate qubit numbers and robust packaging efforts; however, fiber-based approaches to RF signal distribution are often bounded by their phase instability. Here, we present a silicon photonic integrated circuit-based version of a photonic-enhanced RF signal generator that demonstrates the requisite stability, as well as a path towards the necessary signal fidelity.

47 OTHER INSTRUMENTATION↗

Mechanical Comparison of Short Models of Nb$_3$ Sn Low-$\beta$ Quadrupole for the Hi-Lumi LHC

MQXF is the Nb 3 Sn Low-β quadrupole magnet that the HL-LHC project is planning to install in the LHC interaction regions in 2026 to increase the LHC integrated luminosity. The magnet will be fabricated in two different lengths: 4.2 m for MQXFA, built in the US by the Accelerator Upgrade Project (AUP), and 7.15 m for MQXFB, fabricated by CERN. In order to qualify the magnet design and characterize its performance with different conductors, cable geometries and pre-load configurations, five short model magnets, called MQXFS, were fabricated, assembled and tested. We compare the mechanical behavior of short model magnets using experimental data and new numerical models that take into account the measured coil sizes as a function of position.

43 PARTICLE ACCELERATORS↗

Geophysical monitoring using active seismic techniques at the Citronelle Alabama CO 2 storage demonstration site

Between August 2012 and September 2014, about 114,000 metric tonnes of CO 2 was captured from the coal-fired Plant Barry Power Station at Bucks Alabama and injected into the Paluxy Formation above the oil pool in the southeast unit of the Citronelle Oilfield. Various monitoring methods were deployed at land surface and in project wells to measure system performance, comply with permit requirements and test new and innovative monitoring tools. The monitoring program relied heavily on active seismic methods for subsurface imaging of geologic structure and time-lapse seismic techniques to track the CO 2 migration in the injection interval. Both conventional geophone/hydrophone and fiber-optic based Distributed Acoustic Sensing (DAS) arrays were deployed and tested, allowing a side by side comparison of the equipment and techniques. Geophysical imaging of the subsurface was successful using DAS in the offset vertical seismic profile (OVSP) survey configuration. A high resolution OVSP image of the subsurface was obtained in 2014 with DAS, which exceeded project expectations in comparison to a lower resolution image obtained in 2012 using a conventional 80-level geophone array. A time-lapse image of the redistribution of CO 2 after injection ended in September 2014 was obtained with two DAS OVSP surveys from June 2014 and December 2015, thus successfully demonstrating its proof-of-concept. Unfortunately, a pre-injection baseline survey with DAS, which was in its initial stage of technology development in 2012, did not have sufficient quality for use, making it difficult to interpret the acquired DAS time-lapse difference. Additional research in this area has since demonstrated the utility of time-lapse DAS OVSP. DAS data were also acquired during a cross-well seismic survey conducted in 2014. Unfortunately, the DAS technique was not success in the cross-well survey configuration because the system noise level was too high in the crosswell frequency output range (100–1200 Hz) of the piezoelectric source (increasing by a factor of ten compared to VSP frequency band). Additionally, the cross-well geometry causes sub-horizontal (broadside) incidence on the vertical DAS fiber cable, which is known to be problematic. Current research is focused on improving the DAS cable response to broadside acoustic energy. Time-lapse seismic surveys using commercially available conventional arrays were also acquired. In contrast to the DAS acquired data, the cross-well seismic results obtained with the conventional array was highly successful and clearly showed the CO 2 remained in zone at the end of injection. Time-lapse differencing of the OSVP surveys acquired with the conventional arrays proved to be inconclusive. Finally, changes in wellbore conditions between surveys and unavoidable changes in equipment (the array used for the baseline survey was retired) affected data quality, making it difficult to interpret the OVSP results.

58 GEOSCIENCES↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗