Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

THREE-DIMENSIONAL RECONSTRUCTION OF THE DENSITY FIELD: AN SVD APPROACH TO WEAK-LENSING TOMOGRAPHY

We present a new method for constructing three-dimensional mass maps from gravitational lensing shear data. We solve the lensing inversion problem using truncation of singular values (within the context of generalized least-squares estimation) without a priori assumptions about the statistical nature of the signal. This singular value framework allows a quantitative comparison between different filtering methods: we evaluate our method beside the previously explored Wiener-filter approaches. Our method yields near-optimal angular resolution of the lensing reconstruction and allows cluster sized halos to be de-blended robustly. It allows for mass reconstructions which are two to three orders of magnitude faster than the Wiener-filter approach; in particular, we estimate that an all-sky reconstruction with arcminute resolution could be performed on a timescale of hours. We find however that linear, non-parametric reconstructions have a fundamental limitation in the resolution achieved in the redshift direction.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification evaluation methods

Methods for airplane parameter estimation, the equation error method, output error method, and two advanced methods are presented and their basic properties described. The advanced methods include the maximum likelihood and extended Kalman filter method. For a better understanding of the estimation techniques a first-order scalar differential equation is used as a model of the system under test. Application of the methods to a general multivariable linear system is briefly outlined. A note on the parameter estimation in the frequency domain is also presented. Numerical examples along with the comparison of results from various methods are given.

Klein, V.↗

Dynamic data filtering system and method

A computer-implemented dynamic data filtering system and method for selectively choosing operating data of a monitored asset that modifies or expands a learned scope of an empirical model of normal operation of the monitored asset while simultaneously rejecting operating data of the monitored asset that is indicative of excessive degradation or impending failure of the monitored asset, and utilizing the selectively chosen data for adaptively recalibrating the empirical model to more accurately monitor asset aging changes or operating condition changes of the monitored asset.

97 MATHEMATICS AND COMPUTING↗

Electronic filters, hearing aids and methods

An electronic filter for an electroacoustic system. The system has a microphone for generating an electrical output from external sounds and an electrically driven transducer for emitting sound. Some of the sound emitted by the transducer returns to the microphone means to add a feedback contribution to its electical output. The electronic filter includes a first circuit for electronic processing of the electrical output of the microphone to produce a filtered signal. An adaptive filter, interconnected with the first circuit, performs electronic processing of the filtered signal to produce an adaptive output to the first circuit to substantially offset the feedback contribution in the electrical output of the microphone, and the adaptive filter includes means for adapting only in response to polarities of signals supplied to and from the first circuit. Other electronic filters for hearing aids, public address systems and other electroacoustic systems, as well as such systems, and methods of operating them are also disclosed.

Engebretson, A. Maynard↗

Electronic filters, hearing aids and methods

An electronic filter for an electroacoustic system. The system has a microphone for generating an electrical output from external sounds and an electrically driven transducer for emitting sound. Some of the sound emitted by the transducer returns to the microphone means to add a feedback contribution to its electrical output. The electronic filter includes a first circuit for electronic processing of the electrical output of the microphone to produce a first signal. An adaptive filter, interconnected with the first circuit, performs electronic processing of the first signal to produce an adaptive output to the first circuit to substantially offset the feedback contribution in the electrical output of the microphone, and the adaptive filter includes means for adapting only in response to polarities of signals supplied to and from the first circuit. Other electronic filters for hearing aids, public address systems and other electroacoustic systems, as well as such systems and methods of operating them are also disclosed.

Engebretson, A. Maynard↗

Method of fabricating a scalable nanoporous membrane filter

A method of fabricating a nanoporous membrane filter having a uniform array of nanopores etch-formed in a thin film structure (e.g. (100)-oriented single crystal silicon) having a predetermined thickness, by (a) using interferometric lithography to create an etch pattern comprising a plurality array of unit patterns having a predetermined width/diameter, (b) using the etch pattern to etch frustum-shaped cavities or pits in the thin film structure such that the dimension of the frustum floors of the cavities are substantially equal to a desired pore size based on the predetermined thickness of the thin film structure and the predetermined width/diameter of the unit patterns, and (c) removing the frustum floors at a boundary plane of the thin film structure to expose, open, and thereby create the nanopores substantially having the desired pore size.

36 MATERIALS SCIENCE↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Gapped-filtering for efficient Chebyshev expansion of the density projection operator

In this paper, we develop the gapped-filtering method, whereby a short Chebyshev expansion accurately represents the density-matrix operator. The method optimizes the Chebyshev coefficients to give the correct density matrix at all energies except within the gapped region where there are no eigenstates. Gapped filtering reduces the number of required terms in the Chebyshev expansion compared to traditional expansion methods, as long as one knows or can determine efficiently the HOMO and LUMO positions. The reduction is especially noticeable (factors of 2-3) when high accuracy is sought. To exemplify the method, we use gapped-filtering to increase the efficiency of stochastic-GW calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correcting for digital image correlation speckle inversion at high temperature using color cameras

Digital image correlation (DIC) is a popular, noncontacting technique to measure full-field deformation by using cameras to track the motion of an applied surface pattern. Because it is noncontacting, DIC can be performed for extreme temperature applications (e.g., hot-fire rocket testing of carbon composite rocket nozzles) under harsh conditions during which bonded gauges are damaged. Speckle pattern inversion is a phenomenon that sometimes occurs while performing high-temperature DIC. During speckle pattern inversion, portions of the surface pattern that were initially darker at room temperature (e.g., graphite) may emit more light due to blackbody radiation than the portions that were initially paler, thereby producing images in which the pattern appears inverted at high temperature relative to the initial pattern at room temperature. This phenomenon can prevent the correlation algorithm from being able to resolve the displacements between images. This work compares three methods to mitigate speckle pattern inversion: (A) the subtraction method, a recently-published technique in which two high-temperature images are subtracted to remove unwanted light; (B) the filtering method, a popular technique in which optical bandpass filters screen out unwanted light; and (C) the histogram rescaling method, a proposed new method that pairs a color camera with a blue light source and uses information from the green sensor of the camera to correct against inversion in the blue sensor through postprocessing. The histogram rescaling method is shown to successfully eliminate speckle pattern inversion and has the added advantages that it does not require quasi-static loading to be able to compensate for speckle pattern inversion, nor does it impose thick-glass distortions caused by the optical filter.

Rowley, Lindsey J.↗

Characteristics of the RF Negative Ion Source Using a Mesh Grid Bias Method

Using a mesh grid bias method for plasma parameter control, volume production of hydrogen negative ions H{sup -} is studied in pure hydrogen rf plasmas. Relationship between the extracted H{sup -} ion currents and plasma parameters is discussed. Both high and low electron temperature T{sub e} plasmas are produced in the separated regions when the grid is negatively biased. In addition, with changing grid potential V{sub g}, values of n{sub e} increase while T{sub e} decrease in their values. The negative ion production depends strongly on the grid potential and related plasma conditions. It is also confirmed that grid bias method is more effective than the so-called magnetic filter method to optimize plasma parameters for H{sup -} production. Production of deuterium negative ions D{sup -} is also studied briefly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method and apparatus for filtering visual documents

A method and apparatus for producing an abstract or condensed version of a visual document is presented. The frames comprising the visual document are first sampled to reduce the number of frames required for processing. The frames are then subjected to a structural decomposition process that reduces all information in each frame to a set of values. These values are in turn normalized and further combined to produce only one information content value per frame. The information content values of these frames are then compared to a selected distribution cutoff point. This effectively selects those values at the tails of a normal distribution, thus filtering key frames from their surrounding frames. The value for each frame is then compared with the value from the previous frame, and the respective frame is finally stored only if the values are significantly different. The method filters or compresses a visual document with a reduction in digital storage on the ratio of up to 700 to 1 or more, depending on the content of the visual document being filtered.

Rorvig, Mark E.↗

Large eddy simulation of a coaxial jet with a synthetic turbulent inlet

This study analyzed the effects of two methods of synthetic inlet turbulence on the accuracy of coaxial, circular jet simulations with regards to experimental data. The two methods that were utilized in the study were a digital filter method and a synthetic eddy method. This study examines the implementation of these methods into an academic LES code, with extensive evaluation of the simulation data compared to experimental results. The results in the paper are presented for two different mesh resolutions, 22 and 8 million cells. The simulations were performed for three different velocity ratios of the annular to the inner jet: 0.0, 1.0 and 1.5. The inlet methods were utilized in two ways, one by setting the velocity fluctuation profile based on experimental data of the inlet flow, the second by setting an estimated isotropic-fluctuation profile. In this way, using the estimated method can be compared to using the prescribed fluctuations, which may not be usable if experimental data of the inlet is not available. When comparing the centerline profiles to the velocity data for the turbulent inlet, the data for velocity ratios 1.0 and 1.5 were improved compared to the experimental profiles. However, for the velocity ratio 0.0 case velocity data when using the turbulent inlet the data showed significant decay and did not match experimental profiles in the far field of the jet. The radial data for a velocity ratio of 0.0 showed better agreement with the experimental data in the jet spreading to develop the proper velocity profile. The velocity fluctuation data was the most accurate in the near field region when the turbulent inlet was used. A comparison can also be made between using a prescribed fluctuation inlet and just using the approximated inlet condition. In the near field region using the prescribed fluctuations from data is better, as is expected. However, in some cases the approximation can perform just as well in the fluctuation profile in the far field region. For velocity ratios of 0.0 and 1.0, simply using an approximation for the inlet with isotropic fluctuations performed almost as well as the prescribed fluctuation method in the far-field region. Lastly, at a velocity ratio of 1.5 this improvement was not present, possibly due to the higher Reynolds number in the annular region.

01 COAL, LIGNITE, AND PEAT↗

Speeding up Particle Track Reconstruction in the CMS Detector using a Vectorized and Parallelized Kalman Filter Algorithm

Building particle tracks is the most computationally intense step of event reconstruction at the LHC. With the increased instantaneous luminosity and associated increase in pileup expected from the High-Luminosity LHC, the computational challenge of track finding and fitting requires novel solutions. The current track reconstruction algorithms used at the LHC are based on Kalman filter methods that achieve good physics performance. By adapting the Kalman filter techniques for use on many-core SIMD architectures such as the Intel Xeon and Intel Xeon Phi and (to a limited degree) NVIDIA GPUs, we are able to obtain significant speedups and comparable physics performance. New optimizations, including a dedicated post-processing step to remove duplicate tracks, have improved the algorithm's performance even further. Here we report on the current structure and performance of the code and future plans for the algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring eye movements during locomotion: filtering techniques for obtaining velocity signals from a video-based eye monitor

Video-based eye-tracking systems are especially suited to studying eye movements during naturally occurring activities such as locomotion, but eye velocity records suffer from broad band noise that is not amenable to conventional filtering methods. We evaluated the effectiveness of combined median and moving-average filters by comparing prefiltered and postfiltered records made synchronously with a video eye-tracker and the magnetic search coil technique, which is relatively noise free. Root-mean-square noise was reduced by half, without distorting the eye velocity signal. To illustrate the practical use of this technique, we studied normal subjects and patients with deficient labyrinthine function and compared their ability to hold gaze on a visual target that moved with their heads (cancellation of the vestibulo-ocular reflex). Patients and normal subjects performed similarly during active head rotation but, during locomotion, patients held their eyes more steadily on the visual target than did subjects.

NASA Discipline Neuroscience↗

Detecting Low-level Radiation Sources Using Border Monitoring Gamma Sensors

We consider a problem of detecting a low-level radiation source using a network of Gamma spectral sensors placed on the periphery of a monitored region. We propose a computationally light-weight, correlation-based method which is primarily intended for systems with limited computing capacity. Sensor measurements are combined at the fusion by first generating decisions at each time step and then taking their majority vote within a time widow. At each time step, decisions are generated using two strategies: (i) SUM method based on a threshold decision on a correlation statistic derived from measurements from all sensors, and (ii) OR method based on logical-OR of threshold decisions based on correlations statistics of individual sensor measurements. We derive analytical performance bounds for false alarm rates of SUM and OR methods, and show that their performance is enhanced by the temporal smoothing of majority vote within a time window. Using measurements from a test campaign, we generate a border monitoring scenario with twelve 2"x2" NaI Gamma sensors deployed on the periphery of 42m x 42m outdoor region. A Cs-137 source is moved in a straight-line across this region, starting several meters outside and finally moving away from it. We illustrate the performance of both correlation-based detection methods, and compare their performances with each other and with a particle filter method. Overall, under small false-alarm conditions, the OR fusion is found to produce better detection performance.

Sen, Satyabrata↗

SU-E-I-33: Initial Evaluation of Model-Based Iterative CT Reconstruction Using Standard Image Quality Phantoms

Purpose: The purpose of this study was to compare a new model-based iterative reconstruction with existing reconstruction methods (filtered backprojection and basic iterative reconstruction) using quantitative analysis of standard image quality phantom images. Methods: An ACR accreditation phantom (Gammex 464) and a CATPHAN600 phantom were scanned using 3 routine clinical acquisition protocols (adult axial brain, adult abdomen, and pediatric abdomen) on a Philips iCT system. Each scan was acquired using default conditions and 75%, 50% and 25% dose levels. Images were reconstructed using standard filtered backprojection (FBP), conventional iterative reconstruction (iDose4) and a prototype model-based iterative reconstruction (IMR). Phantom measurements included CT number accuracy, contrast to noise ratio (CNR), modulation transfer function (MTF), low contrast detectability (LCD), and noise power spectrum (NPS). Results: The choice of reconstruction method had no effect on CT number accuracy, or MTF (p<0.01). The CNR of a 6 HU contrast target was improved by 1–67% with iDose4 relative to FBP, while IMR improved CNR by 145–367% across all protocols and dose levels. Within each scan protocol, the CNR improvement from IMR vs FBP showed a general trend of greater improvement at lower dose levels. NPS magnitude was greatest for FBP and lowest for IMR. The NPS of the IMR reconstruction showed a pronounced decrease with increasing spatial frequency, consistent with the unusual noise texture seen in IMR images. Conclusion: Iterative Model Reconstruction reduces noise and improves contrast-to-noise ratio without sacrificing spatial resolution in CT phantom images. This offers the possibility of radiation dose reduction and improved low contrast detectability compared with filtered backprojection or conventional iterative reconstruction.

60 APPLIED LIFE SCIENCES↗

A Deep Learning Filter for the Intraseasonal Variability of the Tropics

Abstract This paper presents a novel application of convolutional neural network (CNN) models for filtering the intraseasonal variability of the tropical atmosphere. In this deep learning filter, two convolutional layers are applied sequentially in a supervised machine learning framework to extract the intraseasonal signal from the total daily anomalies. The CNN-based filter can be tailored for each field similarly to fast Fourier transform filtering methods. When applied to two different fields (zonal wind stress and outgoing longwave radiation), the index of agreement between the filtered signal obtained using the CNN-based filter and a conventional weight-based filter is between 95% and 99%. The advantage of the CNN-based filter over the conventional filters is its applicability to time series with the length comparable to the period of the signal being extracted. Significance Statement This study proposes a new method for discovering hidden connections in data representative of tropical atmosphere variability. The method makes use of an artificial intelligence (AI) algorithm that combines a mathematical operation known as convolution with a mathematical model built to reflect the behavior of the human brain known as artificial neural network. Our results show that the filtered data produced by the AI-based method are consistent with the results obtained using conventional mathematical algorithms. The advantage of the AI-based method is that it can be applied to cases for which the conventional methods have limitations, such as forecast (hindcast) data or real-time monitoring of tropical variability in the 20–100-day range.

Stan, Cristiana↗