Search NASA⌕ Search

SEARCH · Search NASA

Results for “fire modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

California annual grass phenology and allometry influence ecosystem dynamics and fire regime in a vegetation demography model

Grass-dominated ecosystems cover wide areas of the land surface yet have received far less attention from the Earth System Model (ESM) community. This limits model projections of ecosystem dynamics in response to global change and coupled vegetation–climate dynamics. We used the Functionally Assembled Terrestrial Ecosystem Simulator (FATES), a dynamic vegetation demography model, to determine ecosystem sensitivity to alternate, observed grass allometries and biophysical traits, and evaluated model performance in capturing California C 3 annual grasslands structure and fire regimes. Grass allometry, leaf physiology, plant phenology, and plant mortality all drove the seasonal variation in matter and energy exchange and fire dynamics in California annual grasslands. Allometry influenced grassland structure and function mainly through canopy architecture-mediated space and light competition instead of through carbon partitioning strategy. Regional variation in grassland annual burned area was driven by variation in ecosystem productivity. Our study advances the modeling of grassy ecosystems in ESMs by establishing the importance of grass allometry and plant phenology and mortality in driving C 3 annual grassland seasonal dynamics and fire regime. The calibrated annual grass allometry and biophysical traits presented can be applied in future studies to project climate–vegetation–fire feedbacks in annual grass-dominant ecosystems under global change.

54 ENVIRONMENTAL SCIENCES↗

TES: Modelling Microbes to Predict Post-Fire Carbon Cycling in the Boreal Forest across Burn Severities (Exploratory Proposal)

Wildfires in boreal ecosystems represent a globally significant ecological process that is expected to be sensitive to changing climate as well as forest management strategies, but is currently insufficiently understood and represented in models. We sought to determine whether linking belowground microbial community composition, size, and activity to aboveground properties of burn severity and plant community composition (upland jack pine and upland spruce) would allow us to better model post-fire soil CO 2 fluxes using the Carbon, Organisms, Rhizosphere and Protection in the Soil Environment (CORPSE) model. We used an integrated modelling experimental approach, with mechanistic laboratory experiments designed to inform models.

54 ENVIRONMENTAL SCIENCES↗

Model Data Archive Associated with Manuscript "Fire-altered Carbon Pools Create Disturbance Memory in Stream Dissolved Organic Carbon"

This data package supports the publication “Fire-altered Carbon Pools Create Disturbance Memory in Stream Dissolved Organic Carbon” by Li et al. (2026). The package contains processed model inputs, configuration files, restart files, simulation outputs, scripts, and visualization products used to evaluate post-fire dissolved organic carbon (DOC) dynamics in the Naches River Watershed, Washington, USA, following the 2021 Schneider Springs Fire. The modeling workflow couples ELM-BGC, the biogeochemistry-enabled Energy Exascale Earth System Model Land Model; ATS, the Advanced Terrestrial Simulator for integrated surface-subsurface hydrology; and PFLOTRAN, a reactive transport model for multicomponent aqueous geochemistry. Together, these models simulate how wildfire-induced changes in vegetation, litter, coarse woody debris, and soil organic matter influence DOC production, transport, and reaction from burned hillslopes to stream networks. The archive includes preprocessed meteorological, geospatial, hydrologic, and biogeochemical forcing data; ELM-BGC-derived DOC source terms; ATS mesh files; PFLOTRAN reactive-transport inputs; model configuration files; spin-up and transient restart files; watershed-scale diagnostic outputs; stream concentration time series; and figures or visualization files used to inspect and reproduce key results. File types include Hierarchical Data Format 5 (HDF5) files for gridded forcing and model-coupling data, model input and configuration files for ELM-BGC, ATS, and PFLOTRAN, restart and simulation-output files generated by the modeling workflow, tabular or time-series diagnostic outputs, scripts for post-processing and figure generation, and image or visualization products associated with the manuscript. Use of the package depends on the intended task. Re-running the simulations requires the relevant modeling software, including ELM-BGC, ATS, and PFLOTRAN as ATS's geochemical engine. Inspecting outputs and reproducing figures requires Python with scientific plotting libraries such as Matplotlib, and three-dimensional model outputs may be viewed with ParaView. Geographic information system files or maps may be inspected with ArcGIS Pro or comparable GIS software. The data package is intended to enable traceability, reuse, and partial reproduction of the coupled land-to-watershed hydro-biogeochemical modeling workflow used to test how wildfire disturbance affects terrestrial carbon pools and downstream DOC dynamics.

ATS↗

Dynamic Simulation of a Sub-Critical Coal Fired Power Plant

In order to address the demanding operating conditions for remaining coal-fired power plants, a dynamic model and a suite of tools have been developed for studying load cycling and to find optimization opportunities. A sub-critical steam cycle power plant was modeled in a flow-sheet modeling tool, APROS™. The model represented the firing system, economizer, evaporator, superheat, and reheat systems. Four loads from 100% TMCR to 25% TMCR were calibrated and tested such that low-to-high cycling could be studied. The model was run through various load cycles; one of which is presented here. This modeling is a prototype for general use in developing cutting edge controls products and for maximizing economic, low-emissions, and efficient operation of the existing coal power fleet.

Braun, Timothy↗

Evaluating FRI3D for Cost Savings in Fire Hazard Analysis at DOE Sites

A fire hazard analysis, required for many U.S. Department of Energy (DOE) facilities, is a complex, cumbersome, and costly process. Fire hazard analyses may be viewed as a checkbox, but ideally and in spirit with the DOE-STD-1066, the fire hazard analysis (FHA) should be a part of the workflow and used to help in modifications, maintenance, and improving operational safety. With current FHA development processes, it is both time and cost prohibitive for true integration. A tool called Fire Risk Investigation in 3D or FRI3D was developed under the DOE Light Water Reactor Sustainability program to simplify and automate many aspects of a fire probabilistic risk analysis for existing nuclear power plants. The FRI3D tool automates fire scenarios by combining approved fire simulation codes, U.S. Nuclear Regulatory Commission fire calculations methods, 3D modeling and visualization, and probabilistic risk analysis models into a single workflow supported with a user interface. FRI3D was initially designed for used in combination with a PRA, this case study, evaluated using FRI3D for a plant modification, determined the benefits that detailed fire modeling can have for U.S. Department of Energy facilities with or without a PRA model. It also looked at what tasks from DOE requirements could be reduced using the tool and what is needed to integrate fire hazard analysis into site workflow.

97 - MATHEMATICS AND COMPUTING↗

The impact of plant‐derived fire management prescriptions on fire‐responsive bird species

Abstract In fire‐prone regions, the occurrence of some faunal species is contingent on the presence of resources that arise through post‐fire plant succession. Through planned burning, managers can alter resource availability and aim to provide the conditions required to promote biodiversity. Understanding how species occurrence changes at different spatial and temporal scales after fire is essential to achieve this goal. However, many fire prescriptions are guided primarily by the responses of fire‐sensitive plants when setting tolerable fire intervals. This approach assumes that maintaining floristic diversity will satisfy the requirements of fauna. We surveyed bird species in two semi‐arid vegetation types across an environmental gradient in south‐eastern Australia. We conducted four surveys at each of 253 sites across a 75‐year chronosequence of time since fire and used generalized additive mixed models to examine changes in the occurrence of birds in response to time since fire. Model predictions were compared to plant‐derived fire prescriptions currently guiding fire management in the region. Time since fire was a significant predictor for 18 of 28 species modeled, in at least one vegetation type, over a gradient of 1.3° of latitude. We detected considerable variation in the responses of some species, both between vegetation types and geographically within a vegetation type. Our evaluation of plant‐derived fire prescriptions suggests that the intervals considered acceptable for maintaining floristic diversity may not be sustainable for populations of birds requiring longer unburnt vegetation, with 6 of the 12 species assessed attaining a mean occurrence probability of 20.3% by the minimum tolerable fire interval, and 57.3% by the maximum tolerable fire interval, in their respective vegetation types. Our findings highlight the potential vulnerability of fire‐responsive bird species if fire prescriptions are applied in a manner that fails to account for the slow development of habitat resources needed by some species, and the variation detected within the responses of species. This highlights the need for species‐specific data collected at an appropriate spatial scale to inform management plans.

Makdissi, Rhys↗

Analysis of historic fires to determine most frequent challenging events

The fire probabilistic risk assessment framework for nuclear power plants relies on experimental data to determine expected fire behavior or to validate models to predict fire conditions in the plant. To support reducing the uncertainty in this experimental data, a research effort was conducted to identify the most frequent and challenging fire scenarios using historic fire data from nuclear power plants in the United States. To support this effort, an electronic version of the publicly available Updated Fire Event Database developed by Electric Power Research Institute was produced resulting in data on 2111 fire events, 540 events were labelled as being challenging fires with 74.2% of these challenging fire events being due to eleven selected fire types. In conclusion, of these fire types, electrical and electronic equipment, transient combustibles, and liquid fires were the most frequent of the challenging fires. The fire scenario specifics were characterized for each of the eleven selected types and then related to existing fire experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data accompanying the publication "Sensitivity of grass fires burning in marginal conditions to atmospheric turbulence" in the Journal of Geophysical Research-Atmospheres

Data accompanying Jonko, Yedinak, Conley, and Linn (2021): "Sensitivity of grass fires burning in marginal conditions to atmospheric turbulence", JGR-Atmospheres. LA-UR-21-24832. The following files were generated from simulations performed with Los Alamos National Laboratory coupled atmosphere-fire behavior model FIRETEC v1.3: -area_burned.csv contains the area burned per second in m^2 for 45 CORE simulations, 20 INIT simulations and 20 BOUND simulations (85 columns), and 600 seconds of simulation (600 rows). -fire_perimeter.csv containing the fire perimeters in m for 45 CORE simulations, 20 INIT simulations and 20 BOUND simulations (85 columns), and 600 seconds of simulation (600 rows). -consumption_per_second.csv containing consumption in kg/s for 45 CORE simulations, 20 INIT simulations and 20 BOUND simulations (85 columns), and 600 seconds of simulation (600 rows). -rate_of_spread.csv containing the distance of the fire front from the ignition line in m for 45 CORE simulations, 20 INIT simulations and 20 BOUND simulations (85 columns), and 600 seconds of simulation (600 rows). -CORE1_u_10m_300_sec.hdf, INIT3_u_10m_300_sec.hdf, and BOUND3_u_10m_300_sec.hdf contain u wind speeds at 10 m height for 300 seconds (3D: time, x, y) of simulation for simulations CORE1, INIT3, and BOUND3, respectively. -CORE.final.fuel.density.hdf contains final fuel densities in the surface layer of the model (3D: ensemble member, x, y) for all 45 CORE simulations. -CORE{1-45}_3D_u_120_sec.hdf: 45 files containing vertically and horizontally resolved u winds for 120 seconds of simulation (4D: time, x, y, z) for the 45 CORE ensemble members. For additional information about this data, please contact the corresponding author at ajonko@lanl.gov.

54 ENVIRONMENTAL SCIENCES↗

Airborne LiDAR to Improve Canopy Fuels Mapping for Wildfire Modeling

Increasing conflict between wildfire and the built environment has increased the need for more up-to-date and finer resolution canopy fuels data to improve wildfire modeling and associated risk forecasts. The US Forest Service and US Department of the Interior’s LANDFIRE product, which provides 30-m resolution canopy fuels data for the entire US, is one of the most widely used sources of fuels data. However, the last complete mapping effort for LANDFIRE is based on 2016 conditions, and subsequent updates reflect disturbances 1-2 years behind the release year. Airborne systems equipped with Light Detection and Ranging (LiDAR) sensors can be deployed to actively sense canopy structure and estimate canopy fuels data (cover, height, base height, bulk density) at finer resolutions. Canopy base height (CBH) and canopy bulk density (CBD) are difficult to measure both in the field and in LiDAR point clouds. Still, they are important for accurately modeling crown fires, which are often intense and difficult to contain. Additionally, point cloud datasets are large, and calculations require efficient utilization of computational resources. To address these challenges, we are working on an approach that uses openly available National Ecological Observatory Network (NEON) airborne LiDAR data, with calculations processed in the R programming language and parallelized through the lidR package. CBH and CBD are often derived from tree height, diameter at breast height, and species-specific allometries using the Fire and Fuels Extension of the Forest Vegetation Simulator (FFE-FVS). We aim to test if airborne LiDAR can estimate CBH and CBD without the use of empirical equations. Reliable estimates of canopy fuels data directly from airborne LiDAR could streamline quick, fine-resolution updates for use in wildfire behavior models.

54 ENVIRONMENTAL SCIENCES↗

Report on High-Fidelity Dynamic Modeling of a Coal-Fired Steam Power Plant

As a result of the growth of renewables including solar and wind energy with fluctuating production, fossil fuel power plants are being required to cycle between high and low power production. This cycling is both at a greater frequency and over a wider range than in the past. In many cases, power plants are not designed for this type of cycling operation but can nonetheless endure these challenging operation requirements under the right conditions. In this project, optimal solution for enhanced flexible operations are being investigated using model based estimation and control techniques. To support the development of model-based estimator and model-based controls at GE Global Research, GE Steam Power configured a dynamic model using a reference steam plant design including the boiler, turbine, and water/steam conditioning systems as well as the controls needed for plant cycling with stability and reliability. The dynamic model was built using the APROS® software from VTT, and then calibrated to multiple load conditions from full load (100%TMCR) to partial loads (75%TMCR, 50%TMCR and 25%TMCR) based on internally developed steady state heat balance models at the unit level. These internal heat balance models are based on first principles and extensive engineering experiences from GE Steam Power as an OEM and a services provider. This topical report presents the structure of the unit level dynamic model, the tuning process, and representative simulation results from typical load cycling simulations using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Dynamic Modeling and Simulation of a Subcritical Coal-Fired Power Plant under Load-Following Conditions

Dynamic models for power plants that capture realistic general process trends and effects of manipulated variables are needed to improve load-following, while minimizing carbon footprint. In this work, a dynamic modeling approach and simulation results for subcritical coal-fired power plant components are presented. These encompass simulation of the dynamics in the fireside, including the effects of fuel, air combustion, and the dynamics of the entire waterside and power generation sections. This model development enables the simulation and analysis of the important short and long-time scale dynamics of components such as heaters, evaporative loop, and power generation units. Furthermore, additional variables in the power generation section are introduced to improve model accuracy, extending the prediction capability of subcritical power plant models and opening new opportunities for research in operator training, optimization, and advanced model-based controller design that are based on these models. The change in process gain for different ramp rates associated with disturbance signals that affect process variables is also explored and a correlation developed. This provides opportunities to study disturbance rejection control implementation and adaptation for scenarios with such variations in ramp rates. The prediction capabilities of selected components are compared to data available in literature, with the obtained root mean squared error ranges that reflect the model performance and quality of predictions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effect of terrain-influenced winds on fire spread in QUIC-Fire

Here in this manuscript, we describe the implementation of the terrain-following version of QUIC-URB into QUIC-Fire and a demonstration of the impacts of terrain-influenced winds on QUIC-Fire-simulated fire spread. No changes to the underlying QUIC-Fire fire spread algorithm were made other than what was required to correctly account for the inclusion of terrain. This paper summarizes simulations used to understand how the QUIC-URB terrain-influenced winds affect upslope fire behavior without additional changes to the QUIC-Fire fire spread algorithm. Previously published FIRETEC results are compared to simulation results from the modified QUIC-Fire (incorporating terrain-influenced winds) that use the same topographies and fuels. QUIC-Fire results showed overall similar behaviors in terms of how the topographies affected fire shapes and trends in spread rates. Due to the terrain-following version of QUIC-URB being unable to generate flow separations at the crest of hills, fire spread rates in these regions across all non-flat topographies were over-predicted when compared to FIRETEC. Lateral fire growth showed similar trends with FIRETEC between topographies but did not capture the increase in spread due to a diagonal interface between grassland and forested fuel regions in the test domain. These simulations suggest possible refinements that are necessary to improve QUIC-Fire and thus guide ongoing efforts related to: how flame tilt angle is accounted for, the incorporation of non-local drag effects, and the inclusion of the wake-eddy parameterizations that are used in QUIC-URB.

54 ENVIRONMENTAL SCIENCES↗

Harnessing the Second-Order Metal−Insulator Transition for Neuromorphic Computing

Vanadium oxides are widely studied phase change materials for brain-inspired computing architectures. Systems like VO 2 and V 2 O 3 exhibit first-order metal−insulator transitions (MITs) with hysteresis and percolative switching, increasing stochasticity and device variability. Here, we focus on the less explored Magnéli phase V 4 O 7 , which undergoes a continuous, non-hysteretic, second-order MIT. This surprisingly enables highly reproducible volatile resistive switching in spiking-neuron-type devices. We synthesize V 4 O 7 films, characterize their structural and transport properties, and demonstrate voltage and current-driven threshold switching with electrothermal feedback. In a Pearson–Anson oscillator, V 4 O 7 devices produce stable, tunable spiking across 20–200 kHz, with consistent operation among multiple devices. We introduce a numerical analog leaky-integrate-and-fire (aLIF) model that captures waveform shapes and their dependence on load resistance, temperature, and voltage. Furthermore, these findings suggest that second-order MIT materials like V 4 O 7 are promising for deterministic, scalable spiking neuron arrays for neuromorphic computing.

V4O7↗

Identifying Characteristics of Wildfire Towers and Troughs

Wildfire behavior is dictated by the complex interaction of numerous physical phenomena including dynamic ambient and fire-induced winds, heat transfer, aerodynamic drag on the wind by the fuel and combustion. These phenomena create complex feedback effects between the fire and its surroundings. In this study, we aim to study the mechanisms by which buoyant flame dynamics along with vortical motions and instabilities control wildfire propagation. Specifically, this study employs a suite of simulations conducted with the physics-based coupled fire-atmosphere behavior model (FIRETEC). The simulations are initialized with a fire line and the fires are allowed to propagate on a grass bed, where the fuel heights and wind conditions are varied systematically. Flow variables are extracted to identify the characteristics of the alternating counter-rotational vortices, called towers and troughs, that drive convective heat transfer and fire spread. These vortices have previously been observed in wildfires and laboratory fires, and have also been observed to arise spontaneously in FIRETEC due to the fundamental physics incorporated in the model. However, these past observations have been qualitative in nature and no quantitative studies can be found in the literature which connected these coherent structures fundamental to fire behavior with the constitutive flow variables. To that end, a variety of state variables are examined in the context of these coherent structures under various wind profile and grass height conditions. Identification of various correlated signatures and fire-atmosphere feedbacks in simulations provides a hypothesis that can be tested in future observational or experimental efforts, potentially assisting experimental design, and can aid in the interpretation of data from in situ detectors.

54 ENVIRONMENTAL SCIENCES↗

Full Scale 3D Computational Model of the Industrial -Scale Coal Fired Boiler Performance for Temperature Sensor Installation Guidance

Abstract Nearly 30% of the electricity is generated by using coal as the primary fuel in the US. One of the major concerns in coal-fired power plants is the failure of boiler tubes that leads to unscheduled maintenance and has a huge economical and societal impact. High temperature flue gas along with ash pass over the boiler tubes, which over time leads to tube failure. Therefore, developing temperature sensors for harsh environments and install them for temperature sensing and boiler tube lifetime prediction is an urgent need. On the side of sensor development, the location of the sensor installation is important for stable sensing performance and easy calibration. In this study, computational fluid dynamics and heat transfer modeling are adopted to establish a full-scale 3-dimensional model of a coal-fired boiler to investigate the flue gas temperature distribution within the boiler and identify the proper locations for sensor installation. We proposed three criteria to select the temperature sensor installation location: (1) select the boiler tube panel away from the sidewalls, (2) select the boiler tube section closer to the top wall of the boiler; and (3) select the boiler tube on the back of the boiler panel (not directly facing the flue gas flow). In these regions, the flue gas temperature is stable, providing an ideal environment for stable temperature sensing and calibration.

Gupta, Tanuj↗