Development of a laser doppler flowmeter for gas velocity measurement
Continuous wave gas laser Doppler flow meter for gas velocity measurement
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Continuous wave gas laser Doppler flow meter for gas velocity measurement
Capacitive mass flow meter with electronic readout for use with liquid hydrogen
Calibration of turbine-type flow meters in liquid hydrogen
Simulation of liquid-hydrogen turbine-type flow meter calibrations using high-pressure nitrogen gas at liquid-hydrogen density
Electromagnetic flow meter for analyzing dynamic flow oscillations in turbopump systems
Cryogenic fluid mass flow measurement methods, noting flow meter calibration
Device determines velocity and electrical conductivity of a moving fluid of high electrical resistance by imposing a transverse electro-quasistatic field on the fluid. Position changes of charge accumulations induced within the fluid by the field are sensed by relative movement between fluid and sensor.
Bearings are removed by the application of a simple hydraulic principle using beeswax in place of a liquid.
Turbine flow meters dynamic calibration employing sinusoidally perturbed orifice flow
A discussion is given of particle lags in mean flows, acoustic oscillations at single frequencies and in turbulent flows. Some simplified cases lead to exact solutions. For turbulent flows linearization of the equation of motion after assuming the fluid and particle streamlines coincide also leads to a solution. The results show that particle lags are a function of particle size and frequency of oscillation. Additional studies are necessary to evaluate the effect of turbulence when a major portion of the energy is concentrated in small eddies.
An eight-channel biomedical telemetry system provides four channels of blood flow measurements in addition to blood-pressure and EKG data. Emphasis is placed on the amplifiers and signal conditioning circuitry required for interfacing of the electromagnetic flow transducers with the transmission and modulation subsystems. The large number of data channels permits measurement of flow distribution as well as total cardiac output. The batteries and electronics for four channels (blood flow) weigh about 500 g and have a volume of 250 cu cm.
The in vivo application of the pulsed ultrasound Doppler velocity meter (PUDVM) for measuring arterial velocity waveforms is reported. In particular, the performance of the PUDVM is compared with a hot film anemometer of proven accuracy.
Experimental data are analyzed to support theoretical predictions for discharge coefficients in circular-arc venturi flow meters operating in the critical sonic flow regime at throat Reynolds numbers above 150 thousand. The data tend to verify the predicted 0.25% decrease in the discharge coefficient during transition from a laminar to turbulent boundary layer. Four different test gases and three flow measurement facilities were used in the experiments with 17 venturis with throat sizes from 0.15 to 1.37 in. and Beta ratios ranging from 0.014 to 0.25. Recommendations are given as to how the effectiveness of future studies in the field could be improved.
Device measures drag of body with known drag coefficient to determine flow rate. Drag on target is transferred by cantilevered arm to fully active strain-gage bridge. Given target will be useful with many types of fluids and flow rates.
The results of analytical and experimental work performed in the design, fabrication, and test of a prototype nonintrusive gaging system for use in monitoring the consumption of earth-storable fuels and oxidants in either a one-g or a zero-g environment are explained. The design specifications were those applicable to the reaction control system and to the orbital maneuvering system (OMS) fuel and oxidant on the space shuttle while in orbit. The major requirement was for the measurement of flow pulses with sufficient accuracy to provide a continuous knowledge of the fuel and oxidant remaining in the OMS system to within 1% or better. An ultrasonic frequency chirp technique was used having a high inherent rejection for signals traversing stray paths, and for random noise generated by the flowing liquid. A detailed analysis of the frequency chirp approach for two modes of operation (period and phase changes), including an error analysis are reported.
Explore the source record for details and available documents.
Circuit using optical sensor, low power counting electronics, oneclip digital-to-analog converter and operational amplifier converts mechanical readout of water, gas, fuel-oil or power meter to analog signal suitable for online processings.
A 205 mm transfer standard orifice plate meter assembly, consisting of two orifice plates in series separated by a length of pipe containing a flow straightener, was calibrated in two water flow facilities. Results show that the agreement in the characteristics of such a differential pressure transfer standard package is within 0.17% over a 10:1 range from flow rates of approximately 8 to 80 l/sec. When the range over which the comparison was made was limited to that for which the calibration graphs gave straight lines, the agreement is 0.1% in 3 of the 4 calibrations (0.17% in the fourth).