Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorescence sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Smartphone-based Dual-channel Immunochromatographic Test Strip with Polymer Quantum Dot Labels for Simultaneous Detection of Cypermethrin and 3-phenoxybenzoic acid

Currently, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) are the primary methods used to detect pesticides and their metabolites for biomonitoring of exposure. Although GC-MS and LC-MS can provide accurate and sensitive measurements, these techniques are not suitable for point-of-care or in-field biomonitoring applications. The objective of this work is to develop a smartphone-based dual-channel immunochromatographic test strip (ICTS) for on-site biomonitoring of exposure to cypermethrin by simultaneous detection of cypermethrin and its metabolite, 3-phenoxybenzoic acid (3-PBA). Polymer carbon dots (PCDs) with ultra-high fluorescent brightness were synthesized and used as signal amplifier in ICTS assay. Cypermethrin (a representative pyrethroid pesticide) and its major metabolite 3-PBA were simultaneously detected to provide more comprehensive analysis of cypermethrin exposure. After competitive immunoreactions between the target sample and the coating antigens preloaded on the test line, the tracer antibody (PCDs conjugated antibody) was quantitatively captured on the test lines. The captured PCDs were inversely proportional to the amount of the target compound in sample. The red fluorescence on the test line then was recorded by a smartphone-based device capable of conducting image analysis and recording. Under optimal conditions, the sensor showed excellent linear responses for detecting cypermethrin and 3-PBA ranging from 1 ng/mL to 100 ng/mL and from 0.1 ng/mL to 100 ng/mL, the limits of detection were calculated to be ~0.35 ng/mL for cypermethrin and ~0.04 ng/mL for 3-PBA, respectively. The results demonstrate that the ICTS device is promising for accurate point-of-care biomonitoring of pesticide exposure.

Zhao, Yuting↗

Probing boron vacancy defects in hBN via single spin relaxometry

Spin defects in solids offer promising platforms for quantum sensing and memory due to their long coherence times and optical addressability. Here, we integrate a single nitrogen-vacancy (NV) center in diamond with scanning probe microscopy to detect, read out, and spatially map spin-based quantum sensors at the nanoscale. Using the boron vacancy ($V$$^{–}_{B}$) center in hexagonal boron nitride—an emerging two-dimensional spin system—as a model, we detect its electron spin resonance indirectly via changes in the spin relaxation time (T 1 ) of a nearby NV center, eliminating the need for optical excitation or fluorescence detection of the $V$$^{–}_{B}$. Cross-relaxation between NV and $V$$^{–}_{B}$ ensembles significantly reduces NV T1, enabling quantitative nanoscale mapping of defect densities beyond the optical diffraction limit and clear resolution of hyperfine splitting in isotopically enriched h 10 B 15 N. Our method demonstrates interactions between spin sensors in 3D and 2D materials, establishing NV centers as versatile probes for characterizing otherwise inaccessible spin defects.

Quantum metrology↗

Multicomponent Nanoparticle Synthesis for Advanced Manufactured Melt Wire Development

Additive manufacturing (AM) based direct-write technologies have emerged as a predominant enabler for the fabrication of advanced passive sensors in-pile applications. This work continues previous efforts with the modification and optimization of synthesis methods for multi-component nanoparticle systems used to support the development, fabrication and testing of AM sensors for peak temperature detection. For this report, bismuth, bismuth/platinum, tin, tin/silver, tin/zinc, indium, and indium/silver bi-metallic nanoparticles were synthesized using the wet chemical methods. The nanoparticles were then characterized with x-ray fluorescence to evaluate the elemental composition and differential scanning to determine the melting point and mass loss of the samples. Results continue to show that bi-metallic nanoparticles are a viable pathway for the fabrication of high-resolution AM melt wires.

36 MATERIALS SCIENCE↗

SIF and Vegetation Indices in the US Midwestern Agroecosystems, 2016-2021, Carbon Monitoring System (CMS)

This dataset contains half-hourly ground solar-induced chlorophyll fluorescence (SIF) and vegetation indices including NDVI, EVI, Red edge chlorophyll index, green chlorophyll index, and photochemical reflectance index at seven crop sites in Nebraska and Illinois for the period 2016-2021. Four sites were located at Eddy Covariance (EC) tower sites (sites US-Ne2, US-Ne3, US-UiB, and US-UiC), and three sites were located on private farms (sites Reifsteck, Rund, and Reinhart). The sites were either miscanthus, corn-soybean rotation or corn-corn-soybean rotation. The spectral data for SIF retrieval and hyperspectral reflectance for vegetation index calculation were collected by the FluoSpec2 system, installed near planting, and uninstalled after harvest to collect whole growing-season data. Raw nadir SIF at 760 nm from different algorithms (sFLD, 3FLD, iFLD, SFM) are included. SFM_nonlinear and SFM_linear represent the Spectral fitting method (SFM) with the assumption that fluorescence and reflectance change with wavelength non-linearly and linearly, respectively. Additional data include two SIF correction factors including calibration coefficient adjustment factor (f_cal_corr_QEPRO) and upscaling nadir SIF to eddy covariance footprint factor (ratio_EC footprint, SIF pixel), and measured FPAR from quantum sensors and Rededge NDVI calculated FPAR. The data are provided in comma-separated values (CSV) format.

Ameriflux↗

On-Chip Single-Layer Integration of Diamond Spins with Microwave and Plasmonic Channels

On-chip scalable integration represents a major challenge for practical quantum devices. One particular challenge is to implement on-chip optical readout of spins in diamond. This readout requires simultaneous application of optical and microwave fields along with the efficient collection of fluorescence. These requirements are typically met using bulk optical components and dedicated microwave lines. Here, we experimentally demonstrate an on-chip integrated interface for diamond nitrogen vacancy (NV) spin-state preparation and readout, implemented in a planar single layer with only one patterning step. A nanodiamond with NV centers is positioned inside a v-groove waveguide milled in a thick gold film. The gold film carries the microwave control signal, while the v-groove acts as a fluorescence collector and, potentially, as an integrated pump filter. Hence, the device dimensions and fabrication complexity are substantially reduced. Our approach fosters further development of ultracompact nanoscale quantum sensors and quantum information processing devices on a monolithic platform.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

Development of a large array of Silicon Drift Detectors for high-rate synchrotron fluorescence spectroscopy

An array of small-area Silicon Drift Detectors (SDD), named Hera, has been developed at Brookhaven National Laboratory (BNL) in the past few years. Its primary application is high-rate spectroscopy at synchrotrons. Each SDD pixel is a 1 mm × 1 mm square to match the footprint of the original diode-based pixel detector called Maia, which was developed for the same application. The replacement of the diode with an SDD allows for better energy resolution at short shaping times and an increased stability of the detector. 32, 96, and 384-channel arrays were designed and fabricated and achieved a Full Width Half Maximum (FWHM) as low as 176 eV at 5.9 keV with peaking time of 1 μs at -13°C. The sensor design, simulation, fabrication, its readout system, and its spectroscopic performance are reported.

47 OTHER INSTRUMENTATION↗

DiB-splits: nature-guided design of a novel fluorescent labeling split system

Fluorogen-activating proteins (FAPs) are innovative fluorescent probes combining advantages of genetically-encoded proteins such as green fluorescent protein and externally added fluorogens that allow for highly tunable and on demand fluorescent signaling. Previously, a panel of green- and red-emitting FAPs has been created from bacterial lipocalin Blc (named DiBs). Here we present a rational design as well as functional and structural characterization of the first self-assembling FAP split system, DiB-splits. This new system decreases the size of the FAP label to ~8–12 kDa while preserving DiBs’ unique properties: strong increase in fluorescence intensity of the chromophore upon binding, binding affinities to the chromophore in nanomolar to low micromolar range, and high photostability of the protein-ligand complex. These properties allow for use of DiB-splits for wide-field, confocal, and super-resolution fluorescence microscopy. DiB-splits also represent an attractive starting point for further design of a protein-protein interaction detection system as well as novel FAP-based sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

Representation of Leaf-to-Canopy Radiative Transfer Processes Improves Simulation of Far-Red Solar-Induced Chlorophyll Fluorescence in the Community Land Model Version 5

Recent advances in satellite observations of solar-induced chlorophyll fluorescence (SIF) provide a new opportunity to evaluate and constrain the simulation of terrestrial gross primary productivity (GPP). Accurate representation of the processes driving SIF emission and the radiative transfer of SIF to remote sensing sensors is an essential prerequisite for the evaluation and data assimilation. Recently, SIF simulations have been incorporated into several land surface models, but the scaling of SIF from leaf-level to canopy level is usually not well-represented. In this work, we incorporate the simulation of far-red SIF observed at nadir into the Community Land Model version 5 (CLM5). An efficient and accurate method based on escape probability is developed to scale SIF from leaf-level to top-of-canopy while taking clumping and the radiative transfer processes into account. SIF simulated by CLM5 and a canopy-level model agreed well at sites except one in needle leaf forest (R2>0.91, root-mean-square error < 0.19W m -2 sr -1 um -1 ), and captured the day-to-day variation of tower-measured SIF at temperate forest sites (R 2 >0.68). At the global scale, simulated SIF generally captured the spatial and seasonal pat37 terns of satellite-observed SIF (R2 > 0.76 except for tropical forest). Factors including the fluorescence emission model, clumping, bidirectional effect, and canopy properties (leaf optical properties and leaf area index) had considerable impacts on SIF simulation, and the discrepancies between simulated and observed SIF varied with plant functional type. By improving the representation of radiative transfer for SIF simulation, our model allows better comparisons between simulated and observed SIF towards constraining and evaluating GPP simulations.

59 BASIC BIOLOGICAL SCIENCES↗

Resistive Coatings for High-performance, Low-background MCPs Operating Across Broad Temperature Ranges and at Cryogenic Temperatures

Microchannel plate with improved thermo-electric properties are a high risk, high payoff development undertaken by a consortium of effort that links the Argonne National Lab, the Space-Science Lab at UC Berkeley and the small businesses (Incom Inc.) that will commercialize the advanced technology in open MCPs and LAPPDs. This development will satisfy the needs for new instrumentation for homeland security (non-proliferation) sensors to screen vehicles and cargo for Special Nuclear Materials (SNMs) and scientific detectors for astrophysics, electron microscopy, time-of-flight mass spectrometry, molecular and atomic collision studies, and fluorescence imaging applications in biotechnology and medical imaging products including positron emission tomography (PET scanning).

99 GENERAL AND MISCELLANEOUS↗

Molecular To Mesoscale Targeting of Oxoanions with Multi-Tasking Hosts

Achieving a better understanding of anion interactions both in solution and crystalline state was the overarching goal of this project. Anions are everywhere throughout Nature and play important roles in biological and environmental processes. They can be beneficial or deleterious or both in different situations and concentrations. For either reason it is important to have molecules that can bind anions for key needs that benefit society. However, recognition of specific anions is challenging due to the diffuse nature of their negative charge(s) as well as their various shapes and sizes. Understanding the basic properties of anions and how they interact with other molecules and ions in surrounding environments is key to selective recognition. In this project multi-tasking molecules for selective binding of targeted anions were designed to achieve cooperativity and synergism in one rather than multiple host molecules, including (1) cation:anion pair hosts for anions with charges of -2 or greater; (2) pH and redox activated hosts for on-off binding and release; and (3) multiple anion capture in extended host networks. Our design strategy was to combine the use of simple inexpensive building blocks and high yield synthetic pathways to provide economically feasible scale-up for applications. Oxoanions representing multiple shapes and charges were chosen based on having the potential for significant impact on DOE separations needs. Amide/amine-based macrocycles and urea/amine-based chelates and macrocycles with multiple hydrogen bonding sites provided the basic anion-binding frameworks. Successful multi-tasking outcomes were forthcoming in all three tasks. In Task 1, successful ion pair binding for anions with multiple charges was achieved. Furthermore, the ion pair molecules were capable of extended interactions through supramolecular intertwining, like fishing nets for capturing pools of fish (also fitting with Task 3). In Task 2, molecules were synthesized possessing on-off switches. These included a pH sensitive sensor for on-off binding of anions in general, as well as an electrochemical sensor selective for sulfate capture. Three new classes of extended anion host networks capable of binding multiple ions was a major outcome of Task 3. These systems included: anion sensitive, fluorescent organogels; channel-forming macrocycles for studying anion-water including larger macrocyclic cluster sandwiches; and, the offshoot of Task 1, fishing net ion-pair networks for higher valent anions. These strategies can be expanded in the future to other ions and molecules for a better understanding of intermolecular and interionic interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION↗

Influence of Carbon-Nitride Dot-Emitting Species and Evolution on Fluorescence-Based Sensing and Differentiation

Carbon dots have attracted widespread interest for sensing applications based on their low cost, ease of synthesis, and robust optical properties. We investigate structure–function evolution on multiemitter fluorescence patterns for model carbon-nitride dots (CNDs) and their implications on trace-level sensing. Hydrothermally synthesized CNDs with different reaction times were used to determine how specific functionalities and their corresponding fluorescence signatures respond upon the addition of trace-level analytes. Archetype explosives molecules were chosen as a testbed due to similarities in substituent groups or inductive properties (i.e., electron withdrawing), and solution-based assays were performed using ratiometric fluorescence excitation–emission mapping (EEM). Analyte-specific quenching and enhancement responses were observed in EEM landscapes that varied with the CND reaction time. We then used self-organizing map models to examine EEM feature clustering with specific analytes. Finally, the results reveal that interactions between carbon-nitride frameworks and molecular-like species dictate response characteristics that may be harnessed to tailor sensor development for specific applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling a recurrent neural network to SPAD TCSPC systems for real-time fluorescence lifetime imaging

Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. Inspired by the concept of Edge Artificial Intelligence (Edge AI), we propose a robust approach that enables fast FLI with no degradation of accuracy. This approach couples a recurrent neural network (RNN), which is trained to estimate the fluorescence lifetime directly from raw timestamps without building histograms, to SPAD TCSPC systems, thereby drastically reducing transfer data volumes and hardware resource utilization, and enabling real-time FLI acquisition. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in the presence of background noise by a large margin. To explore the ultimate limits of the approach, we derive the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. To demonstrate real-time operation, we build a FLI microscope based on an existing SPAD TCSPC system comprising a 32 x 32 SPAD sensor named Piccolo. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on the Xilinx Kintex-7 FPGA that controls the Piccolo. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications, including biological imaging, biomedical diagnostics, and fluorescence-assisted surgery, etc.

47 OTHER INSTRUMENTATION↗

Comparison of total emitted solar-induced chlorophyll fluorescence (SIF) and top-of-canopy (TOC) SIF in estimating photosynthesis

We report many studies have shown that solar-induced fluorescence (SIF) has a good potential to predict gross primary production (GPP) of vegetation. What we measured by remote sensing or near-surface platforms is top-of-canopy (TOC) SIF (SIF toc ), which is not necessarily equal or proportional to total emitted SIF (SIF tot ) from the entire canopy due to the (re)absorption and scattering effects. However, photosynthesis, the process that plants use to fix carbon from the atmosphere, occurs at the entire vertical canopy. Here, by using the recollision theory, we calculated SIF tot at 760 nm from the measured SIF toc , hyperspectral reflectance (R), canopy interception (i) and leaf albedo (ω l ). Among them, both SIF toc and R can be obtained from concurrent TOC spectral measurements; i and ω l in the near-infrared region can be estimated from the open access datasets with a good accuracy. Our result confirms that the measured SIF toc only accounts for a small fraction of SIF tot : the above-the-canopy sensor can only “see” on average 22.9% of SIF tot at Harvard Forest. SIF tot has the following advantages over SIF toc in estimating GPP: (1) SIF tot improves the diurnal estimate of canopy GPP, especially capable to capture the midday depression of photosynthesis which may cause the large discrepancies between SIF toc and GPP on a diurnal basis, (2) SIF tot produces a stronger correlation with GPP from plants with complex canopy structure or under sky conditions with more diffuse irradiance, and (3) the SIF tot -GPP relationship shows a stronger resilience to environmental stresses. The fluorescence escape ratio (f esc ), the ratio between SIF toc multiplied by π and SIF tot , is mostly determined by the sun-canopy-sensor geometry and leaf inclination distribution. The effect of LAI and the leaf chlorophyll concentration on f esc is marginal at the 760 nm wavelength. Our results suggest that converting SIF toc into SIF tot provides a better tool to understand and estimate GPP.

54 ENVIRONMENTAL SCIENCES↗

Valence-to-core X-ray emission spectroscopy of titanium compounds using energy dispersive detectors

X-ray emission spectroscopy (XES) of transition metal compounds is a powerful tool for investigating the spin and oxidation state of the metal centers. Valence-to-core (vtc) XES is of special interest, as it contains information on the ligand nature, hybridization, and protonation. To date, most vtc-XES studies have been performed with high-brightness sources, such as synchrotrons, due to the weak fluorescence lines from vtc transitions. Here, we present a systematic study of the vtc-XES for different titanium compounds in a laboratory setting using an X-ray tube source and energy dispersive microcalorimeter sensors. With a full-width at half-maximum energy resolution of approximately 4 eV at the Ti Kβ lines, we measure the XES features of different titanium compounds and compare our results for the vtc line shapes and energies to previously published and newly acquired synchrotron data as well as to new theoretical calculations. Finally, we report simulations of the feasibility of performing time-resolved vtc-XES studies with a laser-based plasma source in a laboratory setting. Our results show that microcalorimeter sensors can already perform high-quality measurements of vtc-XES features in a laboratory setting under static conditions and that dynamic measurements will be possible in the future after reasonable technological developments.

36 MATERIALS SCIENCE↗