Search NASA⌕ Search

SEARCH · Search NASA

Results for “forensic science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterizing microscale signatures in uranium ore concentrates using electron probe microanalyzer

Impurities in uranium ore concentrates (UOCs) serve as forensic signatures of processing history and origin. Here, this study utilizes Electron Probe Microanalyzer (EPMA) to characterize microscale compositional and textural features in individual UOC particles from both commercial and bench-scale production. At the particle scale, multiple internal phases with distinct morphologies, chemical signatures, and stoichiometries are documented. Our data shows that chemical impurities are heterogeneously distributed within single particles and among particles within a sample. These microscale heterogeneities correlate with known processing histories, indicating that microscale signatures of early fuel cycle materials can provide valuable information for nuclear forensic material analysis.

organic↗

Fact Sheet - Long-length Scintillating Fibers for Radiation Detection

As the world looks to underground geological repositories for storing nuclear waste, technologies to safeguard the material are needed. An example of a project that developed a new technology is Tripwire. Tripwire proposes a multi-sensor system approach for geological spent nuclear fuel repositories that relies of radiation, vibration, and electromagnetic detection. Tripwire was developed by the Applied Radiation Measurements and Systems (ARMS) group at INL and sponsored by the National Nuclear Security Administration (NNSA). The ARMS group performs research and development, testing and evaluation, operational support, and training focused on applied ionizing radiation detection and measurement. Application areas include nuclear engineering for advanced reactors and fuel cycle operations, nuclear nonproliferation, nuclear counterproliferation, nuclear forensics, and arms control and disarmament.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Cross‐Cultural Validation of the Binge Eating Disorder Screener‐7 ( BEDS ‐7) Across 42 Countries

ABSTRACT Objective This study aimed to evaluate the reliability and validity of the Binge Eating Disorder Screener‐7 (BEDS‐7) across 42 countries and 26 languages, assessing its reliability and validity as a screening tool for binge‐eating disorder (BED) in diverse cultural contexts. Specifically, it sought to enhance early recognition of BED symptoms in primary care settings globally, contributing to a standardized framework for assessing BED. Method The International Sex Survey, a cross‐sectional online study, was conducted in 42 countries and 26 languages. A diverse community sample of 82,243 participants, aged 18 years or older, completed the BEDS‐7 and measures of sexuality, mental health, substance use, and sociodemographic characteristics. Confirmatory factor analyses and tests of measurement invariance were employed to evaluate the reliability and validity of the BEDS‐7 across languages, countries, genders, and sexual orientations. Results The BEDS‐7 demonstrated scalar factorial invariance across languages and countries, indicating consistent factor loadings and item intercepts. In contrast, the screener showed residual invariance across gender and sexual orientation groups, supporting its robustness across these demographics. Kruskal–Wallis tests revealed significant differences in BED symptoms across languages, countries, genders, and sexual orientations, with the highest BED scores observed among queer, pansexual, and gender‐diverse individuals. The BEDS‐7 also demonstrated adequate reliability (Cronbach's alpha > 0.80) and moderate criterion validity. Discussion The findings provide further evidence of the reliability and validity of the BEDS‐7 as a potential screening tool for identifying probable cases of BED globally, facilitating early intervention in primary care settings.

Gewirtz‐Meydan, Ateret [School of Social Work, Fac↗

Improving microstructures segmentation via pretraining with synthetic data

Image analysis of material microstructures through microscopy is an integral capability in the field of materials science. The topological and chemical information obtained through microscopy allow us to draw vital connections between material microstructures, properties, and processing. While scanning electron microscopy (SEM) is able to yield a considerable wealth of information interpretable by the intuition of experts, there has been considerable interest in using machine learning, convolutional neural networks (CNNs) in particular, for such image analysis task. Training CNNs for an image analysis task requires a large annotated dataset. However, in many materials science applications, obtaining a large annotated dataset is cost and labor intensive. In this work, we study the use of synthetic data to enlarge the available annotated experimental data of uranium oxide. We utilize a modified Potts model to simulate uranium oxide particles with morphologies similar to those observed experimentally. We then leverage an image-to-image translation model to synthesize the simulated particles as if they are acquired with SEM. Through this process, we obtain pairs of particle images and their corresponding SEM representations, which corresponds to pairs of annotations and images. Unlike previous works, we leverage synthetic data for pretraining a CNN model prior, and finetune that model further with experimental data. We experimentally demonstrate that using synthetic data as incremental learning process benefits the overall performance compared to training a model on combined synthetic and experimental data.

36 MATERIALS SCIENCE↗

Cluster-Graph Fingerprinting: A Framework for Quantitative Analysis of Machine-Learned Interatomic Model Training and Simulation Data

Machine-learned interatomic models represent a significant advancement in simulation methods, extending the predictive ability of first-principles methods to previously inaccessible length and time scales. However, the data-driven nature of these models can lead to difficult-to-detect errors that can compromise prediction accuracy. To address this challenge, we introduce a novel fingerprinting approach based on the Chebyshev Interaction Model for Efficient Simulation (ChIMES) ML-IAM graph-based descriptor. Our strategy enables efficient and statistically rigorous analysis of system configurations used in ML-IAM training and those generated by their application, e.g., in molecular dynamics simulations. We demonstrate that these fingerprints can effectively assess novelty of a configuration relative to an existing data set and determine dissimilarity among individual configurations, which are two key tasks in workflows for active learning-based ML-IAM training, data set curation, and on-the-fly uncertainty quantification.

36 MATERIALS SCIENCE↗

National Nuclear Materials Archive (NNMA) - Specimen Selection and Sampling at the Y-12 National Security Complex

Y-12 has made significant progress in FY21 towards National Nuclear Materials Archive (NNMA) program objectives related to the identification, nomination, sampling, sub-sampling and shipment of NNMA materials. Y-12 efforts in FY22 and beyond are anticipated to transition away from material identification and nomination to an emphasis on sampling/sub-sampling and long-term storage of NNMA specimens. Long-term storage efforts will also involve more emphasis on insuring that the nuclear forensics value of NNMA items is guaranteed through appropriate preservation processes.

36 MATERIALS SCIENCE↗

PIXE – State of the Art, Systems, Challenges

Particle-induced X-ray emission (PIXE) is an analytical technique for elemental analysis in which a charged-particle beam (most commonly protons, but also alpha particles or heavier ions) ionizes inner-shell electrons in target atoms. When these vacancies are filled by outer-shell electrons, the atom emits characteristic X-rays (e.g., Kα, Kβ, L-series) whose energies are unique to each element. Measuring the X-ray spectrum therefore enables identification of the elements present and, with appropriate calibration and modeling, their concentration. PIXE provides rapid, simultaneous, quantitative multi-element detection with trace-level sensitivity for many mid- to high-Z elements, often with minimal sample preparation. It is widely used across materials science (thin films, alloys, corrosion), geology (mineral chemistry, provenance) and environmental monitoring (aerosols, particulates, soils); semiconductor contamination analysis (wafer surface/trace metals), cultural heritage (pigments, inks, archaeological artifacts) and forensics (gunshot residue, glass/pain), and biological/medical studies (tissue/biomaterial trace-element mapping).

47 OTHER INSTRUMENTATION↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Single particle trace element analysis of uranium oxide standards with laser-induced breakdown spectroscopy

Femtosecond Laser-Induced Breakdown Spectroscopy (LIBS) was used to analyze over 1000 individual particles of uranium oxide trace element standard CRM124. Intra-granular analysis showed elemental concentrations were consistent across different surface locations on each uranium grain. However, inter-granular comparison revealed large heterogeneity between different grains of the same sample. By comparing the distribution of elemental concentrations across the particle populations, we were able to correctly identify a manufacturing process involving wet chemistry, rather than a dry mixing of two powders to give an overall chemical average. In conclusion, this demonstrates the utility of LIBS as a large-scale single particle analysis tool for nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Morphological and chemical characteristics of oxide scales formed on δ-Phase plutonium metal alloys I: 3.5 at% ga

Focused ion-beam scanning electron microscopy (FIB-SEM) and three-dimensional (3D) microscopy were applied to characterize the subsurface morphological features of oxide scales formed on an ~3.5 at.% Ga plutonium (Pu) metal alloy. Using the FIB-SEM technique, a number of morphological features formed in the interior of the oxide scale from Pu metal's environmental exposure were observed and identified. Here, Auger electron spectroscopy (AES) was utilized to characterize the cross-sectional composition and chemistry of the oxide scale. The oxide scale formed during inert storage and operational environments has a characteristic internal scale structure that includes a relatively dense oxide layer with some lateral and transverse cracking. Generally, after subsequent exposure to dry air environment, the oxide scale retained most of the original structural and chemical characteristics. However, after aging in a moist air environment, while the oxide scale was found to maintain the chemical characteristics of the source oxide, the scale was found to be on average thinner and without the previously observed internal microcracking, likely the result of spallation of the source scale during exposure to the new environment.

36 MATERIALS SCIENCE↗

Morphological and chemical characteristics of oxide scales formed on δ-phase plutonium metal alloys II: 2.0 at% Ga

The focused ion-beam scanning electron microscopy (FIB-SEM) and three-dimensional (3D) microscopy were applied to characterize the subsurface morphological features of oxide scales formed on an ~2.0 at. % Ga plutonium (Pu) metal alloy. Using the FIB-SEM technique, a number of morphological features formed in the interior of the oxide scale from Pu metal’s environmental exposure were observed and identified. Auger electron spectroscopy (AES) was utilized to characterize the cross-sectional composition and chemistry of the oxide scale. The oxide scale formed during inert storage and operational environments was found to be highly variable in thickness and morphology, presenting some regions with a thin (<400 nm), dense oxide layer and others with a thick (>2 µm) scale with substantial lateral cracking. After subsequent exposure to dry air environment, the oxide scale became thicker (~4 µm) and slightly more porous. The changes following aging in a moist air environment were observed to be more severe, with the formation of a highly porous internal structure containing significant lateral and transverse cracking. In comparison to the scale formed on an ~3.5 at. % Ga-Pu metal alloy, the oxide morphology of the lower gallium alloy investigated here exhibited greater variation in thickness and a noteworthy dependence on the presence of water vapor, particularly in terms of the internal porosity formed during growth of the oxide.

36 MATERIALS SCIENCE↗

Resolving Mixtures of Soot Characterized by SP-AMS Spectra Using a Latent Dirichlet Allocation Model

Soot produced by detonation or combustion events exhibits different chemical properties depending on the fuel, device construction, and environmental conditions in which the event occurs. These properties can be useful for defining relevant signatures for probabilistically identifying the different types of events that occurred, based on the soot that is produced from these events. However, it is rare to observe samples of soot from a detonation or combustion that are not contaminated by outside particles. In this paper, we present a method for resolving mixtures of soot to determine the contributions of sources that may be present in samples of recovered soot. We use Latent Dirichlet Allocation to describe the generative process for a sample of recovered soot, and use Variational Bayesian Inference to learn about the parameters associated with the generative model. We demonstrate the utility of this method by considering real samples of mixtures of soot under various frameworks to show that the model is able to identify the different components present in a sample of soot as well as their mixing proportions.

54 ENVIRONMENTAL SCIENCES↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry↗