Search NASA⌕ Search

SEARCH · Search NASA

Results for “framing camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Machine Vision-based Robot Manipulators for Nuclear Applications - 20370

Decommissioning and dismantling of nuclear facilities are major challenges facing the nuclear industry. Robot manipulators with capabilities of restoring nuclear structures and significantly prolonging nuclear power generation in addition to their applications in decommissioning and dismantling (D and D) would immensely ease the above-mentioned challenge. Ability to remotely sense/monitor and analyze dangerous and hazardous environments such as nuclear reactors as well as performing reparatory tasks in such environments using robot manipulators require additional information from vision sensors. Structural sample collection and inspection as well as restoration require object and position information. Computer vision is used to obtain precise 3D position information. The current work uses the Sawyer robot with the integrated Cognex camera. The research presents an approach to facilitate and improve operations in a nuclear reactor using robotic vision control. The vision control system is modeled with Augmented Image Space-based visual servoing approach. Results showing accurate robot control. Object recognition is used to recognize the image and calculate it poses. To transform coordinates of the object's pose from the camera frame to the robotic frame transformation matrices are employed. Future work will employ a 3D camera (with depth information) using Denso robot. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Hyperchromatic Lens for Recording Time-Resolved Phenomena

Current methods of recording multiple-frame images at short time scales are limited by electro-optic tube physics and radiometry. A new all-optical methodology has been developed for the capture of a high number of quasi-continuous effective frames of 2-D data at very short time scales (from less than 10–12 to more than 10–8 seconds), with improvement over existing framing camera technology in terms of short recording windows and effective number of frames. The methodology combines active illumination in which wavelength is dependent upon time and spatial position to encode temporal phenomena onto wavelength; a hyperchromatic lens to map wavelength onto axial position, and a recording technology, such as holography or plenoptic imaging, to capture the resultant focal stack in both spatial (imaging) and longitudinal (temporal) axes. The novel hyperchromatic lens we designed incorporates a combination of diffractive and refractive components to maximally separate focal position as a function of wavelength, resulting in a 45 mm focal stack with nearly constant magnification for just 5 nm of illumination bandwidth. The fabricated lens assembly was qualified as meeting design requirements and images with the expected magnification at nearly the diffraction limit across the spectral range. This paper will focus on hyperchromatic lens design.

hyperchromat, time-resolved imaging, plenoptic ima↗

Post-Shot Report for OMEGA Double Cylinders (CylDRT 22B)

The direct-drive double cylinder experimental platform is a high-energy-density (HED) science platform designed to image an imploding cylindrical target. The target consists of a directly-driven outer cylinder and a shock-and-collision driven inner cylinder. The purpose of this platform is to study hydrodynamic instability growth on the inner cylinder, the outer surface of which is classically Rayleigh-Taylor unstable during the acceleration phase. We present results from recent experiments at the OMEGA laser facility. These experiments were designed as a proof-of-principle for the platform, using the same cylinder exterior dimensions and direct-drive beam configuration as previous single cylinder experiments. In these experiments, three sets of targets were fielded: no machined perturbations (smooth), a sinusoidal mode-10 perturbation on the outer surface of the inner cylinder, and a mode-20 perturbation on the outer surface of the inner cylinder. The primary diagnostic was a gated x-ray framing camera which imaged the backlit inner cylinder on-axis for sixteen frames over a time window of 1 ns for each shot. A second side-lit radiograph captured one image per shot, diagnosing axial uniformity. In this report we include an overview of the results from both the backlighter and the sidelighter diagnostics. We discuss at length the experimental analysis process. Finally, we present the results of the smooth target implosion trajectory and compare them to post-shot simulations. We see favorable agreement between simulation and experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary design of an intermittent smoke flow visualization system

A prototype intermittent smoke flow visualization system for studying the flowfield of an aircraft in flight has been constructed and demonstrated. It provides discrete pulses of dense white smoke suitable for video imaging to determine the unsteady vortex core trajectory of fluid elements in a high angle-of-attack flowfield. Two methods of pulsing the smoke were initially investigated: (1) periodically diverting the smoke between two exit ports and (2) completely blocking the smoke flow for short times. System dynamics have been modeled mathematically, data have been collected in a wind tunnel with blockage times up to 80 milliseconds, and the prototype is currently being flown on a general aviation airplane to collect three-dimensional video data. Three different plenum chamber sizes are available. Data collected so far are consistent and repeatable, though care must be taken to provide adequate contrast levels for accurate video resolution. Camera frame rates of at least 180 frames/second and wide angle lenses for the video cameras are needed to acquire meaningful vortex core velocities and accelerations for the general aviation test aircraft installation.

Ward, D. T.↗

Infrared Imaging Camera Final Report CRADA No. TC02061.0

This was a collaborative effort between the University of California, Lawrence Livermore National Laboratory (LLNL) and Cordin Company (Cordin) to enhance the U.S. ability to develop a commercial infrared camera capable of capturing high-resolution images in a l 00 nanoseconds (ns) time frame. The Department of Energy (DOE), under an Initiative for Proliferation Prevention (IPP) project, funded the Russian Federation Nuclear Center All-Russian Scientific Institute of Experimental Physics (RFNC-VNIIEF) in Sarov. VNIIEF was funded to develop a prototype commercial infrared (IR) framing camera and to deliver a prototype IR camera to LLNL. LLNL and Cordin were partners with VNIIEF on this project. A prototype IR camera was delivered by VNIIEF to LLNL in December 2006. In June of 2007, LLNL and Cordin evaluated the camera and the test results revealed that the camera exceeded presently available commercial IR cameras. Cordin believes that the camera can be sold on the international market. The camera is currently being used as a scientific tool within Russian nuclear centers. This project was originally designated as a two year project. The project was not started on time due to changes in the IPP project funding conditions; the project funding was re-directed through the International Science and Technology Center (ISTC), which delayed the project start by over one year. The project was not completed on schedule due to changes within the Russian government export regulations. These changes were directed by Export Control regulations on the export of high technology items that can be used to develop military weapons. The IR camera was on the list that export controls required. The ISTC and Russian government, after negotiations, allowed the delivery of the camera to LLNL. There were no significant technical or business changes to the original project.

47 OTHER INSTRUMENTATION↗

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimeter (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single cw laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640x480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.↗

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimetric (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single CW laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640 x 480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.↗

Ambient-Light-Canceling Camera Using Subtraction of Frames

The ambient-light-canceling camera (ALCC) is a proposed near-infrared electronic camera that would utilize a combination of (1) synchronized illumination during alternate frame periods and (2) subtraction of readouts from consecutive frames to obtain images without a background component of ambient light. The ALCC is intended especially for use in tracking the motion of an eye by the pupil center corneal reflection (PCCR) method. Eye tracking by the PCCR method has shown potential for application in human-computer interaction for people with and without disabilities, and for noninvasive monitoring, detection, and even diagnosis of physiological and neurological deficiencies. In the PCCR method, an eye is illuminated by near-infrared light from a lightemitting diode (LED). Some of the infrared light is reflected from the surface of the cornea. Some of the infrared light enters the eye through the pupil and is reflected from back of the eye out through the pupil a phenomenon commonly observed as the red-eye effect in flash photography. An electronic camera is oriented to image the user's eye. The output of the camera is digitized and processed by algorithms that locate the two reflections. Then from the locations of the centers of the two reflections, the direction of gaze is computed. As described thus far, the PCCR method is susceptible to errors caused by reflections of ambient light. Although a near-infrared band-pass optical filter can be used to discriminate against ambient light, some sources of ambient light have enough in-band power to compete with the LED signal. The mode of operation of the ALCC would complement or supplant spectral filtering by providing more nearly complete cancellation of the effect of ambient light. In the operation of the ALCC, a near-infrared LED would be pulsed on during one camera frame period and off during the next frame period. Thus, the scene would be illuminated by both the LED (signal) light and the ambient (background) light during one frame period, and would be illuminated with only ambient (background) light during the next frame period. The camera output would be digitized and sent to a computer, wherein the pixel values of the background-only frame would be subtracted from the pixel values of the signal-plus-background frame to obtain signal-only pixel values (see figure). To prevent artifacts of motion from entering the images, it would be necessary to acquire image data at a rate greater than the standard video rate of 30 frames per second. For this purpose, the ALCC would exploit a novel control technique developed at NASA s Jet Propulsion Laboratory for advanced charge-coupled-device (CCD) cameras. This technique provides for readout from a subwindow [region of interest (ROI)] within the image frame. Because the desired reflections from the eye would typically occupy a small fraction of the area within the image frame, the ROI capability would make it possible to acquire and subtract pixel values at rates of several hundred frames per second considerably greater than the standard video rate and sufficient to both (1) suppress motion artifacts and (2) track the motion of the eye between consecutive subtractive frame pairs.

Morookian, John Michael↗

Fast camera imaging of plasmas in Alcator C-Mod and W7-X

In this work we present an analysis of fast-camera imaging of Alcator C-Mod's divertor region and of the plasma cross section in the W7-X stellarator. In C-Mod, the dynamics of intermittent edge plasma filaments are imaged at 397,100 frames per second in an oblique view. An automatic pipeline was developed to reconstruct the filament motion in the R, Z plane of the divertor using EFIT field line projections. Next, we added our fast-framing camera to W7-X's diagnostic suite for the 2017 run campaign, the first with a divertor. It has a tangential view of the machine cross section, including part of a divertor module. The view is coupled to the camera via a coherent fiber bundle. The spatial resolution is 2–4 cm and the typical plasma brightness limits the fastest usable frame rate to 30k frames/s. We observe filaments in the plasma boundary that rotate around the magnetic axis during radiative collapse; filaments were observed in steady state in the limiter configuration of W7-X by Kocsis et al. [1]. We also observe for the first time a 1–2 kHz quasi-coherent fluctuation in divertor target emissions in the W7-X “standard” magnetic configuration. Finally, a rough analysis of edge gas fueling efficiency using fast camera data and S/XB coefficients finds that fueling is less efficient at densities higher than 4 × 10 19 m -3 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LiDAR-Aided Interior Orientation Parameters Refinement Strategy for Consumer-Grade Cameras Onboard UAV Remote Sensing Systems

Unmanned aerial vehicles (UAVs) are quickly emerging as a popular platform for 3D reconstruction/modeling in various applications such as precision agriculture, coastal monitoring, and emergency management. For such applications, LiDAR and frame cameras are the two most commonly used sensors for 3D mapping of the object space. For example, point clouds for the area of interest can be directly derived from LiDAR sensors onboard UAVs equipped with integrated global navigation satellite systems and inertial navigation systems (GNSS/INS). Imagery-based mapping, on the other hand, is considered to be a cost-effective and practical option and is often conducted by generating point clouds and orthophotos using structure from motion (SfM) techniques. Mapping with photogrammetric approaches requires accurate camera interior orientation parameters (IOPs), especially when direct georeferencing is utilized. Most state-of-the-art approaches for determining/refining camera IOPs depend on ground control points (GCPs). However, establishing GCPs is expensive and labor-intensive, and more importantly, the distribution and number of GCPs are usually less than optimal to provide adequate control for determining and/or refining camera IOPs. Moreover, consumer-grade cameras with unstable IOPs have been widely used for mapping applications. Therefore, in such scenarios, where frequent camera calibration or IOP refinement is required, GCP-based approaches are impractical. To eliminate the need for GCPs, this study uses LiDAR data as a reference surface to perform in situ refinement of camera IOPs. The proposed refinement strategy is conducted in three main steps. An image-based sparse point cloud is first generated via a GNSS/INS-assisted SfM strategy. Then, LiDAR points corresponding to the resultant image-based sparse point cloud are identified through an iterative plane fitting approach and are referred to as LiDAR control points (LCPs). Finally, IOPs of the utilized camera are refined through a GNSS/INS-assisted bundle adjustment procedure using LCPs. Seven datasets over two study sites with a variety of geomorphic features are used to evaluate the performance of the developed strategy. The results illustrate the ability of the proposed approach to achieve an object space absolute accuracy of 3–5 cm (i.e., 5–10 times the ground sampling distance) at a 41 m flying height.

47 OTHER INSTRUMENTATION↗

Geologic sketch map of the candidate Proclus Apollo landing site, part K

An Apollo 15 panoramic camera frame was used as a base for a geologic sketch map of an area near Proclus Crater. The map was prepared to investigate the usefulness of the panoramic camera photography in large-scale geologic mapping and to assess the geologic value of the area as a potential Apollo landing site. The photographs, taken under high solar illumination, resulted in good definition of albedo features, and stereoscopic viewing provided extreme clarity of topographic relief with terrain units easily delineated. The geological characteristics of the area as evidenced by the high-resolution photographs is discussed. It is concluded that the panoramic camera photographs reveal a wealth of detail and are eminently suited for geologic mapping purposes. In addition, the Proclus area, as a potential landing site, offers relatively rough plains terrain.

Lucchitta, B. K.↗

CCD imaging instruments for planetary spacecraft applications

The development of new spacecraft camera systems to be used in conjunction with CCD sensors is reported. A brief overview of the science objectives and engineering constraints which influence the design of cameras for deep space is followed by a review of two current development programs, one leading to a line scan imager and the other to an area array frame camera. For each of these, a general description of the imager is given. It is evident that currently available CCDs fall short of requirements in some respects.

Reilly, T. H.↗

The x-ray calibration facility of the laser integration line in the 0.9-10 keV range: The high energy x-ray source and some applications

The laser integration line (LIL) located at CEA-CESTA is equipped with x-ray plasma diagnostics using different kinds of x-ray components such as filters, mirrors, crystals, detectors, and cameras. The CEA-DAM of Arpajon is currently developing x-ray calibration methods and carrying out absolute calibration of LIL x-ray photodetectors. To guarantee LIL measurements, detectors such as x-ray cameras must be regularly calibrated close to the facility. A new x-ray facility is currently available to perform these absolute x-ray calibrations. This paper presents the x-ray tube based high energy x-ray source delivering x-ray energies ranging from 0.9 to 10 keV by means of an anode barrel. The purpose of this source is mainly to calibrate LIL x-ray cameras but it can also be used to measure x-ray filter transmission of plasma diagnostics. Different x-ray absolute calibrations such as x-ray streak and framing camera yields, x-ray charge-coupled device quantum efficiencies, and x-ray filter transmissions are presented in this paper. A x-ray flat photocathode detector sensitivity calibration recently performed for a CEA Z-pinch facility is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-641: Proton Range Measurements Using a Geometrically Calibrated Liquid Scintillator Detector

Purpose: The purpose of this work is to develop a geometric calibration method to accurately calculate physical distances within a liquid scintillator detector and to assess the accuracy, consistency, and robustness of proton beam range measurements when using a liquid scintillator detector system with the proposed geometric calibration process. Methods: We developed a geometric calibration procedure to accurately convert pixel locations in the camera frame into physical locations in the scintillator frame. To ensure accuracy, the geometric calibration was performed before each experiment. The liquid scintillator was irradiated with spot scanning proton beams of 94 energies in two deliveries. A CCD camera was used to capture the two-dimensional scintillation light profile of each of the proton energies. An algorithm was developed to automatically calculate the proton range from the acquired images. The measured range was compared to the nominal range to assess the accuracy of the detector. To evaluate the robustness of the detector between each setup, the experiments were repeated on three different days. To evaluate the consistency of the measurements between deliveries, three sets of measurements were acquired for each experiment. Results: Using this geometric calibration procedure, the proton beam ranges measured using the liquid scintillator system were all within 0.3mm of the nominal range. The average difference between the measured and nominal ranges was −0.20mm. The delivery-to-delivery standard deviation of the proton range measurement was 0.04mm, and the setup-to-setup standard deviation of the measurement was 0.10mm. Conclusion: The liquid scintillator system can measure the range of all 94 beams in just two deliveries. With the proposed geometric calibration, it can measure proton range with sub-millimeter accuracy, and the measurements were shown to be consistent between deliveries and setups. Therefore, we conclude that the liquid scintillator system provides a reliable and convenient tool for proton range measurement. This project was supported in part by award number CA182450 from the National Cancer Institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The dilation aided single–line–of–sight x–ray camera for the National Ignition Facility: Characterization and fielding

Crystal x–ray imaging is commonly used in inertial confinement fusion and laser-plasma interaction applications as it has advantages compared to pinhole imaging, such as higher signal throughput, better achievable spatial resolution, and chromatic selection. Yet, currently used x–ray detectors are only able to obtain a single time resolved image per crystal. The dilation aided single–line–of–sight x–ray camera described here was designed for the National Ignition Facility (NIF) and combines two recent diagnostic developments, the pulse dilation principle used in the dilation x-ray imager and a ns–scale multi-frame camera that uses a hold and readout circuit for each pixel. This enables multiple images to be taken from a single–line–of–sight with high spatial and temporal resolution. Presently, the instrument can record two single–line–of–sight images with spatial and temporal resolution of 35 μm and down to 35 ps, respectively, with a planned upgrade doubling the number of images to four. Here we present the dilation aided single–line–of–sight camera for the NIF, including the x–ray characterization measurements obtained at the COMET laser, as well as the results from the initial timing shot on the NIF.

47 OTHER INSTRUMENTATION↗

Dawn Orbit Determination Team: Modeling and Fitting of Optical Data at Vesta

The Dawn spacecraft was launched on September 27th, 2007. Its mission is to consecutively rendezvous with and observe the two largest bodies in the main asteroid belt, Vesta and Ceres. It has already completed over a year's worth of direct observations of Vesta (spanning from early 2011 through late 2012) and is currently on a cruise trajectory to Ceres, where it will begin scientific observations in mid-2015. Achieving this data collection required careful planning and execution from all Dawn operations teams. Dawn's Orbit Determination (OD) team was tasked with reconstruction of the as-flown trajectory as well as determination of the Vesta rotational rate, pole orientation and ephemeris, among other Vesta parameters. Improved knowledge of the Vesta pole orientation, specifically, was needed to target the final maneuvers that inserted Dawn into the first science orbit at Vesta. To solve for these parameters, the OD team used radiometric data from the Deep Space Network (DSN) along with optical data reduced from Dawn's Framing Camera (FC) images. This paper will de-scribe the initial determination of the Vesta ephemeris and pole using a combination of radiometric and optical data, and also the progress the OD team has made since then to further refine the knowledge of Vesta's body frame orientation and rate with these data.

imagery↗

Point Cloud Based Approach to Stem Width Extraction of Sorghum

A revolution in the field of genomics has produced vast amounts of data and furthered our understanding of the genotypephenotype map, but is currently constrained by manually intensive or limited phenotype data collection. We propose an algorithm to estimate stem width, a key characteristic used for biomass potential evaluation, from 3D point cloud data collected by a robot equipped with a depth sensor in a single pass in a standard field. The algorithm applies a two step alignment to register point clouds in different frames, a Frangi filter to identify stemlike objects in the point cloud and an orientation based filter to segment out and refine individual stems for width estimation. Individually, detected stems which are split due to occlusions are merged and then registered with previously found stems in previous camera frames in order to track temporally. We then refine the estimates to produce an accurate histogram of width estimates per plot. Since the plants in each plot are genetically identical, distributions of the stem width per plot can be useful in identifying genetically superior sorghum for biofuels.

09 BIOMASS FUELS↗

Spectrally filtered fast imaging of internal magnetohydrodynamic activity in the DIII-D tokamak

The detailed poloidal structure of internal magnetohydrodynamic (MHD) modes is imaged using broadband visible bremsstrahlung emission from the core of the DIII-D tokamak. Spectral analysis of individual pixel time series recorded by a fast framing camera (up to 26 000 frames/s at 256x256 spatial resolution) is used to reconstruct two-dimensional images of mode amplitude. Application of this spectrally filtered fast imaging (SFFI) technique reveals spatially extended coherent structures that correspond to a (m,n)=(1,1) kink mode and a (2,1) neoclassical tearing mode rotating in the laboratory frame. The SFFI technique produces images with significantly less noise than images produced with the commonly used background subtraction method. Extension of SFFI to other core MHD events and coherent fluctuations in general is straightforward and could lead to further understanding of core MHD activity in fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗