Search NASA⌕ Search

SEARCH · Search NASA

Results for “freezing level”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Research and investigation of gas dynamic lasers

Chemical mixing laser investigations were conducted (1) to investigate the properties of a bimolecular exchange laser system pumped by the H + Cl2 yields HCl(v) + Cl reaction, initiated by arc-dissociated H2, with lasing occurring between wavelengths of 3.4 and 4.0 microns, and (2) to establish the feasibility of an atom recombination-transfer laser employing recombination of arc-dissociated nitrogen with subsequent transfer of vibrational energy to CO2 for lasing at 10.6 microns. One-dimensional analytical results indicate higher results should be obtained with up to v = 3 to 2 transitions participating. Diagnostic and analytical results show that the reaction mechanism during mixing, a back reaction of HCl(v) with H atoms, reaction of Cl with H2(v), moderately fast V-V, V-T processes, and possible HCl(o) initial contaminant level may explain the low performance. N2-CO2 thermal mixing laser studies were extended to measure the efficiency of transfer of recombination energy in such a nonequilibrium N2 source to 10.6 microns optical energy. The low level of efficiency suggests that V-T decay processes may prevent vibrational energy freezing until much lower temperatures are achieved and that trapping of energy in long-lived electronic excitation of N2 may be a factor.

Boedeker, L. R.↗

Sea ice - Multiyear cycles and white ice

The multiyear thickness cycles represent one of the interesting features of the sea ice studies performed by Semtner (1976) and Washington et al. (1976) with simple thermodynamic models of sea ice. In the present article, a description is given of results which show that the insulating effect of snow on the surface of the sea ice is important in producing these multiyear cycles given the physics included in the model. However, when the formation of white ice is included, the cycles almost disappear. White ice is the ice which forms at the snow-ice interface when the snow layer becomes thick enough to depress the ice below the water level. Water infiltrates the snow by coming through the ice at leads and generally freezes there, forming white ice.

Ledley, T. S.↗

Application of Satellite SAR Imagery in Mapping the Active Layer of Arctic Permafrost

A method of mapping the active layer of Arctic permafrost using a combination of conventional synthetic aperture radar (SAR) backscatter and more sophisticated interferometric SAR (INSAR) techniques is proposed. The proposed research is based on the sensitivity of radar backscatter to the freeze and thaw status of the surface soil, and the sensitivity of INSAR techniques to centimeter- to sub-centimeter-level surface differential deformation. The former capability of SAR is investigated for deriving the timing and duration of the thaw period for surface soil of the active layer over permafrost. The latter is investigated for the feasibility of quantitative measurement of frost heaving and thaw settlement of the active layer during the freezing and thawing processes. The resulting knowledge contributes to remote sensing mapping of the active layer dynamics and Arctic land surface hydrology.

Li, Shu-Sun↗

CO2 Snow on Mars and Early Earth: Experimental Constraints

Greenhouse warming due to carbon dioxide atmospheres may be responsible for maintaining the early Earth's surface temperature above freezing and may even have allowed for liquid water on early Mars. However, the high levels of CO2 required for such warming should have also resulted in the formation of CO2 clouds. These clouds, depending on their particle size, could lead to either warming or cooling. The particle size in turn is determined by the nucleation and growth conditions. Here we present laboratory studies of the nucleation and growth of carbon dioxide on water ice under Martian atmospheric conditions. We find that a critical saturation, S = 1.34, is required for nucleation, corresponding to a contact parameter between solid water and solid carbon dioxide of m = 0.95. We also find that after nucleation occurs, growth of CO2 is very rapid and proceeds without a surface kinetic barrier. Because growth would be expected to continue until the CO2 pressure is lowered to its vapor pressure, we expect particles larger than those being currently suggested for the present and past Martian atmospheres. Using this information in a microphysical model described in a companion paper, we find that CO2 clouds are best described as "snow", having a relatively small number of large particles.

Glandorf, David L.↗

FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D

Astronauts lose 1.0 to 1.5% of their bone mass per month on long-duration spaceflights. NASA wishes to monitor the bone loss onboard spacecraft to develop nutritional and exercise countermeasures, and make adjustments during long space missions. On Earth, the same technology could be used to monitor osteoporosis and its therapy. Aptamers bind to targets against which they are developed, much like antibodies. However, aptamers do not require animal hosts or cell culture and are therefore easier, faster, and less expensive to produce. In addition, aptamers sometimes exhibit greater affinity and specificity vs. comparable antibodies. In this work, fluorescent dyes and quenchers were added to the aptamers to enable pushbutton, one-step, bind-and-detect fluorescence resonance energy transfer (FRET) assays or tests that can be freeze-dried, rehydrated with body fluids, and used to quantitate bone loss of vitamin D levels with a handheld fluorometer in the spacecraft environment. This work generated specific, rapid, one-step FRET assays for the bone loss marker C-telopeptide (CTx) when extracted from urine, creatinine from urine, and vitamin D congeners in diluted serum. The assays were quantified in nanograms/mL using a handheld fluorometer connected to a laptop computer to convert the raw fluorescence values into concentrations of each analyte according to linear standard curves. DNA aptamers were selected and amplified for several rounds against a 26- amino acid form of CTx, creatinine, and vitamin D. The commonalities between loop structures were studied, and several common loop structures were converted into aptamer beacons with a fluorophore and quencher on each end. In theory, when the aptamer beacon binds its cognate target (CTx bone peptide, creatinine, or vitamin D), it is forced open and no longer quenched, so it gives off fluorescent light (when excited) in proportion to the amount of target present in a sample. This proportional increase in fluorescence is called a "lights on" FRET response. The vitamin D aptamer beacon gives a "lights off" or inversely proportional fluorescence response to the amount of vitamin D present in diluted serum. These FRET-aptamer assays are rapid (<30 minutes), sensitive (low ng/mL detection limits), and quite easy to carry out (add sample, mix, and detect in the handheld reader). Benefits include the speed of the assays as well as the small amount of space taken up by the handheld reader and cuvette assays. The aptamer DNA sequences represent novel additional features of the existing (patent-pending) FRET-aptamer assay platform.

Bruno, John G.↗

Impact Delivery of Reduced Greenhouse Gases on Early MARS

While there is abundant evidence for flowing liquid water on the ancient Martian surface, a widely accepted greenhouse mechanism for explaining this in the presence of a faint young sun has yet to emerge. Gases such as NH3, CO2 alone, SO2, clouds, and CH4, have sustainability issues or limited greenhouse power. Recently, Ramirez et al. proposed that CO2-H2 atmospheres, through collision induced absorptions (CIA), could solve the problem if large amounts are present (1.3-4 bars of CO2, 50-20% H2). However, they had to estimate the strength of the H2- CO2 interaction from the measured strength of the H2- N2 interaction. Recent ab initio calculations show that the strength of CO2-H2 CIA is greater than Ramirez et al. assumed. Wordsworth et al. also calculated the absorption coefficients for CO2-CH4 CIA and show that on early Mars a 0.5 bar CO2 atmosphere with percent levels of H2 or CH4 can raise mean annual temperatures by tens of degrees Kelvin. Freezing temperatures can be reached in atmospheres containing 1-2 bars of CO2 and 2-10% H2 and CH4. The new work demonstrates that less CO2 and reduced gases are needed than Ramirez et al. originally proposed, which improves prospects for their hypothesis. If thick weakly reducing atmospheres are the solution to the faint young sun paradox, then plausible mechanisms must be found to generate and sustain the required concentrations of H2 and CH4. Possible sources of reducing gases include volcanic outgassing, serpentinization, and impact delivery; sinks include photolysis, oxidation, and hydrogen escape. The viability of the reduced greenhouse hypothesis depends, therefore, on the strength of these sources and sinks.

Martian surface↗

Freeze Casting of LAGP for 3D Textured Solid-State Structural Electrolytes

In this study, all-solid-state structural lithium-ion batteries, a type of load bearing electrochemical energy storage that provides systems-level weight savings is being pursued for the realization of inherently safe next generation hybrid-electric and all-electric green aerospace propulsion systems. Currently investigated all-solid-state batteries do not meet the requirements for specific power and mechanical stability. To address these issues, freeze casting of lithium aluminum germanium phosphate (LAGP) electrolyte material has been explored for the creation of a textured 3D electrolyte scaffold with large interfacial surface area for high power discharge and hierarchical porosity for accommodation of active material volume changes during electrochemical cycling. We report the effects of freeze casting processing parameters on the microstructural development and mechanical performance of the scaffolds, characterized through scanning electron microscopy and ring-on-ring mechanical testing. Slurry composition and casting parameters such as solids loading, casting speed, tape angle, and temperature gradients have been modified to determine the impact on density, lamellar morphology, and final load-bearing performance.

ceramics↗

Evidence for the Widespread Presence of Liquid-Phase Particles During the 1999-2000 Arctic Winter

In-situ Multi-Angle Spectrometer Probe (MASP) particle measurements have been analyzed to determine the typical behaviour of sulphate particles during the SOLVE campaign. The analysis has focussed on variations in the total particle concentration measured by MASP, which is a diagnostic that is primarily sensitive to the growth of small particles (those which are initially smaller than 0.2 micrometers in radius). At all levels of the stratosphere, the total MASP concentration varies continuously with temperature. This behaviour is well-reproduced by assuming that the sulphate aerosols are liquid ternary solutions, but cannot be reproduced if the aerosol is assumed to be frozen. This liquid-like behaviour is apparent for all measurements made during SOLVE, both inside and outside the vortex, and even at the coldest temperatures sampled during the campaign. The only anomalous measurements were made during the flight of January 14th, 2001; however, this midlatitude flight is very unlikely to contain SAT particles based on the recent warm temperatures experienced by the air. At the levels with the coldest measured temperatures, at least 90% of the particles grow as liquids. Therefore, the freezing that occurred during the 1999-2000 Arctic winter was selective, causing most of the particles to remain liquid even in the presence of a small number of frozen particles.

Drdla, K↗

Use of electron microprobe x-ray analysis for determination of low calcium concentrations across leaves deficient in calcium

An electron microprobe with wavelength-dispersive x-ray spectrometry (WDS) was found to be useful for the determination of Ca concentrations in leaf tissue deficient in Ca. WDS effectively detected Ca concentrations as low as 0.2 mg/g dry wt in the presence of high levels of K and Mg (120 and 50 mg/g dry wt, respectively). Leaf specimens were prepared for analysis by quick-freezing in liquid nitrogen and freeze-drying at -20 degrees C to maintain elemental integrity within the tissue. Because dry material was analyzed, sample preparation was simple and samples could be stored for long periods before analysis. A large beam diameter of 50 gm was used to minimize tissue damage under the beam and analyze mineral concentrations within several cells at one time. Beam penetration was between 50 and 55 microns, approximately one-third of the thickness of the leaf. For analysis of concentrations in interveinal areas, analyses directed into the abaxial epidermis were found most useful. However, because of limited beam penetration, analyses of veinal areas would require use of cross sections [correction of crosssections]. Solid mineral standards were used for instrument standardization. To prevent measurement errors resulting from differences between the matrix of the mineral standards and the analyzed tissue, concentrations in leaves were corrected using gelatin standards prepared and analyzed under the same conditions. WDS was found to be useful for documenting that very low Ca levels occur in specific areas of lettuce leaves exhibiting the Ca deficiency injury termed tipburn.

Non-NASA Center↗

Controlled freezing of biological samples

Apparatus consists of thermocouple connected to semiconductor reference junction. Junction is connected to amplifier that boosts signal by 1,000. High-level signal is displayed on recorder and fed into second amplifier where it is compared with signal from potentiometer of programmed dc reference in bag-temperature programer. Difference in signals indicates output voltage. Remaining circuitry provides zero-phase, time-proportion control of heaters such that heater power is directly proportional to error signal.

Cygnarowicz, T. A.↗

Water Phase Change Heat Exchanger System Level Analysis for Low Lunar Orbit

In low Lunar orbit (LLO) the thermal environment is cyclic - extremely cold in the eclipse and as warm as room temperature near the subsolar point. Phase change material heat exchangers (PCHXs) are the best option for long term missions in these environments. The Orion spacecraft will use a n-pentadecane wax PCHX for its envisioned mission to LLO. Using water as a PCM material is attractive because its higher heat of fusion and greater density result in a lighter, more compact PCHX. To assess the use of a water PCHX for a human spacecraft in a circular LLO, a system level analysis was performed for the Orion spacecraft. Three cases were evaluated: 1) A one-to-one replacement of the wax PCHX on the internal thermal control loop with a water PCHX (including the appropriate control modifications), 2) reducing the radiator return setpoint temperature below Orion's value to enhance PCHX freezing, and 3) placing the water PCM on the external loop. The model showed that the water PCHX could not be used as a drop-in replacement for the wax PCHX. It did not freeze fully during the eclipse owing to its low freezing point. To obtain equivalent performance, 40% more radiator area than the Orion baseline was required. The study shows that, although water PCHXs are attractive at a component level, system level effects mean that they are not the best choice for LLO.

Navarro, Moses↗

A Daily Surface Melt Product From Passive Microwave Swath Observations for Arctic Sea Ice Studies

Most passive microwave sea ice data products are produced with daily gridded brightness temperatures. However, a single polar-orbiting passive microwave instrument makes many measurements per day where swaths overlap in the polar regions. These level 1 swath brightness temperature observations can be used to derive information on sub-daily sea ice processes. One such process is the rapid transition of snow and ice between freezing and melting due to diurnal freeze-thaw cycling or brief warming events in the pre-melt season. Here, a new method utilizing the sub-daily variability in swath-to-swath observations is used to produce daily, binary maps of the melting status on Arctic Sea ice using Level 1C brightness temperatures from the Special Sensor Microwave Imager and Sounder (SSM/I-SSMIS) data record. The resulting data set will enable investigations of the frequency, inter-annual variability, and spatial extent of brief surface melting events occurring in the winter and shoulder seasons outside of the traditional summer melt season.

Angela C. Bliss↗

Space Shuttle Propulsion Finishing Strong

Numerous lessons have been documented from the Space Shuttle Propulsion elements. Major events include loss of the SRB's on STS-4 and shutdown of an SSME during ascent on STS- 51F. On STS-112 only half the pyrotechnics fired to release the vehicle from the launch pad, a testament for redundancy. STS-91 exhibited freezing of a main combustion chamber pressure measurement and on STS-93 nozzle tube ruptures necessitated a low liquid level oxygen cut off of the main engines. A number of on pad aborts were experienced during the early program resulting in delays. And the two accidents, STS-51L and STS-107, had unique heritage in history from early Program decisions and vehicle configuration. Following STS-51L significant resources were invested in developing fundamental physical understanding of solid rocket motor environments and material system behavior. Human rating of solid rocket motors was truly achieved. And following STS-107, the risk of ascent debris was better characterized and controlled. Situational awareness during all mission phases improved, and the management team instituted effective risk assessment practices. These major events and lessons for the future are discussed. The last 22 flights of the Space Shuttle, following the Columbia accident, were characterized by remarkable improvement in safety and reliability. Numerous problems were solved in addition to reduction of the ascent debris hazard. The propulsion system elements evolved to high reliability and heavy lift capability. The Shuttle system, though not a operable as envisioned in the 1970's, successfully assembled the International Space Station (ISS) and provided significant logistics and down mass for ISS operations. By the end of the Program, the remarkable Space Shuttle Propulsion system achieved very high performance, was largely reusable, exhibited high reliability, and is a heavy lift earth to orbit propulsion system. The story of this amazing system is discussed in detail in the paper.

Owen, James W.↗

Shuttle Propulsion System Major Events and the Final 22 Flights

Numerous lessons have been documented from the Space Shuttle Propulsion elements. Major events include loss of the Solid Rocket Boosters (SRB's) on STS-4 and shutdown of a Space Shuttle Main Engine (SSME) during ascent on STS-51F. On STS-112 only half the pyrotechnics fired during release of the vehicle from the launch pad, a testament for redundancy. STS-91 exhibited freezing of a main combustion chamber pressure measurement and on STS-93 nozzle tube ruptures necessitated a low liquid level oxygen cut off of the main engines. A number of on pad aborts were experienced during the early program resulting in delays. And the two accidents, STS-51L and STS-107, had unique heritage in history from early program decisions and vehicle configuration. Following STS-51L significant resources were invested in developing fundamental physical understanding of solid rocket motor environments and material system behavior. And following STS-107, the risk of ascent debris was better characterized and controlled. Situational awareness during all mission phases improved, and the management team instituted effective risk assessment practices. The last 22 flights of the Space Shuttle, following the Columbia accident, were characterized by remarkable improvement in safety and reliability. Numerous problems were solved in addition to reduction of the ascent debris hazard. The Shuttle system, though not as operable as envisioned in the 1970's, successfully assembled the International Space Station (ISS). By the end of the program, the remarkable Space Shuttle Propulsion system achieved very high performance, was largely reusable, exhibited high reliability, and was a heavy lift earth to orbit propulsion system. During the program a number of project management and engineering processes were implemented and improved. Technical performance, schedule accountability, cost control, and risk management were effectively managed and implemented. Award fee contracting was implemented to provide performance incentives. The Certification of Flight Readiness and Mission Management processes became very effective. A key to the success of the propulsion element projects was related to relationships between the MSFC project office and support organizations with their counterpart contractor organizations. The teams worked diligently to understand and satisfy requirements and achieve mission success.

Owen, James W.↗

Characteristics and Origins of Frontal Convection During IMPACTS on 25 January 2020

This presentation will discuss the characteristics of frontal convection and its estimation from the ER-2 multifrequency nadir reflectivity and Doppler velocity from a warm-occlusion frontal system that traversed across the Northeast U.S. on 25 January 2020. This system that occurred during the IMPACTS field deployment, brought widespread clouds and precipitation to the Northeast. The system brought primarily rain in most areas of more intense rainfall associated with embedded convection near the frontal band and some freezing rain and/or snowfall in the northern regions or higher terrain due to the pre-existing low-level cold air. The NASA ER-2 instrumented with multifrequency radar and the NASA P-3 with in situ microphysics measurements both collected data from this system. The focus of this presentation is on the estimation of vertical velocity in convective and non-convective regions using the ER-2 nadir Doppler measurements. Vertical velocities are inherently difficult to estimate in frontal systems at mesoscale and below other than from direct in situ measurement because of their small magnitudes and errors in the measurements. Estimates from nadir Doppler measurements such as from the ER-2 are challenging because of both Doppler velocity uncertainties and the need to estimate particle fallspeed since the Doppler measurement is the vertical velocity plus the hydrometeor fallspeed. In the presentation, the vertical velocity estimation, its associated errors, and a possible mitigation scheme are described. The characteristics of the convective and stratiform regions on 25 January 2020 are discussed. The vertical velocity estimated from the nadir Doppler measurements are compared with P-3 in situ measurements. Estimation of vertical velocity is one of the goals for upcoming spaceborne missions such as EarthCare and ACCP.

Gerald M. Heymsfield↗

Irrigation scheduling, freeze warning and soil salinity detecting

The author has identified the following significant results. Correlations of multispectral scanner (MSS) digital data differences between vegetated and bare soil areas with salinity levels from the eight saline areas using MSS bands seven and ten in the infrared region were significant. Correlations were derived for Cameron County, Texas. Detection of saline soils may be possible, using either film density readings or multispectral scanner data, when the lower reflectance of vegetation on highly saline soil and the higher reflectance of vegetation on lower saline soil are considered by using film on MSS contrasts between vegetation and bare soil.

Wiegand, C. L.↗

The Safe Removal of Frozen Air from the Annulus of an LH2 Storage Tank

Large Liquid Hydrogen (LH2) storage tanks are vital infrastructure for NASA. Eventually, air may leak into the evacuated and perlite filled annular region of these tanks. Although the vacuum level is monitored in this region, the extremely cold temperature causes all but the helium and neon constituents of air to freeze. A small, often unnoticeable pressure rise is the result. As the leak persists, the quantity of frozen air increases, as does the thermal conductivity of the insulation system. Consequently, a notable increase in commodity boil-off is often the first indicator of an air leak. Severe damage can result from normal draining of the tank. The warming air will sublimate which will cause a pressure rise in the annulus. When the pressure increases above the triple point, the frozen air will begin to melt and migrate downward. Collection of liquid air on the carbon steel outer shell may chill it below its ductility range, resulting in fracture. In order to avoid a structural failure, as described above, a method for the safe removal of frozen air is needed. A thermal model of the storage tank has been created using SINDA/FLUINT modeling software. Experimental work is progressing in an attempt to characterize the thermal conductivity of a perlite/frozen nitrogen mixture. A statistical mechanics model is being developed in parallel for comparison to experimental work. The thermal model will be updated using the experimental/statistical mechanical data, and used to simulate potential removal scenarios. This paper will address methodologies and analysis techniques for evaluation of two proposed air removal methods.

cryogenic insulation↗

Analysis of Seed Sanitization, Rapid Freezer Proficiency, and Veg-03 Water Verification

In order to ensure the well-being of astronauts and experiments on the ISS (International Space Station), seeds need to be free of microbes, the rapid freezer needs to be freezing biological samples evenly and proficiently, and the astronauts need to have accurate watering procedures for Veg-03 (the latest Phytotron for the Veggie (Vegetable Production System) project). Seed flight candidates were sanitized with varying levels of HCL in order to determine the right amount to use for future flight experiments, too much HCL and the seeds will not germinate and too little and they will be contaminated with microorganisms. The rapid freezer was assessed using temperature probes to determine if there is a homogeneous change in temperature in order to ensure the safe freezing of biological organisms. The plant watering procedures given to the astronauts were assessed in order to make sure that Veg-03 experiments are receiving the correct amount of water.

Hollingsworth, Savannah↗