Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency combs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Coherence revivals in two-photon frequency combs

We describe and theoretically analyze the self-imaging Talbot effect of entangled photon pairs in the time domain. Rich phenomena are observed in coherence propagation along dispersive media of mode-locked two-photon states with frequency entanglement exhibiting a comblike correlation function. Our results can be used to remotely transfer frequency standards through optical fiber networks with two-photon light, avoiding the requirement of dispersion compensation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Selection and amplification of a single optical frequency comb mode for laser cooling of the strontium atoms in an optical clock

In this paper, we report on the active filtering and amplification of a single mode from an optical femtosecond laser comb with mode spacing of 250 MHz by optical injection of two external-cavity diode lasers operating in cascade to build a narrow linewidth laser for laser cooling of the strontium atoms in an optical lattice clock. Despite the low injection of individual comb mode of approximately 50 nW, a single comb line at 689 nm could be filtered and amplified to reach as high as 10 mW with 37 dB side mode suppression and a linewidth of 240 Hz. This method could be applied over a broad spectral band to build narrow linewidth lasers for various applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrabroadband coherent supercontinuum frequency comb

We present detailed studies of the coherence properties of an ultrabroadband supercontinuum, enabled by a comprehensive approach involving continuous-wave laser sources to independently probe both the amplitude and phase noise quadratures across the entire spectrum. The continuum coherently spans more than 1.5 octaves, supporting Hz-level comparison of ultrastable lasers at 698 nm and 1.54 {mu}m. We present a complete numerical simulation of the accumulated comb coherence in the limit of many pulses, in contrast to the single-pulse level, with systematic experimental verification. The experiment and numerical simulations reveal the presence of quantum-seeded broadband amplitude noise without phase coherence degradation, including the discovery of a dependence of the supercontinuum coherence on the fiber fractional Raman gain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reply to ''Comment on 'Modal expansion approach to optical-frequency-comb generation with monolithic whispering-gallery-mode resonators'''

In a Comment [Deych, Phys. Rev. A 84, 017801 (2011)] on our recent article [Chembo and Yu, Phys. Rev. A 82, 033801 (2010)] on Kerr comb generation in monolithic whispering-gallery-mode (WGM) resonators, the author claims that even though our main results ''remain intact'', the framework of our analysis contains some mathematical errors. In this Reply, we demonstrate that the author's criticisms and his alternative theory are incorrect, and that all the disagreeing claims come from the author's misunderstanding of the physical system under investigation. In particular, the main conceptual error in the Comment is the confusion between evanescent and radiative coupling mechanisms for WGM resonators (in terms of Q factor, this is in our case a confusion between {approx}10{sup 9} and {approx}10{sup 2000}, respectively). This essential misconception leads for example the author to introduce a nonphysical {approx}10{sup 2000} multiplicative correction factor for the laser pump power. We show in this Reply that our WGM resonators are radiatively closed (because of the quasi-infinite radiative Q factor), so that the Mie scattering formalism proposed by Deych, which relies on radiative coupling, can only lead to erroneous results. We also show that the modal expansion approach in our original paper is appropriate, and all our approximations are physically well justified. We therefore stand by our modeling results, which are moreover in excellent agreement with the experiments reported in [Chembo, Strekalov, and Yu, Phys. Rev. Lett. 104, 103902 (2010)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated tuning of a ring-assisted MZI-based interleaver for Kerr frequency combs

We demonstrate a compact ring-assisted Mach–Zehnder interferometer (RAMZI)-based silicon photonic interleaver with a 400 GHz free spectral range (FSR), featuring flat passbands exceeding a spectral range of 50 nm. Additionally, we introduce a novel, to the best of our knowledge, add-on structure and tuning method enabling automated compensation for fabrication imperfections, precise shaping of the RAMZI flat-top passbands, and alignment with Kerr comb lines. Experimental results have shown successful interleaving of eight channels of distributed-feedback (DFB) lasers as well as a 200 GHz Kerr comb, both achieving an extinction ratio of approximately 20 dB.

Wang, Songli (ORCID:0009000626380795)↗

Dual-frequency-comb UV spectroscopy with one million resolved comb lines

We present high-resolution dual-comb spectroscopy across two broad UV spectral regions spanning 372–410 nm and 325–342 nm. This is achieved by generating sixth and seventh harmonics, respectively, from a low-noise 2.35 µm Cr:ZnS dual-comb laser system. The sixth harmonic band contains approximately 1,000,000 spectrally resolved comb lines, while the seventh harmonic band—around 550,000 comb lines. With the line spacing of 80 MHz, this corresponds to a resolving power of up to 10 million, offering remarkable spectral resolution.

Muraviev, Andrey↗

Intercomparison of open-path trace gas measurements with two dual-frequency-comb spectrometers

Abstract. We present the first quantitative intercomparison between two open-path dual-comb spectroscopy (DCS) instruments which were operated across adjacent 2 km open-air paths over a 2-week period. We used DCS to measure the atmospheric absorption spectrum in the near infrared from 6023 to 6376 cm−1 (1568 to 1660 nm), corresponding to a 355 cm−1 bandwidth, at 0.0067 cm−1 sample spacing. The measured absorption spectra agree with each other to within 5 × 10−4 in absorbance without any external calibration of either instrument. The absorption spectra are fit to retrieve path-integrated concentrations for carbon dioxide (CO2), methane (CH4), water (H2O), and deuterated water (HDO). The retrieved dry mole fractions agree to 0.14 % (0.57 ppm) for CO2, 0.35 % (7 ppb) for CH4, and 0.40 % (36 ppm) for H2O at ∼ 30 s integration time over the 2-week measurement campaign, which included 24 °C outdoor temperature variations and periods of strong atmospheric turbulence. This agreement is at least an order of magnitude better than conventional active-source open-path instrument intercomparisons and is particularly relevant to future regional flux measurements as it allows accurate comparisons of open-path DCS data across locations and time. We additionally compare the open-path DCS retrievals to a World Meteorological Organization (WMO)-calibrated cavity ring-down point sensor located along the path with good agreement. Short-term and long-term differences between the open-path DCS and point sensor are attributed, respectively, to spatial sampling discrepancies and to inaccuracies in the current spectral database used to fit the DCS data. Finally, the 2-week measurement campaign yields diurnal cycles of CO2 and CH4 that are consistent with the presence of local sources of CO2 and absence of local sources of CH4.

Waxman, Eleanor M.↗