Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency scan testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Performance evaluation of a kinesthetic-tactual display

Simulator studies demonstrated the feasibility of using kinesthetic-tactual (KT) displays for providing collective and cyclic command information, and suggested that KT displays may increase pilot workload capability. A dual-axis laboratory tracking task suggested that beyond reduction in visual scanning, there may be additional sensory or cognitive benefits to the use of multiple sensory modalities. Single-axis laboratory tracking tasks revealed performance with a quickened KT display to be equivalent to performance with a quickened visual display for a low frequency sum-of-sinewaves input. In contrast, an unquickened KT display was inferior to an unquickened visual display. Full scale simulator studies and/or inflight testing are recommended to determine the generality of these results.

Jagacinski, R. J.↗

Effect of a growth hormone treatment on bone orthotropic elasticity in dwarf rats

A refinement of the current ultrasonic elasticity technique was used to measure the orthotropic elastic properties of rat cortical bone as well as to quantify changes in elastic properties, density, and porosity of the dwarf rat cortex after a treatment with recombinant human growth hormone (rhGH). The ultrasonic elasticity technique was refined via optimized signal management of high-frequency wave propagation through cubic cortical specimens. Twenty dwarf rats (37 days old) were randomly assigned to two groups (10 rats each). The dwarf rat model (5-10% of normal GH) was given subcutaneous injections of either rhGH or saline over a 14-day treatment period. Density was measured using Archimedes technique. Porosity and other microstructural characteristics were also explored via scanning electron microscopy and image analysis. Statistical tests verified significant decreases in cortical orthotropic Young's (-26.7%) and shear (-16.7%) moduli and density (-2.42%) concomitant with an increase in porosity (+125%) after rhGH treatments to the dwarf model (p < 0.05). A change in material symmetry from orthotropy toward planar isotropy within the radial-circumferential plane after GH treatments was also noted. These results demonstrate some alteration in bone properties at this time interval. Structural implications of these changes throughout physiological loading regimens should be explored.

NASA Discipline Musculoskeletal↗

NASA Tech Briefs, September 2011

Topics covered include: Fused Reality for Enhanced Flight Test Capabilities; Thermography to Inspect Insulation of Large Cryogenic Tanks; Crush Test Abuse Stand; Test Generator for MATLAB Simulations; Dynamic Monitoring of Cleanroom Fallout Using an Air Particle Counter; Enhancement to Non-Contacting Stress Measurement of Blade Vibration Frequency; Positively Verifying Mating of Previously Unverifiable Flight Connectors; Radiation-Tolerant Intelligent Memory Stack - RTIMS; Ultra-Low-Dropout Linear Regulator; Excitation of a Parallel Plate Waveguide by an Array of Rectangular Waveguides; FPGA for Power Control of MSL Avionics; UAVSAR Active Electronically Scanned Array; Lockout/Tagout (LOTO) Simulator; Silicon Carbide Mounts for Fabry-Perot Interferometers; Measuring the In-Process Figure, Final Prescription, and System Alignment of Large; Optics and Segmented Mirrors Using Lidar Metrology; Fiber-Reinforced Reactive Nano-Epoxy Composites; Polymerization Initiated at the Sidewalls of Carbon Nanotubes; Metal-Matrix/Hollow-Ceramic-Sphere Composites; Piezoelectrically Enhanced Photocathodes; Iridium-Doped Ruthenium Oxide Catalyst for Oxygen Evolution; Improved Mo-Re VPS Alloys for High-Temperature Uses; Data Service Provider Cost Estimation Tool; Hybrid Power Management-Based Vehicle Architecture; Force Limit System; Levitated Duct Fan (LDF) Aircraft Auxiliary Generator; Compact, Two-Sided Structural Cold Plate Configuration; AN Fitting Reconditioning Tool; Active Response Gravity Offload System; Method and Apparatus for Forming Nanodroplets; Rapid Detection of the Varicella Zoster Virus in Saliva; Improved Devices for Collecting Sweat for Chemical Analysis; Phase-Controlled Magnetic Mirror for Wavefront Correction; and Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics.

Source record↗

Concept Design of a Multi-Band Shared Aperture Reflectarray/Reflector Antenna

A scalable dual-band (KaW) shared-aperture antenna system design has been developed as a proposed solution to meet the needs of the planned NASA Earth Science Aerosol, Clouds, and Ecosystem (ACE) mission. The design is comprised of a compact Cassegrain reflector/reflectarray with a fixed pointing W-band feed and a cross track scanned Ka-band Active Electronically Scanned Array (AESA). Critical Sub-scale prototype testing and flight tests have validated some of the key aspects of this innovative antenna design, including the low loss reflector/reflectarray surface.More recently the science community has expressed interest in a mission that offers the ability to measure precipitation in addition to clouds and aerosols. In this paper we present summaries of multiple designs that explore options for realizing a tri-frequency (KuKaW), shared-aperture antenna system to meet these science objectives. Design considerations include meeting performance requirements while emphasizing payload size, weight, prime power, and cost. The extensive trades and lessons learned from our previous dual-band ACE system development were utilized as the foundation for this work.

Doppler↗

Concept Design of a Multi-Band Shared Aperture Reflectarray/Reflector Antenna

A scalable dual-band (Ka/W) shared-aperture antenna system design has been developed as a proposed solution to meet the needs of the planned NASA Earth Science Aerosol, Clouds, and Ecosystem (ACE) mission. The design is comprised of a compact Cassegrain reflector/reflectarray with a fixed pointing W-band feed and a cross track scanned Ka-band Active Electronically Scanned Array (AESA). Critical Sub-scale prototype testing and flight tests have validated some of the key aspects of this innovative antenna design, including the low loss reflector/reflectarray surface. More recently the science community has expressed interest in a mission that offers the ability to measure precipitation in addition to clouds and aerosols. In this paper we present summaries of multiple designs that explore options for realizing a tri-frequency (Ku/Ka/W), shared-aperture antenna system to meet these science objectives. Design considerations include meeting performance requirements while emphasizing payload size, weight, prime power, and cost. The extensive trades and lessons learned from our previous dual-band ACE system development were utilized as the foundation for this work.

doppler↗

Evaluating the Utility of Pressure Scanners for Unsteady Pressure Measurements in Wind Tunnel Characterization of the Space Launch System

In many aerodynamic measurement applications, the ability to make time-accurate measurements with pressure scanners provides practical advantages over making the same measurements directly using flush-mounted transducers. The pneumatic distortion due to the tubing between the sensing module and surface port limits the usefulness of such measurements to averaged, steady data only. This issue has restricted the application of pressure scanners for unsteady pressure measurements in wind tunnel and flight-testing applications. The Wiener-filtered inverse system response model has been proven to be effective in reconstructing complex unsteady pressure signals acquired remotely using pressure scanners. In this work, the feasibility of using pressure scanning systems for time-resolved pressure measurements in the NASA Langley 14- by 22-Foot Subsonic Wind Tunnel was evaluated. Results demonstrated good agreement between the reference transducers and reconstructed pressure scanner measurements up to frequencies of approximately 500 Hz.

Unsteady pressure↗

Pultrusion Process Development for Long Space Boom Model

Long flexible-boom models were required to develop ground-vibration test methods for very-low-frequency space structures with applications to the proposed Space Station. Pultruded quasi-isotropic composite beams were selected as an option over extruded aluminum alloy structures because of the lower cost potential, the higher specific strength, the flexural properties, and the dynamic similarity considerations. The reinforcement material that was used was biaxial (0 deg/90 deg) fiberglass roving held in place with knitted polyester yarn such that equal fiber volume in 0 deg and 90 deg orientations provided nearly equal strength in both longitudinal and transverse directions. An isophthalic polyester resin system was used as the matrix. Continuous lengths up to 270 ft were easily pultruded with biaxial fabric. Tracking problems were encountered with similar unidirectional fabrics. Analyses of processing problems were conducted to determine causes for delamination, scaling, and sloughing. Ultrasonic C-scanning and scanning electron microscope examinations were conducted as well as mechanical testing to failure. Test results indicate that pultrusion processes can be used to produce quasi-isotropic composite structures.

Wilson, Maywood L.↗

Application of Radon Transform to Multi-Angle Measurements Made by the Research Scanning Polarimeter: A New Approach to Cloud Tomography. Part I: Theory and Tests on Simulated Data.

The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP was a prototype for the Aerosol Polarimetry Sensor (APS) launched on-board the NASA Glory satellite. Currently the retrieval algorithms developed for the RSP are being adopted for the measurements of the space-borne polarimeters on the upcoming NASA’s Plankton, Aerosol, Cloud Ocean Ecosystem (PACE)satellite mission. The RSP’s uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid water cloud droplet sizes using the polarized rainbow structure. It also provides geometric constraints on the cumulus cloud’s 2D cross section yielding the cloud’s geometric shape estimates. In this study we further build on the latter technique to develop a new tomographic approach to retrieval of cloud internal structure from remote sensing measurements. While tomography in the strict definition is a technique based on active measurements yielding a tomogram (directional optical thickness as a function of angle and offset of the view ray), we developed a “semi-tomographic” approach in which tomogram of the cloud is estimated from passive observations instead of being measured directly. This tomogram is then converted into 2D spatial distribution of the extinction coefficient using inverse Radon transform (filtered back projection) which is the standard tomographic procedure used e.g., in medical CT scans. This algorithm is computationally inexpensive compared to techniques relying on highly-multi-dimensional least-square fitting; it does not require iterative 3D RT simulations. The resulting extinction distribution is defined up to an unknown constant factor, so we discuss the ways to calibrate it using additional independent measurements. In the next step we use the profile of the droplet size distribution parameters from the cloud’s side (derived by fitting the polarized rainbows) to convert the 2D extinction distribution into that of the droplet number concentration. We illustrate and validate the proposed technique using 3D-RT-simulatedRSP observations of a LES-generated Cu cloud. Quantitative comparisons between the retrieved and the original optical and microphysical parameters are presented.

clouds↗

Surface finish quality of the outer AXAF mirror pair based on X-ray measurements of the VETA-I

We employ the X-ray measurements of the VETA-I taken at the X-Ray Calibration Facility (XRCF) of the Marshall Space Flight Center (MSFC) to extract information about the surface finish quality of the outermost pair of AXAF mirrors. The particular measurements we consider are 1D scans of the core of the point response function (PRF) (FWHM scans), the encircled energy as a function of radius, and 1D scans of the wings of the PRF. We discuss briefly our raytrace model which incorporates the numerous effects present in the VETA-I test, such as the finite source distance, the size and shape of the X-ray source, the residual gravitational distortions of the optic, the despace of the VETA-I, and particulate contamination. We show how the data constrain the amplitude of mirror surface deviations for spatial frequencies greater than about 0.1/mm. Constraints on the average amplitude of circumferential slope errors are derived as well.

Hughes, John P.↗

An Overview of MODIS Calibration and Characterization and Lessons Learned

The Moderate Resolution Imaging Spectroradiometer (MODIS) is a key instrument for NASA's EOS missions. Two nearly identical copies have flown on the Terra and Aqua spacecraft for more than 9 years and 6 years since their launch in December 1999 and May 2002, respectively. MODIS observations and associated data products have been widely used by the science community and users worldwide for studies of Earth's system of land, oceans, and atmosphere. MODIS was developed based on the desire of the science community to extend and enhance heritage sensors' data records. It was designed with enhancements made over its heritage sensors in terms of its spectral, spatial, and radiometric characteristics. It is a cross-track scanning radiometer, that uses a two-sided scan mirror, collecting data in 36 spectral bands covering spectral regions of visible (VIS), near-infrared (NIR), short-wave infrared (SWIR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). The VIS, NIR, and SWIR bands (bands 1-19 and 26), which make measurements of daytime surface reflected radiances, are referred to as the reflective solar bands (RSB). The MWIR and LWIR bands (20-25 and 27-36), which measure both the daytime and nighttime scene emissive radiances, are thus referred to as the thermal emissive bands (TEB). In this paper, we provide an overview of MODIS instrument calibration and characterization methodologies, activities, and results from pre-launch to post launch, with emphasis on the lessons learned from its design to on-orbit operation. Currently, both instruments are operated normally and all the on-orbit calibration activities are performed on a regular basis with some at slightly reduced frequencies. The TEB responses have been extremely stable with less than 0.3% change per year. For the RSB, the changes are wavelength and scan angle dependent with the largest changes in the VIS spectral bands. As both Terra and Aqua MODIS continue to operate beyond their prime missions, constant effort is still needed to maintain instrument and calibration and data product quality. This paper shows that the lessons from Terra MODIS design, test, and operation, have greatly benefitted Aqua MODIS. Because of this, Aqua MODIS overall performance is better than Terra MODIS. It is not surprising that lessons from MODIS calibration and characterization, from methodologies to on-orbit implementation, have also provided valuable information for the design and development of future earth observing missions/sensors, such as VHRS on the NPP and NPOESS, ABI on GOES-R, OLI on LDCM, and the reflective solar sensor on CLARREO.

Xiong, Xiaxiong↗

Surface finish quality of the outer AXAF mirror pair based on x ray measurements of the VETA-I

We employ the X-ray measurements of the VETA-I taken at the X-Ray Calibration Facility (XRCF) of the Marshall Space Flight Center (MSFC) to extract information about the surface finish quality of the outermost pair of AXAF mirrors. The particular measurements we consider are one dimensional scans of the core of the point response function (PRF) (full width half maximum (FWHM) scans), the encircled energy as a function of radius, and one dimensional scans of the wings of the PRF. We discuss briefly our ray trace model which incorporates the numerous effects present in the VETA-I test, such as the finite source distance, the size and shape of the X-ray source, the residual gravitational distortions of the optic, the despace of the VETA-I, and particulate contamination. We show how the data constrain the amplitude of mirror surface deviations for spatial frequencies greater than about 0.1 mm(exp -1). Constraints on the average amplitude of circumferential slope errors are derived as well.

Hughes, John P.↗

Characterization of Molybdate Conversion Coatings for Aluminum Alloys by Electrochemical Impedance Spectroscopy

Electrochemical impedance spectroscopy (EIS) was used to investigate the corrosion inhibiting properties of newly developed proprietary molybdate conversion coatings on aluminum alloy 2024-T3 under immersion in aerated 5% (w/w) NaCl. Corrosion potential and EIS measurements were gathered for six formulations of the coating at several immersion times for two weeks. Nyquist as well as Bode plots of the data were obtained. The conversion-coated alloy panels showed an increase in the corrosion potential during the first 24 hours of immersion that later subsided and approached a steady value. Corrosion potential measurements indicated that formulations A, D, and F exhibit a protective effect on aluminum 2024-T3. The EIS spectra of the conversion-coated alloy were characterized by an impedance that is higher than the impedance of the bare alloy at all the immersion times. The low frequency impedance, Z(sub lf) (determined from the value at 0.05 Hz) for the conversion-coated alloy was higher at all the immersion times than that of the bare panel. This indicates improvement of corrosion resistance with addition of the molybdate conversion coating. Scanning electron microscopy (SEM) revealed the presence of cracks in the coating and the presence of cubic crystals believed to be calcium carbonate. Energy dispersive spectroscopy (EDS) of the test panels revealed the presence of high levels of aluminum, oxygen, and calcium but did not detect the presence of molybdenum on the test panels. X-ray photoelectron spectroscopy (XPS) indicated the presence of less than 0.01 atomic percent molybdenum on the surface of the coating.

Calle, Luz Marina↗

Nanoscale Observation and Control of Quasiparticle Induced Magnetic Noise in a Superconducting Resonator

Superconducting circuits are arguably taking a leading role in driving the ongoing quantum technological revolution. A detailed knowledge of the microscopic fluctuating electromagnetic properties plays an important role in advancing the circuitry design, testing, and material integration of cutting-edge superconducting quantum electronics. Here, in this work, we report scanning nitrogen-vacancy (NV) quantum sensing of local magnetic noise environment of an on-chip superconducting resonator. We find that quasiparticle-induced fluctuating magnetic fields can drive NV spin relaxation, which shows a peak value around the superconducting transition point of niobium at the thermal equilibrium state. External microwave driving at the resonator mode frequency significantly increases the quasiparticle density, leading to enhancement of magnetic noise. We further perform optically detected magnetic resonance measurements to demonstrate quasiparticle magnetic noise mediated off-resonant dipole coupling between the NV center and niobium resonator. Our Letter reports experimental observation of the Hebel-Slichter peak signature by an external sensor outside of a superconductor. The presented study also highlights the advantages of quantum sensors in investigating miniaturized superconducting devices, providing insights into their future performance improvements.

Li, Senlei [Georgia Institute of Technology]↗

Monolithic millimeter-wave diode array beam controllers: Theory and experiment

In the current work, multi-function beam control arrays have been fabricated and have successfully demonstrated amplitude control of transmitted beams in the W and D bands (75-170 GHz). While these arrays are designed to provide beam control under DC bias operation, new designs for high-speed electronic and optical control are under development. These arrays will fill a need for high-speed watt-level beam switches in pulsed reflectometer systems under development for magnetic fusion plasma diagnostics. A second experimental accomplishment of the current work is the demonstration in the 100-170 GHz (D band) frequency range of a new technique for the measurement of the transmission phase as well as amplitude. Transmission data can serve as a means to extract ('de-embed') the grid parameters; phase information provides more complete data to assist in this process. Additional functions of the array beam controller yet to be tested include electronically controlled steering and focusing of a reflected beam. These have application in the areas of millimeter-wave electronic scanning radar and reflectometry, respectively.

Sjogren, L. B.↗

Development of a nondestructive vibration technique for bond assessment of Space Shuttle tiles

This final report describes the achievements of the above titled project. The project is funded by NASA-KSC (Grant No. NAG 10-0117) for the period of 1 Jan. to 31 Dec. 1993. The purpose of this project was to develop a nondestructive, noncontact technique based on 'vibration signature' of tile systems to quantify the bond conditions of the thermal protection system) tiles of Space Shuttle orbiters. The technique uses a laser rapid scan system, modal measurements, and finite element modeling. Finite element models were developed for tiles bonded to both clamped and deformable integrated skin-stringer orbiter mid-fuselage. Results showed that the size and location of a disbonded tile can be determined from frequency and mode shape information. Moreover, a frequency response survey was used to quickly identify the disbonded tiles. The finite element results were compared with experimentally determined frequency responses of a 17-tile test panel, where a rapidscan laser system was employed. An excellent degree of correlation between the mathematical simulation and experimental results was realized. An inverse solution for single-tile assemblies was also derived and is being implemented into a computer program that can interact with the modal testing software. The output of the program displays the size and location of disbond. This program has been tested with simulated input (i.e., finite element data), and excellent agreement between predicted and simulated disbonds was shown. Finally, laser vibration imaging and acoustic emission techniques were shown to be well suited for detecting and monitoring the progressive damage in Graphite/Epoxy composite materials.

Moslehy, Faissal A.↗

A Methodology for Surface Soil Moisture and Vegetation Optical Depth Retrieval Using the Microwave Polarization Difference Index

A methodology for retrieving surface soil moisture and vegetation optical depth from satellite microwave radiometer data is presented. The procedure is tested with historical 6.6 GHz brightness temperature observations from the Scanning Multichannel Microwave Radiometer over several test sites in Illinois. Results using only nighttime data are presented at this time, due to the greater stability of nighttime surface temperature estimation. The methodology uses a radiative transfer model to solve for surface soil moisture and vegetation optical depth simultaneously using a non-linear iterative optimization procedure. It assumes known constant values for the scattering albedo and roughness. Surface temperature is derived by a procedure using high frequency vertically polarized brightness temperatures. The methodology does not require any field observations of soil moisture or canopy biophysical properties for calibration purposes and is totally independent of wavelength. Results compare well with field observations of soil moisture and satellite-derived vegetation index data from optical sensors.

Owe, Manfred↗

A Flat-Panel 8x8 Sequentially Rotated Wideband Microstrip Patch Phased Array Antenna for K/Ka-band 6U CubeSat Communications Applications

Flat-panel electronically-scanned phased arrays have recently become a mainstream technology in the areas of radar and satellite applications, particularly due to their low profile and not having to steer the beams mechanically, both of which helps in realizing a lightweight phased array solution that also occupies a smaller volume. Typically for satellite applications, circularly polarized element radiators are often employed in order to deal with the signal fading problem. In this project, the main objective was to design a flat-panel phased array solution for 6U CubeSat communication applications. As for the required specifications, the array should have two operating bands: 22.55–23.55 GHz and 25.5–27.5 GHz, which span part of the K and Ka bands. For both these bands, the panel should be able to radiate dual circular polarization, in both transmit and receive modes, and with a stable gain performance. Since the individual bands are very closely spaced, it was realized that a single wideband design would be a better solution than a closely spaced dual-band design. Thus, a stacked microstrip patch configuration was selected for the element radiator design, which is known to be wideband. Now, it is rather difficult to realize both wide impedance and axial ratio bandwidths simultaneously, and at high frequencies, without complicating the element stacked patch design.. As a result, a sequential rotation technique wasemployed to significantly improves the axial ratio bandwidth and circular polarization purity of an array, all the while improving the pattern symmetry (P. S. Hall, “Application of Sequential Feeding to Wide Bandwidth, Circularly Polarised Microstrip Patch Arrays,” IEE Proc. H (Microw., Antennas Propag.), vol. 136, no. 5, pp. 390–398, Oct. 1989). The designed element radiator is a circularly-polarized probe-fed stacked patch antenna, which has a 10-dB matching bandwidth of 22.3– 30 GHz, with only a 5.14% axial ratio bandwidth around the center frequency of the required band, i.e., ~25 GHz. However, the resulting array demonstrates a very low axial ratio (≪ 3 dB) over the entire bandwidth, due to the application of the sequential rotation technique. The 8×8 array was able to scan up to ±51° and ±40° at frequencies 23.05 GHz and 26.5 GHz (center frequencies of the lower and upper bands), respectively, while maintaining a ≤ 3 dB axial ratio and a ≤ 3 dB gain drop from the corresponding peak broadside value at both the principle and the diagonal radiation planes. The designed layout for the 8×8 phased array prototype is shown in Fig. 1, which is currently undergoing fabrication and RF assembly. The antenna will be tested in the far-field anechoic chambers of the Antenna and Microwave Laboratory (AML) at San Diego State University and at NASA Glenn Research Center (GRC).

5G↗

Acoustic Predictions of the Moog S-250 in Hover

Acoustic predictions were made on the Moog S-250 vehicle to assess one of NASA’s mid-fidelity prediction toolchains for Urban Air Mobility-type vehicles. Experimental data from a 60-foot hover test is used for comparison. The S-250 is an RPM-controlled vehicle in a quadcopter-type configuration with four sets of contra-rotating rotors and powered by eight independently controlled electric motors. The same type of rotor blade used on the S-250 was 3D laser scanned to enable the development of custom-made airfoil tables and more accurate blade loadings. Noise predictions at the first couple of blade-pass frequencies indicate a good comparison to experimental data.

Acoustic prediction↗