Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Relationships Between the Performance of Time/Frequency Standards and Navigation/Communication Systems

The relationship between system performance and clock or oscillator performance is discussed. Tradeoffs discussed include: short term stability versus bandwidth requirements; frequency accuracy versus signal acquisition time; flicker of frequency and drift versus resynchronization time; frequency precision versus communications traffic volume; spectral purity versus bit error rate, and frequency standard stability versus frequency selection and adjustability. The benefits and tradeoffs of using precise frequency and time signals are various levels of precision and accuracy are emphasized.

Hellwig, H.↗

Single-screen triband FSS with double-square-loop elements

A single-screen double-square-loop (DSL) frequency selective surface (FSS) has been developed to multiplex the three frequency (S, X, and Ku) bands for NASA's CRAF/CASSINI mission. This triband DSL FSS reflects the X-band (7.2 and 8.4 GHz) waves and transmits the S-band (2.3 GHz) and the Ku-band (13.8 GHz) waves. A good agreement between predicted and measured transmission performance is found on a 0.001-in.-thick Kapton with/without a flat Kevlar honeycomb sandwich panel. It is found that the single-screen DSL FSS with/without the Kevlar honeycomb has a resonant frequency of 8.4 GHz for incident angle steered from normal to 45 deg and for both TE and TM polarizations.

Wu, T. K.↗

Auditory alert systems with enhanced detectability

Methods and systems for distinguishing an auditory alert signal from a background of one or more non-alert signals. In a first embodiment, a prefix signal, associated with an existing alert signal, is provided that has a signal component in each of three or more selected frequency ranges, with each signal component in each of three or more selected level at least 3-10 dB above an estimated background (non-alert) level in that frequency range. The alert signal may be chirped within one or more frequency bands. In another embodiment, an alert signal moves, continuously or discontinuously, from one location to another over a short time interval, introducing a perceived spatial modulation or jitter. In another embodiment, a weighted sum of background signals adjacent to each ear is formed, and the weighted sum is delivered to each ear as a uniform background; a distinguishable alert signal is presented on top of this weighted sum signal at one ear, or distinguishable first and second alert signals are presented at two ears of a subject.

Begault, Durand R.↗

The role of jet stability in edgetone generation.

Consideration of the role of stability of the mean jet flow of an edgetone system in the edgetone operation. A brief description of the main features of the edgetone operation and a brief review of the pertinent background are presented. This is followed by a discussion of the inadequacy of parallel flow stability considerations in explaining edgetone features. An analysis is made of the stability characteristics of a slightly nonparallel jet flow, and the role of jet stability based on these considerations in the edgetone operation is discussed. It is shown that the characteristics obtained by considering the nonparallel nature of the jet flowfield lead to a satisfactory description of the phenomenon, including a frequency selection criterion based on the concept of the most amplified disturbance frequency at each edge position.

Woolley, J. P.↗

Behavioral analysis of signals that guide learned changes in the amplitude and dynamics of the vestibulo-ocular reflex

We characterized the dependence of motor learning in the monkey vestibulo-ocular reflex (VOR) on the duration, frequency, and relative timing of the visual and vestibular stimuli used to induce learning. The amplitude of the VOR was decreased or increased through training with paired head and visual stimulus motion in the same or opposite directions, respectively. For training stimuli that consisted of simultaneous pulses of head and target velocity 80-1000 msec in duration, brief stimuli caused small changes in the amplitude of the VOR, whereas long stimuli caused larger changes in amplitude as well as changes in the dynamics of the reflex. When the relative timing of the visual and vestibular stimuli was varied, brief image motion paired with the beginning of a longer vestibular stimulus caused changes in the amplitude of the reflex alone, but the same image motion paired with a later time in the vestibular stimulus caused changes in the dynamics as well as the amplitude of the VOR. For training stimuli that consisted of sinusoidal head and visual stimulus motion, low-frequency training stimuli induced frequency-selective changes in the VOR, as reported previously, whereas high-frequency training stimuli induced changes in the amplitude of the VOR that were more similar across test frequency. The results suggest that there are at least two distinguishable components of motor learning in the VOR. One component is induced by short-duration or high-frequency stimuli and involves changes in only the amplitude of the reflex. A second component is induced by long-duration or low-frequency stimuli and involves changes in the amplitude and dynamics of the VOR.

NASA Discipline Neuroscience↗

A novel Doppler backscattering (DBS) system to simultaneously measure radio frequency plasma fluctuations and low frequency turbulence

A novel quadrature Doppler Backscattering (DBS) system has been developed and optimized for the E-band (60–90 GHz) frequency range using either O-mode or X-mode polarization in DIII-D plasmas. In general, DBS measures the amplitude of density fluctuations and their velocity in the lab frame. The system can simultaneously monitor both low-frequency turbulence (f < 10 MHz) and radiofrequency plasma density fluctuations over a selectable frequency range (20–500 MHz). Detection of high-frequency fluctuations has been demonstrated for low harmonics of the ion cyclotron frequency (e.g., 2f ci ~ 23 MHz) and externally driven high-frequency helicon waves (f = 476 MHz) using an adjustable frequency down conversion system. Importantly, this extends the application of DBS to a high-frequency spectral domain while maintaining important turbulence and flow measurement capabilities. This unique system has low phase noise, good temporal resolution (sub-millisecond), and excellent wavenumber coverage (k θ ~ 1–20 cm –1 and kr ≲ 30 cm –1 ). As a demonstration, localized internal DIII-D plasma measurements are presented from turbulence (f ≤ 5 MHz), Alfvenic waves (f ~ 6.5 MHz), ion cyclotron waves (f ≥ 20 MHz), as well as fluctuations around 476 MHz driven by an external high-power 476 MHz helicon wave antenna. In the future, helicon measurements will be used to validate GENRAY and AORSA modeling tools for prediction of helicon wave propagation, absorption, and current drive location for the newly installed helicon current drive system on DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Survey of man-made electrical noise affecting radio broadcasting

Survey, consisting of limited noise measurements, was made to augment and verify existing data at HF and VHF and to obtain basic data at UHF. Exact frequencies were determined by the absence of intentionally generated signals around three selected frequencies.

Bisignani, W. T.↗

Improved Dichroics For Microwave Reflector Antenna Systems

Panel contains array of grid and square conductive loops as array elements designed to reflect most of incident electromagnetic radiation in K(subu) band (13.5 to 15.5 GHz) and to pass that in X band (7 to 9 GHz). Designed to exhibit this dichroic property at angles of incidence up to 40 degrees in transverse electric, transverse magnetic, or circular polarization. Concept of gridded-square-loop dichroic array related to double-loop dichroic arrays described in "Frequency-Selective Microwave Reflectors" (NPO-18701). Improved version exhibits smaller shift of resonant frequency with angle of incidence.

Wu, Te-Kao↗

Extraordinary frequency stabilization by resonant nonlinear mode coupling

Here, we show that a self-sustained oscillator with a frequency-selective element operating with two nonlinearly coupled modes can achieve a level of frequency stability well beyond that available using single-mode operation. The system of interest consists of a self-sustained oscillator based on a nonlinear primary mode that is coupled via an internal resonance to a passive secondary mode. Analysis of a generic model for this resonance with both additive and multiplicative noises reveals that the stability improvements accrue from two sources: (i) nonlinear frequency veering in the primary mode, a classical analogue to quantum-level repulsion, that eliminates amplitude-to-frequency noise conversion; and (ii) phase cleaning of the oscillator through an intrinsic phase constraint arising from synchronization of the modes. This latter effect can significantly reduce the effects of intrinsic frequency fluctuations of the primary mode, which are not accessible by any known strategy using single-mode operation. The theoretical predictions are supported by experimental measurements of a microelectromechanical systems-based oscillator that demonstrate a reduction in oscillator line width of several orders of magnitude. This approach offers a means of optimizing frequency stability in self-sustained oscillators, which has direct implications for applications in timekeeping and sensing.

36 MATERIALS SCIENCE↗

Antennas and Propagation; Proceedings of the International Conference, 8th, Heriot-Watt Univeristy, Edinburgh, UK, Mar. 30 - Apr. 2, 1993. Vols. 1 & 2

Conference papers from sessions on the following topics are presented: satellite antennas; modal analysis of transmission line structures; fading and scintillation; microcellular; numerical analysis; Olympus; indoor mobile; mechanical aspects of satellite antennas; flat plate and printed antennas; fade counter measures; electromagnetic theory; feeds for satellites; antennas for personal communications; frequency selected surfaces; remote sensing; active patch antennas; antenna measurements; clear air/trans horizon; high frequency system and noise; rain attenuation and rain scatter; and high frequency direction finding.

Source record↗

PFLOTRAN-SIP: A PFLOTRAN Module for Simulating Spectral-Induced Polarization of Electrical Impedance Data

Spectral induced polarization (SIP) is a non-intrusive geophysical method that collects chargeability information (the ability of a material to retain charge) in the time domain or its phase shift in the frequency domain. Although SIP is a temporal method, it cannot measure the dynamics of flow and solute/species transport in the subsurface over long times (i.e., 10–100 s of years). Data collected with the SIP technique need to be coupled with fluid flow and reactive-transport models in order to capture long-term dynamics. To address this challenge, PFLOTRAN-SIP was built to couple SIP data to fluid flow and solute transport processes. Specifically, this framework couples the subsurface flow and transport simulator PFLOTRAN and geoelectrical simulator E4D without sacrificing computational performance. PFLOTRAN solves the coupled flow and solute-transport process models in order to estimate solute concentrations, which were used in Archie’s model to compute bulk electrical conductivities at near-zero frequency. These bulk electrical conductivities were modified while using the Cole–Cole model to account for frequency dependence. Using the estimated frequency-dependent bulk conductivities, E4D simulated the real and complex electrical potential signals for selected frequencies for SIP. These frequency-dependent bulk conductivities contain information that is relevant to geochemical changes in the system. This study demonstrated that the PFLOTRAN-SIP framework is able to detect the presence of a tracer in the subsurface. SIP offers a significant benefit over ERT in the form of greater information content. It provided multiple datasets at different frequencies that better constrained the tracer distribution in the subsurface. Consequently, this framework allows for practitioners of environmental hydrogeophysics and biogeophysics to monitor the subsurface with improved resolution.

54 ENVIRONMENTAL SCIENCES↗

Simulation of interference between Earth stations and Earth-orbiting satellites

It is often desirable to determine the potential for radio frequency interference between earth stations and orbiting spacecraft. This information can be used to select frequencies for radio systems to avoid interference or it can be used to determine if coordination between radio systems is necessary. A model is developed that will determine the statistics of interference between earth stations and elliptical orbiting spacecraft. The model uses orbital dynamics, detailed antenna patterns, and spectral characteristics to obtain accurate levels of interference at the victim receiver. The model is programmed into a computer simulation to obtain long-term statistics of interference. Two specific examples are shown to demonstrate the model. The first example is a simulation of interference from a fixed-satellite earth station to an orbiting scatterometer receiver. The second example is a simulation of interference from earth-exploration satellites to a deep-space earth station.

Bishop, D. F.↗

Additively Manufactured Interdigital Filters for Ultra- Wideband Radar

Abstract— In this paper, we present the development of ultrawideband (UWB) inter-digital cavity filters manufactured with an additive technique. We employed a selective laser melting process with stainless steel via a “flipping and fixturing” approach to achieve dimensional accuracy and frequency selectivity (no postfabrication tuning) comparable to that of conventional micromachining. The filters operate at a center frequency of 3.75 GHz and 6 GHz, respectively, with an instantaneous bandwidth of 2 GHz. This paper presents design and fabrication details, a discussion of measured characteristics for both filters, and a performance comparison with respect to subtractively manufactured parts.

Keywords— Interdigital filters, UWB radar, additiv↗

Carbon Nanotubes as Resonators for RF Spectrum Analyzers

Electromechanical resonators of a proposed type would comprise single carbon nanotubes suspended between electrodes (see Figure 1). Depending on the nanotube length, diameter, and tension, these devices will resonate at frequencies in a range from megahertz through gigahertz. Like the carbon-nanotube resonators described in the preceding article, these devices will exhibit high quality factors (Q values), will be compatible with integration with electronic circuits, and, unlike similar devices made from silicone and silicone carbide, will have tunable resonant frequencies as high as several GHz. An efficient electromechanical transduction method for the carbon nanotube resonators is provided by the previously observed variation of carbon nanotube length with charge injection. It was found that injection of electrons or holes, respectively, lengthens or shortens carbon nanotubes, by amounts of the order of a percent at bias levels of a few volts. The charge-dependent length change also enables a simple and direct means of tuning the resonant frequency by varying the DC bias and hence the tension along the tube, much like tuning a guitar string. In its basic form, the invention is a tunable high-Q resonator based on a suspended carbon nanotube bridge with attached electrodes (see Figure 1). An applied DC bias controls the tension and thus the frequency of resonance. If one were to superimpose a radio-frequency (RF) bias on the DC bias, then the resulting rapid variation in tension or length would set the tube into vibration. If, on the other hand, the carbon nanotube were to be set into vibration by interaction between an incident RF electric field and electric charges in the nanotube, then the vibration would give rise to an RF signal output that is proportional to the RF amplitude at the resonance frequency. Because the transduction mechanism is extremely sensitive and the active volume is only a few nanometers in diameter, this device is not well suited for use as a microwave power device. Instead, this carbon nanotube mechanical resonator would be useful primarily as part of a highly precise, sensitive, frequency-selective detector. An array of such devices featuring nanotubes of different lengths (and thus different frequencies) could be made to operate as a highspeed spectrum analyzer (see Figure 2)

Hunt, Brian↗

A Review of Variable-impedance Acoustic Liner Concepts Developed at NASA

This paper presents results attained in the NASA Langley Research Center test rigs using acoustic liners for which the impedance varies over the liner surface. These liners are typically designed for significant sound absorption over a wide frequency range, but it is also possible to design them to achieve increased absorption at selected frequencies. A brief review is provided regarding a number of variable-impedance concepts. The first is a modified version of a conventional two-layer liner, in which the embedded septum location and flow resistance are different for adjacent core chambers. Two concepts employ core chambers with different lengths, one with bent chambers to allow packaging within a limited volume, and the other with shared inlet ports to reduce the surface porosity. The last employs a perforated facesheet in which the hole diameter and porosity are varied over the surface of the liner. Data acquired in the NASA normal incidence and grazing flow impedance tubes are used to demonstrate the capabilities of these concepts. Impedance prediction models are also presented for comparison with these measured data.

Michael G. Jones↗