Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Diffusion of trace gases for leak detection - A study

Study reveals quantitative measurements of the diffusion of trace gases /Freon and helium/ injected into systems by different methods. Results show that uniform mixing does not always occur, thus evaluation of the system under test and establishment of the method of trace gas injection are mandatory.

Brown, J. L.↗

Evaluation of two gas-dilution methods for instrument calibration

Two gas dilution methods were evaluated for use in the calibration of analytical instruments used in air pollution studies. A dual isotope fluorescence carbon monoxide analyzer was used as the transfer standard. The methods are not new but some modifications are described. The rotary injection gas dilution method was found to be more accurate than the closed loop method. Results by the two methods differed by 5 percent. This could not be accounted for by the random errors in the measurements. The methods avoid the problems associated with pressurized cylinders. Both methods have merit and have found a place in instrument calibration work.

Evans, A., Jr.↗

Finite-Rate Ablation Boundary Conditions for Carbon-Phenolic Heat-Shield

A formulation of finite-rate ablation surface boundary conditions, including oxidation, nitridation, and sublimation of carbonaceous material with pyrolysis gas injection, has been developed based on surface species mass conservation. These surface boundary conditions are discretized and integrated with a Navier-Stokes solver. This numerical procedure can predict aerothermal heating, chemical species concentration, and carbonaceous material ablation rate over the heatshield surface of re-entry space vehicles. In this study, the gas-gas and gas-surface interactions are established for air flow over a carbon-phenolic heatshield. Two finite-rate gas-surface interaction models are considered in the present study. The first model is based on the work of Park, and the second model includes the kinetics suggested by Zhluktov and Abe. Nineteen gas phase chemical reactions and four gas-surface interactions are considered in the present model. There is a total of fourteen gas phase chemical species, including five species for air and nine species for ablation products. Three test cases are studied in this paper. The first case is a graphite test model in the arc-jet stream; the second is a light weight Phenolic Impregnated Carbon Ablator at the Stardust re-entry peak heating conditions, and the third is a fully dense carbon-phenolic heatshield at the peak heating point of a proposed Mars Sample Return Earth Entry Vehicle. Predictions based on both finite-rate gas- surface interaction models are compared with those obtained using B' tables, which were created based on the chemical equilibrium assumption. Stagnation point convective heat fluxes predicted using Park's finite-rate model are far below those obtained from chemical equilibrium B' tables and Zhluktov's model. Recession predictions from Zhluktov's model are generally lower than those obtained from Park's model and chemical equilibrium B' tables. The effect of species mass diffusion on predicted ablation rate is also examined.

Chen, Y.-K.↗

Instability of multistage compressor K1501

The K1501 compressor, driven by a steam turbine, is used to transport synthetic gas in fertilizer plants of 1000 tons daily production. The turbo-compressor set, which had been in operation since 1982, vibrated rather intensely, and its maximum load was only about 95 percent of the normal value. Damaging vibration to pads and gas-sealing labyrinths occurred three times from 1982 to 1983 and resulted in considerable economic loss. From the characteristics of the vibration, we suspected its cause to be rotor instability due to labyrinth-seal excitation. But, for lack of experience, the problem was not addressed for two years. Finally, we determined that the instability was indeed produced by labyrinth-seal excitation and corrected this problem by injecting gas into the middle-diaphragm labyrinths. This paper primarily discusses the failure and the remedy described above.

Zhou, Ren-Mu↗

Initial results of SEPAC scientific achievement

Electron beam injection of 5 keV, 300 mA (1.5 kW) and MPD arcjet plasma injection of 2 kJ/shot were successfully performed together with various kinds of diagnostic instruments including a high sensitivity TV camera observation in the Spacelab 1. Major scientific results obtained are studies of: (1) vehicle charge-up due to the electron beam emission and its neutralization by the MPD arcjet plasma; (2) beam-plasma interaction including the plasma wave excitation; (3) beam-atmosphere interaction such as the verification of critical velocity ionization effect; and (4) anomalous enhancement of ionization associated with a neutral gas injection into space.

Obayashi, T.↗

Cold Flow Testing for Liquid Propellant Rocket Injector Scaling and Throttling

Scaling and throttling of combustion devices are important capabilities to demonstrate in development of liquid rocket engines for NASA's Space Exploration Mission. Scaling provides the ability to design new injectors and injection elements with predictable performance on the basis of test experience with existing injectors and elements, and could be a key aspect of future development programs. Throttling is the reduction of thrust with fixed designs and is a critical requirement in lunar and other planetary landing missions. A task in the Constellation University Institutes Program (CUIP) has been designed to evaluate spray characteristics when liquid propellant rocket engine injectors are scaled and throttled. The specific objectives of the present study are to characterize injection and primary atomization using cold flow simulations of the reacting sprays. These simulations can provide relevant information because the injection and primary atomization are believed to be the spray processes least affected by the propellant reaction. Cold flow studies also provide acceptable test conditions for a university environment. Three geometric scales - 1/4- scale, 1/2-scale, and full-scale - of two different injector element types - swirl coaxial and shear coaxial - will be designed, fabricated, and tested. A literature review is currently being conducted to revisit and compile the previous scaling documentation. Because it is simple to perform, throttling will also be examined in the present work by measuring primary atomization characteristics as the mass flow rate and pressure drop of the six injector element concepts are reduced, with corresponding changes in chamber backpressure. Simulants will include water and gaseous nitrogen, and an optically accessible chamber will be used for visual and laser-based diagnostics. The chamber will include curtain flow capability to repress recirculation, and additional gas injection to provide independent control of the backpressure. This paper provides a short review of the appropriate literature, as well as descriptions of plans for experimental hardware, test chamber instrumentation, diagnostics, and testing.

Kenny, Jeremy R.↗

A continuously operating source of vacuum ultraviolet below 500 angstrom

Duo plasmatron type source of ultraviolet radiation operates in the wavelength region below 500 angstrom. Since the spectra produced are determined almost completely by the gas injected, and because the source operates continuously, this arrangement is beneficial in the development and calibration of filters and detectors within discrete wavelength ranges.

Source record↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately-known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is on the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream pressure. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of the total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is of the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream surface. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

S-2 stage 1/25 scale model base region thermal environment test. Volume 1: Test results, comparison with theory and flight data

A 1/25 scale model S-2 stage base region thermal environment test is presented. Analytical results are included which reflect the effect of engine operating conditions, model scale, turbo-pump exhaust gas injection on base region thermal environment. Comparisons are made between full scale flight data, model test data, and analytical results. The report is prepared in two volumes. The description of analytical predictions and comparisons with flight data are presented. Tabulation of the test data is provided.

Sadunas, J. A.↗

Optimization of confinement in a toroidal plasma subject to strong radial electric fields

A preliminary report on the identification and optimization of independent variables which affect the ion density and confinement time in a bumpy torus plasma is presented. The independent variables include the polarity, position, and number of the midplane electrode rings, the method of gas injection, and the polarity and strength of a weak vertical magnetic field. Some characteristic data taken under condition when most of the independent variables were optimized are presented. The highest value of the electron number density on the plasma axis is 3.2 x 10 to the 12th power/cc, the highest ion heating efficiency is 47 percent, and the longest particle containment time is 2.0 milliseconds.

Roth, J. R.↗

Optimization of confinement in a toroidal plasma subject to strong radial electric fields

The toroidal ring of plasma contained in the NASA Lewis Bumpy Torus facility may be biased to positive or negative potentials approaching 50 kV by applying dc voltages of the respective polarity to 12 or fewer midplane electrode rings. The radial electric fields, which are responsible for raising the ions to high energies by E x B/B-squared drift, then point out of or into the plasma. A preliminary report is given on the identification and optimization of independent variables which affect the ion density and confinement time in the Bumpy Torus plasma. The independent variables include the polarity, position, and number of the midplane electrode rings, the method of gas injection, and the polarity and strength of a weak vertical magnetic field. Some characteristic data taken under conditions where most of the independent variables were optimized are presented. The highest value of the electron number density on the plasma axis is 3.2 trillion per cu cm, the highest ion heating efficiency is 47%, and the longest particle containment time is 2.0 msec.

Roth, J. R.↗

Low cost silicon solar array project silicon materials task: Establishment of the feasibility of a process capable of low-cost, high volume production of silane (step 1) and the pyrolysis of silane to semiconductor-grade silicon (step 2)

A quartz fluid bed reactor capable of operating at temperatures of up to 1000 C was designed, constructed, and successfully operated. During a 30 minute experiment, silane was decomposed within the reactor with no pyrolysis occurring on the reactor wall or on the gas injection system. A hammer mill/roller-crusher system appeared to be the most practical method for producing seed material from bulk silicon. No measurable impurities were detected in the silicon powder produced by the free space reactor, using the cathode layer emission spectroscopic technique. Impurity concentration followed by emission spectroscopic examination of the residue indicated a total impurity level of 2 micrograms/gram. A pellet cast from this powder had an electrical resistivity of 35 to 45 ohm-cm and P-type conductivity.

Breneman, W. C.↗

Advanced cooling techniques for high-pressure hydrocarbon-fueled engines

The regenerative cooling limits (maximum chamber pressure) for 02/hydrocarbon gas generator and staged combustion cycle rocket engines over a thrust range of 89,000 N (20,000lbf) to 2,669,000 N (600,000 lbf) for a reusable life of 250 missions were defined. Maximum chamber pressure limits were first determined for the three propellant combinations (O2/CH4, O2/C3H8, and O2/RP-1 without a carbon layer (unenhanced designs). Chamber pressure cooling enhancement limits were then established for seven thermal barriers. The thermal barriers evaluated for these designs were: carbon layer, ceramic coating, graphite liner, film cooling, transpiration cooling, zoned combustion, and a combination of two of the above. All fluid barriers were assessed a 3 percent performance loss. Sensitivity studies were then conducted to determine the influence of cycle life and RP-1 decomposition temperature on chamber pressure limits. Chamber and nozzle design parameters are presented for the unenahanced and enhanced designs. The maximum regenerative cooled chamber pressure limits were attained with the O2/CH4 propellant combination. The O2/RP-1 designs relied on a carbon layer and liquid gas injection chamber contours, short chamber, to be competitive with the other two propellant combinations. This was attributed to the low decomposition temperature of RP-1.

Cook, R. T.↗

The state of the art of conventional flow visualization techniques for wind tunnel testing

Conventional wind tunnel flow visualization techniques which consist of surface flow methods, tracers, and optical methods are presented. Different surface flow methods are outlined: (1) liquid films (oil and fluorescent dye and UV lighting, renewable film via porous dispenser in model, volatile carrier fluid, cryogenic colored oil dots, oil film interferometry); (2) reactive surface treatment (reactive gas injection, reversible dye); (3) transition and heat transfer detectors (evaporation, sublimation, liquid crystals, phase change paints, IR thermography); and (4) tufts (fluorescent mini tufts, cryogenic suitability). Other methods are smoke wire techniques, vapor screens, and optical methods.

Settles, G. S.↗

Development of a distributed-parameter mathematical model for simulation of cryogenic wind tunnels

A one-dimensional distributed-parameter dynamic model of a cryogenic wind tunnel was developed which accounts for internal and external heat transfer, viscous momentum losses, and slotted-test-section dynamics. Boundary conditions imposed by liquid-nitrogen injection, gas venting, and the tunnel fan were included. A time-dependent numerical solution to the resultant set of partial differential equations was obtained on a CDC CYBER 203 vector-processing digital computer at a usable computational rate. Preliminary computational studies were performed by using parameters of the Langley 0.3-Meter Transonic Cryogenic Tunnel. Studies were performed by using parameters from the National Transonic Facility (NTF). The NTF wind-tunnel model was used in the design of control loops for Mach number, total temperature, and total pressure and for determining interactions between the control loops. It was employed in the application of optimal linear-regulator theory and eigenvalue-placement techniques to develop Mach number control laws.

Tripp, J. S.↗