Search NASA⌕ Search

SEARCH · Search NASA

Results for “glazing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Photoelectrons and solar wind/lunar limb interaction.

It is suggested that boundary conditions for solar wind/lunar limb interactions are active. The 'whole-moon' limb does not evoke a shock cone, because warm (approximately equal 13 eV/electron) solar wind electrons are replaced by cool (less than or equal to 2 eV/electron) photoelectrons that are ejected from the generally smooth areas of the lunar terminator illuminated at glazing angles by the sun. A localized volume of low thermal pressure is created in the solar wind by these cool photoelectrons. The solar wind expands into this turbulence-suppressive volume without shock production. Conversely, directly illuminated highland areas exchange hot photoelectrons (greater than 20 eV/electron) for warm solar wind electrons. The hot electrons generate a localized pressure increase in the adjacent solar wind flow which evokes a shock streamer in the solar wind. Shock streamers are identifiable by a coincident increase in the magnitude of the solar wind magnetic field immediately external to the lunar wake. Shock occurrence is controlled by lunar topography, solar activity in the hard ultraviolet (greater than 20 eV), solar wind electron density and thermal velocity, and the intensity of the solar wind magnetic field.

Criswell, D. R.↗

Investigation of mounting discrete chip components for hybrid microelectronic applications.

In the assembly of hybrid microcircuits, passive and active discrete chip components are attached by epoxy cements and by solders. This study was initiated to determine the integrity of such attachments. Alumina substrates were subjected to a group of thermal and mechanical test environments defined by test methods in MIL-STD-883. Lot samples of substrates with assembly variations were subjected to separately applied testing and to serial testing. These test methods were applied sequentially to the same lot of substrates. Epoxy cements were generally satisfactory with respect to separate tests, although sequential tests severely degraded epoxy bond strengths of all types. Bond strengths to unglazed substrates were slightly superior to those of the same components on glazed types. Solder joints were vulnerable to catastrophic failure in several environments, especially temperature cycling and thermal shock. Vibration and impact shock also produced solder joint failures.

Caruso, S. V.↗

The photometric properties of natural snow and of snow-covered planets

Using the white light measurements of Knowles Middleton and Mungall (1952), the Minnaert constants, k and B sub zero, are derived for six types of snow surfaces for phase angles up to 80 deg. The conclusion is that snow is in general a quasi-Lambert scatterer (k = 1.04 to 1.35). Even in an extreme case of specular reflection (a 'glazed rain crust'), k is less than 2 at these phase angles. The range in k and B sub zero suggested by these data are then used to estimate some fundamental photometric parameters of smooth snow-covered planets: geometric albedos, phase integrals, Bond albedos, and phase coefficients.

Veverka, J.↗

Scanning electron microscopy of lunar regolith from the Sea of Fertility

Scanning electron microscopy was used in studying the morphology and cathodoluminescence of lunar regolith particles. Surface and structure of two groups of particles are differentiated: (1) Crystalline with well defined facets and spalling surfaces, which are grains of minerals and rock fragments: and (2) amorphous, fused, and partially or entirely glazed particles. Local melting of particles and the round openings on their surfaces are attributed to secondary influence on the regolith of factors of lunar weathering and above all micrometeoric impacts.

Antoshin, M. K.↗

Flat-Plate Solar-Collector Performance Evaluation with a Solar Simulator as a Basis for Collector Selection and Performance Prediction

The use of a solar simulator for performance determination permits collector testing under standard conditions of wind, ambient temperature, flow rate and sun. The performance results determined with the simulator have been found to be in good agreement with outdoor performance results. The measured thermal efficiency and evaluation of 23 collectors are reported which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, antireflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors were given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance was made possible by tests at different incident angles. The solar performance rankings were made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Flat-plate solar-collector performance evaluation with a solar simulator as a basis for collector selection and performance prediction

This paper reports the measured thermal efficiency and evaluation of 23 collectors which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, anti-reflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors are given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance is made possible by tests at different incident angles. The solar performance rankings are made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

The use of solar simulation systems for producing artificial global radiation for the purpose of determining the heat load of rooms

Certain climatic tests which require solar and sky radiation were carried out in the laboratory by using simulated global radiation. The advantages of such a method of measurement and the possibilities and limitations resulting from the simulation of global radiation are described. Experiments concerning the thermal load in rooms were conducted in order to test the procedure. In particular, the heat gain through a window with sunshade is discussed, a venetian blind between the panes of a double-glazed window being used in most cases.

Kalt, A. C.↗

High-efficiency solar concentrator

A new type of solar concentrator is presented using liquid lenses and simple translational tracking mechanism. The concentrator achieves a 100:1 nominal concentration ratio and is compared in performance with a flat-plate collector having two sheets of glazing and non-selective coating. The results of the thermal analysis show that higher temperatures can be obtained with the concentrator than is possible with the non-concentrator flat-plate type. Furthermore, the thermal efficiency far exceeds that of the comparative flat-plate type for all operating conditions.

Lansing, F. L.↗

Summer performance results obtained from simultaneously testing ten solar collectors outdoors

Ten solar collectors were simultaneously tested outdoors. Efficiency data were correlated using a method that separates solar variables (flux, incident angle) from the desired performance parameters (heat loss, absorbtance, transmittance) which are unique to a given collector design. Tests were conducted on both clear and moderately cloudy days. Correlating data in the above manner, a 2-glass, black paint collector exhibited a decrease in efficiency of 5 percentage points relative to the baseline data for an exposure time of 2 years, 4 months. Condensation on the collector glazing was thought to be a contributing factor in this efficiency change.

Miller, D. R.↗

Thermal performance of a hot-air solar collector

Report contains procedures and results of thermal-performance tests on double-glazed air solar collector. Four types of tests were carried out including thermal-efficiency and stagnation tests, collector time-constant tests to assess effects of transients, and incident-angle modifier tests. Data are presented in tables and as graphs and are discussed and analyzed.

Source record↗

Performance evaluation of an air solar collector

Indoor tests on signal-glazed flat-plate collector are described in report. Marhsall Space Flight Center solar simulator is used to make tests. Test included evaluations on thermal performance under various combinations of flow rate, incident flux, inlet temperature, and wind speed. Results are presented in graph/table form.

Source record↗

Liquid solar collector-performance tests

Report describes comprehensive performances test on commercially-available modular nonmetallic single-glazed liquid solar collector to verify compliance with U. S. Housing and Urban Development Department standards for thermal stability. Program includes tests of initial thermal performance, 30 day stagnation, and final external performance.

Source record↗

Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

Chiou, J., Sr.↗

Collation of quarterly reports on air flat plate collectors

The solar 2 air flat plate collectors are described. The development and fabrication of a prototype air flat plate collector subsystem containing 320 square feet of collector area are described. Three instrumented panels were completely assembled with glazing and insulation. Manufacture of the last seven prototype collectors was completed in October 1977.

Source record↗

Indoor test for thermal performance evaluation of the Solaron (air) solar collector

The test procedure used and the results obtained from an evaluation test program, conducted to obtain thermal performance data on a Solaron double glazed air solar collector under simulated conditions in a solar simulator are described. A time constant test and incident angle modifier test were also conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed. The Solaron collector absorber plate is made of 24-gage steel, the coating is baked-on black paint, the cover consists of two sheets of 1/8-inch low-iron tempered glass, and the insulation is one thickness of 3 5/8-inch fiberglass batting.

Source record↗

Indoor thermal performance evaluation of the SEPCO air collector

The procedures used and the results obtained during the evaluation test program on the Solaron solar air collector, model EF-212, under simulated conditions for comparison with data collected in outdoor tests on the same collector are given. The test article was a single glazed collector with a nonsensitive absorber plate, aluminum box frame, and one inch isocyanurate foam insulation.

Source record↗

Indoor test for thermal performance evaluation on the Sunworks (air) solar collector

The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a Sunworks single glazed air solar collector under simulated conditions are described. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.

Source record↗

Indoor test for thermal performance evaluation on life sciences engineering (air) solar collector

The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a life sciences double-glazed air solar collector under simulated conditions is discussed. These tests were made using the Marshall Space Flight Center's solar simulator. A time constant test and incident angle modifier test were also conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.