Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid simulator testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Electric Power Delivery Testing Feasibility Study (Task 6 Final Report)

This Final Report is covers the completion of the Electric Power Delivery Testing Feasibility Study. The objective of this project was to research, engineer, and demonstrate high-power laboratory testing protocols to accurately reproduce the conditions on the electric power grid representing both normal load switching and abnormalities such as short-circuit fault protection. Test circuits, equipment, and techniques were developed and proven at reduced power levels to determine the feasibility of building a large-scale high-power testing laboratory capable of testing equipment and systems at simulated high-power conditions of the U.S. power grid at distribution levels up through 38 kiloVolts (kV) and transmission levels up through 230 kV. The project delivered demonstrated testing techniques, high-voltage test equipment for load testing and synthetic short-circuit testing, and recommended designs for future implementation of a high-power testing laboratory to test equipment and systems, enabling increased reliability of the electric transmission and distribution grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anisotropic fluid dynamical simulations of heavy-ion collisions

We present VAH, a (3+1)–dimensional simulation that evolves the far-from-equilibrium quark-gluon plasma produced in ultrarelativistic heavy-ion collisions with anisotropic fluid dynamics. We solve the hydrodynamic equations on an Eulerian grid using the Kurganov–Tadmor algorithm in combination with a new adaptive Runge–Kutta method. Our numerical scheme allows us to start the simulation soon after the nuclear collision, largely avoiding the need to integrate it with a separate pre-equilibrium dynamics module. We test the code's performance by simulating on the Eulerian grid conformal and non-conformal Bjorken flow as well as conformal Gubser flow, whose (0+1)–dimensional solutions are precisely known. Finally, we compare non-conformal anisotropic hydrodynamics to second-order viscous hydrodynamics in central Pb+Pb collisions and find that the former's longitudinal flow profile responds more consistently to the fluid's gradients along the spacetime rapidity direction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PHIL Inverter Test Report: Analysis of High-Penetration Levels of PV into the Distribution Grid in California, March 12 - March 16, 2012

This report describes power hardware-in-the-loop simulation testing of a 500 kW Satcon photovoltaic inverter, conducted at the Center for Advanced Power Systems at Florida State University from March 12th through March 16th, 2012. Testing was led by a team from the National Renewable Energy Laboratory. The report reviews the results of data captured during the course of testing. The tests were used to demonstrate operation of and gather data from the inverter in a simulated operational environment. Testing demonstrated the ability of the inverter to operate in either a Power Factor Control Mode or a Reactive Power Command Mode, and to respond to real power limits.

14 SOLAR ENERGY↗

The importance of considering sub-grid cloud variability when using satellite observations to evaluate the cloud and precipitation simulations in climate models

Abstract. Satellite cloud observations have become an indispensable tool for evaluating general circulation models (GCMs). To facilitate the satellite and GCM comparisons, the CFMIP (Cloud Feedback Model Inter-comparison Project) Observation Simulator Package (COSP) has been developed and is now increasingly used in GCM evaluations. Real-world clouds and precipitation can have significant sub-grid variations, which, however, are often ignored or oversimplified in the COSP simulation. In this study, we use COSP cloud simulations from the Super-Parameterized Community Atmosphere Model (SPCAM5) and satellite observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) and CloudSat to demonstrate the importance of considering the sub-grid variability of cloud and precipitation when using the COSP to evaluate GCM simulations. We carry out two sensitivity tests: SPCAM5 COSP and SPCAM5-Homogeneous COSP. In the SPCAM5 COSP run, the sub-grid cloud and precipitation properties from the embedded cloud-resolving model (CRM) of SPCAM5 are used to drive the COSP simulation, while in the SPCAM5-Homogeneous COSP run only grid-mean cloud and precipitation properties (i.e., no sub-grid variations) are given to the COSP. We find that the warm rain signatures in the SPCAM5 COSP run agree with the MODIS and CloudSat observations quite well. In contrast, the SPCAM5-Homogeneous COSP run which ignores the sub-grid cloud variations substantially overestimates the radar reflectivity and probability of precipitation compared to the satellite observations, as well as the results from the SPCAM5 COSP run. The significant differences between the two COSP runs demonstrate that it is important to take into account the sub-grid variations of cloud and precipitation when using COSP to evaluate the GCM to avoid confusing and misleading results.

54 ENVIRONMENTAL SCIENCES↗

NREL Innovations Help Drive Wind Industry Transformation [Fact Sheet]

For nearly 30 years, NREL has helped the wind turbine industry through design and research innovations. The comprehensive capabilities of the National Wind Technology Center (NWTC), ranging from specialized computer simulation tools to unique test facilities, has been used to design, develop, and deploy several generations of advanced wind energy technology.

17 WIND ENERGY↗

Benchmarking Data for the Proposed Signature of Used Fuel Casks

A set of benchmarking measurements to test facets of the proposed extended storage signature was conducted on May 17, 2016. The measurements were designed to test the overall concept of how the proposed signature can be used to identify a used fuel cask based only on the distribution of neutron sources within the cask. To simulate the distribution, 4 Cf-252 sources were chosen and arranged on a 3x3 grid in 3 different patterns and raw neutron totals counts were taken at 6 locations around the grid. This is a very simplified test of the typical geometry studied previously in simulation with simulated used nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of Electromagnetic Transient and Phasor-based Simulation for the Stability of Grid-Forming-Inverter-based Microgrids

The increasing interest in studying feeder-level, inverter-based microgrids requires appropriate simulation methods that can effectively simulate the dynamics of distribution feeders that typically have thousands of nodes. To examine the accuracy of phasor-based simulation for the stability of feeder-level, inverter-based microgrids, a comparative study between electromagnetic transient (EMT) and phasor-based simulation was conducted. Case studies of a two-inverter small microgrid and a modified version of the IEEE 34-Node Test System that has seven grid-forming inverters show that phasor-based simulation agrees well with EMT simulation when the P-f droop gains of grid-forming inverter controllers are within normal ranges. However, under extremely high P-f droop gains, phasor-based simulation can result in over-optimistic stability results. This study provides insight into the applicability of phasor-based simulation for the stability of feeder-level, inverter-based microgrids.

Du, Wei↗

Advanced Research on Integrated Energy Systems (ARIES) Cyber Range Overview and Threat-to-Consequence Demonstration

This presentation was presented at the Aggregation and Grid Security Workshop - held on June 17-18, 2025, at NREL in Golden, Colorado. The goal of the two-day workshop was to address the critical cybersecurity challenges for the future electric grid. The threat-to-consequence demonstration showcases NREL's capability to model, simulate, test, and evaluate cyberattacks targeting energy systems that coincide with natural hazards, as well as the ramifications for the energy grid as a whole.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner

Purpose: Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and detector during the scan would result in unacceptable loss of primary radiation. However, in the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis, the tube and detector rotate around a common axis, thereby maintaining a fixed tube-detector alignment. This C-arm geometry raises the possibility of using a 2D (cellular) focused antiscatter grid. The purpose of this study is to assess change in image quality when using an antiscatter grid in the DBT portion of a DMT scan under conditions of fixed radiation dose. Methods: Two 2D focused prototype grids with 80 cm focal length were tested, one stack-laminated from copper (Cu) and one cast from a tungsten-polymer (W-poly). They were reciprocated using a motion scheme designed to maximize transmission of primary x-ray photons. Grid-in and grid-out scatter-to-primary ratios (SPRs) were measured for rectangular blocks of material simulating 30%, 50%, and 70% glandular tissue compositions. For assessment of changes in image quality through the addition of a grid, the Computerized Imaging Reference Systems, Inc., phantom Model 011A containing a set of 1 cm thick blocks simulating a range of glandular/adipose ratios from 0/100 to 100/0 was used. To simulate 6.5 and 8.5 cm thick compressed breasts, 1 cm thick slices of PMMA were added to the Model 011A phantom. DBT images were obtained with and without the grid, with exposure parameters fixed for a given compressed thickness. Signal-difference-to-noise ratios (SDNRs), contrast, and voxel value-based attenuation coefficients (μ) were measured for all blocks from reconstructed phantom images. Results: For 4, 6, and 8 cm tissue-equivalent block phantom thicknesses, the inclusion of the W-poly grid reduced the SPR by factors of 5, 6, and 5.8, respectively. For the same thicknesses, the copper grid reduced the SPR by factors of 3.9, 4.5, and 4.9. For the 011A phantom, the W-poly grid raised the SDNR of the 70/30 block from 0.8, −0.32, and −0.72 to 0.9, 0.76, and 0.062 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. It raised the SDNR of the 100/0 block from 3.78, 1.95, and 1.0 to 3.79, 3.67, and 3.25 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. Inclusion of the W-poly grid improved the accuracy of image-based μ values for all block compositions. However, smearing of attenuation across slices due to limited angular sampling decreases the sensitivity of voxel values to changing composition compared to theoretical μ values. Conclusions: Under conditions of fixed radiation dose to the breast, use of a 2D focused grid increased contrast, SDNR, and accuracy of estimated attenuation for mass-simulating block compositions in all phantom thicknesses tested, with the degree of improvement depending upon material composition. A 2D antiscatter grid can be usefully incorporated in DBT systems that employ fully isocentric tube-detector rotation.

60 APPLIED LIFE SCIENCES↗

Nonlinear simulations of thermo-resistive tearing mode formalism of the density limit

This work is an extension of the previous semi-analytical work (Teng et al 2016 Nucl. Fusion 56 106001), explaining the density limit with a thermo-resistive tearing mode model. The thermo-resistive island growth is calculated with a 3D MHD code M3D-C 1 (Jardin et al 2012 Comput. Sci. Discovery 5 014002). It is shown with nonlinear 3D MHD simulations that impurity radiation stimulates large magnetic islands at the density limit. The impact of thermal perturbations inside and outside of the island is explored. Inside the island, net cooling enhances the island growth and net heating suppresses its growth. Outside the island, thermal perturbations have a much smaller impact on the island growth. When the plasma density is increased towards the density limit, the island changes from being heated to being cooled and grows to a much larger island width. The convergence test of the simulations over the temporal and spatial grid is performed. In conclusion, the numerical model and the semi-analytical model are compared by calculating the Δ' terms, which are defined in the modified Rutherford equation, and good agreement is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GPS Spoofing Attack Characterization and Detection in Smart Grids

The problem of global positioning system (GPS) spoofing attacks on smart grids endowed with phasor measurement units (PMUs) is addressed, taking into account the dynamical behavior of the states of the system. First, it is shown how GPS spoofing introduces a timing synchronization error in the phasor readings recorded by the PMUs and alters the measurement matrix of the dynamical model. Then, a generalized likelihood ratio-based hypotheses testing procedure is devised to detect changes in the measurement matrix when the system is subjected to a spoofing attack. Monte Carlo simulations are performed on the 9-bus, 3-machine test grid to demonstrate the implication of the spoofing attack on dynamic state estimation and to analyze the performance of the proposed hypotheses test.

97 MATHEMATICS AND COMPUTING↗

An Open-Source Virtual Testbed for a Real Net-Zero Energy Community

Net zero energy communities (NZECs) are critical to ensure sustainability and resilience of modernized power systems. System modeling helps overcome technical challenges in designing and operating NZECs. In this paper, we present the modeling work based on a real NZEC. Two sets of models are developed: higher-fidelity physics-based models considering the interaction between subsystems of the studied NZEC and capturing fast-dynamics; and lower-fidelity data-driven models requiring less resource to establish and/or run. All models are validated against measurements from this real NZEC. In addition, we create a simulation framework which streamlines the processes for simulation and thus allows using developed models to form a virtual testbed. To demonstrate the usage of the virtual testbed, a case study is conducted where a building-to-grid integration control is evaluated via simulation. The evaluation results suggest that the tested control significantly smooths the power draw of the studied community and doesn’t sacrifice the thermal comfort to a great extent.

Huang, Sen↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services

This paper develops a hierarchical control frame-work to aggregate and to manage behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. In the proposed framework, firstly, each controller in the hierarchy determines the flexibility of the DERs such that the obtained flexibility is feasible with respect to its operational purview. For example, the operational purview of a home energy management system may only consider consumer comfort preferences, while that for an aggregator or a grid controller may consider network voltage management as well. Based on the feasible flexibility, optimal setpoints for the DERs is then determined by the hierarchical controllers to help the distribution power network in voltage regulation, coordination issues with existing transmission-level conventional generators, etc. Therefore, the proposed strategy, which is based on model-predictive control, can be effectively utilized by the distribution network to coordinate several DERs to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Application Function Blocks for Power-Hardware-in-the-Loop Testing of Grid-Connected Inverters: Preprint

Stability and accuracy of the PHIL platform has been a common problem and challenging issue for a long time, thus continuous efforts and research have been devoted to developing interface algorithms to improve upon this. Some of existing works exhibit promising solutions to compensate the errors in the PHIL platform. However, there is a need to harmonize various solutions into a standard framework that provides a general solution for various PHIL test beds and that can be reused with minimum modifications to avoid extra effort. A good way to do this is by using application function blocks (AFBs), which are model-based and can be developed as a standard library component, thus achieving satisfactory reusability and reconfigurability for various platforms. Since PHIL simulation has the flexibility of the software simulation, proper functions can be easily implemented in the digital real-time simulator (DRTS) to preprocess the reference signal before sending it to the power amplifier. Therefore, this paper aims to develop standard AFBs in DRTS for the PHIL interface to test grid-connected inverters. The PHIL interface algorithm is separated into five AFBs that will be presented in detail in this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seabed bathymetry and friction modeling in MoorDyn

This paper presents the implementation and verification of a seabed bathymetry feature and seabed friction feature to the open-source, lumped-mass mooring system dynamics modeler, MoorDyn, which is part of the National Renewable Energy Laboratory’s aero-hydro-servo-elastic simulation tool, OpenFAST. Variations in seabed slope, as well as the frictional effects of mooring lines moving along the seabed, will affect the mooring line tensions of a floating platform and the consequent platform response. These new features are especially relevant for modeling mooring systems in deep-water coastal areas where seabed depth can change significantly over an entire mooring footprint. The bathymetry feature models the seabed as a rectangular grid of variable water depths in place of the existing, uniform water depth in MoorDyn. The friction force is primarily represented as a Coulombic friction force, or the product of a kinetic friction coefficient and the seabed contact normal force, with the ability to differentiate between transverse and axial motion of a line node on the seabed in any bathymetry grid. These capabilities were tested by running MoorDyn and OpenFAST simulations over a variety of seabed and environmental conditions; the resulting fairlead tensions, node tensions, and mooring line kinematics were verified against equivalent OrcaFlex simulations. The results match closely, meaning the features are verified, which will increase the overall fidelity of OpenFAST and FAST.Farm simulations.

17 WIND ENERGY↗

Adaptive Neuro Fuzzy Inference System for Cyber-Intrusion Detection in a Smart Grid

The evolution of the power grid has brought increasing deployment of advance metering infrastructure, penetration of intelligent electronic devices, and integration of physical power system components with information and communications technologies. With the fast-expanding connectivity, cyber vulnerabilities arise due to the use of internet-based communication systems. These systems are targets of cyber-intrusions which attempt to disturb the normal power system functions. Traditional intrusion detection algorithms have been developed without an explicit model of the cyber components. In this paper, an algorithm to detect false data injections in the power system is proposed considering both cyber and physical models of the power system. The algorithm is based on an Adaptive Neuro Fuzzy Inference System (ANFIS) which collects information from state variables of the cyber-physical system to meet the performance requirements of the grid. Simulations of the proposed approach using the IEEE 13-bus test system validate the effectiveness of this artificial intelligence-based algorithm.

Adaptive Neuro Fuzzy Inference System (ANFIS), cyb↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗