Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid support”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

HydraGNN_OPF_GFM_2026 - Ensemble of predictive graph foundation models for power grid applications

This dataset supports research on graph foundation models for optimal power flow (OPF) on electric grids using HydraGNN. It contains heterogeneous graph representations of PGLib-OPF cases spanning systems from 14 to 13,659 buses, together with packed HDF5 datasets for pretraining, feasibility classification, and N-1 contingency analysis. The release includes OPF solution data, downstream fine-tuning datasets, pretrained HeteroSAGE and HeteroHEAT model checkpoints, hyperparameter-optimization summaries across multiple heterogeneous GNN architectures, and aggregated fine-tuning results for sample-efficiency studies. The dataset is designed to enable scalable training, evaluation, and transfer-learning studies for OPF surrogate modeling, including node-level AC-OPF solution prediction, graph-level prediction, feasibility classification, operating-condition generalization, and contingency-response tasks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Level Assessment of Grid Infrastructure in Southeast Asia to Support Regional Interconnections

The purpose of this slide deck is to provide an overview of the benefits of interregional transmission and to assess the specific transmission landscape of Southeast Asia, with respect to potential interconnections between Singapore and neighboring countries. This analysis also explores the distribution of renewable resources and electricity demand in ASEAN (the Association of Southeast Asian Nations) as well as current and anticipated interregional transmission, in order to inform future interconnection plans.

ASEAN↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensor Data Analytics and Data Quality Assessment Software

The proposed framework derives a set of quality metrics to provide critical insights into and tracking of grid operations, sensor performance, sensor longevity, and event statistics. Power grid engineers can utilize this information to identify problems with existing sensor locations and problematic power grid assets including generators, transmission lines, load centers, and substations. This information can also be used to identify unexpected/abnormal behavior of power grid components, improve power grid observability, and operational monitoring, and thus enhance real-time decision-making support system. Power grid planners can utilize this information to augment existing sensing architecture with new sensors and improve the observability of the network.

Mahapatra, Kaveri↗

GODEEEP-hydro: Historical and projected power system ready hydropower data for the United States

Hydropower is a critical electricity resource in the United States which, in addition to low-cost electricity generation, provides valuable ancillary grid services, and supports the integration of nondispatchable weather-dependent resources (e.g., wind and solar). Despite its value to the grid, there are very few comprehensive datasets available from which to study both historical and future impacts of climate, weather driven energy droughts, and integration of other weather driven generation. In this paper, we present a hydropower generation dataset covering 1,452 hydroelectric plants in the contiguous U.S. The dataset contains monthly and weekly hydropower generation estimates for both historical (1982–2019) and future (2020–2099) periods which includes 4 future climate scenarios. In addition, this dataset provides weekly and monthly constraints such as minimum and maximum power which are particularly useful in power system models which are used to study grid reliability, transmission planning and capacity expansion.

13 HYDRO ENERGY↗

Operational experience and R&D results using the Google Cloud for High-Energy Physics in the ATLAS experiment

The ATLAS experiment at CERN relies on a Worldwide Distributed Computing Grid infrastructure to support its physics program at the Large Hadron Collider. ATLAS has integrated cloud computing resources to complement its Grid infrastructure and conducted an R&D program on Google Cloud Platform. These initiatives leverage key features of commercial cloud providers: lightweight configuration and operation, elasticity and availability of diverse infrastructures. Here this paper examines the seamless integration of cloud computing services as a conventional Grid site within the ATLAS workflow management and data management systems, while also offering new setups for interactive, parallel analysis. It underscores pivotal results that enhance the on-site computing model and outlines several R&D projects that have benefited from large-scale, elastic resource provisioning models. Furthermore, this study discusses the impact of cloud-enabled R&D projects in three domains: accelerators and AI/ML, ARM CPUs and columnar data analysis techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

How Fisheries Biologists Can Facilitate the Clean Energy Transition

Abstract Fisheries and aquatic biologists play a critical role in creating environmentally protective hydropower flow requirements that govern flow timing, frequency, magnitude, and rate of change. Hydropower's role in the U.S. electrical grid is expected to evolve in response to increased wind and solar generation as hydropower will be called upon to quickly ramp up and down in response to changes in wind and solar generation. For this reason, hydropower is expected to have increased value as fossil generation is phased out, even as rapid flow fluctuations linked with hydropower flexibility may strand fish, alter habitat, and create unsafe recreational conditions. We face a new challenge in facilitating the renewable energy transition—designing environmental flow requirements that protect against the impacts of flow fluctuations while allowing adequate hydropower flexibility to support a stable grid. In this paper, we discuss hydropower environmental flow requirements, operational flexibility, and electrical grid stability, their potential interactions, and opportunities to align environmental and power system needs to support healthy ecosystems, multiple water uses, and decarbonization of the electric grid.

13 HYDRO ENERGY↗

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗

Integrating Electric Vehicles into the Grid

Historically, transportation and power systems operated independently, but the rise of electric vehicles is transforming this relationship. In the United States, EV demands are expected to become the largest source of electricity load growth, posing challenges for the grid if not properly managed. This presentation highlights how managed charging strategies and strategic infrastructure deployment can integrate EVs into the power system to enhance grid efficiency and support renewable energy.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Mechanical Solution for Existing Conductors

The rapid growth in energy demand, driven by advancements in AI technology, renewable energy integration, and increased industrial activity, highlights the need for innovative solutions to improve the resiliency and efficiency of the power grid. This report details the fire testing of GridWrap’s Composite WiRe Wrap, to evaluate the wrap's ability to enhance conductor performance under wildfire-simulated conditions. Conductors were prepared and tested in a controlled environment at 400°C for 18 minutes, during which sag and temperature data were recorded. The results demonstrated that the unwrapped conductor sagged 3/16ths of an inch, while the WiRe Wrapped conductor sagged only 1/16th of an inch under identical conditions, indicating a significant improvement in mechanical performance. This project, conducted as part of a collaborative effort between BEA (Idaho National Laboratory’s managing contractor) and GridWrap, Inc., demonstrates the potential of grid-enhancing technologies like WiRe Wrap to reduce sag, increase grid resiliency, and support the future energy landscape. By validating the performance of such technologies in real-world scenarios, this work provides critical insights for industry adoption, benefiting both grid operators and U.S. taxpayers through improved reliability, reduced emissions, and enhanced energy delivery.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Introduction to Microgrids

A microgrid is simply a typical power system that has distributed energy resources (DERs), like small diesel generators, with loads in the network. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. One key factor that differentiates microgrids from a typical distribution grid is its ability to disconnect itself in the event of a blackout and sustain its loads through DERs. Microgrid systems will reconnect to the main grid when the grid comes back up. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. This presentation discusses the typical key steps involved in microgrid planning, installation, operation in a interoperable and interconnectable fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lower Snake River Dams Contribution to Grid Services

Hydroelectric generation and water storage have long been components of the clean energy mix, providing both reliable steady output and operational flexibility. As variable renewable energy sources such as wind and solar increasingly replace traditional generation, the role of all flexible resources—including hydropower—in balancing supply and demand continues to evolve. This study examined the contribution of the Lower Snake River (LSR) Dam plants to Bonneville Power Administration grid services in maintaining power system reliability within the Western Interconnection. By analyzing publicly available data, the study evaluated various reliability services through performance metrics including energy capacity, balancing and ramping, voltage and reactive power support, frequency response, and transmission impact. Results indicated that the LSR plants deliver services as expected based on their size, contributing to the balancing process, ramping capabilities, and operational reserves, particularly during peak load conditions and weather events, while also providing measurable frequency and voltage support to the grid.

13 HYDRO ENERGY↗

STORM: Scrape-off layer turbulence in tokamak fusion reactors

The scrape-off layer of a tokamak fusion reactor carries the plasma exhaust from the hot core plasma to the material surfaces of the reactor vessel. The heat loads imposed by the exhaust are a critical limit on the performance of fusion power plants. Turbulent transport of the plasma regulates the width of the scrape-off layer plasma and must be modelled to understand the intensity of these heat loads. STORM is a plasma turbulence code capable of simulating three dimensional turbulence across the full scrape-off layer of a tokamak fusion reactor, using a drift reduced, collisional fluid model. STORM uses mostly finite difference schemes, with a staggered grid in the direction parallel to the magnetic field. We describe the model, geometry and initialisation options used by STORM, as well as the numerical methods, which are implemented using the BOUT++ plasma simulation framework. BOUT++ has been enhanced alongside the development of STORM, providing better support for staggered grid methods. We summarise these enhancements, including a detailed explanation of the parallel derivative methods, which underwent a major update for version 4 of BOUT++.

BOUT++↗

Distribution System Blackstart and Restoration Using DERs and Dynamically Formed Microgrids

Extreme weather events have led to long-duration outages in the distribution system (DS), necessitating novel approaches to blackstart and restore the system. Existing blackstart solutions utilize blackstart units to establish multiple microgrids (MGs), sequentially energize non-blackstart units, and restore loads. However, these approaches often result in isolated MGs. In DERs-aided blackstart, the continuous operation of these MGs is limited by the finite energy capacity of commonly used blackstart units like battery energy storage (BES)-based gridforming inverters (GFMIs). To address this issue, this article proposes a holistic blackstart and restoration framework that incorporates synchronization between dynamic MGs and the entire DS with the transmission grid (TG). To support synchronization, we leveraged virtual synchronous generator-based control for GFMIs to estimate their frequency response to load pick-up events using only initial/final quasi-steady-state points. Subsequently, a synchronization switching condition is developed to model synchronizing switches, aligning them seamlessly with a linearized branch flow problem. Finally, we designed a bottomup blackstart and restoration framework that considers the switching structure of the DS, energizing/synchronizing switches, DERs with grid-following inverters, and BES-based GFMIs with frequency security constraints. In conclusion, the proposed framework is validated in IEEE-123-bus system, considering cases with two and four GFMIs under various TG recovery instants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cost-Effective Wave Energy Harvesting System with Maximum Power Point Tracking Capability

In this paper, we propose a low-cost bidirectional four-switch inverter that transfers three-phase energy between a permanent magnet synchronous generator (PMSG) driven by a wave energy collector and the power grid or a local ac load. To achieve high control performance, the machine-side inverter uses a high-gain observer for rotor position estimation and a Lyapunov-based approach for torque control. For the gridside inverter control, we estimate the filter capacitor voltage with a model reference adaptive system and control the dc-link voltage with a Lyapunov-based energy function. We also track the maximum power point from the sea waves with an integral control law that actively matches the generator impedance with that of the wave collection device. The proposed system supports both grid-following/forming modes. We validate our control design with simulation results on a 3-kW hardware setup.

wave energy, power systems integration, control de↗

Small-Signal Analysis of Current-Limiting Grid-Forming Inverters

Grid-forming (GFM) inverters are equipped with a current limiter to protect the device during grid disturbances. Because the intervention of the current limiter can compromise the transient stability of the GFM inverter, various types of current limiter designs and additional frequency-stabilization control methods have been proposed in recent literature to aid in transient GFM inverter stability; however, the small-signal stability implications of adding these additional control blocks during, in particular, off-nominal conditions are not fully understood. To address this challenge, this paper presents a generic small-signal model of a GFM inverter that incorporates various types of current limiters and frequency stability-enhancing controls. With the proposed model, we analyze the root causes of inverter instability, which reveals two critical design trade-offs. First, due to current-limiter engagement caused by a disturbance, the GFM inverter dynamics are altered, which can lead to voltage oscillations. Second, additional frequency-stabilization controls can improve the small-signal stability of the GFM inverter, but at the cost of reduced power and voltage support to the grid. Comprehensive hardware experiments validate the theoretical concept and analysis. The findings in this work underscore the importance of incorporating both transient-response and small-signal dynamics requirements into the design procedure of GFM current limiters and frequency-stabilization controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Performance Portable, Fully Implicit Landau Collision Operator with Batched Linear Solvers

Modern accelerators use hierarchical parallel programming models that enable massive multithreading within a processing element (PE), with multiple PEs per device driven by traditional processes. Batching is a technique for exposing PE-level parallelism in algorithms that have traditionally run on MPI processes or multiple threads within a single process. Opportunities for batching arise in, for example, kinetic discretizations of magnetized plasmas where collisions are advanced in velocity space at each spatial point independently. This paper builds on previous work on a high-performance, fully nonlinear, Landau collision operator by batching the linear solver, as well as batching the spatial point problems and adding new support for multiple grids for multiscale, multispecies problems. An anisotropic relaxation verification test that agrees well with previously published results and analytical models is presented. The performance results from NVIDIA A100 and AMD MI250X nodes are presented with hardware utilization analysis for each architecture. Finally, the entire implicit Landau operator time advance is implemented in Kokkos for performance portability, running entirely on the device and is available in the PETSc numerical library.

97 MATHEMATICS AND COMPUTING↗

Physics-Based Analysis of Cell Imbalances and Aging in Lithium-Ion Battery Modules and Packs

Lithium-ion battery (LIB) packs are a key solution for grid-scale energy storage, enabling grid resilience and supporting critical infrastructure. LIB modules and packs experience current imbalances and uneven cell aging due to various design and operational factors, and require a battery management system (BMS) to continuously monitor and control. In this context, a physics-based modeling framework for LIB modules and packs (liionpack) was enhanced to identify design and control strategies that minimize current imbalance and improve module/pack operation. Simulations of an 8-cell parallel-connected module demonstrate that reducing current imbalance leads to more uniform cell aging and improved module/pack-level degradation predictions. The analysis shows that current imbalance are affected by the electrical resistances. Terminal location significantly affects imbalance, with opposite-end terminal connections at intermediate branches minimizing the imbalance, and the pack circuit construction influences the accuracy of physics-based analysis at the pack scale. This framework enables design optimization of modules and packs through a fast and easy evaluation of pack performance and aging, and supports the development of aging-informed balancing strategies compatible with BMS implementation. Thereby, offering practical pathways to improve reliability and cycle life predictions in large-scale battery energy storage systems.

Ayalasomayajula, Surya Mitra [Oak Ridge National L↗