Structural and preliminary thermal performance testing of a pressure activated contact heat exchanger

A contact heat exchanger concept is being developed for use onboard Space Station as an interface device between external thermal bus and pressurized modules. The concept relies on mechanical contact activated by the fluid pressure inside thin-walled tubes. Structural testings were carried out to confirm the technology feasibility of using such thin-walled tubes. The test results also verified the linear elastic stress analysis which was used to predict the tube mechanical behaviors. A preliminary thermal testing was also performed with liquid Freon-11 flowing inside tubes and heat being supplied by electrical heating from the bottom of the contact heat exchanger baseplate. The test results showed excellent agreement of test data with analytical prediction for all thermal resistances except for the two-phase flow characteristics. Testing with two-phase flow inside tubes will, however, be performed on the NASA-JSC test bed.

Lee, C. Y.↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Flow maldistribution in plate heat exchangers – Impact, analysis, and solutions

Plate heat exchangers are commonly used in various industrial applications, such as refrigeration, air conditioning, heat pumps, powerplants, and chemical industries. Plate heat exchangers are well known for their superior heat transfer performance, compactness, and low refrigerant charge. Despite offering several advantages, they suffer from flow maldistribution issues. The flow maldistribution can deteriorate both the heat transfer and pressure drop performance, ultimately resulting in a lower system efficiency where plate heat exchangers are deployed. The flow maldistribution issues become more pronounced when the heat exchanger size is relatively large and the number of plates is higher, limiting the deployment of plate heat exchangers in larger industrial systems. Consequently, analyzing and understanding the flow maldistribution behavior in plate heat exchangers and finding ways to mitigate flow maldistribution related issues become essential topics of interest. Further, this review aims to address the effect of flow maldistribution on plate heat exchanger characteristics. First, the experimental and numerical works on flow maldistribution under single-phase and two-phase conditions are detailed. Subsequently, the end-channel and end-plate effects are discussed. Then, the methods to mitigate flow maldistribution in plate heat exchangers are outlined. Finally, based on a thorough literature survey and industrial requirements, future research directions are recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Exchanger For Rotating Modular Structures

Heat exchanger transfers heat from one structure to another while accommodating rotary motion of structures. Flat-panel heat exchanger passes heat from fluid in middle panel to fluid in outer panels. Diaphragm-like outer panels swell to conform to surfaces of middle panel, ensuring thermal contact. Rotary fluid coupling provides connection for both supply fluid and return fluid. Flexible hoses carrying fluid to and from coupling accommodate tilt of one structure with respect to other. Adapted to transfer of fluids and heat across joints of machine tools and robot arms and to flow of coolant through portable electronic equipment.

Clark, William E.↗

Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (LCO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas is a significant heat transfer mechanism for the warming of the adsorbent bed because it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously. A NASA Small Business Innovative Research (SBIR) Phase 1 contract was performed to investigate condensing and icing as applied to MTSA to enable higher fidelity modeling and assess the impact of geometry variables on CIHX performance for future CIHX design optimization. Specifically, a design tool was created using analytical relations to explore the complex, interdependent design space of a condensing ice heat exchanger. Numerous variables were identified as having nontrivial contributions to performance such as hydraulic diameter, heat exchanger effectiveness, ventilation gas mass flow rate and surface roughness. Using this tool, four test articles were designed and manufactured to map to a full MTSA subassembly (the adsorbent bed, the sublimation heat exchanger for cooling and the condensing ice heat exchanger for warming). The design mapping considered impacts due to CIHX geometry as well as subassembly impacts such as thermal mass and thermal resistance through the adsorbent bed. The test articles were tested at simulated PLSS ventilation loop temperature, moisture content and subambient pressure. Ice accumulation and melting were observed. Data and test observations were analyzed to identify drivers of the condensing ice heat exchanger performance. This paper will discuss the analytical models, the test article designs, and testing procedures. Testing issues will be discussed to better describe data and share lessons learned. Data analysis and subsequent conclusions will be presented.

Padilla, Sebastian↗

System and method for cooling using a heat exchanger having a membrane

A heat exchanger that includes a membrane of graphene oxide is disclosed, as is a heat exchange system employing such a heat exchanger. The heat exchanger permits the use of water from non-traditional sources, such as waste water, brackish and sea water, in a cooling loop. Clean water and sensible heat permeate through the membrane, simultaneously cooling and purifying water in the cooling loop.

42 ENGINEERING↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Superhydrophobic heat exchangers delay frost formation and enhance efficency of electric vehicle heat pumps

The number of electric vehicles has rapidly expanded as high-performance automotive lithium-ion batteries have become more affordable. However, the range of electric vehicles decreases in cold climates partly because of the additional thermal loads associated with cabin heating. One way to improve the efficiency of cabin heating is to replace resistive heating elements with an air-source heat pump system. However, to gain the full benefit of heat pumping, frost formation on the outdoor heat exchanger must be minimized. In this work, we modified the surface wettability of aluminum louvered-fin automotive heat pump evaporators and tested them under realistic operating conditions in a transcritical carbon dioxide (CO 2 ) heat pump. Each heat exchanger underwent several consecutive frosting and defrosting cycles to understand the cyclic performance of the system. The heat exchanger with a superhydrophobic outer surface was able to delay frost formation and maintain higher heat transfer rates when compared to heat exchangers with higher surface energies (hydrophilic). The delayed frost formation resulted in a system efficiency benefit in the first few frosting cycles but diminished in later cycles due to water retention and incomplete defrosting. However, for most automotive applications the superhydrophobic heat exchanger showed substantial benefits for normal driving trips. We report the scalable and optimized superhydrophobic heat exchangers developed here have the potential to increase the efficiency of automotive heat pumps and consequently increase the range and reduce energy consumption of electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a prototype automated on-orbit contact heat exchanger

An automated contact heat exchanger is being developed for use aboard the manned Space Station, serving as an interface heat exchanger between the pressurized module internal thermal buses and the central external thermal bus. The concept makes use of an array of flattened, thin-walled, flexible tubes that expand or contract to make or break the thermal connection as the internal pressure changes. Because of its simplicity, it permits on-orbit assembly by the remote manipulator system, thus eliminating the need for expensive EVA to make connections. A design methodology based on stress and thermal analyses has been developed and used to perform trade-offs between performance and cost, and to optimize design parameters. Simple verification tests have been performed to confirm the stress analysis model. Two conceptual variants of the contact heat exchanger are described, each designed for a 25 kW total heat load and a minimum uniform heat flux of 2.15 W/sq cm.

Lee, C. Y.↗

Laser Processed Heat Exchangers

The Laser Processed Heat Exchanger project will investigate the use of laser processed surfaces to reduce mass and volume in liquid/liquid heat exchangers as well as the replacement of the harmful and problematic coatings of the Condensing Heat Exchangers (CHX). For this project, two scale unit test articles will be designed, manufactured, and tested. These two units are a high efficiency liquid/liquid HX and a high reliability CHX.

Hansen, Scott↗

Slotting Fins of Heat Exchangers to Provide Thermal Breaks

Heat exchangers that include slotted fins (in contradistinction to continuous fins) have been invented. The slotting of the fins provides thermal breaks that reduce thermal conduction along flow paths (longitudinal thermal conduction), which reduces heat-transfer efficiency. By increasing the ratio between transverse thermal conduction (the desired heat-transfer conduction) and longitudinal thermal conduction, slotting of the fins can be exploited to (1) increase heat-transfer efficiency (thereby reducing operating cost) for a given heat-exchanger length or to (2) reduce the length (thereby reducing the weight and/or cost) of the heat exchanger needed to obtain a given heat transfer efficiency. By reducing the length of a heat exchanger, one can reduce the pressure drop associated with the flow through it. In a case in which slotting enables the use of fins with thermal conductivity greater than could otherwise be tolerated on the basis of longitudinal thermal conduction, one can exploit the conductivity to make the fins longer (in the transverse direction) than they otherwise could be, thereby making it possible to make a heat exchanger that contains fewer channels and therefore, that weighs less, contains fewer potential leak paths, and can be constructed from fewer parts and, hence, reduced cost.

Scull, Timothy D.↗

Joining Study for Formed Plate Heat Exchangers (Final Report)

Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.

36 MATERIALS SCIENCE↗

Parametric Modeling and Economic Analysis of a 2MW th 3-Stream sCO 2 Heat Exchanger

Here, this paper presents the design and cost optimization of a novel 2MW th 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that it uses reduced metal oxide particle-to-sCO2 heat exchanger for cost-effective energy storage applications. The design uses low velocity, laminar air as the re-oxidizing reactant to transfer the heat of the re-oxidizing reaction to a sCO2 power loop. The design of the heat exchanger is based on a 2-D, 3-fluid plate/fin heat transfer model. The model parameterizes the size, shape, and number of passages of the heat exchanger to calculate the temperature profile, pressure drop, and fluid velocities of all three fluids. Global heat exchanger parameters such as the effectiveness and total heat transferred to the sCO2 are then calculated for overall performance. Due to the value and increased use of sCO2 heat exchangers in power cycles, a cost model of the system based on the unique high temperature/high pressure operating conditions was created using quotes from reference projects and market analysis. These quoted air-to-sCO2 heat exchangers are then processed using multiple weighting factors pertinent to heat exchanger design, including heat exchanger type, maximum temperature, differential pressures, fluids, duty, and more. These factors are then used in an exponential function in order to generate a parameterized cost curve. The design and cost of the heat exchanger are then optimized using the SMPSO genetic algorithm in Python. The optimization objectives for the system are to maximize the overall system effectiveness, including an air recuperator for preheating, and to minimize unit costs. Additional constraints are added to the system for the sCO2 and air pressure drops, air velocity to reduce particle entrainment, and the length and volume of the heat exchanger.

Cost Model↗

Fitness for Service Assessment of a Corroded Heat Exchanger

Fermilab s Main Injector Accelerator has used shell & tube heat exchangers to cool various beamline components since its construction in the late 1990s. Many of the heat exchangers still around today are original to the machine. Untreated pond water has been used to exchange heat with the Low Conductivity Water. Throughout the lifetime of Fermilab s heat exchangers, they have undergone significant material degradation in the carbon steel end channels due to corrosion. Wall thickness measurements (per API 510) of each heat exchanger were used to generate a 3D model of the corroded surfaces. In order to continue their safe and reliable operation, ASME FFS-1/API 579 (Fitness-For-Service) was implemented to address their integrity. The assessments consisted of finite element analysis techniques outlined in ASME Section VIII Div. 2 (design by analysis methods for pressure vessels), in accordance with the requirements of ASME FFS-1 Part 4: General Metal Loss, Part 5: Local Metal Loss, and Part 9: Crack Like Flaws. The assessments concluded that each heat exchanger is coined Fit For Service . The Fitness-For-Service standard offers a unique opportunity to facilities and institutions within the DOE National Lab complex to properly and safely assess the integrity of aging equipment necessary to conduct science and research. This poster demonstrates the assessment process and techniques used to determine the heat exchangers are fit for service.

Humenik, Alex [Fermilab]↗