Numerical Simulation of Light to Heat Conversion by Plasmonic Nanoheaters

Plasmonic nanoparticles are widely recognized as photothermal conversion agents, i.e., nanotransducers or nanoheaters. Translation of these materials into practical applications requires quantitative analyses of their photothermal conversion efficiencies (η). However, the value of η obtained for different materials is dramatically influenced by the experimental setup and method of calculation. Here, we evaluate the most common methods for estimating η (Roper’s and Wang’s) and compare these with numerical estimates using the simulation software ANSYS. Experiments were performed with colloidal gold nanorod solutions suspended in a hanging droplet irradiated by an 808 nm diode laser and monitored by a thermal camera. The ANSYS simulations accounted for both heating and evaporation, providing η values consistent with the Wang method but higher than the Roper approach. This study details methods for estimating the photothermal efficiency and finds ANSYS to be a robust tool where experimental constraints complicate traditional methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC

Utilities and grid operators worldwide are under significant pressure to incorporate intermittent renewable sources while strategizing on how to maintain the necessary stability and reliability of the grid. The development of a power plant which will be capable of flexible operation to meet the needs of the grid as more intermittent sources like wind and solar energy are incorporated is key to maintain the reliability of the grid. Through the use of innovative and cutting-edge technologies that improve efficiency and reduce carbon emissions, and being small compared to today's conventional utility-scale power plants, the modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. Specifically, the process offers: 1) a modular plant design that allows for better operational flexibility; 2) the utilization of fuel-staging and pressurized oxy-combustion, resulting in smaller plant size, improved plant efficiency, and reduced costs for pollutant and CO2 removal compared to traditional power plants with post-combustion capture technology; and 3) the use of small modular boilers and pollutant removal units that can be constructed off-site leading to reduced capital costs for the plant. WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustor-boiler system and the direct contact cooler. To demonstrate the boiler convective section and to obtain critical data for commercial-scale pressurized boiler design, a simulated convective heat transfer boiler test section was designed and integrated with the combustor (radiant section). A direct contact cooler (DCC) was integrated with the combustor-boiler to demonstrate the dynamic operation of the integrated system and the performance of the DCC, including the efficiency for simultaneous removal of NOx and SOx. This talk will present an update on the evaluation of the critical components for system integration, including heat transfer data from the simulated boiler, scrubbing efficiency for the DCC under different operating conditions, and CFD modeling and validation for burner and boiler development.

Magalhaes, Duarte↗

Quantification of Residual Water in Spent Fuel Dry Storage Canisters Using Mass Spectrometry

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal, such as fuel degradation; cladding corrosion, embrittlement, or breaching; and the creation of a flammable environment via radiolysis of water. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents details on the quantification of residual water in the Advanced Drying Cycle Simulator (ADCS), an apparatus built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. The ADCS is outfitted with thermocouples to measure the thermal response of the ADCS to simulated decay heats and internal helium fill pressures relevant to commercial drying procedures. The ADCS is also instrumented with pressure transducers to measure the pressures and vacuum levels observed during simulated commercial drying. The most unique instrumentation used for quantifying residual water in the ADCS is a Hiden Analytical HPR-30 mass spectrometer (MS), which measures gas compositions of the ADCS internal free volume, based on partial pressures calculated from relative proportions of gas molecules detected by the MS. This report details the methodology used to implement MS measurements in quantifying residual water in the ADCS. This methodology includes the calibration of the HPR-30 MS to a Buck Research Instruments CR-4 chilled mirror hygrometer, which itself is calibrated to a NIST-traceable standard. Data collected by both the MS and the chilled mirror hygrometer from water/helium mixtures ranging from 150 to 500,000 ppmv water in helium were used to generate calibration curves, establishing a source of verification of MS measured water contents. Details regarding water content measurement uncertainties are included in this report, defining the accuracy and verifiability of the HPR-30 MS in measuring residual water content in simulated dry storage canister environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Nonnuclear Experimental Capabilities to Support Design, Development, and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support nonnuclear testing and demonstration of technology in support of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the Single Primary Heat Extraction and Removal Emulator (SPHERE) and the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes noncontact infrared thermal imaging, surface thermocouples, spatially distributed fiber optic temperature and strain sensors, electrical power meters, and a water-cooled, gas-gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions. The MAGNET facility is a large-scale, 250-kW electrically heated microreactor test bed to enable nonnuclear experimental evaluation of a variety of microreactor concepts. It can be supplied to electrically heat a scaled section of a microreactor and further test the capabilities of heat rejection systems. The initial MAGNET experiments will support technology maturation and reduce uncertainty and risk associated with the design, operation, and deployment of monolithic heat pipe–based reactors. However, this test bed can broadly be applied to multiple microreactor concepts to evaluate a wide range of thermal-hydraulic and structural phenomena such as interface coupling with power conversion units and other collocated systems. MAGNET can evaluate integral thermomechanical effects during electrical heating of an array of heat pipes in a larger test article. Examples of initial testing will include thermal stresses in the monolith and the impact of debonding of a heat pipe from the core block and how that failure could impact surrounding heat pipes, i.e., understanding the potential for cascading failure. This work also discusses some modeling capabilities that can support experiment design, analysis, and interpretation, including the heat pipe code Sockeye and a comparison of thermal-structural simulations performed using ABAQUS and STAR-CCM+.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Collaborative Research: Vlasov–Maxwell Simulations to resolve electron heating and dissipation, in quasiperpendicular shocks (Final Technical Report)

The project is to study electron heating at quasi-perpendicular shocks. We have analyzed measurements from the Magnetosphere Multiscale (MMS) spacecraft and particle-in-cell simulations to address the question. One key discovery is that waves and are excited in the shock transition region, which further develop into complicated structures and thin current layers, which contribute to accelerate and heat electrons. We further investigated the excitation and evolution of these waves and structures, and their association with ion and electron dynamics. In addition, the analysis technique of Vlasov equation terms is further applied to study electron dynamics at the dayside magnetopause, to understand the effect of density, velocity and temperature variations on electron distributions and kinetics.

58 GEOSCIENCES↗

Collaborative Research: Vlasov-Maxwell Simulations to Resolve Electron Heating and Dissipation, in Quasi-Perpendicular Shocks (Final Report)

Collisionless shocks are a grand challenge problem in plasma physics and have been the subject of study for more than six decades. Shocks are ubiquitous phenomena in the universe and are responsible for transforming high energy and momentum flows into thermal energy and energetic particles. Understanding how shocks operate is of primary importance to understand the sun-earth coupling, protecting manned missions and spacecrafts from high energy particles, inertial confinement fusion, and radiation observed from astrophysical plasmas, such as supernova remnants and astrophysical jets. A major unanswered question on this frontier is, how does a collisionless plasma transform flow energy and momentum into electron thermal energy? Many potential mechanisms have been proposed to perform the conversion between flow and thermal energy in a collisionless plasma, but the answer has been elusive. To solve the mystery, non-relativistic perpendicular and quasi-perpendicular shocks are studied via a coordinated approach employing cutting-edge numerical simulations with the continuum kinetic code Gkeyll and spacecraft observations supplied by NASA's Magnetospheric Multiscale (MMS) mission. In both sets of data, we employ novel techniques to identify how and where energy is exchanged between electromagnetic fields and plasma particles. By combining cutting-edge spacecraft data and numerical simulations with these diagnostics, we have been able to identify some of the primary mechanisms responsible electron heating and dissipation in heliospheric shocks. In addition to electron dynamics, we have complete access to proton simulation and in situ data, enabling us to characterize proton heating and acceleration in quasi-perpendicular shocks. Many astrophysical quasi-perpendicular shocks have similar parameters to those in this study, including supernova remnants and shocks in galaxy clusters. Additionally, the simulation code, Gkeyll, and associated analysis scripts are openly available for community use. This award has supported a collaborative effort between Princeton University, the University of Arizona - Tucson, and the University of Maryland - College Park. The award funded three early career scientists, including the funding and training of one female postdoctoral researcher, who was involved in all aspects of the MMS data analysis and some portions of the simulation analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Autonomous Controls For Reactor Technologies (acorn)

ACORN (Autonomous Controls fOr Reactor techNologies) software utilizes data, obtained from an experimental test bed and/or simulation, to implement a control command for microreactor operation. Command examples include a change to the temperature profile, power profiles, heat fluxes, etc. The control command recommended by the code is derived based on future predicted states of a microreactor, allowing proactive optimal and autonomous microreactor operation. The software is written in Python languages. The current software supports autonomous temperature controls of heat pipe simulator and autonomous heat flux controls of a 37 heat pipe non-nuclear testbed simulator (or its surrogate models).

Lin, Linyu [Idaho National Laboratory (INL), Idaho↗

Collaborative Research: Vlasov-Maxwell Simulations to Resolve Electron Heating and Dissipation, in Quasi-Perpendicular Shocks

The major goals of the project are to study three fundamental questions related to collisionless, non-relativistic, quasi-perpendicular shocks by combining continuum Vlasov-Maxwell simulations (the Gkeyll framework) and high resolution, in situ heliospheric observations from the MMS spacecraft. The specific questions are: 1. How and where are electrons energized and heated in a quasi-perpendicular shock, including the ultimate source of entropy production? 2. What role do waves, turbulence, and secondary instabilities play in the conversion of directed flow energy to electron energy? 3. How do the parameters of the shock determine the energization of electrons?

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Butterfly valve performance factors using the multiphysics object oriented simulation environment

Butterfly valves are typically used in nuclear reactors to control incompressible fluid flow with high inlet velocities. Performance factors for butterfly valves include the pressure drop across the valve and the loss coefficient from which hydrodynamic torque and flow coefficients can be computed. This work explores a computational fluid dynamics approach for butterfly valve performance factors using the open-source Multiphysics Object Oriented Simulation Environment (MOOSE) framework. While MOOSE is often used in the nuclear energy modeling and simulation community for simulations ranging from fuel characterization to heat pipe simulation, this work employs the MOOSE open-source Navier–Stokes solver capability for simulating butterfly valve performance factors and compares those to experimentally measured results from the Advanced Test Reactor at Idaho National Laboratory at Reynolds numbers in the order of 10 6 for the partially opened configuration. The MOOSE framework results are compared against experimentally measured butterfly valve performance factors across five valve opening angles using meshes with order 10 4 – 10 5 elements. This validation serves to enable MOOSE-based multiphysics simulations incorporating the open-source Navier–Stokes module.

97 - MATHEMATICS AND COMPUTING↗

Experimental Capabilities to Support Design, Development and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support non-nuclear demonstration of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the single primary heat extraction and removal emulator (SPHERE) and the microreactor agile non-nuclear experimental test bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes non-contact infrared thermal imaging, surface thermocouples, spatially distributed fiber-optic temperature and strain sensors, electrical power meters, and a water-cooled, gas gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions.

42 ENGINEERING↗

A Simulation Study of 120V Heat Pump Water Heaters

A 120 V heat pump water heater (HPWH) is a direct plug-in option to replace gas water heater (WH) without needing expensive electric panel upgrade to 220 V. To enable the smooth transition, the HPWH should provide comparable water heating capacity as the gas WH. WH capacities are rated in the form of first hour rating (FHR). Typical home gas WHs have FHRs > 65 gallon with a 40-gallon water tank. It imposes a major challenge on 120V HPWHs. Most 120V circuits in US can provide 1,800 to 2,400W, not adequate to drive electric resistance heat to boost FHRs. Thus, all the heat needs to come from the heat pump with its top power below 1500 Watts, which is constraint by the installation footprint. This study uses a hardware based, HPWH design model, i.e. the DOE/ORNL Heat Pump Design Model to design a 120V unit with a brazed plate condenser, fin-and-tube evaporator and an adequately sized compressor. To maximize the FHR, multiple strategies were simulated, including use of a mixing valve, overheating the tank temperature to 140F, a new sensing method for quicker response, and an innovative water circulation path. We also simulated 24-hour unform energy factors (UEF) to show the tradeoff between the capacity and operation efficiency. Additionally, we evaluated the impact of insulation thickness on FHR and UEF, to seek further footprint reduction or stretch the tank volume.

Shen, Bo↗

Effects of organized convection parameterization on the MJO and precipitation in E3SMv1. Part I: Mesoscale heating

Mesoscale organization of convection is typically not represented in global circulation models, and hence its influence on the global circulation is not accounted for. The heating component of a parameterization that represents the dynamical and physical effects of circulations associated with organized convection, referred to as the multiscale coherent structure parameterization (MCSP), is implemented in the Energy Exascale Earth System Model version 1 (E3SMv1). Numerical simulations are conducted to assess its impact on the simulated climate. Besides E3SMv1 simulations, we performed high-resolution (1 km) simulations using the Weather Research and Forecasting (WRF) Model to determine the temperature tendencies induced by mesoscale convective systems embedded in deep convection. We tuned the free parameters of the MCSP based on the WRF simulations. MCSP heating enhances Kevin wave spectra in E3SMv1, improves the representation of the Madden-Julian Oscillation, and impacts on mean precipitation that vary with locations and seasons, including a reduction of biases over the tropical Pacific.

Climate Modeling↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Drying Cycle Simulator Thermal Response to Commercial Drying Conditions

The purpose of this report is to document updates on testing of the apparatus built to simulate commercial drying procedures for spent nuclear fuel at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention that incorporate relevant physics and well-controlled boundary conditions. This report documents testing updates for the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. This report describes preliminary testing of the ADCS through measurement and analysis of the thermal response of the system to a subset of commercial drying conditions that exclude the introduction of water, namely simulated decay heats and pressures relevant to commercial drying. This test series, referred to as a “dry” test series in this report, spans three uniform waterproof heater rod powers (representing spent fuel decay heats), four helium fill pressures, and six vacuum levels. This test series was conducted to cover the range of expected ADCS testing conditions for upcoming “wet” testing, where water will be introduced and a simulated commercial drying cycle will be performed. The dry test conditions were derived from the commercial drying conditions seen in the High Burnup Demonstration and the vacuum drying conditions chosen for a smaller scale Dashpot Drying Apparatus tested at Sandia National Laboratories in FY22. For a given uniform power and pressure/vacuum level, the ADCS was operated at constant power and pressure and allowed to reach steady state conditions. The thermal data obtained from these tests were analyzed, and the results can inform computational models built to simulate commercial drying processes by providing baseline thermal data prior to the introduction of water. Following the preliminary dry tests, a test plan for the ADCS will be developed to implement a drying procedure that begins with the introduction of water to the system and is based on measurements from the drying process used for the High Burnup Demonstration Project. While applying power to the simulated fuel rods, this procedure is expected to consist of filling the ADCS vessel with water, draining the water with applied pressure and multiple helium blowdowns, evacuating additional water with a vacuum drying sequence at successively lower pressures, and backfilling the vessel with helium. Additional investigations are expected to feature failed fuel rod simulators with engineered cladding defects and guide tubes with obstructed dashpots to challenge the drying system with multiple water retention sites. The data from these investigations is expected to inform the efficacy of commercial drying operations through the quantification of residual water in a prototypic-length dry storage canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

When should PIC simulations be applied to atmospheric pressure plasmas? Impact of correlation heating

Abstract Molecular dynamics simulations are used to test when the particle-in-cell (PIC) method applies to atmospheric pressure plasmas. It is found that PIC applies only when the plasma density and macroparticle weight are sufficiently small because of two effects associated with correlation heating. The first is the physical effect of disorder-induced heating (DIH). This occurs if the plasma density is large enough that a species (typically ions) is strongly correlated in the sense that the Coulomb coupling parameter exceeds one. In this situation, DIH causes ions to rapidly heat following ionization. PIC is not well suited to capture DIH because doing so requires using a macroparticle weight of one and a grid that well resolves the physical interparticle spacing. These criteria render PIC intractable for macroscale domains. The second effect is a numerical error due to artificial correlation heating (ACH). ACH is like DIH in that it is caused by the Coulomb repulsion between particles, but differs in that it is a numerical effect caused by a macroparticle weight larger than one. Like DIH, it is associated with strong correlations. However, here the macroparticle coupling strength is found to scale as Γ w 2 / 3 , where Γ is the physical coupling strength and w is the macroparticle weight. So even if the physical coupling strength of a species is small, as is expected for electrons in atmospheric pressure plasmas, a sufficiently large macroparticle weight can cause the macroparticles to be strongly coupled and therefore heat due to ACH. Furthermore, it is shown that simulations in reduced dimensions exacerbate these issues.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗