Search NASA⌕ Search

SEARCH · Search NASA

Results for “heating and current drive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Heating of the solar middle chromosphere by large-scale electric currents

A global resistive, two-dimensional, time-dependent magnetohydrodynamic (MHD) model is used to introduce and support the hypothesis that the quiet solar middle chromosphere is heated by resistive dissipation of large-scale electric currents which fill most of its volume. The scale height and maximum magnitude of the current density are 400 km and 31.3 m/sq m, respectively. The associated magnetic field is almost horizontal, has the same scale height as the current density, and has a maximum magnitude of 153 G. The current is carried by electrons flowing across magnetic field lines at 1 m/s. The resistivity is the electron contribution to the Pedersen resitivity for a weakly ionized, strongly magnetized, hydrogen gas. The model does not include a driving mechanism. Most of the physical quantities in the model decrease exponentially with time on a resistive timescale of 41.3 minutes. However, the initial values and spatial; dependence of these quantities are expected to be essentially the same as they would be if the correct driving mechanism were included in a more general model. The heating rate per unit mass is found to be 4.5 x 10(exp 9) ergs/g/s, independent of height and latitude. The electron density scale height is found to be 800 km. The model predicts that 90% of the thermal energy required to heat the middle chromosphere is deposited in the height range 300-760 km above the temperature minimum. It is shown to be consistent to assume that the radiation rate per unit volume is proportional to the magnetic energy density, and then it follows that the heating rate per unit volume is also proportional to the energy from the photosphere into the overlying chromosphere are briefly discussed as possible driving mechanisms for establishing and maintaining the current system. The case in which part of or all of the current is carried by protons and metal ions, and the contribution of electron-proton scattering to the current are also considered, with the conclusion that these effects do not change the qualitative prediction of the model, but probably change the quantitative predictions slightly, mainly by increasing the maximum magntiude of the current density and magnetic field to at most approximately 100 mA/m and approximately 484 G, respectively. The heating rate per unit mass, current density scale height, magnetic field scale height, temperatures, and pressures are unchanged or are only slightly changed by including these additional effects due to protons and ions.

Goodman, M. L.↗

Pressure-driven tearing and thermal transport in finite-beta reversed field pinch computations

In this work, nonlinear resistive-magnetohydrodynamics (MHD) computation with heating and anisotropic transport is applied to examine the interaction between thermal energy and magnetic fluctuations in inductively driven reversed-field pinches (RFPs). The magnetic fluctuations underlie magnetic field reversal through dynamo-like correlations, and they enhance thermal energy transport through fluctuations of parallel heat flux density. With the unfavorable magnetic curvature that exists across the RFP profile, thermal energy also affects the magnetic fluctuations. Computations with the NIMROD code [Sovinec et al., J. Comput. Phys. 195, 355–386 (2004)] integrate nonlinear MHD dynamics with energy transport and reproduce an RFP state with experimentally relevant values of plasma-β. Equilibria constructed from results of the 3D computations are analyzed to assess the sources of free energy in the saturated nonlinear state. Linear computations for these profiles show unstable modes of tearing parity. Their eigenfunctions are used to evaluate and compare stabilizing and destabilizing contributions to the kinetic energy integral. An assessment of the drives in the integral reveals that the pressure gradient drive is of comparable magnitude to the parallel current drive, and only the sum of the two surpasses the stabilizing contributions. Correlation of magnetic and parallel heat flux density fluctuations in the nonlinear computations shows that fluctuation-induced thermal conduction is the dominant mode of energy loss, as expected from experimental evidence. Decomposition of the fluctuating heat flux density shows that second-order correlations, alone, do not explain the total energy transport. Higher-order correlations are also important.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed contact glow discharge electrification for online material quantification

Real-time elemental analysis of liquids in extreme environments remains a significant challenge for sensor development, particularly in applications such as advanced nuclear reactors. Plasma-based optical emission spectroscopy offers a promising solution. In this study, we investigate pulsed contact glow discharge electrolysis (CGDE) as an alternative plasma generation method for emission-based material quantification. Using aqueous NaCl solutions, we examine the role of discharge polarity on plasma behavior, emission characteristics, and spectral output. Our results demonstrate that cathodic discharges generate more energetic plasmas, enabling the detection of ionic species such as cerium, while anodic discharges favor atomic emission. These findings reveal a potential dual-mode sensing capability controlled by circuit configuration rather than hardware changes. Through synchronized measurements of emission, current, bubble, and spectral dynamics, we present a model in which electron emission and ohmic heating drive plasma formation. This model enhances our understanding of pulsed-CGDE and supports its potential as a versatile, adaptable platform for future deployment in high-temperature liquids such as molten salts.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Solar-Driven Liquid-Metal MHD Generator

Liquid-metal magnetohydrodynamic (MHD) power generator with solar oven as its heat source has potential to produce electric power in space and on Earth at high efficiency. Generator focuses radiation from Sun to heat driving gas that pushes liquid metal past magnetic coil. Power is extracted directly from electric currents set up in conducting liquid. Using solar energy as fuel can save considerable costs and payload weight, compared to previous systems.

Hohl, F.↗

The generation of rapid solar flare hard X-ray and microwave fluctuations in current sheets

The generation of rapid fluctuations, or spikes, in hard X-ray and microwave bursts via the disruption of electron heating and acceleration in current sheets is studied. It is found that 20 msec hard X-ray fluctuations can be thermally generated in a current sheet if the resistivity in the sheet is highly anomalous, the plasma density in the emitting region is relatively high, and the volume of the emitting region is greater than that of the current sheet. A specific mechanism for producing the fluctuations, involving heating in the presence of ion acoustic turbulence and a constant driving electric field, and interruption of the heating by a strong two-stream instability, is discussed. Variations upon this mechanism are also discussed. This mechanism also modulates electron acceleration, as required for the microwave spike emission. If the hard X-ray emission at energies less than approx. 1000 keV is nonthermal bremsstrahlung, the coherent modulation of electron acceleration in a large number of current sheets is required.

Holman, Gordon D.↗

Core Losses in Co-Rich Inductors with Tunable Permeability

High frequency, low loss power systems enable electrified aircraft propulsion. Filter inductors that reduce noise in high current systems can account for 50% of the motor drive mass. Efficient inductor cores with tunable permeability reduce system mass by producing less heat, that removes heat sink mass. Requirements for filter inductors vary based on the chosen topology, but all inductor cores must operate below saturation levels. As the saturation flux density is limited (less than ~2 T), high differential current applications require cores with low relative permeabilities. The large induced anisotropies possible in Co-rich metal amorphous nanocomposite materials enables gapless inductors with relative permeabilities down to ~20. These materials have fine grain size ~8nm with a faulted, close packed structure. The impact of different processing methods on core losses are presented along with comparison to other low permeability soft magnetic materials.

Leary, Alex↗

Lightweight Memory-Metal Pin Puller

Memory-metal pin puller designed for use in aperture-cover mechanism of camera aboard spacecraft adapted to small-volume instrument environments that must be kept free of contamination. Includes memory-metal wires pulling pin when heated. Small and light in weight, uses relatively simple electronic drive circuitry consisting of timed source of current. Adapted to operate at cryogenic temperatures and in vacuum as well as in normal-temperature environment, cycled large number of times without degradation of performance.

Ford, Virginia G.↗

Magnetic probe diagnostics of nonlinear standing waves and bulk ohmic electron power absorption in capacitive discharges

It is recognized that standing wave effects appearing in large-area, very-high-frequency capacitively coupled plasma (CCP) reactors cause center-high plasma non-uniformity. Using a high-frequency magnetic probe, we present a direct experimental diagnostic of the nonlinear standing waves and bulk ohmic electron power absorption dynamics in low pressure CCP discharges for different driving frequencies of 13.56, 30, and 60 MHz. The design, principle, calibration, and validation of the probe are described in detail. Spatial structures of the harmonics of the magnetic field, determined by the magnetic probe, were used to calculate the distributions of the harmonic current and the corresponding ohmic electron power deposition, providing insights into the behavior of nonlinear harmonics. At a low driving frequency, i.e. 13.56 MHz, no remarkable nonlinear standing waves were identified and the bulk ohmic electron power absorption was observed to be negligible. Here, the harmonic magnetic field/current was found to increase dramatically with the driving frequency, due to decreased sheath reactance and more remarkable nonlinear standing waves at a higher driving frequency, leading to the enhancements of the ohmic heating and the plasma density in the bulk, specifically at the electrode center. At a high driving frequency, i.e. 60 MHz, the high-order harmonic current density and the corresponding ohmic electron power absorption exhibited a similar node structure, with the main peak on axis, and one or more minor peaks between the electrode center and the edge, contributing to the center-high profile of the plasma density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time dependent model for non-inductive ECH X-I current ramp-up for SHPD tokamak facility

Non-inductive (NI) plasma current start-up and ramp-up is an important research topic for spherical tokamak (ST) based reactors and fusion pilot plant (FPP). For a compact FPP, the OH flux availability is highly restricted due to its compact geometry. Efficient fundamental extraordinary mode (X-I) electron cyclotron heating (ECH) current start-up and ramp-up regime was identified for a reactor-like high toroidal magnetic field range which has more than a hundred times higher current drive efficiency compared to more conventional ECH methods for the relevant start-up temperature range. High current drive efficiency is possible due to the strong X-I fundamental ECH interaction only with unidirectional passing electrons constrained by the wave accessibility conditions. Here, we extend the X-I electron cyclotron current drive (ECCD) investigation to a time dependent model to simulate the non-inductive current ramp-up to 10 MA for the Sustained High-Power Density (SHPD) facility. As the X-I ECCD driven current I EC rises, due to the back EMF driven negative current, the net plasma current Ip rises more slowly with the current resistive time scale. For tokamak confinement time (both L-mode and H-Mode) which tends to rise with I p , a positive feedback results and even with constant applied ECH power, T e0 , I EC , and I p can continue to rise to very high values. However, in a realistic situation, the T e0 rise should saturate due to a number of factors such as enhanced core radiation and increased power loss at high temperature. To simulate this effect, we adopt a maximum T e0 model which would limit the temperature rise to certain T e0 . With this model, we investigated the current ramp-up for various ECH power levels and the maximum T e0 of 15, 20, and 25 keV. We find that while the power required is reduced with increasing T e0 limit due to increased current drive efficiency, the time to reach 10 MA tends to go up due to the reduced plasma resistivity for the higher T e0 limit. We also find for a given Te0 limit, the time to reach 10 MA tends to be reduced by increasing the applied ECH power by over driving the current ramp-up where I EC is driven at significantly higher level than 10 MA. While the current ramp-up time may not be an issue for the steady-state reactor systems, if it is desirable to minimize the current ramp-up time, it is prudent to have a sufficient ECH power for current over-drive and have some T e0 limiting tools such as impurity seeding for enhanced radiation. In conclusion, a well-controlled NI ECH start-up also has a potential of improving the tokamak start-up reliability and avoid run-away electrons while the NI off-axis current drive could enhance MHD stability and plasma performance improvements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar-Powered Refrigeration System

A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure. and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

Ewert, Michael K.↗

Solar Powered Refrigeration System

A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

Michael K Ewert↗

Solar-Powered Refrigeration System

A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

Michael K Ewert↗

Drought and Heat Waves: The Role of SST and Land Surface Feedbacks

Drought occurs on a wide range of time scales, and within a variety of different types of regional climates. At the shortest time scales it is often associated with heat waves that last only several weeks to a few months but nevertheless can have profound detrimental impacts on society (e.g., heat-related impacts on human health, desiccation of croplands, increased fire hazard), while at the longest time scales it can extend over decades and can lead to long term structural changes in many aspects of society (e.g., agriculture, water resources, wetlands, tourism, population shifts). There is now considerable evidence that sea surface temperatures (SSTs) play a leading role in the development of drought world-wide, especially at seasonal and longer time scales, though land-atmosphere feedbacks can also play an important role. At shorter (subseasonal) time scales, SSTs are less important, but land feedbacks can play a critical role in maintaining and amplifying the atmospheric conditions associated with heat waves and short-term droughts. This talk reviews our current understanding of the physical mechanisms that drive precipitation and temperature variations on subseasonal to centennial time scales. This includes an assessment of predictability, prediction skill, and user needs at all time scales.

Schubert, Siegfried↗

Baseline tests of the Kordesh hybrid passenger vehicle

Performance test results are presented for a four-passenger Austin A40 sedan that was converted to a heat-engine-alternator-and battery-powered hybrid. It is propelled by a conventional, gasoline-fueled, heat-engine-driven alternator and a traction pack powering a series-wound, 10 hp direct-current electric drive motor. The 16 hp gasoline engine drives the 7 kilowatt alternator, which provides electrical power to the drive motor or to the 96 volt traction battery through a rectifier. The propulsion battery consists of eight 12 volt batteries connected in series. The electric motor is coupled to a four-speed standard transmission, which drives the rear wheels. Power to the motor is controlled by a three-step foot throttle, which actuates relays that control armature current and field excitation. Conventional hydraulic brakes are used.

Soltis, R. F.↗

Heat Stress to Jeopardize Crop Production in the US Corn Belt Based on Downscaled CMIP5 Projections

CONTEXT Global food security faces increasing challenges from the changing climate. Changes of agricultural output from some of the most productive regions such as the US Corn Belt can largely affect the world's food market. Developing predictive understanding of the agricultural risk of climate change and potential mitigation strategies is critical for the global food security. OBJECTIVE The objective of this study is to assess the responses of maize and soybean yield to projected climate changes in the Corn Belt, identify the shifting environment stressors on crop yield, and tackle potential climate adaptation strategies. METHODS We drive a process-based model, the Decision Support System for Agrotechnology Transfer, with high-resolution statistically downscaled and bias-corrected historical and future climates from ten CMIP5 models in the MACA-2 database. RESULTS AND CONCLUSIONS The multi-model ensemble mean suggests a 12% decrease of maize yield by mid-century and 40% by late century, with a high degree of model consensus in the direction of changes; for individual models, the projected decrease of maize yield by late century ranges from <5% to over 80%, with the worst crop outcome corresponding to the most sensitive climate models. Soybean yield is projected to increase by midcentury with a high degree of model consensus, but such consensus is lost by late century as some projections shift to significant decreases. Crop yield in the Corn Belt is currently limited by water stress, but is projected to be increasingly limited by heat stress as well after the midcentury. The mounting heat stress will drive the most productive zone for maize to shift from central to northern part of the Corn Belt, but the projected increase in the northern states cannot fully compensate for the decrease in the south, causing the total production to decrease if agricultural practice stays the same. Earlier planting can alleviate only a small fraction of the heat-induced crop loss in a warmer climate. Climate change will (at least partially) offset the yield boost caused by agricultural technology and intensification. SIGNIFICANCE This study advances our predictive understanding of crop yield responses to climate change, and suggests that a multitude of strategies will be needed to address the climate change challenges for the U.S. agriculture.

Crop yield↗

Constraining computational modeling of indirect drive double shell capsule implosions using experiments

Double shell capsule implosions are an alternative approach to achieving alpha heating on the National Ignition Facility. Current machining techniques construct the outer shell as two hemispheres that are glued together, and the deuterium and tritium (DT) liquid inside the inner shell will be injected by a fill tube. These features introduce asymmetries and jetting that may disrupt the confinement of the DT fuel if not carefully controlled. Simulations indicate that in order to achieve high yields in the laboratory, these features as well as susceptibility to the Rayleigh–Taylor instability (RTI) must be mitigated. Furthermore, due to uncertainties in computational models and the expense of using the best physics models at adequate resolution in three dimensions, our computational modeling must be constrained by experiments. We report on the results of recent hydrogrowth radiography and dual-axis keyhole experiments with double shell targets that have been used to evaluate our modeling of the outer shell joint as well as the impacts of high-energy x-ray preheat that strongly impacts RTI growth. Our simulations show good agreement with the experimental data and inform several important modeling choices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam modulation and bump-on-tail effects on Alfvén eigenmode stability in DIII-D

Beam modulation effects on Alfvén eigenmode stability have been investigated in a recent DIII-D experiment and show that variations in neutral beam modulation period can have an impact on the beam driven Alfvén eigenmode spectrum and resultant fast ion transport despite similar time-averaged input power. The experiment was carried out during the current ramp phase of L-mode discharges heated with sub-Alfvénic 50–80 kV deuterium neutral beams that drive a variety of Alfvén eigenmodes unstable. The modulation period of two interleaved beams with different tangency radii was varied from shot to shot in order to modify the relative time dependent mix of the beam pitch angle distribution as well as the persistence of a bump-on-tail feature near the injection energy (a feature confirmed by imaging neutral particle analyzer measurements). As the beam modulation period is varied from 7 ms to 30 ms on/off (typical full energy slowing down time of τ slow ≈ 50 ms at mid-radius), toroidicity-induced Alfvén eigenmodes (TAEs) located in the outer periphery of the plasma become intermittent and coincident with the more tangential beam. Core mode activity changes from reversed shear Alfvén eigenmodes (RSAEs) to a mix of RSAE and beta-induced Alfvén eigenmodes. Discharges with 30 ms on/off period do not have a persistent bump-on-tail feature, have the lowest average mode amplitude and least fast ion transport. Furthermore, detailed analysis of an individual TAE using TRANSP kick modeling (Monte Carlo evolution of the distribution function with probabilistic 'kicks' by the AEs) and the resistive MHD code with kinetic fast ions, MEGA, find no strong role of energy gradient drive due to bump-on-tail features. Instead, the observed TAE modulation with interleaved beams is likely a pitch angle dependent result combined with slowing down of the tangential beam between pulses. For the conditions investigated, bump-on-tail contributions to TAE drive were found to be 5% or less of the total drive at any given time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗