Communication through optical scattering channels - An introduction
Direct detection, heterodyne and optimum receivers for optical scattering channels in digital communication
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Direct detection, heterodyne and optimum receivers for optical scattering channels in digital communication
The results are presented for a study on the design of an infrared 10.6-micrometer quantum-noise-limited optical receiver subsystem. Performance measurements of the HgCdTe photomixer preamplifier combination were carried out for photomixer temperatures up to 152 K and a photomixer frequency response of up to 420 MHz was obtained. Results of temperature and bias cycling of HgCdTe photomixers are reported. Design considerations for an operational 10.6 micrometer heterodyne receiver are presented. These consist of design data on required laser LO illumination, heat load levels for photomixer cooler, photomixer uniformity and the effects of photomixer impedance match on receiver sensitivity. Analysis and measurements of 10.6 micrometer heterodyne detection in an extrinsic photoconductive (p-type) HgCdTe photomixer are also presented.
A computer model analysis of an infrared laser differential absorption remote sensing technique (DARS) is presented. An infrared laser source operating at two or more wavelengths and a heterodyne detection system are considered to be mounted on either an aircraft or satellite platform to monitor the differential absorption between the laser source and the earth surface. The capability of this technique for measuring gas concentrations in the lower 5 kilometers of the atmosphere is emphasized. Numerical results are presented simulating measurements of vertical burdens of CO, NO, CH4, CO2, and O3. These results indicate that measurements of expected concentrations of these gases can be made with greater than 80% accuracy using realistic laser powers and system parameters.
A spatial interferometer for 10-micron wavelength which uses two independent telescopes separated by 5.5 m, heterodyne detection of the infrared radiation, and path equalization by a variable-length RF cable, has given interference fringes from radiation of the planet Mercury. Continuous fringe observations during 4000 sec indicate remarkable stability in the optical-path difference through the atmosphere and the two telescopes, fluctuations between 20-sec averages being about 1/6 of the 10-micron wavelength.
Measurements of NH3 absorption coefficients are presented for several transitions of a C-13(O-16)2 laser for small concentrations of NH3(p less than 1 torr) for absorption lines broadened to 1 atm with N2. NH3 absorption coefficients were determined for laser transitions R(8)(920.2194 wavelengths/cm) to R(28)(933.8808 wavelengths/cm) of the 00 1 - (10 0,02 0)I band. The strongest absorption coefficient K = 36.09 + or - 1.43 per (atm-cm) was measured for the R(18) transition for the NH3 line, aQ(6,6), and is larger than has been found in any previous measurements with a CO2 laser. The dependence of K on total pressure was also obtained for select transitions, and the frequency separation between the R(18) laser transition and the neighboring NH3 line aQ(6,6) was determined to be 550 + or - 50 MHz. These results are significant for long path absorption monitoring of NH3 with CO2 lasers since the path length can be reduced by approximately 40% and for heterodyne detection of NH3 since the relative position of the laser transition to the NH3 absorption line is well within the bandpass of Hg-Cd-Te photomixers.
Principle of heterodyne detection is used to combine object beam and reconstructed virtual image beam. All light valves in page composer are opened, and virtual-image beam is allowed to interfere with light from valves.
The impact that laser techniques might have in chemical analysis is examined. Absorption, scattering, and heterodyne detection is considered. Particular emphasis is placed on the advantages of using frequency-tunable sources, and dye solution lasers are regarded as the outstanding example of this type of laser. Types of spectroscopy that can be carried out with lasers are discussed along with the ultimate sensitivity or minimum detectable concentration of molecules that can be achieved with each method. Analytical applications include laser microprobe analysis, remote sensing and instrumental methods such as laser-Raman spectroscopy, atomic absorption/fluorescence spectrometry, fluorescence assay techniques, optoacoustic spectroscopy, and polarization measurements. The application of lasers to spectroscopic methods of analysis would seem to be a rewarding field both for research in analytical chemistry and for investments in instrument manufacturing.
Absorption coefficients in the fundamental P-branch of HCl at several DF laser transitions from 2439.02/cm to 2862.87/cm have been measured experimentally. The 2-1 P(3) DF laser transition has been shown to overlap the P(6) HCl-37 absorption line within the halfwidth of an atmospherically broadened line. The absorption coefficient k was measured to be 5.64 plus or minus 0.28/(atm-cm) for a 0.27% mixture of HCl in N2 at a total pressure of 760 torr. A theoretical and experimental comparison of the pressure dependence of k showed that the 2-1 P(3) DF transition lies 1.32 plus or minus 0.15 GHz from the center of the P(6) HCl absorption line. Applications of these results to differential absorption lidar and to heterodyne detection are discussed.
A breadboard heterodyne receiver is described which was used to establish the characteristics of lead salt diode lasers pertinent to their use as local oscillators using laser devices operating in the 15-25 micrometer spectral region. Heterodyne detection efficiency is directly correlated with the transverse mode structure and emphasizes the necessity of stable lowest order mode operation for lasers when used as local oscillators. The results obtained indicate that the continued development of these lasers provide suitable local oscillators for a variety of applications.
The significance of HgCdTe photodiodes are discussed relative to their existance in heterodyne detection systems operating in the 9 to 11 micrometer CO2 laser wavelength region. Their successful fabrication as well as the physical properties of the materials are described. The implementation of controlled industrial processes are reported with emphasis on the yield of predictable and repeatable detector characteristics to the discriminating systems, demands for high cutoff frequencies, quantum efficiency, and reliability. The most salient production steps and diode characteristics are presented. Measured results from production units are also given.
The principles of transfer function analysis are applied to a passive optical heterodyne receiver to obtain the modulation transfer function (MTF). MTF calculations are performed based on an optical platform which is imaging vertically varying profiles at worst case shuttle orbit altitudes. An analysis of the derogatory effects of sampling (aliasing) and central obscurations on both resolution and heterodyne efficiency is given. It is found that the cascading property of MTF analysis must be carefully applied since the coherent transfer function of the optical receiver and that due to the local oscillator-detector combination are not separable but are related by the convolution of their products. Application of these results to the specific case of a space-lab type optical heterodyne receiver shows that resolutions of the order of 1.5-2.0 Km are possible for worst-case type orbital scenarios. Further, comparison of obscured-type receivers (e.g., Cassegrains) with unobscured receivers shows that both resolution and efficiency are severely degraded in an obscured-type receiver and consequently should not be used for a passive heterodyne detection scheme.
Linear and binary holograms for use in heterodyne detection with 10.6 micron imaging arrays are described. The devices match the amplitude and phase of the local oscillator to the received signal and thus maximize the system signal to noise ratio and resolution and minimize heat generation on the focal plane. In both the linear and binary approaches, the holographic surface-relief pattern is coded to generate a set of local oscillator beams when the relief pattern is illuminated by a single planewave. Each beam of this set has the same amplitude shape distribution as, and is collinear with, each single element wavefront illuminating array.
The relation between the signal to noise ratio (SNR) obtained in heterodyne detection of radiation scattered from acoustic modes in crystalline solids and the scattered spectral density function is studied. It is shown that in addition to the information provided by the measured frequency shifts and line widths, measurement of the SNR provides a determination of the absolute elasto-optical (Pockel's) constants. Examples are given for cubic crystals, and acceptable SNR values are obtained for scattering from thermally excited phonons at 10.6 microns, with no external perturbation of the sample necessary. The results indicate the special advantages of the method for the study of semiconductors.
The paper describes an electronic heterodyne recording which uses electrooptic modulation to introduce a sinusoidal phase shift between the object and reference wave. The resulting temporally modulated holographic interference pattern is scanned by a commercial image dissector camera, and the rejection of the self-interference terms is accomplished by heterodyne detection at the camera output. The electrical signal representing this processed hologram can then be used to modify the properties of a liquid crystal light valve or a similar device. Such display devices transform the displayed interference pattern into a phase modulated wave front rendering a three-dimensional image.
An electronic heterodyne technique is being investigated for video (i.e., television rate and format) recording of interference patterns. In the heterodyne technique electro-optic modulation is used to introduce a sinusoidal phase shift between the beams of an interferometer. For phase modulation frequencies between 0.1 and 15 MHz an image dissector camera may be used to scan the resulting temporally modulated interference pattern. Heterodyne detection of the camera output is used to selectively record the interference pattern. An advantage of such synchronous recording is that it permits recording of low-contrast fringes in high ambient light conditions. The application of this technique to the recording of holograms is discussed.
The analysis of a passive heterodyne receiver with respect to its imaging performance (transfer function) and its heterodyne efficiency shows departures from the results which are obtained in strictly coherent or incoherent imaging systems. The cascading property of modulation transfer function analysis must be carefully applied, since the coherent transfer function of the optical receiver and that due to the local oscillator-detector combination are not separable but are related by the convolution of their products. Application of these results to a spacelab-type optical heterodyne receiver shows that resolutions of the order of 1.5 to 2.0 km are possible for worst-case type orbital scenarios. In addition to an analysis of the derogatory effects of sampling (aliasing) a comparison of obscured-type receivers (e.g., Cassegrains) with unobscured receivers shows that both resolution and efficiency are severly degraded in an obscured-type receiver and, consequently, should not be used for passive heterodyne detection schemes.
CO2 lidar systems technology and signal processing requirements relevant to measurement needs and sensitivity are discussed. Doppler processing is similar to microwave radar, with signal reception controlled by a computer capable of both direct and heterodyne operations. Trace gas concentrations have been obtained with the NASA DIAL system, and trace gas transport has been determined with Doppler lidar measurements for wind velocity and turbulence. High vertical resolution measurement of trace gases, wind velocity, and turbulence are most important in the planetary boundary layer and in regions between the PBL and the lower stratosphere. Shear measurements are critical for airport operational safety. A sensitivity analysis for heterodyne detection with the DIAL system and for short pulses using a Doppler lidar system is presented. The development of transient injection locking techniques, as well as frequency stability by reducing chirp and catalytic control of closed cycle CO2 laser chemistry, is described.
Several important aspects of lidar are discussed, which pertain to a system analysis of the applicability of certain types of lidar to specific measurement objectives. The differential absorption lidar (DIAL) technique is emphasized. A brief treatment of the DIAL technique is followed by a discussion of the comparison of DIAL with other lidar measurement techniques. Sensitivity expressions are presented for DIAL with either direct or coherent (heterodyne) detection systems. A treatment of the fundamental similarities and differences in using the UV and IR spectral regions for species measurements, such as backscattering properties, spectral characteristics of the absorbing species, and factors relevant to the optimization of the DIAL measurement accuracy, is also included. Finally, results obtained from an existing ground-based DIAL system used to measure water vapor profiles are briefly discussed.