Search NASA⌕ Search

SEARCH · Search NASA

Results for “high - contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Combining hyperspectral imaging and micro-X-ray fluorescence imaging methods for ultra-high-resolution biogeochemical analysis

Current non-destructive methods for high-resolution geochemical imaging open new avenues for high-resolution paleoenvironmental research. We discuss how two of these methods, hyperspectral imaging and micro-X-ray fluorescence imaging, can be combined for organic and inorganic geochemical analyses at a micrometer scale.

Zander, Paul [Lawrence Livermore National Laborato↗

Exploration of Water Jets in Supersonic Crossflow Using X-Ray Diagnostics

Here, near-field structures of pure- and aerated-liquid jets injected into Mach 2 crossflow environments were experimentally investigated at the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory using high-speed shadowgraph imaging, high-speed x-ray imaging, and pathlength-integrated x-ray fluorescence. Liquid was flush injected into a blowdown supersonic wind tunnel. Test section top and side windows were fitted with a polycarbonate plate for high x-ray transmittance. An axisymmetric aerated-liquid injector was fitted with an exchangeable nozzle adaptor to generate a liquid jet. Water and nitrogen, the gas used for aerated-liquid jets, were doped with specially selected dopants to facilitate x-ray measurements. Liquid column structures for a pure-liquid jet, typically masked by dense droplet clouds in a supersonic crossflow environment, were visualized with the present x-ray imaging setup. Surface-wave formation, movement, and transformation on the column windward surface of the pure-liquid jet, along with column deformation and breakup processes, were qualitatively characterized. We measured time-averaged line-of-sight (LOS) liquid mass distributions within the liquid jet near fields. Cross-sectional liquid column contours of pure-liquid jets at various deformation stages were reconstructed from LOS liquid mass distributions. The pure-liquid jet deformed liquid column reached a maximum width of 1.47 times the orifice diameter before exhibiting rapid mass removal. We also observed the plume-crossing phenomenon in the aerated-liquid jet.

47 OTHER INSTRUMENTATION↗

High-field spatial imaging of charge transport in silicon at low temperature

We present direct imaging measurements of charge transport across a 1 cm × 1 cm × 4 mm-thick crystal of high purity silicon (~15 kΩ-cm) at temperatures of 5 K and 500 mK. We use these data to measure lateral diffusion of electrons and holes as a function of the electric field applied along the [111] crystal axis and to verify our low-temperature Monte Carlo software. The range of field strengths in this paper exceed those used in our previous study [R. A. Moffatt et al., Appl. Phys. Lett. 114, 032104 (2019)] by a factor of 10 and now encompass the region in which some recent silicon dark matter detectors operate [R. Agnese et al., Phys. Rev. Lett. 121, 051301 (2018)]. Finally, we also report on a phenomenon of surface charge trapping, which can reduce expected charge collection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of borated scintillator screens for high-resolution neutron imaging

The most commonly used screens for neutron imaging consist of 6 LiF + ZnS. This type of screen yields the highest light output per detected neutron. For high resolution, gadolinium oxysulfide (GOS, Gadox) screens are employed, which have a much higher detection efficiency, but a light output so much lower than LiF + ZnS that measurements are often limited by photon statistics. Historically, screens using boron as a neutron-sensitive material have not been very successful. However, a new preparation method was introduced recently that produces light output higher than Gadox with detection efficiency greater than LiF + ZnS. Measurements of these new borated screens were performed at the NeXT facility at ILL, Grenoble, in comparison to a high resolution Gadox screen.

10B↗

High-throughput chemical imaging for optimizing biofuel synthesis using synthetic biology (Final Technical Report)

Fatty acids can be produced biosynthetically in microbes and these compounds can serve as precursors to biodiesels and other high value oleochemicals. However, progress on engineering fatty acid biosynthesis, and biofuel synthesis more generally, has been hindered by current quantification methods that are either indirect or not amenable to high-throughput or single-cell resolution screening. In this project, we assembled an interdisciplinary team with complimentary expertise in synthetic biology and microscopy, metabolic engineering, and chemical imaging to address these challenges. We used chemical imaging to directly measure lipid biosynthesis in Escherichia coli engineered to produce fatty acids, obtaining detailed single-cell resolution measurements. We deployed stimulated Raman scattering (SRS) microscopy in concert with multiplexed genome engineering and gene circuit design strategies from synthetic biology to optimize production of fatty acids. These results provided novel insight into cell-to-cell heterogeneity present in biofuel production strains. In addition, we introduced new chemical imaging methods which are label-free and do not require fluorescent reporters. These efforts were complemented by other studied developing foundational tools for regulation and control, which offer excellent potential for advancing researchers’ ability to rapidly design, build, and test strains for enhanced biofuel synthesis.

09 BIOMASS FUELS↗

Transmission of Images on High-Temperature Nuclear-Grade Metallic Pipe with Ultrasonic Elastic Waves

Transmission of information using elastic ultrasonic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall, with minimal modification of the existing hardware. Because bit rates on the order of kilobits per second are achievable, relatively large volumes of data, such as images, can be transmitted. A viable candidate for an ultrasonic communication channel is a stainless steel pipe of the chemical volume control system (CVCS) that penetrates through the reactor containment building wall through a sealed tunnel. To study ultrasonic communication under simulated nuclear facility conditions of high temperature, a test article was developed by installing heating tapes, temperature controllers, and thermal insulation on a laboratory CVCS-like stainless steel pipe. High temperature and radiation-resilient lithium niobate ultrasonic transducers were utilized for information transmission on the heated pipe. The amplitude shift keying (ASK) digital communication protocol was developed and implemented in a GNU Radio software-defined radio environment. A root-raised-cosine filter was introduced to suppress ultrasonic transducer ringing and thus reduce inter-symbol interference. This resulted in the enhancement of the data transmission bit rate compared to information encoding with square pulses. Demonstrations of communication at high temperature included transmission of a 90-KB image at the bit rate of 10 Kbps with a bit error rate of 10 -3 across a 6-ft-long straight pipe heated up to 230 degrees C. Additional preliminary studies were conducted to evaluate ultrasonic communication system resilience to environmental degradation and damage.

42 ENGINEERING↗

ExtremeMETA: High-speed Lightweight Image Segmentation Model by Remodeling Multi-channel Metamaterial Imagers

Deep neural networks (DNNs) have heavily relied on traditional computational units, such as CPUs and GPUs. However, this conventional approach brings significant computational burden, latency issues, and high power consumption, limiting their effectiveness. This has sparked the need for lightweight networks such as ExtremeC3Net. Meanwhile, there have been notable advancements in optical computational units, particularly with metamaterials, offering the exciting prospect of energy-efficient neural networks operating at the speed of light. Yet, the digital design of metamaterial neural networks (MNNs) faces precision, noise, and bandwidth challenges, limiting their application to intuitive tasks and low-resolution images. In this study, we proposed a large kernel lightweight segmentation model, ExtremeMETA. Based on ExtremeC3Net, our proposed model, ExtremeMETA maximized the ability of the first convolution layer by exploring a larger convolution kernel and multiple processing paths. With the large kernel convolution model, we extended the optic neural network application boundary to the segmentation task. To further lighten the computation burden of the digital processing part, a set of model compression methods was applied to improve model efficiency in the inference stage. The experimental results on three publicly available datasets demonstrated that the optimized efficient design improved segmentation performance from 92.45 to 95.97 on mIoU while reducing computational FLOPs from 461.07 MMacs to 166.03 MMacs. The large kernel lightweight model ExtremeMETA showcased the hybrid design’s ability on complex tasks.

large convolution kernel↗

Use of computer vision for analysis of image datasets from high temperature plasma experiments

Great strides have been made in improving the quality of x-ray radiographs in high energy density plasma experiments, enabled in part by innovations in engineering and manufacturing of integrated circuits and materials. As a consequence, the radiographs of today are filled with a great deal of detail, but few of these features are extracted in a systematic way. Analysis techniques familiar to plasma physicists tend toward brittle 1D lineout or Fourier transform type analyses. The techniques applied to process our data have not kept pace with improvements in the quality of our data. Fortunately, the field of computer vision has a wealth of tools to offer, which have been widely used in industrial imaging and, more recently, adopted in biological imaging. We demonstrate the application of computer vision techniques to the analysis of x-ray radiographs from high energy density plasma experiments, as well as give a brief tutorial on the computer vision techniques themselves. These tools robustly extract 2D contours of shocks, boundaries of inhomogeneities, and secondary flows, thereby allowing for increased automation of analysis, as well as direct and quantitative comparisons with simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Super-resolution image display using diffractive decoders

High-resolution image projection over a large field of view (FOV) is hindered by the restricted space-bandwidth product (SBP) of wavefront modulators. We report a deep learning–enabled diffractive display based on a jointly trained pair of an electronic encoder and a diffractive decoder to synthesize/project super-resolved images using low-resolution wavefront modulators. The digital encoder rapidly preprocesses the high-resolution images so that their spatial information is encoded into low-resolution patterns, projected via a low SBP wavefront modulator. The diffractive decoder processes these low-resolution patterns using transmissive layers structured using deep learning to all-optically synthesize/project super-resolved images at its output FOV. This diffractive image display can achieve a super-resolution factor of ~4, increasing the SBP by ~16-fold. We experimentally validate its success using 3D-printed diffractive decoders that operate at the terahertz spectrum. This diffractive image decoder can be scaled to operate at visible wavelengths and used to design large SBP displays that are compact, low power, and computationally efficient.

36 MATERIALS SCIENCE↗

Deep-learning-guided high-resolution subsurface reflectivity imaging with application to ground-penetrating radar data

Subsurface reflectivity imaging is one of the most important geophysical characterization methods for revealing subsurface structures. In many cases, accurate subsurface reflectivity imaging is challenging because of, for example, random or coherent noise in the data and sparse source-receiver observation geometry. Here, we develop a deep-learning-guided iterative imaging method to improve subsurface structure imaging. Specifically, we train a supervised neural network to infer a noise-free, high-resolution image from a noisy, low-resolution image and use this estimated image as guidance to regularize least-squares imaging. We develop a systematic method to generate high-quality synthetic training data (data-label pairs) to train the guidance neural network. The trained neural network can provide high-fidelity predictions even for field-data images that are not in the training data. We validate our new imaging method using one synthetic and two field ground-penetrating radar data examples, and find that our method can produce clean, high-resolution subsurface reflectivity images where existing single-pass and least-squares imaging methods fail due to noise and insufficient data coverage.

58 GEOSCIENCES↗

Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. Herein, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

47 OTHER INSTRUMENTATION↗

High-Resolution Momentum Imaging—From Stern’s Molecular Beam Method to the COLTRIMS Reaction Microscope [Book Chapter]

Multi-particle momentum imaging experiments are now capable of providing detailed information on the properties and the dynamics of quantum systems in Atomic, Molecular and Photon (AMO) physics. Historically, Otto Stern can be considered the pioneer of high-resolution momentum measurements of particles moving in a vacuum and he was the first to obtain sub-atomic unit (a.u.) momentum resolution (Schmidt-Böcking et al. in The precision limits in a single-event quantum measurement of electron momentum and position, these proceedings). A major contribution to modern experimental atomic and molecular physics was his so-called molecular beam method, which Stern developed and employed in his experiments. With this method he discovered several fundamental properties of atoms, molecules and nuclei. As corresponding particle detection techniques were lacking during his time, he was only able to observe the averaged footprints of large particle ensembles. Today it is routinely possible to measure the momenta of single particles, because of the tremendous progress in single particle detection and data acquisition electronics. A “state-of-the-art” COLTRIMS reaction microscope can measure, for example, the momenta of several particles ejected in the same quantum process in coincidence with sub-a.u. momentum resolution. Such setups can be used to visualize the dynamics of quantum reactions and image the entangled motion of electrons inside atoms and molecules. This review will briefly summarize Stern’s work and then present in longer detail the historic steps of the development of the COLTRIMS reaction microscope. Furthermore, some benchmark results are shown which initially paved the way for a broad acceptance of the COLTRIMS approach. Finally, a small selection of milestone work is presented which has been performed during the last two decades.

Jahnke, T.↗

Microfabrication of a Chamber for High-Resolution, In Situ Imaging of the Whole Root for Plant–Microbe Interactions

Fabricated ecosystems (EcoFABs) offer an innovative approach to in situ examination of microbial establishment patterns around plant roots using nondestructive, high-resolution microscopy. Previously high-resolution imaging was challenging because the roots were not constrained to a fixed distance from the objective. Here, we describe a new ‘Imaging EcoFAB’ and the use of this device to image the entire root system of growing Brachypodium distachyon at high resolutions (20×, 40×) over a 3-week period. The device is capable of investigating root–microbe interactions of multimember communities. We examined nine strains of Pseudomonas simiae with different fluorescent constructs to B. distachyon and individual cells on root hairs were visible. Succession in the rhizosphere using two different strains of P. simiae was examined, where the second addition was shown to be able to establish in the root tissue. The device was suitable for imaging with different solid media at high magnification, allowing for the imaging of fungal establishment in the rhizosphere. Overall, the Imaging EcoFAB could improve our ability to investigate the spatiotemporal dynamics of the rhizosphere, including studies of fluorescently-tagged, multimember, synthetic communities.

59 BASIC BIOLOGICAL SCIENCES↗

Large field-of-view event-mode camera for high-precision epithermal neutron resonance imaging

A large-area event-mode camera system coupled with a 6 LiF-ZnS:Ag scintillator is applied for neutron resonance imaging (NRI) on the energy-resolved neutron imaging (ERNI) flight path, also known as Flight Path 5 (FP5), at the Los Alamos Neutron Science Center (LANSCE). This novel neutron imaging system, featuring a 120 x 120 mm 2 field of view, efficiently captures resonance information across the entire image in a single acquisition, significantly reducing beam time requirements compared to conventional energy-resolved neutron imaging systems. High-quality neutron radiographs with enhanced spatial resolution are achieved through the reconstruction of neutron events based on observations of individual photons emitted from the scintillator. The system demonstrates reduced background through neutron/gamma discrimination capabilities while maintaining sharpness across a large fields of view. In the measurements presented here, a spatial resolution of approximately 340 μm was achieved using center-of-gravity photon cluster centroiding. We demonstrate the system’s capability for quantitatively determining isotopic distributions in various thin samples, as well as automatically reconstructing complex scenes with overlapping resonances from diverse samples. These results are obtained using standard data analysis tools, despite the relatively slow 6 LiF-ZnS:Ag scintillator, which may not be optimal for absorption resonance detection. The capabilities demonstrated here offer a valuable, versatile, and cost-effective solution for high spatial and temporal resolution, large field-of-view energy-resolved neutron imaging, with potential applications across various scientific and industrial domains.

36 MATERIALS SCIENCE↗

Capturing high‐resolution digital images for use in forensic document examination

Abstract In the past, pattern disciplines within forensic science have periodically faced criticism due to their subjective and qualitative nature and the perceived absence of research evaluating and supporting the foundations of their practices. Recently, however, forensic scientists and researchers in the field of pattern evidence analysis have developed and published approaches that are more quantitative, objective, and data driven. This effort includes automation, algorithms, and measurement sciences, with the end goal of enabling conclusions to be informed by quantitative models. Before employing these tools, forensic evidence must be digitized in a way that adequately balances high‐quality detail and content capture with minimal background noise imparted by the selected technique. While the current work describes the process of optimizing a method to digitize physical documentary evidence for use in semi‐automated trash mark examinations, it could be applied to assist other disciplines where the digitization of physical items of evidence is prevalent. For trash mark examinations specifically, it was found that high‐resolution photography provided optimal digital versions of evidentiary items when compared to high‐resolution scanning.

Riley, Paige↗

Autonomous Molecular Structure Imaging with High-Resolution Atomic Force Microscopy for Molecular Mixture Discovery

Due to its single-molecule sensitivity, high-resolution atomic force microscopy (HR-AFM) has proved to be a valuable and uniquely advantageous tool to study complex molecular mixtures, which hold promise for developing clean energy and achieving environmental sustainability. However, significant challenges remain to achieve the full potential of the sophisticated and time-consuming experiments. Automation combined with machine learning (ML) and artificial intelligence (AI) is key to overcoming these challenges. Here we present Auto-HR-AFM, an AI tool to automatically collect HR-AFM images of petroleum-based mixtures. In this study, we trained an instance segmentation model to teach Auto-HR-AFM how to recognize features in HR-AFM images. Auto-HR-AFM then uses that information to optimize the imaging by adjusting the probe-molecule distance for each molecule in the run. Auto-HR-AFM is the initial tool that will lead to fully automated scanning probe microscopy (SPM) experiments, from start to finish. This automation will allow SPM to become a mainstream characterization technique for complex mixtures, an otherwise unattainable target.

36 MATERIALS SCIENCE↗