Search NASA⌕ Search

SEARCH · Search NASA

Results for “high efficiency wall”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Vitrification of High-Level Waste: how to Select the Best Suited Technology - 18117

Since more than 30 years now, a number of countries have selected and operated vitrification as the best industrial practice for safely and durably immobilizing the most active liquid waste. This now significant worldwide experience covers a wide range of waste compositions, from concentrated alkaline defense waste sludges with a variety of salts and chemicals (Na, Fe, Al, Cr, sulphate,... ) to relatively clear acidic HLLW from commercial, low salt, PUREX-type processes, waste that include dissolved cladding material (Al, Mg, stainless steel), waste that include high levels of noble metals and fines... The activity levels vary from 40- year old defense waste to relatively young waste from high burn-up commercial fuel. The current throughputs vary from about 5 kg/h of glass to about 90 kg/h of glass per melter. Even higher throughputs are currently being considered for Hanford facility for instance. In order to cope with the range of waste compositions, glass compositions have also evolved from low melting temperature borosilicate or phosphate glass to glass or glass ceramics with higher melting temperatures. More complex matrices are currently under study in a number of countries, to immobilize more complex waste and / or increase waste loadings. Each challenge is unique and, for each challenge, it is necessary to select the best combination of waste form and technology. For instance for very active solutions with high levels of noble metal particles that could settle, increase apparent glass viscosity, and impact electrical conductivity, one would select borosilicate glass in the mechanically-stirred hot wall induction melter with bottom pouring that has proven its efficiency in industrial conditions at La Hague. For high glass throughputs with low solids in a borosilicate melt (typically Defense waste), ceramic melters have proven their reliability and efficiency. For matrices that need higher temperatures, or with very high corrosiveness, Cold-Crucible Induction Melters are now considered, with one first industrial implementation at La Hague to produce borosilicate glass and a glass-ceramic. All these technologies have been improved over the years to increase throughput, waste loading, melting temperature, reliability... Other types of waste are now being studied worldwide, and for each, it is necessary to carefully select the adapted waste form and technology. The technologies studied will range from traditional technologies (such as hot-wall induction melter technology and liquid-fed ceramic melter technologies) to the more recent advanced technologies (such as Cold Crucible Induction Melter or Advanced Ceramic melters). In addition, the field of vitrification is extending to other types of waste; the current advances in this field will also be described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of multi-active region p-down green LEDs with high quantum efficiency

Abstract Longer wavelength emitters such as green LEDs display a pronounced efficiency drop at higher current densities, resulting in relatively low wall-plug efficiency (WPE). Multi-active region approach can improve the WPE significantly and tackle the “green gap” challenge. This work reports multi-active region p-down LEDs with high external efficiency operating entirely in the green wavelength. Devices were developed using p-down topology, where the PN junction is oriented such that electric fields from depletion and built-in polarization dipoles are aligned. Ga-polar multi-active region green LEDs with excellent voltage and external quantum efficiency scaling, and significantly higher WPE is demonstrated in this work.

Physics↗

Optimization of thermal barrier coating performance and durability over a drive cycle

A methodology to thermo-mechanically optimize a piston thermal barrier coating over a full drive cycle was established. The optimization objective was to minimize the heat transfer to the engine wall while maintaining structural integrity of the coating. Over 800 candidate materials were investigated and the optimization required more than one million non-road transient drive cycle calculations; real materials were investigated to ensure a realizable result and the existence of thermal and mechanical properties. High computational efficiency was achieved using a recently developed analytical heat transfer technique for multilayer engine walls. An uncoupled approach was utilized for the optimization, wherein the gas temperature and heat transfer coefficient profiles from a fully coupled and calibrated baseline model over the 20-min drive cycle were employed. The coating/piston interface temperature was constrained to be below the maximum piston service temperature limit. The durability was assessed using a recently developed analytical coating delamination framework for engine in-cylinder coatings based on the energy release rate when a crack forms. Results are presented for a mechanically unconstrained optimization and for cases constrained to three fixed levels of drive-cycle maximum energy release rate, and also constrained by the individual material’s toughness. The best-performing coating materials identified were verified using the fully coupled system-level model, which compared well to the uncoupled predictions. A study on the effect of adding a sealing layer to some high-performing, but porous, coatings showed a reduction in fuel consumption benefit and an increased exhaust temperature over the cycle, but the system still outperformed the uncoated case. The results of the study elucidate the importance of including engine performance and mechanical failure considerations in thermal barrier coating design.

Engineering↗

Immunological Approaches to Biomass Characterization and Utilization

Plant biomass is the major renewable feedstock resource for sustainable generation of alternative transportation fuels to replace fossil carbon-derived fuels. Lignocellulosic cell walls are the principal component of plant biomass. Hence, a detailed understanding of plant cell wall structure and biosynthesis is an important aspect of bioenergy research. Cell walls are dynamic in their composition and structure, varying considerably among different organs, cells, and developmental stages of plants. Hence, tools are needed that are highly efficient and broadly applicable at various levels of plant biomass-based bioenergy research. The use of plant cell wall glycan-directed probes has seen increasing use over the past decade as an excellent approach for the detailed characterization of cell walls. Large collections of such probes directed against most major cell wall glycans are currently available worldwide. The largest and most diverse set of such probes consists of cell wall glycan-directed monoclonal antibodies (McAbs). These McAbs can be used as immunological probes to comprehensively monitor the overall presence, extractability, and distribution patterns among cell types of most major cell wall glycan epitopes using two mutually complementary immunological approaches, glycome profiling (an in vitro platform) and immunolocalization (an in situ platform). Significant progress has been made recently in the overall understanding of plant biomass structure, composition, and modifications with the application of these immunological approaches. This review focuses on such advances made in plant biomass analyses across diverse areas of bioenergy research.

59 BASIC BIOLOGICAL SCIENCES↗

An efficient modeling method for thermal stratification simulation in a BWR suppression pool

The suppression pool in a BWR plant not only is the major heat sink within the containment system, but also provides major emergency cooling water for the reactor core. In several accident scenarios, such as LOCA and extended station blackout, thermal stratification tends to form in the pool after the initial rapid venting stage. Accurately predicting the pool stratification phenomenon is important because it affects the peak containment pressure; and the pool temperature distribution also affects the NPSHa (Available Net Positive Suction Head) and therefore the performance of the pump which draws cooling water back to the core. Current safety analysis codes use 0-D lumped parameter methods to calculate the energy and mass balance in the pool and therefore have large uncertainty in prediction of scenarios in which stratification and mixing are important. While 3-D CFD methods can be used to analyze realistic 3D configurations, these methods normally require very fine grid resolution to resolve thin substructures such as jets and wall boundaries, therefore long simulation time. For mixing in stably stratified large enclosures, the BMIX++ code has been developed to implement a highly efficient analysis method for stratification where the ambient fluid volume is represented by 1-D transient partial differential equations and substructures such as free or wall jets are modeled with 1-D integral models. This allows very large reductions in computational effort compared to 3-D CFD modeling. The POOLEX experiments at Finland, which was designed to study phenomena relevant to Nordic design BWR suppression pool including thermal stratification and mixing, are used for validation. GOTHIC lumped parameter models are used to obtain boundary conditions for BMIX++ code and CFD simulations. Comparison between the BMIX++, GOTHIC, and CFD calculations against the POOLEX experimental data is discussed in detail.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study on optimal inertial-confinement-fusion hohlraum wall radial density and wall loss

Reducing hohlraum wall loss is one of the most important ways to improve hohlraum coupling efficiency in laser indirect drive inertial-confinement fusion. It is appeared that a high Z metallic foam as hohlraum wall material will reduce wall loss. By adjusting initial hohlraum wall density distribution along radial axes to {rho}{sub 0}(r)=kr, the numerical simulation results show that it can indeed bring best savings of {approx}40% general wall loss. We conclude that absorbed energy mainly decreases by restraining rarefactions, and a proper slope k can optimize internal energy loss of low density and increased kinetic loss by subsonic. Also saved energy ratio reduces with source temperature decreasing. This approach would cut the reactor driver that needs quite substantially if experiments demonstrate it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-exciton emission from solitary dopant states of carbon nanotubes

By separating the photons from slow and fast decays of single and multi-exciton states in a time gated 2 nd order photon correlation experiment, we show that solitary oxygen dopant states of single-walled carbon nanotubes (SWCNTs) allow emission of photon pairs with efficiencies as high as 44% of single exciton emission. Here, our pump dependent time resolved photoluminescence (PL) studies further reveal diffusion-limited exciton–exciton annihilation as the key process that limits the emission of multi-excitons at high pump fluences. We further postulate that creation of additional permanent exciton quenching sites occurring under intense laser irradiation leads to permanent PL quenching. With this work, we bring out multi-excitonic processes of solitary dopant states as a new area to be explored for potential applications in lasing and entangled photon generation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of Spanwise Boundary Conditions on Slat Noise Simulations

The slat noise from the 30P/30N high-lift system is being investigated through computational fluid dynamics simulations with the OVERFLOW code in conjunction with a Ffowcs Williams-Hawkings acoustics solver. In the present study, two different spanwise grids are being used to investigate the effect of the spanwise extent and periodicity on the near-field unsteady structures and radiated noise. The baseline grid with periodic boundary conditions has a short span equal to 1/9th of the stowed chord, whereas the other, longer span grid adds stretched grids on both sides of the core, baseline grid to allow inviscid surface boundary conditions at both ends. The results indicate that the near-field mean statistics obtained using the two grids are similar to each other, as are the directivity and spectral shapes of the radiated noise. However, periodicity forces all acoustic waves with less than one wavelength across the span to be two-dimensional, without any variation in the span. The spanwise coherence of the acoustic waves is what is needed to make estimates of the noise that would be radiated from realistic span lengths. Simulations with periodic conditions need spans of at least six slat chords to allow spanwise variation in the low-frequencies associated with the peak of broadband slat noise. Even then, the full influence of the periodicity is unclear, so employing grids with a fine, central region and highly stretched meshes that go to slip walls may be a more efficient means of capturing the spanwise decorrelation of low-frequency acoustic phenomena.

Lockard, David P.↗

CHANDRA IMAGING AND SPECTROSCOPY OF THE EASTERN XA REGION OF THE CYGNUS LOOP SUPERNOVA REMNANT

The XA region of the Cygnus Loop is a bright knot of X-ray emission on the eastern edge of the supernova remnant. The emission results from the interaction of the supernova blast wave with density enhancements at the edge of a precursor formed cavity. However, this interaction is complex given the irregular morphology of the cavity wall. To study the nature and origin of the X-ray emission, we use high spatial resolution images from Chandra. We extract spectra from these images to analyze the physical conditions of the plasma. Our goal is to probe the density of various regions to form a picture of the cavity wall and characterize the interaction between this supernova and the local interstellar medium. We find that a series of regions along the edge of the X-ray emission appears to trace out the location of the cavity wall. The best-fit plasma models result in two temperature component equilibrium models for each region. The low-temperature components have densities that are an order of magnitude higher than the high-temperature components. The high-density plasma may exist in the cavity wall where it equilibrates rapidly and cools efficiently. The low-density plasma is interior to the enhancement and heated further by a reverse shock from the wall. Calculations of shock velocities and timescales since shock heating are consistent with this interpretation. Furthermore, we find a bright knot of emission indicative of a discrete interaction of the blast wave with a high-density cloud in the cavity wall with a size scale {approx}0.1 pc. Aside from this, other extractions made interior to the X-ray edge are confused by line-of-sight projection of various components. Some of these regions show evidence of detecting the cavity wall but their location makes the interpretation difficult. In general, the softer plasmas are well fit at temperatures (kT){approx} 0.11 keV, with harder plasmas at temperatures of (kT){approx} 0.27 keV. All regions displayed consistent metal depletions most notably in N, O, and Ne at an average of 0.54, 0.55, and 0.36 times solar, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of an Accurate DNS Particulate Flow Method to Supply and Validate Boundary Conditions for the MFIX Code (Final Report)

The simulation of particulate flows for industrial applications often requires the use of two-fluid models, where the solid particles are considered as a separate continuous phase. One of the underlining uncertainties in the use of the two-fluid models in multiphase computations comes from the boundary condition of the solid phase. Typically, the gas or liquid fluid boundary condition at a solid wall is the so called no-slip condition, which has been widely accepted to be valid for single-phase fluid dynamics provided that the Knudsen number is low. However, the boundary condition for the solid phase is not well understood. The no-slip condition at a solid boundary is not a valid assumption for the solid phase. Instead, several researchers advocate a slip condition as a more appropriate boundary condition. However, the question on the selection of an exact slip length or a slip velocity coefficient is still unanswered. Experimental or numerical simulation data are needed in order to determinate the slip boundary condition that is applicable to a two-fluid model. The goal of this project is to improve the performance and accuracy of the boundary conditions used in two-fluid models such as the MFIX code, which is frequently used in multiphase flow simulations. The specific objectives of the project are to use first principles embedded in a validated Direct Numerical Simulation particulate flow numerical program, which uses the Immersed Boundary method (DNS-IB) and the Direct Forcing scheme in order to establish, modify and validate needed energy and momentum boundary conditions for the MFIX code. To achieve these objectives, we have developed a highly efficient DNS code and conducted numerical simulations to investigate the particle-wall and particle-particle interactions in particulate flows. Most of our research findings have been reported in major conferences and archived journals, which are listed in Section 7 of this report. In this report, we will present a brief description of these results.

42 ENGINEERING↗

Film cooling on a convex wall: Heat transfer and hydrodynamic measurements for full and partial coverage

Turbine-blade cooling is an important issue for high-efficiency turbine engines, and discrete-hole injection is widely used as a cooling method. In the present study, detailed measurements were made of the heat transfer and hydrodynamics of a film-cooled flow on a convex wall, both for full and partial coverage. Two important parameters were altered: the blowing ratio, m, and the number of rows of injection holes. Three values of m were tested: m = 0.2, 0.4, and 0.6. In the blown region, m = 0.4 results in the lowest Stanton numbers of the three blowing ratios tested. This indicates that the value of m = 0.4 is near optimum on the convex wall from the point of view of cooling effect by injection. In the recovery region, Stanton numbers gradually approach the no injection values. Although the heat-transfer behavior during recovery from injection looks relatively complicated, the behavior of Stanton number can be explained in terms of two mechanisms: recovery from the thermal effect of injection and recovery from the turbulence augmentation. This interpretation of the data is supported by the hydrodynamic and temperture-profile measurements. For partial blowing cases, the data follow the full-coverage values inside the blown region. In the unblown region, both in the curved and in the flat plate, the effect of the number of blown rows is clearly seen. Hydrodynamic boundary-layer profiles were measured with the aid of a triple hot-water probe. Three mean-velocity components and six turbulence quantities were simultaneously measured, and inside the blown region strong three-dimensionality was observed.

Furuhama, K.↗

An assessment of CFD-based wall heat transfer models in piston engines

The lack of accurate submodels for in-cylinder heat transfer has been identified as a key shortcoming in developing truly predictive, physics-based computational fluid dynamics (CFD) models that can be used to develop combustion systems for advanced high-efficiency, low-emissions engines. Only recently have experimental methods become available that enable accurate near-wall measurements to enhance simulation capability via advancing models. Initial results show crank-angle dependent discrepancies with respect to previously used boundary-layer models of up to 100%. However, available experimental data is quite sparse (only few data points on engine walls) and limited (available measurements are those of heat flux only). Predictive submodels are needed for medium-resolution ("engineering") LES and for unsteady Reynolds-averaged simulations (URANS). Recently, some research groups have performed DNS studies on engine-relevant conditions using simple geometries. These provide very useful data for benchmarking wall heat transfer models under such conditions. Further, a number of new and more sophisticated models have also become available in the literature which account for these engine-like conditions. Some of these have been incorporated while others of a more complex nature, which include solving additional partial differential equations (PDEs) within the thin boundary layer near the wall, are underway. These models will then be tested against the available DNS/experimental data in both SI (spark-ignition) and CI (compression-ignition) engines.

33 ADVANCED PROPULSION SYSTEMS↗

High resolution PET breast imager with improved detection efficiency

A highly efficient PET breast imager for detecting lesions in the entire breast including those located close to the patient's chest wall. The breast imager includes a ring of imaging modules surrounding the imaged breast. Each imaging module includes a slant imaging light guide inserted between a gamma radiation sensor and a photodetector. The slant light guide permits the gamma radiation sensors to be placed in close proximity to the skin of the chest wall thereby extending the sensitive region of the imager to the base of the breast. Several types of photodetectors are proposed for use in the detector modules, with compact silicon photomultipliers as the preferred choice, due to its high compactness. The geometry of the detector heads and the arrangement of the detector ring significantly reduce dead regions thereby improving detection efficiency for lesions located close to the chest wall.

60 APPLIED LIFE SCIENCES↗

The feasibility study of hot cell decontamination by the PFC spray method

The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to be reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research Institute (KAERI) is developing dry decontamination technologies applicable to a decontamination of a highly radioactive area loosely contaminated with radioactive particles. This contamination has occurred as a result of an examination of a post-irradiated material or the development of the DUPIC process. The dry decontamination technologies developed are the carbon dioxide pellet spray method and the PFC spray method. As a part of the project, PFC ultrasonic decontamination technology was developed in 2004. The PFC spray decontamination method which is based on the test results of the PFC ultrasonic method has been under development since 2005. The developed PFC spray decontamination equipment consists of four modules (spray, collection, filtration and distillation). Vacuum cup of the collection module gathers the contaminated PFC solution, then the solution is moved to the filtration module and it is recycled. After a multiple recycling of the spent PFC solution, it is purified in the distillation module. A performance test on each module was executed and the results have been reported. A combined test of the four modules, however, has not been performed as yet. The main objective of the present study is to demonstrate the feasibility of the full PFC spray decontamination process. Decontamination of the inside of the IMEF hot cell by the PFC spray method was also performed. PFC spray decontamination process was demonstrated by using a surrogate wall contaminated with Eu{sub 2}O{sub 3} powder. The spray pressure was 41 kgf/cm{sup 2}, the orifice diameter was 0.2 mm and the spray velocity was 0.2 L/min. And, the decontaminated area was 100 cm{sup 2}. From previous test results, we found that the decontamination factor of the PFC spray method was in the range from 9.6 to 62.4. When the decontamination efficiency of Co-60 was high, then the decontamination efficiency of Cs-137 was also high. As the surface roughness of the specimen increased, the PFC spray decontamination efficiency decreased. Inferring from the previous results, the surface of the surrogate wall was cleaned by the PFC spray method. The vacuum cup of the collection module operated well and gathered more than 99 % of the PFC solution. Also, filtration and distillation modules operated well. All the filtered PFC solution flowed to the storage chamber where some of the PFC solution was distilled. The coolant of the distillation module was a dry ice. And, the recycled solution was transferred to the spray module by a high pressure pump. To evaluate the PFC spray decontamination efficiency, a smear device was fabricated and operated by a manipulator. Before and after decontamination, a smear test was performed. The tested area was 100 cm{sup 2} and the radioactivity was estimated indirectly by measuring the radioactivity of the filter paper. The average decontamination factor was in the range between 10 and 15. One application time was 2 minutes. The sprayed PFC solution was collected by the vacuum cup and it was stored in the collection equipment. After the termination of the decontamination test, the flexible hose was cut near a toboggan. The collection equipment that contained the spent PFC solution, vacuum cup, spray nozzle and the flexible hose was stored in a radioactive waste storage tank. A feasibility study for the PFC spray decontamination method for an application to a hot cell surface was performed. The decontamination equipment that consisted of four modules operated well in the hot cell. The collection module gathered the sprayed PFC solution. The solution was purified in the filtration or distillation modules. The main characteristic of the distillation module is the use of dry ice as a coolant. The decontamination factor of IMEF hot cell was in the range from 10 to 15. It was difficult to measure the radioactivity accurately at a given time. We, however, concluded that the PFC spray decontamination method is a promising technology. It generated a small amount of secondary waste and used a non-toxic and non-conducting material. Decontamination work was performed with a little loss of the main decontamination agent. Based on the test results, we are developing an improved PFC spray decontamination process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

Understanding Charge Transfer in Carbon Nanotube–Fullerene Bulk Heterojunctions

Semiconducting single-walled carbon nanotube/fullerene bulk heterojunctions exhibit unique optoelectronic properties highly suitable for flexible, efficient, and robust photovoltaics and photodetectors. We investigate charge-transfer dynamics in inverted devices featuring a polyethylenimine-coated ZnO nanowire array infiltrated with these blends and find that trap-assisted recombination dominates transport within the blend and at the active layer/nanowire interface. We find that electrode modifiers suppress this recombination, leading to high performance.

36 MATERIALS SCIENCE↗

Quantitative analysis of leakage current in III-nitride micro-light-emitting diodes

In this study, the electrical characteristics under forward- and reverse-bias conditions of III-nitride blue and green micro-light-emitting diodes (μLEDs) are analyzed. A fitting model is proposed to determine the contributions of reverse leakage current and the effectiveness of sidewall treatments. Moreover, the forward-bias currents of the μLEDs are examined using the extracted ideality factor to examine the impacts of sidewall defects. The results show that sidewall treatments are highly effective for suppression of leakage currents. From the efficiency perspective, higher wall-plug efficiency (WPE) than external quantum efficiency (EQE) is observed when the operating voltage is lower than the photon voltage in both blue and green 20 × 20 μm 2 devices. This enhancement of the WPE over the EQE is due to the suppression of Shockley–Read–Hall (SRH) nonradiative recombination. These observations indicate that μLEDs with sidewall treatments not only improve optical performance but also further enhance the electrical performance of devices by suppressing the leakage current paths due to SRH nonradiative recombination processes.

42 ENGINEERING↗