A Compact, Highly Scalable, Low-Power, and Multi-Channel Charge Digitizer for Beam Profile Monitoring
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Roadways with dynamic wireless charging systems (DWCS) enable charge-sustaining in-motion EV charging, which can reduce charging idle time while increasing range capabilities. Spatially distributed transmitter coils are controlled in response to traffic load that varies significantly minute to minute with high power levels, very short charging time, and low system utilization like wind turbine power. Traffic load estimation and localized analysis may guide effective sizing and topology adoption for feasible and scalable DWCS deployment. DWCS traffic load approximation is reviewed with measured Automated Traffic Recorder (ATR) data and statistical distributions being used to create a synthetic load analyzed using proposed metrics quantifying system utilization over time. Lumped coil section segmentation is compared between second-based distance and spatial density analysis methods, offering 17-27% greater system utilization. A peak load shifting method is proposed for traffic redirection across two tracks with optional BESS integration increasing system utilization by 50-60% depending on time-based and power reserve-based sizing and control.
This paper proposes a shared magnetic arrangement for an electric-vehicle charger that supports both conductive and inductive charging while preserving independent power control at the two ports. In the proposed implementation, the high-frequency transformer used for the conductive path and the resonant inductor required by the inductive path are realized in an integrated form. By combining the magnetic structure and primary-side converter hardware, the charger can deliver improved hardware utilization and higher power density without a corresponding increase in cost or implementation complexity. The paper describes the magnetic realization and presents finite-element and circuit-level simulation results to confirm minimal interaction between the two charging paths. The study demonstrates that the proposed charger is a viable option for flexible, high-power EV charging systems.
As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.
Dielectric electrostatic capacitors, because of their ultrafast charge-discharge, are desirable for high-power energy storage applications. Along with ultrafast operation, on-chip integration can enable miniaturized energy storage devices for emerging autonomous microelectronics and microsystems. Moreover, state-of-the-art miniaturized electrochemical energy storage systems-microsupercapacitors and microbatteries-currently face safety, packaging, materials and microfabrication challenges preventing on-chip technological readiness, leaving an opportunity for electrostatic microcapacitors. Here, in this study, we report record-high electrostatic energy storage density (ESD) and power density, to our knowledge, in HfO 2 -ZrO 2 -based thin film microcapacitors integrated into silicon, through a three-pronged approach. First, to increase intrinsic energy storage, atomic-layer-deposited antiferroelectric HfO 2 -ZrO 2 films are engineered near a field-driven ferroelectric phase transition to exhibit amplified charge storage by the negative capacitance effect, which enhances volumetric ESD beyond the best-known back-end-of-the-line-compatible dielectrics (115 J cm -3 ). Second, to increase total energy storage, antiferroelectric superlattice engineering scales the energy storage performance beyond the conventional thickness limitations of HfO 2 -ZrO 2 -based (anti)ferroelectricity (100-nm regime). Third, to increase the storage per footprint, the superlattices are conformally integrated into three-dimensional capacitors, which boosts the areal ESD nine times and the areal power density 170 times that of the best-known electrostatic capacitors: 80 mJ cm -2 and 300 kW cm -2 , respectively. This simultaneous demonstration of ultrahigh energy density and power density overcomes the traditional capacity-speed trade-off across the electrostatic-electrochemical energy storage hierarchy. Furthermore, the integration of ultrahigh-density and ultrafast-charging thin films within a back-end-of-the-line-compatible process enables monolithic integration of on-chip microcapacitors, which can unlock substantial energy storage and power delivery performance for electronic microsystems.
Abstract We describe an interplay between two injection mechanism of background electrons into an evolving plasma bubble behind an intense laser pulse: one due to the overall bubble expansion, and another due to its periodic undulation. The two mechanisms occur simultaneously when an intense laser pulse propagating inside a plasma forms a shock-like steepened front. Periodic undulations of the plasma bubble along the laser propagation path can either inhibit or conspire with electron injection due to bubble expansion. We show that carrier-envelope-phase (CEP) controlled plasma bubble undulation induced by the self-steepening laser pulse produces a unique electron injector—expanding phase-controlled undulating bubble (EPUB). The longitudinal structure of the electron bunch injected by the EPUB can be controlled by laser polarization and power, resulting in high-charge (multiple nano-Coulombs) high-current (tens of kilo-amperes) electron beams with ultra-short (femtosecond-scale) temporal structure. Generation of high-energy betatron radiation with polarization- and CEP-controlled energy spectrum and angular distribution is analyzed as a promising application of EPUB-produced beams.
Long-range electric vehicles (EVs) require high-energy-density batteries that also meet the power demands of high current charge and discharge. Ultra-thick (>100 μm) Lithium-ion battery electrodes are critical to enable this need, but slow ion transport in conventional uniform electrodes (UEs) reduces battery capacity at increasing charge/discharge rates. We present a 3D computational analysis on the impact of structured electrode (SE) and graded electrode (GE) geometries on the discharge rate capability of ultra-thick graphite|LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC-622) battery cells based on the footprint of a commercial EV pouch cell. SE cathodes with either a “grid” or “line” geometry and GEs with two layers of porosity were modeled. Based on the results of 230 models, we found that the electrolyte volume fraction is a key parameter that impacts capacity improvements in UEs, GEs, and SEs at 2 C–6 C discharge rates. SEs have the greatest discharge rate capability, outperforming GEs and UEs due to reduced Lithium-ion concentration gradients across the electrode thickness, which mitigates electrolyte depletion at high rates. The best SE model has a “grid” geometry with gravimetric and volumetric energy density improvements of 0.9%–4% at C/2–2 C and 18%–24% at 4 C–6 C relative to UEs.
As part of the U.S. DOE EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization was conducted over a wide range of DC output current and DC voltage charging for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2023 study conducted on electric vehicle supply equipment (EVSE) characterization by Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) include one 350 kW capable EVSE using a liquid-cooled combined charging system-1 (CCS-1, North American version) cable and connector and an ORNL-developed 100-kW polyphase wireless charger. Characterization results during nominal operation show the AC-to-DC power transfer efficiency for the 350kW conductive EVSE is 95.1% peak and is >92% when the AC power is at least 50 kW. The power quality of the 350 kW conductive EVSE is also measured during nominal conditions. The power factor is >0.91 for power transfer above 50 kW AC input during nominal conditions with a maximum power factor of 0.975. The AC current harmonics produced by the EVSE as measured at the AC input connection to the EVSE is <25% harmonics for power transfer greater than 50 kW and <10% harmonics for power transfer greater than 180 kW.
The current project developed a novel HT-CALPHAD/DFT approach, which can quickly design new high-performance structural alloys for the application of FE power plants. The PI will mainly take charge of high-throughput DFT simulations and computational thermodynamics of the selected multicomponent alloy systems for the FE power plant applications. At the end of the project, a novel hybrid model based on high throughput CALPHAD/DFT simulations and computational thermodynamics will be developed to provide guidance on how to identify multi-component new high-performance structural alloys with much less computational effort needed. It will address the extensive computation time needed for DFT on the new alloys design. In addition, it will also address the well-known headache of DFT, i.e. how to make the accurate prediction of the high-temperature equilibria. The novel hybrid model the PI proposed will not only be applied to the design of high-performance structural alloys in FE power plants but in many different applications, such as nuclear reactors. This hybrid modeling approach includes four sections: 1) HT-CALPHAD modeling of Al-Co-Cr-Ni-Fe system with FCC and BCC phase. In this section, 3561 non-equiatomic compositions were randomly generated in order to investigate the phase stability of single FCC and BCC phases. Meanwhile, we proposed a data screening procedure to screen out the good candidates within these compositions, considering the temperature range, average density, and melting temperature, etc. 2) Investigation of FCC-Cr lattice stability in Fe-Cr system. We systematically assessed the reliability of FCC-Cr lattice stability derived by DFT and CALPHAD approaches. Meanwhile, the Fe-Cr binary system was chosen as a case study to verify the Cr lattice stability obtained by both approaches. 3) High-throughput DFT modeling on elastic properties of Al-Co-Cr-Ni-Fe systems. We predicted and established the FCC quinary elastic constant database of the Al-Co-Cr-Fe-Ni systems at 0K by using special quasi-random structure (SQS) approach. The predictions will start with pure elements of Al-Co-Cr-Fe-Ni system and will be continued with binaries, ternaries, quaternaries, and finally the quinary compositions. 3) Modeling of temperature-dependent elastic properties in Al-Co-Cr-Ni-Fe systems. In this part, we predict the thermal expansion coefficient and elastic stiffness coefficient as a function of temperature by applying quasiharmonic approximation. With this approach, the elastic properties of HEAs at elevate temperature can be estimated.
In this work, magnetic field emission (MFE) of the high-power double-D (DD) coil-based wireless charging system is investigated and a shielding technique is proposed. The MFE pattern produced by the DD coils is significantly different from the MFE of the unipolar (e.g., circular, square, or rectangular) coils, and the traditional aluminum shield does not suppress the MFE from the DD coils. This study shows that a conventional aluminum shield increases the MFE, and a magnetic shield effectively suppresses the MFE of the DD coils. Therefore, a magnetic shield consisting of high-permeability magnetic material, such as ferrites, nanocrystalline, etc., is proposed for the DD pads. The shielding effectiveness of the proposed shield is evaluated through finite element analysis and verified through experiments. An 11 kW DD coil-based wireless charging system was used to test the proposed shielding technique. The experimental results show that a traditional aluminum shield increased the MFE by 29.8%, and the proposed magnetic shield suppressed the MFE by 50.5%.
The cost and manufacturing difficulty of traditionally wound coils for wireless charging of electric vehicles has led to the exploration of alternative manufacturing for scalable deployment at a range of rated powers. A rotating-field polyphase wireless coupler is developed with balanced fully pitched coils which are not possible with conventional Litz wire. The usage of printed circuit board (PCB) technology is proposed for the innovative construction at large dimensions due to reduced cost, increased ease of manufacturability, and potential geometric customization compared to would coils. Design considerations specific to PCBs are detailed for wireless power transfer coils including advantages such as the potential for many turns and transposition with planar interconnections. A design procedure is developed which may be used to investigate the frequency to power to dimension correlation and limits associated with PCB coils. Designs are simulated in 3D electromagnetic finite element analysis (FEA) for the polyphase coil to evaluate the coupling between coils with varying geometric parameters at 100mm and 500mm outer diameters. A discussion is included on methods to increase PCB power ratings through a mixture of layer stacking, connections, and material selection.
Power gateways in the form of a microgrid can incorporate multiple distributed energy resources (DER) in either grid forming or grid following mode and support high performance computing (HPC) power profiles including the large load-follow requirements observed in multi-user HPC systems. The microgrid’s flexibility to operate in either grid forming or grid following mode and to actively switch between these modes enables baseline power from multiple non-baseline DER while maintaining high power quality metrics for the HPC system. But this enormous flexibility in demand response and time of use shifting is generally programmed independently of any integration with an HPC job scheduler which can better inform the load shaping by the microgrid. While there are many existing approaches where the HPC job scheduler takes in information from the grid to make queue scheduling decisions, this work takes the opposite view and explores a scheduler where the jobs in the queue can directly impact the settings of the grid. Several HPC scheduler strategies are tested where the jobs in the queue directly impact the settings of a microgrid designed for HPC operation which is driving a datacenter with three classes of HPC architectures. The scheduler operation is shown using a microgrid with 64 kW of solar capacity and 320 kWh of battery over a period of 21 days operating with significant low-follow swings, a throttled grid, cloudy conditions, switching between grid following and grid forming modes, and a wide range of battery states-of-charge all while maintaining high quality power metrics. The scheduler provides a mechanism for the job queue to directly impact a power gateway like a microgrid and to improve HPC power outcomes such as maximizing renewable energy usage
Abstract Sustainability and supply‐chain concerns require lithium‐ion batteries (LIBs) free from critical minerals, such as nickel and cobalt. While recent advances provide encouraging signs that cobalt can be removed, the question remains how much Ni can be removed from Co‐free layered oxide cathodes before sacrificing critical performance metrics. This study highlights the effect of reducing Ni by benchmarking several Co‐free cathodes with decreasing Ni content. Keeping the energy density the same by increasing the charge voltage, cathodes below 80% Ni content exhibit worsened capacity fade due to increasing oxygen release and electrolyte decomposition. Charge transfer and diffusion kinetics are also hindered with increasing Mn content and exacerbated by resistive surface phases formed at high voltages, rendering lower‐Ni, Co‐free cathodes less competitive than high‐Ni cathodes for high energy and power applications. It is demonstrated blending layered oxide with olivine as an effective alternative to deliver energy density and cycling stability comparable to lower‐Ni cathodes with moderate charging voltages. Blending with 30 wt% olivine LiMn 0.5 Fe 0.5 PO 4 (LMFP) virtually eliminates the diffusion limitation of layered oxides at low state‐of‐charge, with enhanced pulse power characteristics rivaling the high‐Ni counterparts. Cathode blending can further reduce the overall Ni content and cost without the performance limitations of lower‐Ni, Co‐free cathodes.
In 2008, Michigan State University was selected to establish the Facility for Rare Isotope Beams (FRIB). Construction of the FRIB accelerator was completed in January 2022. Phased accelerator commissioning with heavy ion beams started in 2017 with the normal-conducting ion source and radio-frequency quadrupole. In April 2021, the full FRIB driver linear accelerator (linac) was commissioned, with heavy ion beams accelerated to energies above 200 MeV/nucleon by 324 superconducting radiofrequency (SRF) resonators operating at 2 K and 4 K with liquid-helium cooling. Further, in preparation for high-power operation, a liquid lithium charge stripper was commissioned with heavy ion beams up to uranium-238, followed by the simultaneous acceleration of multiple-charge-state heavy ion beams to energies above 200 MeV/nucleon. In December 2021, selenium-84 was produced with the FRIB target using a krypton-86 primary beam, demonstrating FRIB’s capability for scientific discovery.
A high performance kilowatt-scale large air-gap multi-modular capacitive wireless power transfer (WPT) system is provided for electric vehicle (EV) charging. In one particular implementation, the multi-modular system achieves high power transfer while maintaining fringing electric fields within prescribed safety limits. The fringing fields are reduced using near-field phased-array field-focusing techniques, wherein the adjacent modules of the multi-modular system are out-phased with respect to one another. The inter-module interactions in this multi-modular system can be modeled, and an approach to eliminate these interactions in a practical EV charging environment is provided. To illustrate one example implementation, a prototype 1.2-kW 6.78-MHz 12-cm air-gap multi-modular capacitive WPT system comprising two 600-W modules is provided. This prototype system achieves 21.2 kW/m2 power transfer density and a peak efficiency of 89.8%. This multi-modular system also achieves a fringing field reduction of 50% compared to its individual modules.
This talk to the National Association of Regulatory Utility Commissioners (NARUC) focuses on "Aligning Electric Vehicle Customer Charging with Grid Needs" to highlight the opportunities associated with managed electric vehicle charging and its value for consumers and the power system. Electric vehicles (EVs) are experiencing a rapid rise in popularity and adoption, and growing EV adoption offers an opportunity to increase electricity demand. With expected widespread EV adoption, supporting charging will require investments in generation, transmission, and distribution systems. Uncoordinated charging of EVs will lead to increased system peak load, possibly exceeding the maximum power that can be supported by distribution systems and generally increasing power system stress. However, vehicles are underutilized assets parked ~96% of the time: managed EV charging can satisfy mobility needs while also supporting the grid. EVs are not a burden for the grid, but a resource: The demand-side flexibility provided by managed EV charging offers significant potential benefits for the grid over multiple timescales and applications., especially for high-renewable systems. Managed charging can support power system planning and operations during normal and extreme conditions, benefitting EV owners and other electricity consumers. Managed charging is shown to consistently provide hundreds of dollars in cost savings per EV each year.
In this paper, the thermal analysis of a 50 kW three-phase wireless charging system (WCS) is presented. Addressing the thermal challenge is essential for designing a compact charging pad for 50 kW and higher-power WCS pads. Low thermal conductivity of the Litz wire and ferrite, and uneven distribution of the coil, and core loss cause the high temperature in the charging pads. In this paper, the loss distribution of a 50 kW three-phase WCS is investigated, and the temperature distribution is simulated using finite element analysis (FEA) considering the magnetic and non-magnetic materials of a charging pad. The thermal characteristics of an extremely high-power density 50 kW WCS prototype are tested experimentally for 10 minutes of operation. The simulation and experimental results show that the coil temperature increases to 65°C, the core temperature varies between 50°C to 150°C, and the packaging temperature increases to 65°C after 10 minutes of operation at rated 50 kW output power.