Search NASA⌕ Search

SEARCH · Search NASA

Results for “high precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Load-deflection tests and computer analyses of a high-precision adhesive-bonded antenna reflector panel

New adhesive-bonded panels are being investigated as a part of an effort to extend and upgrade the 64-m to a 70-m antenna network. Load-deflection tests were conducted on a sample high-precision adhesive-bonded panel for comparison with design criteria. Two computerized structural models were developed in order to predict the deformation patterns under different types of distributed and concentrated loadings. The main purpose was to obtain empirical stiffness factors for the slit beams and girders in the panel structure. With determination and use of the empirical stiffness factors, there is a good agreement between the theoretically predicted deflections and the test measurements. It was also found that the new bonded panels satisfy the stringent design specifications and surface tolerance bounds.

Chian, C. T.↗

Research on the Problem of High-Precision Deployment for Large-Aperture Space-Based Science Instruments

The present paper summarizes results from an ongoing research program conducted jointly by the University of Colorado and NASA Langley Research Center since 1994. This program has resulted in general guidelines for the design of high-precision deployment mechanisms, and tests of prototype deployable structures incorporating these mechanisms have shown microdynamically stable behavior (i.e., dimensional stability to parts per million). These advancements have resulted from the identification of numerous heretofore unknown microdynamic and micromechanical response phenomena, and the development of new test techniques and instrumentation systems to interrogate these phenomena. In addition, recent tests have begun to interrogate nanomechanical response of materials and joints and have been used to develop an understanding of nonlinear nanodynamic behavior in microdynamically stable structures. The ultimate goal of these efforts is to enable nano-precision active control of micro-precision deployable structures (i.e., active control to a resolution of parts per billion).

Lake, Mark S.↗

Computation and consequences of high order amplitude- and parameter-dependent tune shifts in storage rings for high precision measurements

Nonlinear effects of the various electric field and magnetic field components of storage rings to confine the particles and bend their trajectory can cause substantial amplitude-dependent tune shifts within the beam. Furthermore, tune shifts are often sensitive to variations of system parameters, e.g. total particle momentum offsets $δp$. Such amplitude- and parameter-dependent tune shifts influence the dynamics and stability of a beam in particle storage rings. Thus, it is critical for high precision measurements to analyze and understand these influences. On this basis, we present in this paper normal form methods for the calculation of high order amplitude and system parameter dependencies of the horizontal and vertical tunes in storage rings using the differential algebra (DA) framework within COSY INFINITY. A storage ring is simulated using COSY INFINITY to generate a DA Poincaré return map describing the transverse phase space behavior after each revolution in the storage ring. The map is expanded around the parameter-dependent closed orbit of the system before transforming the resulting map into normal form coordinates to extract the high order tune dependencies on the phase space amplitude and variation in the system parameters. As a specific example, a storage ring similar to the Storage Ring of the Muon g-2 Experiment at Fermilab (E989) is investigated.

43 PARTICLE ACCELERATORS↗

Exploring the impact of high-precision top-quark pair production data on the structure of the proton at the LHC

The impact of recent LHC top-quark pair production single differential cross section measurements at 13 TeV collision energy on the structure of the proton is explored. In particular, the impact of these high-precision data on the gluon and other parton distribution functions (PDFs) of the proton at intermediate and large partonic momentum fraction x is analyzed. This study extends the CT18 global analysis framework to include these new data. The interplay between top-quark pair and inclusive jet production as well as other processes at the LHC, is studied. In addition, a study of the impact of scale choice on the theory description of the new 13 TeV t t ¯ measurements is performed. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Deconvolution Approach to Carrier and Code Multipath Error Elimination in High Precision GPS

This paper proposes a novel technique based on the deconvolution approach of the simultaneous estimation and compensation of the multipath estimation errors in both the carrier phase lock and the code delay lock loops in GPS receivers. Simulation results are presented showing that the proposed GPS receiver algorithm achieves high precision in the range and differential range estimation in various GPS precision applications such as spacecraft attitude control, even in a relatively severe multipath environment.

GPS↗

High-precision Penning trap mass measurements of neutron-rich chlorine isotopes at the 𝑁 = 28 shell closure

Although it is known that the N = 28 spherical shell closure erodes, the strength of the closure with decreasing proton number Z < 20 is an open question in nuclear structure. Here, in this region of interest, high-precision mass measurements of neutron-rich 43-45 Cl isotopes were performed at the Low Energy Beam and Ion Trap (LEBIT) when coupled to the National Superconducting Cyclotron Lab. The resulting mass excesses (MEs) are ME(⁴³Cl) = -24114.4(1.7) keV, ME(⁴⁴Cl) = -20450.8(10.6) keV, and ME(⁴⁵Cl) = -18240.1(3.7) keV, and improve the uncertainty of these masses by up to a factor of ∼40 compared to the previous values reported in the 2020 Atomic Mass Evaluation. Comparison to ab initio calculations using the Valence-Space In-Medium Similarity Renormalization Group (VS-IMSRG) shows good agreement up to and including the closure.

Erington, H. [Michigan State Univ., East Lansing, ↗

Spin Transparency Method for High Precision Experiments with Polarized Beams

The spin transparency method is a technique for efficient and flexible control of the beam polarizationin a synchrotron. It can be implemented in a figure-8 collider, a racetrack with two identical Siberiansnakes, as well as in a conventional ring at an energy corresponding to an integer spin resonance.Weak-field magnetic insertions called Spin Navigators provide polarization stabilization and manip-ulation including spin flipping. By compensating the spin effects of imperfections, a real synchrotroncan be turned into an effectively ideal ring from the spin dynamics point of view thus enabling funda-mental ultra-high precision experiments such as search for Electric Dipole Moment and Dark Matter.We discuss the possibility of applying the spin transparency mode at ultra-high energies

Filatov, Yury N.↗

High precision applications of the global positioning system

The Global Positioning System (GPS) is a constellation of U.S. defense navigation satellites which can be used for military and civilian positioning applications. A wide variety of GPS scientific applications were identified and precise positioning capabilities with GPS were already demonstrated with data available from the present partial satellite constellation. Expected applications include: measurements of Earth crustal motion, particularly in seismically active regions; measurements of the Earth's rotation rate and pole orientation; high-precision Earth orbiter tracking; surveying; measurements of media propagation delays for calibration of deep space radiometric data in support of NASA planetary missions; determination of precise ground station coordinates; and precise time transfer worldwide.

Lichten, Stephen M.↗

A high-precision finite element method for shock-tube calculations

A two-pass explicit scheme is developed in order to exploit some of the capabilities of finite difference modeling (FDM) for finite element modeling (FEM), which offers the opportunity to account for any type of geometry in fluid flow modeling. Features of the first-order upwind and the Lax-Wendroff high precision explicit finite difference algorithms are reviewed. A flux limiter is developed for FEM to serve as an analog for the single limiter function which has been defined for the various FDMs. It is shown that an antidiffusive limiter must be introduced into the weighting function which normally multiplies the time-derivative term in the variational equation. The two-pass scheme which results is demonstrated to be the equivalent of FDMs with five-point support. However, the present scheme is valid only for one-dimensional calculations and linear shape functions for shock tube flow phenomena. Further work is required for its use with nonlinear hyperbolic systems.

Hughes, T. J. R.↗

Graphic overlays in high-precision teleoperation: Current and future work at JPL

In space teleoperation additional problems arise, including signal transmission time delays. These can greatly reduce operator performance. Recent advances in graphics open new possibilities for addressing these and other problems. Currently a multi-camera system with normal 3-D TV and video graphics capabilities is being developed. Trained and untrained operators will be tested for high precision performance using two force reflecting hand controllers and a voice recognition system to control two robot arms and up to 5 movable stereo or non-stereo TV cameras. A number of new techniques of integrating TV and video graphics displays to improve operator training and performance in teleoperation and supervised automation are evaluated.

Diner, Daniel B.↗

The Asymmetric, Dual-Michelson Wavefront Corrector: High Precision Correction of Amplitude and Phase for Coronagraphy

To detect extra-solar planets by coronography will require unprecedented levels of wavefront correction of both phase and amplitude. To achieve this, we propose a dual Michelson interferometer arrangement, incorporating two deformable mirrors (DM) and a third, fixed mirror (all at pupils) and two beamsplitters: one with unequal (asymmetric) beam splitting and one with symmetric beamsplitting. This design allows high precision correction of phase and amplitude using DMs with relatively coarse steps and is relatively insensitive to small changes in the DMs. We are constructing such an apparatus incorporating two MEMS devices and will report on features of the design and performance.

Bowers, Charles↗

The Asymmetric, Dual-Michelson Wavefront Corrector: High Precision Correction of Amplitude and Phase for Coronagraphy

To detect extra-solar planets by coronagraphy will require unprecedented levels of wavefront correction of both phase and amplitude. To achieve this, we propose a dual Michelson interferometer arrangement, incorporating two deformable mirrors (DM) and a third, fixed mirror (all at pupils) and two beamsplitters: one with unequal (asymmetric) beam splitting and one with symmetric beamsplitting. This design allows high precision correction of phase and amplitude using DMs with relatively coarse steps and is relatively insensitive to small changes in the DMs. We are constructing such an apparatus incorporating two MEMS devices and will report on features of the design performance.

Bowers, Charles↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

A high precision Solar Ultraviolet Spectral Irradiance Monitor for the wavelength region 120-400 nm

There exists a growing need to improve the accuracy of measurement of the absolute solar flux within the wavelength range 120-400 nm. Although full-disk solar fluxes and variations thereof in the 120-400 nm region are required to model the solar atmosphere, current increased interest in the measurements arises from their importance in modeling the terrestrial atmosphere. The Solar Ultraviolet Spectral Irradiance Monitor (SUSIM) experiment under development for flight aboard the Space Shuttle and the Upper Atmospheric Research Satellite is described. SUSIM will monitor the solar flux in the 120-144 nm region with high precision, using an in-flight calibration system to reduce absolute error to less than 10%, and error relative to the 400 nm continuum to less than 1%.

Vanhoosier, M. E.↗

High precision lunar tracking for laser ranging

Laser ranging to lunar surface retroreflectors has provided a valuable source of data for the investigation of the lunar orbit, the earth's orientation in space, general relativity, and many other aspects of solar system dynamics. Due to the moon's relatively large distance, and the requirement to keep the beam from the relatively low-power laser very narrow, acquiring this data type requires very accurate telescope pointing and tracking capabilities. The nominal requirement is to keep the telescope on target within approximately 1 arcsec of its predicted location for at least several minutes. An expansion of this requirement and the methods used to accomplish this high precision pointing are presented. Difficulties encountered and a few future goals of automating the McDonald station are also discussed.

Ricklefs, Randall L.↗

High Precision Penning Trap Measurements of beta-decay Q-values for Neutrino Physics

The 2015 Nobel Prize in physics was awarded to Takaaki Kajita and Arthur B. McDonald “for the discovery of neutrino oscillations, which shows that neutrinos have mass”. This fact has wide reaching implications for the standard model of particle physics, nuclear physics, and cosmology. However, important fundamental questions remain: What is the absolute neutrino mass scale? Is the neutrino a Majorana or a Dirac particle? A number of large-scale experiments are underway or are being developed to attempt to answer these questions. Two classes of experiments are direct neutrino mass determination experiments, and searches for neutrinoless double betadecay. This work aimed to aid these experiments via high-precision Q value determinations for the relevant isotopes using Penning trap mass spectrometry (PTMS).

42 ENGINEERING↗

Imaging Technique for High Precision Measurement of Detector Stability for the Ocean Color Instrument

One of the new projects by NASA to explore environmental change is the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) spacecraft. The primary instrument aboard the PACE spacecraft is the Ocean Color Instrument (OCI), an advanced optical spectrometer that will measure the color of the ocean from the ultraviolet to shortwave infrared range for the purpose of observing and monitoring ocean and coastal biology. As part of the optical alignment testing that must be completed before the instrument is built, the measurement stability of the detectors at space flight operating temperatures must be determined to ensure alignment is maintained. Therefore, this project focuses on the development of an imaging technique that adheres to testing requirements and can be used to determine the stability of the OCI detector. The movements of targets affixed to a high-precision stage were analyzed through an image processing program to test the ability of the imaging technique to detect very small (under 10 micrometers) movements. It was found that movements as small as half a pixel (~6 microns) and 1 pixel (~12 microns) were able to be accurately and consistently detected with this imaging technique. This project found that the designed image analysis technique fulfills testing and measurement requirements and will be an effective metrology technique for the OCI detector stability test.

Optics↗