Search NASA⌕ Search

SEARCH · Search NASA

Results for “high resolution detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Scintillating crystals for the Neutral Particle Spectrometer in Hall C at JLab

This report discusses the quality and performance of currently available PbWO crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron–Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO 4 production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discorpy : algorithms and software for camera calibration and correction

Camera or lens-based detector calibration is essential for spatial accuracy in applications like dimensional tomography, optical metrology, and computer vision. Many methods and software exist yet there is still a lack of approaches that achieve both high accuracy and robustness while being easy to use and capable of handling a wide range of distortions. Radial lens distortion is common in high-resolution X-ray detector optics used in parallel-beam tomography at synchrotrons. Achieving sub-pixel accuracy requires calibrating with an optical target image. Although methods for characterizing radial distortion are well established, acquired images often also include perspective distortion and optical center offset. Here, we present our approaches to individually characterize and correct both types of distortion using a single calibration image, implemented in the Discorpy software.

36 MATERIALS SCIENCE↗

Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.

36 MATERIALS SCIENCE↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low mass dark matter-electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross-sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axion-like particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The JLab Eta Factory (JEF) experiment

The new experiment, JLab Eta Factory (JEF), in the experimental Hall D at Jefferson Lab will extend the physics potential of the GlueX detector beyond the main spectroscopy program and perform precision measurements of various ?(?)decays with emphasis on rare neutral modes. The physics program of the experiment spans from precision tests of low-energy QCD to search of gauge bosons in the mass range below 1 GeV coupling the SM sector to the dark sector. Photoproduction of highly boosted ?(?)mesons using a tagged photon beam, good detection of recoil proton and multi-photon final states will allow to suppress background and collect high-statistics data sample of ?mesons. All these provide many advantages over other ?(?)experiments. The JEF experiment requires to upgrade the inner part of the forward lead glass calorimeter of the GlueX detector with high-granularity, high-resolution lead tungstate PbWO4 scintillating crystals. The calorimeter insert is currently under construction at Jeffeson Lab. The detector will be ready to take data in 2024. An overview of the JEF project will be presented.

Somov, Alexander↗

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV detector

We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of 6.1 g · days of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as 1 MeV/𝑐 2 , as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses >1.2 eV/𝑐 2 probed via absorption processes.

dark matter direct detection↗

High-precision Measurement of the 16 O($n, n'γ$) Cross Section using $γ$-ray Detection in Liquid Scintillators with H 2 O and BeO Targets

The 16 O($n, n'γ$) reaction was measured at the Los Alamos Neutron Science Center white neutron source using γ-ray detection in liquid scintillators present in the upper hemisphere of the Correlated Gamma-Neutron Array for sCattering (CoGNAC). Separate measurements of this reaction were performed using H 2 O and BeO targets in successive years. The unique high energies of γ rays emitted from the 16 O($n, n'γ$) reaction facilitated a clean selection of this reaction from threshold to 9.8 MeV incident neutron energy without the need for precise measurements of the γ-ray energy or the scattered neutrons. The precise time resolution of the liquid scintillator detectors was then exploited to obtain high-resolution incident neutron energy measurements, and good agreement was obtained between the H 2 O and BeO results reported here. The dominant literature data sets for this reaction have systematic differences between them, but the present results improve upon the neutron energy resolution of earlier measurements and show important discrepancies in recent data. Finally, tentative data are also shown up to 20 MeV incident neutron energy but are potentially subject to improved understanding of the relative γ-ray and α decay branches from 16 O excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

239 Pu Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 239 Pu. Fission was induced in a pure 239 Pu (>99%) target using the Godiva IV critical assembly in burst mode. Further, the irradiated sample was transferred to a high-resolution γ-ray detector within 45 minutes. γ-ray list mode data was collected from 45 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. The initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solution processed high aspect ratio ultra-long vertically well-aligned ZnO nano scintillators for potential X-ray imaging applications

We report the photon (PL), electron (CL) and X-ray (XEL) induced luminescence characteristics of high aspect ratio ultra-long (~ 50 µm) ZnO nanorods (NRs) and discuss the potential for fast X-ray detection based on the consistent and efficient visible emission (~ 580 nm) from ZnO NRs. Nanostructured ZnO scintillators were rearranged to form a vertically well-aligned NR design in order to help light absorption and coupling resulting in luminescent and fast scintillation properties. The design of the nanorod array combines the key advantages of a low-cost growth technique together with environmentally friendly and widely available materials. A low temperature hydrothermal method was adopted to grow ZnO NRs in one cycle growth and their structural, optical and X-ray scintillation properties were investigated. The relatively short (~ 10 µm) ZnO NRs emitting in the near-band-edge region were found to be almost insensitive to X-rays. On the other hand, the higher XEL response of long ZnO NRs, which is a key parameter for evaluation of materials to be used as scintillators for high quality X-ray detection and imaging, along with a decay time response in the order of ns confirmed promising scintillation properties for fast and high-resolution X-ray detector applications.

47 OTHER INSTRUMENTATION↗

A Decade of GRETINA Science

High-resolution γ-ray detector arrays have driven many scientific advances and discoveries in nuclear physics. Today, they provide a powerful and essential tool for a broad class of measurements in the study of nuclear structure and reactions, nuclear astrophysics, and applied nuclear science. In this article, we present an overview of the scientific program that has been enabled by the γ-ray tracking array GRETINA [Pas13]. This program is being carried out at both stable and radioactive ion beam facilities, employs a wide range of beam energies and reactions (from the Coulomb barrier to more than 30% the speed of light), and reflects the varied application of a γ-ray tracking array.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fabrication of 4H-SiC Low Gain Avalanche Detectors (LGADs)

Low gain avalanche detectors (LGADs) offer high temporal resolution for high energy particle detection, which is critical for next generation experiments in hadron colliders. While silicon LGADs (Si-LGADs) have rapidly matured in the last decade, research into silicon carbide (SiC) LGADs has only recently begun. By accounting for fundamental differences in material properties and fabrication processes, we present a prototype device design and process flow for 4H-SiC LGADs with etch-based isolation. Critical steps of the process flow and their results are discussed, including plasma etching, passivation, and the formation of low resistivity contacts. Electrical characterization (I-V, C-V) shows sufficient depletion of the device structure to demonstrate low-gain charge carrier multiplication.

High Energy Physics↗

Growth of Cd 0.9 Zn 0.1 Te 1-y Se y Single Crystals for Room Temperature Gamma-Ray Detection

Quaternary Cd 0.9 Zn 0.1 Te 1-y Sey (CZTS) single crystals, a novel room-temperature nuclear radiation detector semiconductor material, have been grown using a modified vertical Bridgman method (VBM) and a travelling heater method (THM). The percentage concentration of selenium in the VBM-grown crystal was 3% and that in the THM-grown crystal was 2%. While the THM Frisch collar detector (4.4 × 4.4 × 10.7 mm 3 ) produced a highly resolved pulse height spectra (PHS) with a resolution of ~1.06% for 662-keV gamma rays without any correction, the VBM-grown detector (10 × 10 × 2 mm 3 ) offered a high energy resolution of ~2% after application of a digital biparametric correction. The high-resolution performance of these detectors has been attributed to the addition of Se in the Cd 0.9 Zn 0.1 Te (CZT) matrix. Ab-initio calculations based on density functional theory (DFT) also confirmed that the addition of Se in the CZT matrix helps to reduce the formation of TeCd and the TeZn anti-sites. The VBM-grown crystals were characterized using powder x-ray diffraction (XRD) and energy dispersive x-ray spectroscopy (EDS). While XRD results revealed sharp diffraction peaks confirming the crystalline nature of the grown crystal, the EDS results confirmed the targeted stoichiometry of the elemental composition. The bulk resistivity of the grown crystal was calculated to be ~3 × 10 10 Ω-cm from current-voltage characteristics recorded at room temperature in a planar configuration, ensuring that the grown CZTS crystals have low dark current as required for detector-grade crystals.

42 ENGINEERING↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗