Search NASA⌕ Search

SEARCH · Search NASA

Results for “high variable generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Development of a 95-Year Solar Dataset for Resource Adequacy Studies

Long-term high-resolution solar data provides enhanced understanding of variability of solar generation and enhances our ability to develop strategies for a resilient and reliable electric grid under high deployment of solar energy. Therefore, it is important to develop long-term synthetic datasets that can provide multiple occurrences of various severe weather scenarios that are expected to test the limits of resource adequacy under scenarios contain various energy generation sources. Examples of such scenarios could be long periods of high temperatures when demand for electricity is high or periods where high winds could lead to a shut-down of transmission lines for long periods of time to ensure fire safety. NREL has developed the first version of such a dataset covering a 95-year period covering 2006-2100 at a 4km hourly resolution. This dataset contains all variables necessary to calculate solar generation. During development of this dataset, we focused on creating unbiased, high-resolution solar irradiance through statistical downscaling methods, using Regional Climate Model (RCM) simulations from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) as input. The National Solar Radiation Database (NSRDB) containing over 25 years of observations was used to calibrate the statistical downscaling models. This presentation will outline the primary steps in developing this dataset, including (1) regridding RCM data to a common grid at 20-km resolution, (2) correcting RCM biases with NSRDB, (3) applying temporal and spatial downscaling methods to generate high-resolution (4-km, hourly) solar and ancillary data. Additionally, we will present an evaluation of the downscaled data against the NSRDB across various zones in the CONUS. Lastly, we will present a user guide for accessing the datasets.

14 SOLAR ENERGY↗

Evaluating the Methodologies of Assessing Long-Term Variability of Wind Speed

Wind resources vary from year to year, and hence the long-term variability of wind speed is a key component of the overall uncertainty in the wind resource assessment process. Because wind-turbine power generation is highly sensitive to wind speed, the variability of wind resources has important implications for renewable power production. As many approaches of calculating the spread of distribution exist, we aim to identify the methods most appropriate for all types of wind-speed distributions. We review and compare various methods, such as the Coefficient of Variation (CoV) and the Robust Coefficient of Variation (RCoV). Because the length of data available also affects the resultant spread, we determine the minimum length of wind-speed records to quantify variability accurately. We use the net monthly energy production of 607 wind farms in the United States from the Energy Information Administration and the wind speeds of the MERRA-2 reanalysis dataset from NASA. After filtering the energy data via linear regression, we assess the accuracy of the variability calculations by comparing the correlations between the wind-speed variability estimates and the variabilities of wind-farm power productions. Results from statistically robust and resistant methods yield higher correlations between wind-speed and energy-production variabilities, as robust methods do not assume Gaussian wind-speed distributions and resistant methods are insensitive to wind speed extremes. We recommend RCoV to systematically estimate long-term variability, with 10 years of monthly mean data to achieve 90% statistical confidence. We will also provide generalized guidance on how to estimate long-term variability including case studies where we identify regions with high wind speeds and low wind-speed RCoVs, such as the Great Plains and the Upper Midwest in central United States.

17 WIND ENERGY↗

Variability in Wind Energy Generation across the Contiguous United States

ERA5 provides high-resolution, high-quality hourly wind speeds at 100 m and is a unique resource for quantifying temporal variability in likely wind-derived power production across the United States. Gross capacity factors (CF) in seven independent system operators (ISOs) are estimated using the location and rated power of each wind turbine, a simplified power curve, and ERA5 output from 1979 to 2018. Excluding the California ISO, the marginal probability of a calm (zero power production) is less than 0.1 in any ERA5 grid cell. When a calm occurs, the mean co-occurrence across wind-turbine-containing grid cells ranges from 0.38 to 0.39 for ISOs in the Midwest and central plains [Midcontinent (or Midwest) ISO (MISO), Southwest Power Pool (SPP), and the Electric Reliability Council of Texas (ERCOT) region], increasing to 0.54–0.58 for ISOs in the eastern United States [Pennsylvania–New Jersey–Maryland interconnection (PJM), New York ISO (NYISO), and New England ISO (NEISO)]. Periods with low gross CF have a median duration of ≤6 h, except in California, and are most likely during summer. Additionally, gross CF exhibit highest variance at periods of 1 day in ERCOT and SPP; on synoptic scales in MISO, NEISO, and NYISO; and on interannual time scales in PJM. This implies differences in optimal strategies for ensuring resilience of supply. Theoretical scenarios show adding wind energy capacity near existing wind farms is advantageous even in areas with high existing installed capacity (IC), while expanding into areas with lower IC is more beneficial to reducing ramps and the probability of gross CF falling below 20%. These results emphasize the benefits of large balancing areas and aggregation in reducing wind power variability and the likelihood of wind droughts.

17 WIND ENERGY↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Exploring the Effects of Installation Geometry in High-Lift Propeller Systems

A high-lift propeller system is a distributed electric propulsion technology which dedicates an array of wing-mounted tractor propellers to actively augment wing lift during takeoff and landing. This paper describes the results of a wind tunnel experiment dedicated to investigating the effects of high-lift propeller installation geometry on lift generation. Variables investigated include propeller height, offset, and inclination. Results show that propeller height is the most critical variable and that the height for maximum lift depends highly on the angle of attack and flap deflection. In addition, a relationship between optimal propeller height and the wing’s unblown lift coefficient is discovered.

Fei, Xiaofan↗

Dynamic Analysis of Hybrid Energy Systems under Flexible Operation and Variable Renewable Generation -- Part I: Dynamic Performance Analysis and Part II: Dynamic Cost

Dynamic analysis of hybrid energy systems (HES) under flexible operation and variable renewable generation is considered in order to better understand various challenges and opportunities associated with the high system variability arising from the integration of renewable energy into the power grid. Unique consequences are addressed by devising advanced HES solutions in which multiple forms of energy commodities, such as electricity and chemical products, may be exchanged. Dynamic models of various unit operations are developed and integrated within two different HES options. One HES option, termed traditional, produces electricity only and consists of a primary heat generator (PHG) (e.g., a small modular reactor), a steam turbine generator, a wind farm, and a battery storage. The other HES option, termed advanced, includes not only the components present in the traditional option but also a chemical plant complex to repurpose excess energy for non-electricity services, such as for the production of chemical goods (e.g., transportation fuel). In either case, a given HES is connected to the power grid at a point of common coupling and requested to deliver a certain electricity generation profile as dictated by a regional power grid operator based on a predicted demand curve. Dynamic analysis of these highly-coupled HES are performed to identify their key dynamical properties and limitations and to prescribe solutions for best managing and mitigating the high variability introduced from incorporating renewable energy into the energy mix. A comparative dynamic cost analysis is also conducted to determine best HES options. The cost function includes a set of metrics for computing fixed costs, such as fixed operations and maintenance (O&M) and overnight capital costs, and also variable operational costs, such as cost of variability, variable O&M cost, and cost of environmental impact, together with revenues. Assuming different options for implementing PHG (e.g., natural gas, coal, nuclear), preliminary results identify the level of renewable penetration at which a given advanced HES option (e.g., a nuclear hybrid) becomes increasingly more economical than a traditional electricity-only generation solution. Conditions are also revealed under which carbon resources may be better utilized as carbon sources for chemical production rather than as combustion material for electricity generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Value of High Spatial Resolution in National Capacity Expansion Models using ReEDS

Power sector capacity expansion models (CEMs) have a broad range of spatial resolutions. This paper uses the Regional Energy Deployment System (ReEDS) model, a long-term national scale electric sector CEM, to evaluate the value of high spatial resolution for CEMs. ReEDS models the United States with 134 load balancing areas (BAs) and captures the variability in existing generation parameters, future technology costs, performance, and resource availability using very high spatial resolution data, especially for wind and solar modeled at 356 resource regions. In this paper we perform planning studies at three different spatial resolutions--native resolution (134 BAs), state-level, and NERC region level--and evaluate how results change under different levels of spatial aggregation in terms of renewable capacity deployment and location, associated transmission builds, and system costs. The results are used to ascertain the value of high geographically resolved models in terms of their impact on relative competitiveness among renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Representing the Future Role of Hydropower and Pumped Storage Hydropower (PSH) in Electricity Planning Tools

Existing tools for long-term electric sector planning struggle to represent hydropower's nuanced site-specific technical and operating characteristics, which depend on technical specifications as well as water management practices and regulations. As a result, long-term planning models and tools insufficiently characterize hydropower value and incentives, and they cannot fully represent the role hydropower can play in a future electricity system that could include a high penetration of variable wind and solar generation, battery storage, and other low-carbon technologies. This presentation demonstrates the culmination of a multi-year effort to enhance hydropower representations in electricity planning models at the National Renewable Energy Laboratory (NREL), as part of the U.S. Department of Energy (USDOE) HydroWIRES Initiative. New modeling techniques are demonstrated using the NREL Regional Energy Deployment System (ReEDS), an open-access electric sector capacity expansion model used extensively in a wide range of technology deployment and integration analysis, including the 2016 USDOE Hydropower Vision. ReEDS uses a least-cost optimization approach to understand investment and operation of electricity generation, storage, and transmission technologies under future scenarios of electricity technology innovation, demand, policy, and other sectoral drivers. ReEDS was modified to better represent value and opportunities for both pumped storage hydropower (PSH) and hydropower systems without pumping. We incorporated a new national closed-loop PSH resource and cost assessment to explore new PSH deployment opportunities and added plant-level data to better represent the existing PSH fleet. New upgrade pathways enable opportunities for enhanced hydropower flexibility by adding pumps, upgrading dispatchability, increasing capacity, or increasing energy availability. The model was also modified to better represent the value of long-duration energy storage beyond diurnal time scales, allowing both hydropower and PSH to better balance energy supply and demand variations in high-renewable systems. These new features are demonstrated under reference and high-renewable futures and a range of sensitivity scenarios to understand which hydropower and PSH deployment and upgrade opportunities are the most attractive. These scenarios indicate potential for new closed-loop PSH deployment and for hydropower flexibility improvements to have important impacts on long-term electricity system emissions and economic outcomes. Increasing flexibility of the existing hydropower fleet can reduce the need to invest in new flexible grid technologies and help achieve decarbonization goals. Systems with sufficient energy storage could also be valuable for balancing seasonal differences in renewable energy availability, particularly from solar energy. The methods developed for ReEDS and subsequent scenario results reveal important considerations for future hydropower and grid system planning, and all data and code is freely available in a public code repository for use throughout the hydropower industry.

capacity expansion↗

Stress Testing California's Hydroclimatic Whiplash: Potential Challenges, Trade‐Offs and Adaptations in Water Management and Hydropower Generation

Abstract Inter‐annual precipitation in California is highly variable, and future projections indicate an increase in the intensity and frequency of hydroclimatic “whiplash.” Understanding the implications of these shocks on California's water system and its degree of resiliency is critical from a planning perspective. Therefore, we quantify the resilience of reservoir services provided by water and hydropower systems in four basins in the western Sierra Nevada. Using downscaled runoff from 10 climate model outputs, we generated 200 synthetic hydrologic whiplash sequences of alternating dry and wet years to represent a wide range of extremes and transitional conditions used as inputs to a water system simulation model. Sequences were derived from upper (wet) and lower (dry) quintiles of future streamflow projections (2030–2060). Results show that carryover storage was negatively affected in all basins, particularly in those with lower storage capacity. All basins experienced negative impacts on hydropower generation, with losses ranging from 5% to nearly 90%. Reservoir sizes and inflexible operating rules are a particular challenge for flood control, as in extremely wet years spillage averaged nearly the annual basins' total discharge. The reliability of environmental flows and agricultural deliveries varied depending on the basin, intensity, and duration of whiplash sequences. Overall, wet years temporarily rebound negative drought effects, and greater storage capacity results in higher reliability and resiliency, and lesser volatility in services. We highlight potential policy changes to improve flexibility, increase resilience, and better equip managers to face challenges posed by whiplash while meeting human and environmental needs.

Environmental Sciences & Ecology↗

Piezoelectrostatic Generator

High voltage generated by compact, lightweight equipment. Improved variable-capacitance electrostatic generator relies on piezoelectric effort to convert mechanical energy directly into electrical energy and contains neither transformers nor bulky high-voltage rectifiers. Requires neither external power supply to charge, nor vacuum to insulate electrodes.

Robertson, Glen A.↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗

Enabling Technologies for High Penetration of Wind and Solar Energy

High penetration of variable wind and solar electricity generation will require modifications to the electric power system. This work examines the impacts of variable generation, including uncertainty, ramp rate, ramp range, and potentially excess generation. Time-series simulations were performed in the Texas (ERCOT) grid where different mixes of wind, solar photovoltaic and concentrating solar power provide up to 80% of the electric demand. Different enabling technologies were examined, including conventional generator flexibility, demand response, load shifting, and energy storage. A variety of combinations of these technologies enabled low levels of surplus or curtailed wind and solar generation depending on the desired penetration of renewable sources. At lower levels of penetration (up to about 30% on an energy basis) increasing flexible generation, combined with demand response may be sufficient to accommodate variability and uncertainty. Introduction of load-shifting through real-time pricing or other market mechanisms further increases the penetration of variable generation. The limited time coincidence of wind and solar generation presents increasing challenges as these sources provide greater than 50% of total demand. System flexibility must be increased to the point of virtually eliminating must-run baseload generators during periods of high wind and solar generation. Energy storage also becomes increasingly important as lower cost flexibility options are exhausted. The study examines three classes of energy storage - electricity storage, including batteries and pumped hydro, hybrid storage (compressed-air energy storage), and thermal energy storage. Ignoring long-distance transmission options, a combination of load shifting and storage equal to about 12 hours of average demand may keep renewable energy curtailment below 10% in the simulated system.

14 SOLAR ENERGY↗

Eastern Renewable Generation Integration Study

The Eastern Interconnection (EI) is one of the largest power systems in the world, and its size and complexity have historically made it difficult to study in high levels of detail in a modeling environment. In order to understand how this system might be impacted by high penetrations (30% of total annual generation) of wind and solar photovoltaic (PV) during steady state operations, the National Renewable Energy Laboratory (NREL) and the U.S. Department of Energy (DOE) conducted the Eastern Renewable Generation Integration Study (ERGIS). This study investigates certain aspects of the reliability and economic efficiency problem faced by power system operators and planners. Specifically, the study models the ability to meet electricity demand at a 5-minute time interval by scheduling resources for known ramping events, while maintaining adequate reserves to meet random variation in supply and demand, and contingency events. To measure the ability to meet these requirements, a unit commitment and economic dispatch (UC&ED) model is employed to simulate power system operations. The economic costs of managing this system are presented using production costs, a traditional UC&ED metric that does not include any consideration of long-term fixed costs. ERGIS simulated one year of power system operations to understand regional and sub-hourly impacts of wind and PV by developing a comprehensive UC&ED model of the EI. In the analysis, it is shown that, under the study assumptions, generation from approximately 400 GW of combined wind and PV capacity can be balanced on the transmission system at a 5-minute level. In order to address the significant computational burdens associated with a model of this detail we apply novel computing techniques to dramatically reduce simulation solve time while simultaneously increasing the resolution and fidelity of the analysis. Our results also indicate that high penetrations of wind and PV (collectively variable generation (VG)), significantly impact the operation of traditional generating resources and cause these resources to be used less frequently and operate across a broader output range because wind and PV have lower operating costs and variable output levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Simulation of Ternary Pumped Storage Hydropower for Power System Studies

As the deployment of wind and solar energy increases in the United States, energy storage (ES) will play an important role in future electric power grids. To help manage the variability from high penetration levels of renewable generation, ES can provide promising power/energy demand to coordinate with renewables generation, as a virtual power plant (VPP). There is an industry need for the capability in power system studies to model ternary pumped storage hydropower (T-PSH) that offers increased system benefits. This paper presents a comprehensive vendor-neutral dynamic model of T-PSH in GE's commercial software positive sequence load flow (PSLF). A new governor model is developed with detailed gate valve modeling and a shared-penstock function. Specifically, this model is designed to simulate the seamless transition among three operation modes: generation mode, pumping mode, and hydraulic short-circuit mode. The developed T-PSH model has been tested and validated on a 10-bus test system. A comparison study of T-PSH to conventional pumped storage hydropower has also been conducted on the Western Interconnection system.

13 HYDRO ENERGY↗

Influence of prepulse plasma formation on neutron production from the laser-target interaction

The interaction of an intense ultrashort pulse laser with a planar uniform target was studied with a two-dimensional relativistic electromagnetic particle-in-cell method to determine the acceleration of deuterons and production of neutrons. A Au-CD{sub 2} double-layer planar target with thickness of {approx}1 {mu}m and a preplasma of variable length was used to generate high-energy deuterons as a precursor for neutron production. The deuteron energy and angular distributions and the neutron production from D(d,n)-{sup 3}He nuclear fusion reactions were studied as a function of the preplasma scale length and target thickness. For very thin (submicron) targets the preplasma increases the neutron yield only marginally, but for realistic targets with thickness of a few microns the preplasma enhances the neutron yield by two orders of magnitude. Both the average deuteron energy and neutron yield peak at an optimum preplasma scale length L{sub p}{sup opt}{approx_equal}1/k{sub 0} (k{sub 0} laser wave vector), which is of the order of one inverse laser wave vector.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coordinated Scheduling for Interdependent Electric Power and Natural Gas Infrastructures

The extensive installation of gas-fired power plants in many parts of the world has led electric systems to depend heavily on reliable gas supplies. The use of gas-fired generators for peak load and reserve provision causes high intraday variability in withdrawals from high-pressure gas transmission systems. Such variability can lead to gas price fluctuations and supply disruptions that affect electric generator dispatch, electricity prices, and threaten the security of power systems and gas pipelines. These infrastructures function on vastly different spatio-temporal scales, which prevents current practices for separate operations and market clearing from being coordinated. Here in this article, we apply new techniques for control of dynamic gas flows on pipeline networks to examine day-ahead scheduling of electric generator dispatch and gas compressor operation for different levels of integration, spanning from separate forecasting, and simulation to combined optimal control. We formulate multiple coordination scenarios and develop tractable physically accurate computational implementations. These scenarios are compared using an integrated model of test networks for power and gas systems with 24 nodes and 24 pipes, respectively, which are coupled through gas-fired generators. The analysis quantifies the economic efficiency and security benefits of gas-electric coordination and dynamic gas system operation.

03 NATURAL GAS↗

Workshop Summary: Bridging the Gap Between Atmospheric Science and Grid Integration

The need for dedicated, accurate, expertly curated weather data is increasingly important as the share of variable renewable energy increases on the power system. Projections for futures with very high (50+% annual energy) shares of variable generation require ongoing assessment of data requirements from industry stakeholders in their power system operation and planning contexts. In March 2024, NREL organized a workshop entitled "Bridging the Gap Between Atmospheric Science and Grid Integration Workshop", which brought atmospheric scientists and power system experts together to refine the requirements of atmospheric datasets for grid integration, and to describe a holistic approach to creating new and regularly updated national scale wind datasets for power system planning and operations. The results of this workshop are being used to inform the near-term development and a longer-term strategy for DOE to produce relevant wind resource datasets and inform wider use of wind/solar/load data sets in power system planning. This presentation provides an overview of a preworkshop survey, an assessment of current state of the art of national-scale datasets for wind resource assessment and grid integration, insights on appropriate uses of the WTK-LED, power system perspectives on data needs, as well as recommended next steps as discussed in the workshop and how these steps support longer-term strategies.

17 WIND ENERGY↗