Search NASA⌕ Search

SEARCH · Search NASA

Results for “home heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Nondestructive neutron imaging diagnosis of acidic gas reduction catalyst after 400-Hour operation in natural gas furnace

Residential natural gas furnaces are the primary space-heating devices in US homes, leading to substantial environmental impact caused by the acidic components in the furnace combustion gases. Here, to experimentally demonstrate acidic gas reduction in a furnace, a monolithic catalyst was fabricated and was called the AGR. A commercially-available condensing furnace was retrofitted with the AGR, and a 400-hour reliability and durability test was conducted. The results showed that the AGR significantly reduced acidic gases in the flue gas and produced condensate with neutral pH. Challenges were also revealed: inappropriate condensate drainage caused incomplete combustion and amorphous carbon deposits. To nondestructively survey the internal state of the AGR, neutron computed tomography (NCT) was employed to produce spatially resolved 2D and 3D representations of the 2-L, aged AGR component. The NCT results confirm the integrity of the AGR component, which consists of two blocks, without deformation or damage to AGR channels. The distribution of the particle accumulation in the middle of the top block was visibly heavier than the entrance and exit of the top block. The representative cross-section views revealed significant aggregation in the central region but not at the rim. The spatially resolved details provide in-depth diagnosis, evaluation, and understanding of the AGR. The insights can enable new AGR designs that realize a uniform and self-cleaning flow pattern, alleviate significant particle aggregation, and thus enhance AGR-enabled furnace performance. The neutron imaging method demonstrates the good potential that can diagnose faults and improve the design, optimization, and production processes of novel catalysts and other components or systems with heavy metal shell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Smart Vent System (SYSM 562 Final Project_Guest and Fleurantin)

Current residential air conditioning (AC) and heating units do a decent job at providing overall cooling/heating to a household. However, they usually fall short on accurately controlling which rooms to be heated and cooled. Most homes also require you to manually open or close a vent which can be very inconvenient if in a hard-to-reach area. There is a need for a system capable of automatically measuring and maintaining the thermal environment of each room throughout a house to meet a user’s preferences.

42 ENGINEERING↗

An analytical investigation of the performance of solar collectors as nighttime heat radiators in airconditioning cycles

It was found that if the upper and lower ends of a collector were opened, large free convention currents may be set up between the collector surface and the cover glass(es) which can result in appreciable heat rejection. If the collector is so designed that both plates surfaces are exposed to convection currents when the upper and lower ends of the collector enclosure are opened, the heat rejection rate is 300 watts sq m when the plate is 13 C above ambient. This is sufficient to permit a collector array designed to provide 100 percent of the heating needs of a home to reject the accumulated daily air conditioning load during the course of a summer night. This also permits the overall energy requirements for cooling to be reduced by at least 15 percent and shift the load on the utility entirely to the nighttime hours.

Jones, C. B.↗

Improved Regenerative Sorbent-Compressor Refrigerator

Conceptual regenerative sorbent-compressor refrigerator attains regeneration efficiency and, therefore, overall power efficiency and performance greater than conventional refrigerators. Includes two fluid loops. In one, CH2FCF3 (R134a) ciculates by physical adsorption and desorption in four activated-charcoal sorption compressors. In other, liquid or gas coolant circulated by pump. Wave of regenerative heating and cooling propagates cyclically like peristatic wave among sorption compressors and associated heat exchangers. Powered by electricity, oil, gas, solar heat, or waste heat. Used as air conditioners, refrigerators, and heat pumps in industrial, home, and automotive applications.

Jones, Jack A.↗

NCSU Industrial Assessment Center

Renewable energy technologies are becoming more attractive and gaining more attention as the world becomes increasingly aware of the negative impacts of global warming and greenhouse gas (GHG) emissions. Two such emerging technologies are geothermal heat pumps (GHP) and solar thermal heating which can be used for heating and cooling of buildings. GHP systems are a well-studied technology that have been proven to be more efficient than traditional air-source heat pumps for space conditioning of buildings. Solar thermal heating has become more common as a way to heat domestic hot water (DHW) in homes, but the two technologies are not often combined. This study presents the findings of combining an open-loop GHP with 100 ft2 of flat plate solar thermal panels and a 5,655-gallon sensible water storage tank for space heating and DHW heating needs of a residential home in Bozeman, MT, USA. The goal of this system was to use energy from the solar panels and storage tank first to decrease pumping energy from the GHP well. The open loop system was designed to be a backup system to the solar thermal panels and sensible storage tank. An actual home was modeled to determine potential energy and cost savings of such a system compared to a traditional propane boiler. Then, a case study was performed on the installed system from January to June 2021. Results obtained from April 2nd to June 5th, 2021 indicated that the combination system supplied all necessary heat, and that heat was supplied from the thermal storage tank 55% of the time. This represents a savings of 330 kWh of energy and $36 compared to operating just the open loop geothermal system. From April 2nd to June 5th the combination system consumed a total of 2,510 kWh of energy and cost $274 to operate. Based on data obtained, there is significant potential for energy savings compared to a propane boiler, however only small potential for cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Validation of a Co-Optimized, Smart Hybrid Heat Pump Control

This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Hot Water Heater

The solar panels pictured below, mounted on a Moscow, Idaho home, are part of a domestic hot water heating system capable of providing up to 100 percent of home or small business hot water needs. Produced by Lennox Industries Inc., Marshalltown, Iowa, the panels are commercial versions of a collector co-developed by NASA. In an effort to conserve energy, NASA has installed solar collectors at a number of its own facilities and is conducting research to develop the most efficient systems. Lewis Research Center teamed with Honeywell Inc., Minneapolis, Minnesota to develop the flat plate collector shown. Key to the collector's efficiency is black chrome coating on the plate developed for use on spacecraft solar cells, the coating prevents sun heat from "reradiating," or escaping outward. The design proved the most effective heat absorber among 23 different types of collectors evaluated in a Lewis test program. The Lennox solar domestic hot water heating system has three main components: the array of collectors, a "solar module" (blue unit pictured) and a conventional water heater. A fluid-ethylene glycol and water-is circulated through the collectors to absorb solar heat. The fluid is then piped to a double-walled jacket around a water tank within the solar module.

Source record↗

Pushing Green: Leveraging Home Energy Score to Promote Deep-Energy Retrofits in Portland, Oregon

In the United States, 39% of total energy is consumed by the building sector, 20% of which is attributed to residential buildings. Older homes, built before 1992 when the U.S. Department of Energy’s (DOE) Building Energy Codes Program was established, represent approximately 68% of residential building stock in the country and often have significant air leakage, inadequate insulation and inefficient heating & cooling systems. These older homes have long been the elephant in the room: how can programs effectively increase efficiency in all of the homes in need? Developed by DOE, the Home Energy Score was established to provide homeowners, buyers, and renters a comparable score measuring a home's energy use. Much like the MPG rating of automobiles, the Home Energy Score provides an overview of a residential building’s energy efficiency. In 2016, the City of Portland passed an ordinance requiring all residential properties to receive a Home Energy Score before being listed for sale, a mandate that was implemented January 1, 2018. Since 2018, more than 22,000 homes throughout the Portland Metro area have received Home Energy Scores (amounting to over 10% of Portland's single-family homes). This paper explores the sample of Home Energy Scores throughout Portland, including at the neighborhood level, identifies trends in efficiency measures, describes how the data has been used to date and proposes ways program administrators can use the Home Energy Score to increase the impact of energy efficiency programs on a city-scale.

Antonopoulos, Chrissi A.↗

Evaluation of Envelope Energy in a High-Performance Manufactured Home in California

There are important applications for a robust energy model for new construction manufactured homes that can characterize the individual performance of the opaque wall and ceiling components of the building envelope. The efficacy of different insulation materials can be assessed with the confidence that modeled performance will closely predict installed performance. This study uses careful calibration of a standard energy model with a short-term co-heating test in an installed manufactured home to de-aggregate the contributions of planar wall sections from overall building envelope thermal resistance. The methodology takes into account thermal mass effects, solar gains, and physical adjustments to the structure to achieve successful calibration and to inform adjustments to the test procedure for future study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Privacy Preserving Model-Free Optimization and Control Framework for Demand Response from Residential Thermal Loads

We consider the problem of optimizing the cost of procuring electricity for a large collection of homes managed by a load serving entity, by pre-cooling or pre-heating the thermal inertial loads in the homes to avoid procuring power during periods of peak electricity pricing. We would like to accomplish this objective in a completely privacy-preserving and model-free manner, that is, without direct access to the state variables (temperatures or power consumption) or the dynamical models (thermal characteristics) of individual homes, while guaranteeing personal comfort constraints of the consumers. We propose a two-stage optimization and control framework to address this problem. In the first stage, we use a long short-term memory (LSTM) network to predict hourly electricity prices, based on historical pricing data and weather forecasts. Given the hourly price forecast and thermal models of the homes, the problem of designing an optimal power consumption trajectory that minimizes the total electricity procurement cost for the collection of thermal loads can be formulated as a large-scale integer program (with millions of variables) due to the on-off cyclical dynamics of such loads. We provide a simple heuristic relaxation to make this large-scale optimization problem model-free and computationally tractable. In the second stage, we translate the results of this optimization problem into distributed open-loop control laws that can be implemented at individual homes without measuring or estimating their state variables, while simultaneously ensuring consumer comfort constraints. We demonstrate the performance of this approach on a large-scale test case comprising of 500 homes in the Houston area and benchmark its performance against a direct model-based optimization and control solution.

Sivaranjani, S.↗

Energy Saver Guide: Tips on Saving Money and Energy at Home

Follow the simple tips in the Energy Saver guide to make your home more comfortable and easier to heat and cool--while you save money. This guide shows you how easy it is to cut your energy use at home and also on the road.

Guide, Tips, Money, Home, Saver, Consumer, Energy ↗

Wind power systems for individual applications

A small windpower system is described which is suitable for electrifying a house. The self-contained unit consists of a two kilowatt wind driven generator, a set of 19 storage batteries, a small dc to ac inverter, and a gasoline generator for use as an emergency backup system in case of prolonged calm periods. Cost effectiveness of the electricity generated by this windmill system comes out to about 15 cents per kilowatt hour - assuming a 10 year life for the batteries and a 20 year life for the other components. Some other small windpower systems are also described, and it is shown that a windpowered generator in the 15- to 25-kilowatt output range coupled to a direct heated water storage system is able to heat a typical New England home.

Clews, H. M.↗

Aerial thermal scanner data for monitoring rooftop temperatures

Four Nebraska communities and one South Dakota community were surveyed. Thermal scanner data were converted to a film format and the resultant imagery was successfully employed to monitor rooftop temperatures. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

Bjorkland, J.↗

A report on the use of thermal scanner data in an operational program for monitoring apparent rooftop temperatures

CENGAS, a division of Central Telephone and Utilities Corporation in cooperation with the Remote Sensing Institute, South Dakota State University, is using airborne thermal scanner data to monitor relative rooftop temperatures. Four Nebraska communities and one South Dakota community were surveyed by the Remote Sensing Institute for CENGAS. Thermal scanner data were converted to a film format and the resultant imagery has been successfully employed by CENGAS. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

Bjorklund, J.↗

Evaluation of Thin Triple-Pane Windows in the PNNL Lab Homes

In recent years, improvements in glass manufacturing have allowed the production of thin triple-pane windows, which are manufactured with a thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy is sponsoring laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. To examine the performance of thin triple-pane windows, the Pacific Northwest National Laboratory (PNNL) evaluated the windows at the PNNL Lab Homes, a matched pair of homes located on PNNL’s campus in Richland, Washington. In this study, one Lab Home contained a complete set of nine thin triple-pane windows, while the other Lab Home contained baseline double-pane windows. The Lab Homes experiments demonstrated significant that replacing clear glass double-pane windows with thin triple-pane windows provided year-round energy savings and reduced peak demand both in the heating and cooling seasons. The Lab Homes experiments also validated other performance benefits of the thin triple-pane windows including reduced condensation potential, more even temperatures throughout the home and near the windows, and reduced sound attenuation through the windows, leaving the home quieter and more comfortable for the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time MPC for Residential Building Water Heater Systems to Support the Electric Grid

The world of IoT (internet of things) is spawning new control options and decision making that has not been available before. This is providing a wealth of opportunities for transactive type controls and systems that can negotiate for a common goal. This paper discusses a transactive residential neighborhood with optimization at the home level utilizing a system of agents. The real-time optimization utilizes information and modeling to optimize heat pump water heater operation in occupied homes. Data is presented showing the performance of the optimization and conclusions are drawn on next steps for development.

Starke, Michael↗