Search NASA⌕ Search

SEARCH · Search NASA

Results for “hot”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Observations of the Hot Horizontal Branch Stars in the Metal-Rich Bulge Globular Cluster NGC 6388

The metal-rich bulge globular cluster NGC 6388 shows a distinct blue horizontal-branch tail in its colour-magnitude diagram (Rich et al. 1997) and is thus a strong case of the well-known 2nd Parameter Problem. In addition, its horizontal branch (HB) shows an upward tilt toward bluer colours, which cannot be explained by canonical evolutionary models. Several non-canonical scenarios have been proposed to explain these puzzling observations. In order to test the predictions of these scenarios, we have obtained medium resolution spectra to determine the atmospheric parameters of a sample of the blue HB stars in NGC 6388.Using the medium resolution spectra, we determine effective temperatures, surface gravities and helium abundances by fitting the observed Balmer and helium lines with appropriate theoretical stellar spectra. As we know the distance to the cluster, we can verify our results by determining masses for the stars. During the data reduction we took special care to correctly subtract the background, which is dominated by the overlapping spectra of cool stars. The cool blue tail stars in our sample with T(sub eff) approximately 10000 K have lower than canonical surface gravities, suggesting that these stars are, on average, approximately equal to 0.4 mag brighter than canonical HB stars in agreement with the observed upward slope of the HB in NGC 6388. Moreover, the mean mass of these stars agrees well with theoretical predictions. In contrast, the hot blue tail stars in our sample with T(sub eff) greater than or equal to 12000 K show significantly lower surface gravities than predicted by any scenario, which can reproduce the photometric observations. Their masses are also too low by about a factor of 2 compared to theoretical predictions. The physical parameters of the blue HB stars at about 10,000 K support the helium pollution scenario. The low gravities and masses of the hot blue tail stars, however, are probably caused by problems with the data reduction, most likely due to remaining background light in the spectra, which would affect the fainter hot blue tail stars much more strongly than the brighter cool blue tail stars. Our study of the hot blue tail stars in NGC 6388 illustrates the obstacles which are encountered when attempting to determine the atmospheric parameters of hot HB stars in very crowded fields using ground-based observations. We discuss these obstacles and offer possible solutions for future projects.

Moehler, S.↗

The Hot Horizontal-Branch Stars in omega Centauri

Context. UV observations of some massive globular clusters have revealed a significant population of stars hotter and fainter than the hot end of the horizontal branch (HB), the so-called blue hook stars. This feature might be explained either by the late hot flasher scenario where stars experience the helium flash while on the white dwarf cooling curve or by the progeny of the helium-enriched sub-population recently postulated to exist in some clusters. Previous spectroscopic analyses of blue hook stars in co Cen and NGC 2808 support the late hot flasher scenario, but the stars contain much less helium than expected and the predicted C, N enrichment could not be verified. Aims. We compare observed effective temperatures, surface gravities, helium abundances, and carbon line strengths (where detectable) of our targets stars to the predictions of the two scenarios. Methods. Moderately high resolution spectra of hot HB stars in the globular cluster omega-Cen were analysed for radial velocity variations, atmospheric parameters and abundances using LTE and non-LTE model atmospheres. Results. We find no evidence for close binaries among our target stars. All stars below 30 000 K are helium-poor and very similar to HB stars observed in that temperature range in other globular clusters. In the temperature range 30000 K to 50000 K we find that 28% of our stars are helium-poor (log ((sup n)He/(sup n )H)< - 1.6), while 72% have roughly solar or super-solar helium abundance (log ((sup n)He/(sup n )H) >/= -1.5). We also find carbon enrichment strongly correlated with helium enrichment, with a maximum carbon enrichment of 3% by mass. Conclusions. The strong carbon enrichment in tandem with helium enrichment is predicted by the late hot flasher scenario, but not by the helium-enrichment scenario. We conclude that the helium-rich HB stars in omega-Cen cannot be explained solely by the helium-enrichment scenario invoked to explain the blue main sequence.

Moehler, S.↗

Hot Films on Ceramic Substrates for Measuring Skin Friction

Hot-film sensors, consisting of a metallic film on an electrically nonconductive substrate, have been used to measure skin friction as far back as 1931. A hot film is maintained at an elevated temperature relative to the local flow by passing an electrical current through it. The power required to maintain the specified temperature depends on the rate at which heat is transferred to the flow. The heat transfer rate correlates to the velocity gradient at the surface, and hence, with skin friction. The hot-film skin friction measurement method is most thoroughly developed for steady-state conditions, but additional issues arise under transient conditions. Fabricating hot-film substrates using low-thermal-conductivity ceramics can offer advantages over traditional quartz or polyester-film substrates. First, a low conductivity substrate increases the fraction of heat convected away by the fluid, thus increasing sensitivity to changes in flow conditions. Furthermore, the two-part, composite nature of the substrate allows the installation of thermocouple junctions just below the hot film, which can provide an estimate of the conduction heat loss.

Noffz, Greg↗

Hot-Fire Testing of a 1N AF-M315E Thruster

This hot-fire test continues NASA investigation of green propellant technologies for future missions. To show the potential for green propellants to replace some hydrazine systems in future spacecraft, NASA Marshall Space Flight Center (MSFC) is continuing to embark on hot-fire test campaigns with various green propellant blends. NASA completed a hot-fire test of a 1N AF-M315E monopropellant thruster at the Marshall Space Flight Center in the small altitude test stand located in building 4205. The thruster is a ground test article used for basic performance determination and catalyst studies. The purpose of the hot-fire testing was for performance determination of a 1N size thruster and form a baseline from which to study catalyst performance and life with follow-on testing to be conducted at a later date. The thruster performed as expected. The result of the hot-fire testing are presented in this paper and presentation.

Burnside, Christopher G.↗

Optimization of a Multifunctional Hot Structure Aeroshell for Mars Entry

Vehicle size and weight are driving cost factors in sending vehicles into space because the cost of launch is directly related to the payload mass being delivered. Vehicle size and weight have a larger impact on deep- space missions compared to sending a payload to low Earth orbit due to the extra fuel and supplies required to complete the longer duration mission. One area of study for possible vehicle volume or weight reduction is the thermal protection system (TPS) of a vehicle. Hot structures have been proposed as a TPS concept which can carry both primary structural loads and thermal loads. The use of hot structures on a Mars entry vehicle may be feasible and have potential volume and weight savings over the current state of the art ablative TPS technology. A preliminary trade study was performed on a mid lift-to-drag aeroshell Mars entry concept vehicle; comparing the weight and skin thickness of a vehicle using ablative TPS with a vehicle using hot structures. Independent thermal and structural analyses were performed to determine the minimum mass designs. The goal of this study was to determine if the use of hot structures was feasible and had potential for significant vehicle volume and weight savings over the current state of the art. This trade study found that use of a hot structures leads to a feasible alternative to ablative TPS technology, with potential 53% weight and 22% thickness (volume) saving benefits that could enable future missions.

Langston, Sarah L.↗

Ceramic Matrix Composite (CMC) Thermal Protection Systems (TPS) and Hot Structures for Hypersonic Vehicles

Thermal protection systems (TPS) and hot structures are required for a range of hypersonic vehicles ranging from ballistic reentry to hypersonic cruise vehicles, both within Earth’s atmosphere and non-Earth atmospheres. The focus of this presentation is on air breathing hypersonic vehicles in the Earth's atmosphere. This includes single-stage to orbit (SSTO), two-stage to orbit (TSTO) accelerators, access to space vehicles, and hypersonic cruise vehicles. The presentation will start with a brief discussion of aerodynamic heating and thermal management techniques to address the high heating, followed by an overview of TPS for rocket-launched and air-breathing vehicles. The argument is presented that as we move from rocket-based vehicles to air-breathing vehicles, we need to move away from the “insulated airplane” approach used on the Space Shuttle Orbiter to a wide range of TPS and hot structure approaches. The primary portion of the presentation will discuss issues and design options for CMC TPS and hot structure components, including leading edges, acreage TPS, and control surfaces. The current state-of-the-art will be briefly discussed for some of the components. The two primary technical challenges impacting the use of CMC TPS and hot structures for hypersonic vehicles are environmental durability and fabrication, and will be discussed briefly.

Thermal Protection Systems↗

Ceramic Matrix Composite (CMC) Thermal Protection Systems (TPS) and Hot Structures for Hypersonic Vehicles

Thermal protection systems (TPS) and hot structures are required for a range of hypersonic vehicles ranging from ballistic reentry to hypersonic cruise vehicles, both within Earth’s atmosphere and non-Earth atmospheres. The focus of this presentation is on air breathing hypersonic vehicles in the Earth's atmosphere. This includes single-stage to orbit (SSTO), two-stage to orbit (TSTO) accelerators, access to space vehicles, and hypersonic cruise vehicles. The presentation will start with a brief discussion of aerodynamic heating and thermal management techniques to address the high heating, followed by an overview of TPS for rocket-launched and air-breathing vehicles. The argument is presented that as we move from rocket-based vehicles to air-breathing vehicles, we need to move away from the “insulated airplane” approach used on the Space Shuttle Orbiter to a wide range of TPS and hot structure approaches. The primary portion of the presentation will discuss issues and design options for CMC TPS and hot structure components, including leading edges, acreage TPS, and control surfaces. The current state-of-the-art will be briefly discussed for some of the components. The two primary technical challenges impacting the use of CMC TPS and hot structures for hypersonic vehicles are environmental durability and fabrication, and will be discussed briefly.

Thermal Protection Systems, hot structure↗

Fluid flow analysis of a hot-core hypersonic wind-tunnel nozzle concept

A hypersonic-wind-tunnel nozzle concept which incorporates a hot-core flow surrounded by an annular flow of cold air offers a promising technique for maximizing the model size while minimizing the power required to heat the test core. This capability becomes especially important when providing the true-temperature duplication needed for hypersonic propulsion testing. Several two-dimensional wind-tunnel nozzle configurations that are designed according to this concept are analyzed by using recently developed analytical techniques for prediction of the boundary-layer growth and the mixing between the hot and cold coaxial supersonic airflows. The analyses indicate that introduction of the cold annular flow near the throat results in an unacceptable test core for the nozzle size and stagnation conditions considered because of both mixing and condensation effects. Use of a half-nozzle with a ramp on the flat portion does not appear promising because of the thick boundary layer associated with the extra length. However, the analyses indicate that if the cold annular flow is introduced at the exit of a full two-dimensional nozzle, an acceptable test core will be produced. Predictions of the mixing between the hot and cold supersonic streams for this configuration show that mixing effects from the cold flow do not appreciably penetrate into the hot core for the large downstream distances of interest.

Anders, J. B.↗

Hot corrosion of TD nickel and TD nickel chromium in a high velocity gas stream.

Results of cyclical tests of TD nickel (2% thoria-dispersed nickel) and TD nickel chromium (2% thoria-dispersed nickel-20% chromium alloy) 1.5 mm (60 mil) sheet specimens for susceptibility to hot corrosion in a Mach 0.5 gas stream of Jet A-1 fuel combustion products containing 2 ppm sea salt. Tests as long as 500 one-hour cycles between room temperature and specimen hot zone temperatures of 899 C (1650 F), 982 C (1800 F), and 1149 C (2100 F) were performed. Evidence of hot corrosion was found for both materials in the 899 C (1650 F) and 982 C (1800 F) tests, but not at 1149 C (2100 F). It was concluded that because of high metal thickness losses neither alloy in sheet form is suitable for long-time engine application in a hot corrosion environment at temperatures of 982 C (1800 F) or above.

Sanders, W. A.↗

Hot hardness characteristics of ausformed AISI M-50, Matrix 2, WD-65, modified AISI 440-C, and Super Nitralloy

Short-term hot hardness studies were performed with ausformed AISI M-50, Matrix 2, WD-65, modified AISI 440-C (14-4-1) and case hardened Super Nitralloy. Hardness levels of each material were measured at elevated temperatures in an electric furnace with a low oxygen environment. Test temperatures ranged from 294 to 877 K. The hot hardness characteristics of the ausformed AISI-M-50, Matrix 2 WD-65, and modified AISI 440-C were the same as those determined for high-speed tool steels. Hot hardness for these steels can be predicted within one point Rockwell C. The hot hardness characteristics of both the case and core of Super Nitralloy were superior to AISI 52100 but inferior to the high-speed tool steels. The short-term Rockwell C hardness at temperature for the Super Nitralloy material between 294 and 769 K can be predicted within one point Rockwell C hardness.

Chevalier, J. L.↗

Hot spot and trench volcano separations

It is suggested that the distribution of separations between trench volcanos located along subduction zones reflects the depth of partial melting, and that the separation distribution for hot spot volcanoes near spreading centers provides a measure of the depth of mantle convection cells. It is further proposed that the lateral dimensions of mantle convection cells are also represented by the hot-spot separations (rather than by ridge-trench distances) and that a break in the distribution of hot spot separations at 3000 km is evidence for both whole mantle convection and a deep thermal plume origin of hot spots.

Lingenfelter, R. E.↗

Hot wire anemometry in transonic flow

The use of hot-wire anemometry for obtaining fluctuating data in transonic flows has been evaluated. From hot-wire heat loss correlations based on previous transonic data, the sensitivity coefficients for velocity, density, and total temperature fluctuations have been calculated for a wide range of test conditions and sensor parameters. For sensor Reynolds numbers greater than 20 and high sensor overheat ratios, the velocity sensitivity remains independent of Mach number and equal to the density sensitivity. These conclusions were verified by comparisons of predicted sensitivities with those from recent direct calibrations in transonic flows. Based on these results, techniques are presented to obtain meaningful measurements of fluctuating velocity, density, and Reynolds shear stress using hot-wire and hot-film anemometers. Examples of these measurements are presented for two transonic boundary layers.

Horstman, C. C.↗

Hot-wire anemometry in transonic flow

The use of hot-wire anemometry for obtaining fluctuating data in transonic flows has been evaluated. From hot-wire heat loss correlations based on previous transonic data, the sensitivity coefficients for velocity, density, and total temperature fluctuations have been calculated for a wide range of test conditions and sensor parameters. For sensor Reynolds number greater than 20 and high sensor overheat ratios, the velocity sensitivity remains independent of Mach number and equal to the density sensitivity. These conditions were verified by comparisons of predicted sensitivities with those from recent direct calibrations in transonic flows. Based on these results, techniques are presented to obtain meaningful measurements of fluctuating velocity, density, and Reynolds shear stress using hot-wire and hot-film anemometers. Example of these measurements are presented for two transonic boundary layers.

Horstman, C. C.↗

Hot corrosion studies of four nickel-base superalloys - B-1900, NASA-TRW VIA, 713C and IN738

The susceptibility to hot corrosion of four nickel-base superalloys has been studied at 900 and 1000 C in one atmosphere of slowly flowing oxygen. Hot corrosion was induced by coating the samples with known doses of Na2SO4 and oxidizing the coated samples isothermally on a sensitive microbalance. In order of decending susceptibility to hot corrosion, these alloys were ranked: B-1900, 713C, NASA-TRW VIA, IN738. This order corresponds to the order of decreasing molybdenum content of the alloys. Chemical evidence for B-1900 indicates that hot corrosion is instigated by acid fluxing of the protective Al2O3 coating by MoO3.

Fryburg, G. C.↗

Consolidation of Si3N4 by hot isostatic pressing

Silicon nitride (Si3N4) is being considered for gas turbine engine applications because present-day metallic alloys are rapidly approaching the limits of their temperature capabilities. The present investigation was undertaken to determine the feasibility of producing a sound, dense Si3N4 body without additives, using conventional gas hot-isostatic-pressing techniques and an uncommon hydraulic hot-isostatic-pressing technique. These two hot-isostatic-pressing (HIP) techniques produce much higher pressure (275-413 MN/sq m) than conventional hot-pressing techniques and have the potential of producing large bodies of desirable shapes. Evaluation was based on density measurement, microscopic examination, both optical and electron, and X-ray diffraction analysis.

Yeh, H. C.↗

A dual-amplifier hot-wire anemometer

The conceptual design of a dual-amplifier constant-temperature hot-wire anemometer is described. This hot-wire anemometer consists of three basic independent modules: a Wheatstone bridge in which the hot wire is one of its arms, an error-correction amplifier, and a voltage-controlled current source. The last two modules constitute the feedback network of this hot-wire anemometer. Thus the output voltage across the wire is a true function of the instantaneous changes in the wire resistance induced by the cooling effect of the flow. The dual-amplifier is capable of reaching relatively high frequency response through adequate selection of its active elements. Suitable gain of the error-correction amplifier and proper choice of the transfer function of the current source has yielded a frequency bandwidth up to 200 kHz.

Sadeh, W. Z.↗

Solar hot water system installed at Day's Lodge, Atlanta, Georgia

The solar energy hot water system installed in the Days Inns of America, Inc., Atlanta, Georgia is described. This system provides for 81 percent of the total hot water demand. There are two separate systems, each serving one building of the lodge (total of 65 suites). The entire system contains only potable city water. The 1024 square feet of Grumman Sunstream Model 332 liquid flat plate collectors and the outside piping drain whenever the collector plates approach freezing or when power is interrupted. Solar heated water from the two above ground cement lined steel tanks (1000 gallon tank) is drawn into the electric Domestic Hot Water (DHW) tanks as hot water is drawn. Electric resistance units in the DHW tanks top off the solar heated water, if needed, to reach thermostat setting.

Source record↗

Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corporation, Columbus, Ohio

The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.

Source record↗