Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydrogen detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Energy-selective SESD imaging utilizing a CMA

A particularly simple conversion of a scanning Auger system for ESD ion energy distributions and scanning ESD has been developed. This approach combines the advantages of the small spot-size electron guns and mapping systems developed for SAM with the capability of ESD for the detection of hydrogen. Our intended use for the device is detection and mapping of surface concentrations of hydrogen on metals. The characteristics of SESD are illustrated with the preliminary results of an investigation into the ESD properties of hydrogenic adsorbates on Nb. It is shown that the ESDIED exhibit distinct differences indicative of the surface preparation, and that the ESD ion angular distributions have an effect on the observed contrast relationships in SESD.

Larson, L. A.↗

The development of hydrogen sensor technology at NASA Lewis Research Center

The detection of hydrogen leaks in aerospace applications, especially those involving hydrogen fuel propulsion systems, is of extreme importance for reasons of reliability, safety, and economy. Motivated by leaks occurring in liquid hydrogen lines supplying the main engine of the Space Shuttle, NASA Lewis has initiated a program to develop point-contact hydrogen sensors which address the needs of aerospace applications. Several different approaches are being explored. They include the fabrication of PdAg Schottky diode structures, the characterization of PdCr as a hydrogen sensitive alloy, and the use of SiC as a semiconductor for hydrogen sensors. This paper discusses the motivation behind and present status of each of the major components of the NASA LeRC hydrogen sensor program.

Hunter, Gary W.↗

Imaging Hydrogen Leaks With Raman Scattering

Proposed spectral imaging system used to detect leaking hydrogen from distance of 100 ft or more. Video cameras form images of leaking hydrogen by use of Raman scattering of laser beam from hydrogen. By indicating potentially explosive concentrations of hydrogen in air, system contributes to safety at facilities producing and handling hydrogen, such as fueling stations for hydrogen-burning automobiles of near future.

Mcdermid, Iain S.↗

Passive, Direct-Read Monitoring System for Selective Detection and Quantification of Hydrogen Chloride

Monitoring the exposure of an employee to hydrogen chloride or hydrochloric acid in the presence of other acids has been a challenge to the industrial hygiene community. The capability of a device to differentiate the levels of acid vapors would allow for more accurate determinations of exposure and therefore improved occupational health. In this work, a selective direct-read colorimetric badge system was validated for Short Term Exposure Limit (STEL) monitoring of hydrogen chloride. The passive colorimetric badge system consists of a direct reading badge and a color scale. The badge has a coated indicator layer with a diffusive resistance in the shape of an exclamation mark. An exclamation mark will appear if hydrogen chloride is present in the atmosphere at concentrations at or above 2.0 ppm. By using the color scale, the intensity of the color formed on the badge can be further quantified up to 25 ppm. The system was validated according to a protocol based on the NIOSH Protocol for the Evaluation of Passive Monitors. The badge was exposed to relative humidities ranging from 11% to 92%, temperatures ranging from 7 C to 400 C and air velocities ranging from 5 cm/sec to 170 cm/sec. All experiments were conducted in a laboratory vapor generation system. Hydrofluoric acid, nitric acid, sulfuric acid, chlorine, hydrogen sulfide and organic acids showed no effect on the performance of the hydrogen chloride monitoring system. The passive badge and color scale system exceeded the accuracy requirements as defined by NIOSH. At ambient conditions, the mean coefficient of variation was 10.86 and the mean bias was 1.3%. This data was presented previously at the American Industrial Hygiene Conference and Exposition in Toronto, Canada in June 1999.

Chapman, K. B.↗

Deuterium in comet C/1995 O1 (Hale-Bopp): detection of DCN

Deuterated hydrogen cyanide (DCN) was detected in a comet, C/1995 O1 (Hale-Bopp), with the use of the James Clerk Maxwell Telescope on Mauna Kea, Hawaii. The inferred deuterium/hydrogen (D/H) ratio in hydrogen cyanide (HCN) is (D/H)HCN = (2.3 +/- 0.4) x 10(-3). This ratio is higher than the D/H ratio found in cometary water and supports the interstellar origin of cometary ices. The observed values of D/H in water and HCN imply a kinetic temperature >/=30 +/- 10 K in the fragment of interstellar cloud that formed the solar system.

Non-NASA Center↗

Discovery of Interstellar Hydrogen Fluoride

We report the first detection of interstellar hydrogen fluoride. Using the Long Wavelength Spectrometer of the Infrared Space Observatory (ISO), we have detected the 121.6973 micron J = 2-1 line of HF in absorption toward the far-infrared continuum source Sagittarius B2. The detection is statistically significant at the 13 sigma level. On the basis of our model for the excitation of HF in Sgr B2, the observed line equivalent width of 1.0 nm implies a hydrogen fluoride abundance of about 3 x 10 (exp -10) relative to H, If the elemental abundance of fluorine in Sgr B2 is the same as that in the solar system, then HF accounts for about 2% of the total number of fluorine nuclei. We expect hydrogen fluoride to be the dominant reservoir of gas-phase fluorine in Sgr B2, because it is formed rapidly in exothermic reactions of atomic fluorine with either water or molecular hydrogen; thus, the measured HF abundance suggests a substantial depletion of fluorine onto dust grains. Similar conclusions regarding depletion have previously been reached for the case of chlorine in dense interstellar clouds. We also find evidence at a lower level of statistical significance (about 5 sigma) for an emission feature at the expected position of the 4(sub 32)-4(sub 23) 121.7219 micron line of water. The emission-line equivalent width of 0.5 mm for the water feature is consistent with the water abundance of 5 x 10(exp -6) relative to H, that has been inferred previously from observations of the hot core of Sgr B2.

Neufeld, David A.↗

Discovery of Interstellar Hydrogen Fluoride

We report the first detection of interstellar hydrogen fluoride. Using the Long Wavelength Spectrometer of the Infrared Space Observatory (ISO), we have detected the 121.6973 micron J = 2-1 line of HF in absorption toward the far-infrared continuum source Sagittarius B2. The detection is statistically significant at the 13 sigma level. On the basis of our model for the excitation of HF in Sgr B2, the observed line equivalent width of 1.0 nm implies a hydrogen fluoride abundance of approximately 3 x 10(exp -10) relative to H2. If the elemental abundance of fluorine in Sgr B2 is the same as that in the solar system, then HF accounts for approximately 2% of the total number of fluorine nuclei. We expect hydrogen fluoride to be the dominant reservoir of gas-phase fluorine in Sgr B2, because it is formed rapidly in exothermic reactions of atomic fluorine with either water or molecular hydrogen; thus, the measured HF abundance suggests a substantial depletion of fluorine onto dust grains. Similar conclusions regarding depletion have previously been reached for the case of chlorine in dense interstellar clouds. We also find evidence at a lower level of statistical significance (approximately 5 sigma) for an emission feature at the expected position of the 4(sub 32)-4(sub 23) 121.7219 micron line of water. The emission-line equivalent width of 0.5 nm for the water feature is consistent with the water abundance of 5 x 10(exp -6) relative to H2 that has been inferred previously from observations of the hot core of Sgr B2.

Neufeld, David A.↗

Micro-machined thin film hydrogen gas sensor, and method of making and using the same

A hydrogen sensor including a thin film sensor element formed, e.g., by metalorganic chemical vapor deposition (MOCVD) or physical vapor deposition (PVD), on a microhotplate structure. The thin film sensor element includes a film of a hydrogen-interactive metal film that reversibly interacts with hydrogen to provide a correspondingly altered response characteristic, such as optical transmissivity, electrical conductance, electrical resistance, electrical capacitance, magnetoresistance, photoconductivity, etc., relative to the response characteristic of the film in the absence of hydrogen. The hydrogen-interactive metal film may be overcoated with a thin film hydrogen-permeable barrier layer to protect the hydrogen-interactive film from deleterious interaction with non-hydrogen species. The hydrogen sensor of the invention may be usefully employed for the detection of hydrogen in an environment susceptible to the incursion or generation of hydrogen and may be conveniently configured as a hand-held apparatus.

DiMeo, Jr., Frank↗

Fabrication method for a room temperature hydrogen sensor

A sensor for selectively determining the presence and measuring the amount of hydrogen in the vicinity of the sensor. The sensor comprises a MEMS device coated with a nanostructured thin film of indium oxide doped tin oxide with an over layer of nanostructured barium cerate with platinum catalyst nanoparticles. Initial exposure to a UV light source, at room temperature, causes burning of organic residues present on the sensor surface and provides a clean surface for sensing hydrogen at room temperature. A giant room temperature hydrogen sensitivity is observed after making the UV source off. The hydrogen sensor of the invention can be usefully employed for the detection of hydrogen in an environment susceptible to the incursion or generation of hydrogen and may be conveniently used at room temperature.

Seal, Sudipta↗

Fiber-Optic Based Compact Gas Leak Detection System

A propellant leak detection system based on Raman scattering principles is introduced. The proposed system is flexible and versatile as the result of the use of optical fibers. It is shown that multiple species can be monitored simultaneously. In this paper oxygen, nitrogen, carbon monoxide, and hydrogen are detected and monitored. The current detection sensitivity for both hydrogen and carbon monoxide is 1% partial pressure at ambient conditions. The sensitivity for oxygen and nitrogen is 0.5% partial pressure. The response time to changes in species concentration is three minutes. This system can be used to monitor multiple species at several locations.

deGroot, Wim A.↗

Microfabricated Hydrogen Sensor Technology for Aerospace and Commercial Applications

Leaks on the Space Shuttle while on the Launch Pad have generated interest in hydrogen leak monitoring technology. An effective leak monitoring system requires reliable hydrogen sensors, hardware, and software to monitor the sensors. The system should process the sensor outputs and provide real-time leak monitoring information to the operator. This paper discusses the progress in developing such a complete leak monitoring system. Advanced microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC) and Gencorp Aerojet (Aerojet). Changes in the hydrogen concentrations are detected using a PdAg on silicon Schottky diode structure. Sensor temperature control is achieved with a temperature sensor and heater fabricated onto the sensor chip. Results of the characterization of these sensors are presented. These sensors can detect low concentrations of hydrogen in inert environments with high sensitivity and quick response time. Aerojet is developing the hardware and software for a multipoint leak monitoring system designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Work has commenced on integrating the NASA LeRC-CWRU hydrogen sensors with the Aerojet designed monitoring system. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. Possible commercialization of the system will also be discussed.

Hunter, Gary W.↗

Discovery of molecular hydrogen fluorescence in the diffuse interstellar medium

The first detection of molecular hydrogen fluorescence in the diffuse interstellar medium is reported. Using the Berkeley UVX Shuttle Spectrometer, H2 Lyman band fluorescence has been observed in four directions, each with high significance. Molecular hydrogen fluorescence is detected in all directions that have previously been found to contain significant CO emission. A simple equilibrium model has been developed that includes attenuation of the incident UV radiation field by H2 line and dust continuum absorption. Evidence is found that the gas in the CO emission portions of the clouds may be clumpy, with a filling factor less than 0.2 and an average density greater than 30/cu cm in most cases.

Martin, Christopher↗

Lunar neutron leakage fluxes as a function of composition and hydrogen content

Areas of the moon that might have enhanced concentrations of hydrogen are discussed. The fluxes of thermal, epithermal, and fast neutrons escaping from the lunar surface were calculated for eight different compositions and several hydrogen contents. These flux ratios depend on composition and are very sensitive to the hydrogen content. Their measurement using flight-proven techniques from lunar orbit should allow detection and identification of hydrogen residing in either permanently shaded cold traps near the lunar poles or mature regoliths. Knowledge of composition, especially of Fe and Ti, improves the thresholds for hydrogen detection and also could allow identification of Gd and Sm.

Feldman, W. C.↗

Microbial detection method based on sensing molecular hydrogen

An approach involving the measurement of hydrogen evolution by test organisms was used to detect and enumerate various members of the Enterobacteriaceae group. The experimental setup for measuring hydrogen evolution consisted of a test tube containing two electrodes plus broth and organisms. The test tube was kept in a water bath at a temperature of 35 C. It is pointed out that the hydrogen-sensing method, coupled with the pressure transducer technique reported by Wilkins (1974) could be used in various experiments in which gas production by microorganisms is being measured.

Wilkins, J. R.↗

Atomic hydrogen in planetary nebulae

The authors searched for neutral atomic hydrogen associated with 22 planetary nebulae and three evolved stars in the 21 cm line at the Arecibo Observatory. Objects whose radial velocities permitted discrimination from Galactic H I were chosen for observation. Hydrogen was detected in absorption from IC 4997. From the measurements new low limits are derived to the mass of atomic hydrogen associated with the undetected nebulae. Radio continuum observations were also made of several of the nebulae at 12.6 cm. The authors reexamine previous measurements of H I in planetary nebulae, and present the data on a consistent footing. The question of planetary nebula distances is considered at length. Finally, implications of the H I measurements for nebular evolution are discussed and it is suggested that atomic hydrogen seen in absorption was expelled from the progenitor star during the final 1000 yr prior to the onset of ionization.

Schneider, Stephen E.↗

Search for sulfur (H2S) on Jupiter at millimeter wavelengths

Jupiter was observed at two wavelengths near 1.4 mm in an attempt to detect gaseous hydrogen sulfide (H2S) or place new upper limits on its abundance on Jupiter's atmosphere. Although no H2S was detected, the first brightness temperature observations of Jupiter at 1.4 mm are reported with a spectral resolution of approximately 1 GHz using Mars as a calibration standard. The methodology and results of a laboratory experiment in which H2S absorption at 1.4 mm was measured in a simulated Jovian atmosphere. The results of laboratory measurements are applied to a radiative transfer model which is used to interpret the observations of Jupiter.

Joiner, Joanna↗