Search NASA⌕ Search

SEARCH · Search NASA

Results for “hyperspectral spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Simulation of Wake Vortex Radiometric Detection via Jet Exhaust Proxy

This paper describes an analysis of the potential of an airborne hyperspectral imaging IR instrument to infer wake vortices via turbine jet exhaust as a proxy. The goal was to determine the requirements for an imaging spectrometer or radiometer to effectively detect the exhaust plume, and by inference, the location of the wake vortices. The effort examines the gas spectroscopy of the various major constituents of turbine jet exhaust and their contributions to the modeled detectable radiance. Initially, a theoretical analysis of wake vortex proxy detection by thermal radiation was realized in a series of simulations. The first stage used the SLAB plume model to simulate turbine jet exhaust plume characteristics, including exhaust gas transport dynamics and concentrations. The second stage used these plume characteristics as input to the Line By Line Radiative Transfer Model (LBLRTM) to simulate responses from both an imaging IR hyperspectral spectrometer or radiometer. These numerical simulations generated thermal imagery that was compared with previously reported wake vortex temperature data. This research is a continuation of an effort to specify the requirements for an imaging IR spectrometer or radiometer to make wake vortex measurements. Results of the two-stage simulation will be reported, including instrument specifications for wake vortex thermal detection. These results will be compared with previously reported results for IR imaging spectrometer performance.

Daniels, Taumi S.↗

Spatially Resolved Raman Spectroscopy of Thin Carbon Interphase in SiC Ceramic Matrix Composites

A dedicated analysis method is presented to extract the Raman spectrum of an interphase layer thinner than the laser spot size. We focused on spatial correlations between the contrast of optical micrographs and Raman hyperspectral data to predict the constituents of the mixed spectra measured near the interphase. By employing a mapping step size of 0.1 μm, the Raman spectrum of approximately 0.3-μm-thick carbon interphase in a SiC fiber-reinforced SiC matrix composite was extracted from data acquired with a theoretical spot size of about 0.7 μm. Notably, conventional chemometrics procedures were unable to isolate the interphase signal, instead producing a spectrum representing a mixture of interphase and matrix. This study used another composite with approximately 0.9-μm-thick interphase to validate the analysis method, enabling direct measurement of the interphase spectrum. The proposed Raman analysis method has advantages in specimen volume and turnaround time compared to traditional characterization methods, such as transmission electron microscopy. In conclusion, this study also evaluates the applicability of the analysis method to different composite materials and identifies key requirements of the measurements, including the ratio of interphase thickness to spot size and the homogeneity of the surrounding matrix.

ceramic matrix composite↗

Utilization of O4 Slant Column Density to Derive Aerosol Layer Height from a Space-Borne UV-Visible Hyperspectral Sensor: Sensitivity and Case Study

The sensitivities of oxygen-dimer (O4) slant column densities (SCDs) to changes in aerosol layer height are investigated using the simulated radiances by a radiative transfer model, the linearized pseudo-spherical vector discrete ordinate radiative transfer (VLIDORT), and the differential optical absorption spectroscopy (DOAS) technique. The sensitivities of the O4 index (O4I), which is defined as dividing O4 SCD by 10(sup 40) molecules (sup 2) per centimeters(sup -5), to aerosol types and optical properties are also evaluated and compared. Among the O4 absorption bands at 340, 360, 380, and 477 nanometers, the O4 absorption band at 477 nanometers is found to be the most suitable to retrieve the aerosol effective height. However, the O4I at 477 nanometers is significantly influenced not only by the aerosol layer effective height but also by aerosol vertical profiles, optical properties including single scattering albedo (SSA), aerosol optical depth (AOD), particle size, and surface albedo. Overall, the error of the retrieved aerosol effective height is estimated to be 1276, 846, and 739 meters for dust, non-absorbing, and absorbing aerosol, respectively, assuming knowledge on the aerosol vertical distribution shape. Using radiance data from the Ozone Monitoring Instrument (OMI), a new algorithm is developed to derive the aerosol effective height over East Asia after the determination of the aerosol type and AOD from the MODerate resolution Imaging Spectroradiometer (MODIS). About 80 percent of retrieved aerosol effective heights are within the error range of 1 kilometer compared to those obtained from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) measurements on thick aerosol layer cases.

Air Pollution↗

Subnanometer Visualization of Spatially Varying Local Field Resonances that Drive Tip-Enhanced Optical Spectroscopy

Our knowledge of the electromagnetic fields that power modern nanoscale optical measurements, including (non)linear tip-enhanced Raman and photoluminescence, chiefly stems from numerical simulations. Aside from idealized in silico vs heterogeneous (nano)structures in the laboratory, challenges in quantitative descriptions of nanoscale light–matter interactions more generally stem from the very nature of the problem, which lies at the interface of classical and quantum theories. This is particularly the case in ultrahigh spatial resolution measurements that are sensitive to local optical field variations that take place on subnanometer length scales. Here this work approaches this challenge through extinction-based spectral nanoimaging experiments. We demonstrate <1 nm spatial resolution in hyperspectral extinction measurements that track spatially varying plasmon resonances. We describe the principles behind our experiments and highlight more general implications of our observations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Simultaneous Conoscopic Holography and Raman Spectroscopy

A new instrument was developed for chemical characterization of surfaces that combines the analytical power of Raman spectroscopy with the three-dimensional topographic information provided by conoscopic holography. The figure schematically depicts the proposed hybrid instrument. The output of the conoscopic holographic portion of the instrument is a topographical map of the surface; the output of the Raman portion of the instrument is hyperspectral Raman data, from which the chemical and/or biological composition of the surface would be deduced. By virtue of the basic principles of design and operation of the instrument, the hyperspectral image data would be inherently spatially registered with the topographical data. In conoscopic holography, the object and reference beams of classical holography are replaced by the ordinary and extraordinary components generated by a single beam traveling through a birefringent, uniaxial crystal. In the basic conoscopic configuration, a laser light is projected onto a specimen and the resulting illuminated spot becomes a point source of diffuse light that propagates in every direction. The laser beam is rasterscanned in two dimensions (x and y) perpendicular to the beam axis (z), and at each x,y location, the pattern of interference between the ordinary and extraordinary rays is recorded. The recorded interferogram constitutes the conoscopic hologram. Of particular significance for the proposed instrument is that the conoscopic hologram contains information on the z coordinate (height) of the illuminated surface spot. Hence, a topographical map of the specimen is constructed point-by-point by rastering the laser beam in the x and y directions and correlating the x and y coordinates with the z information obtained from the interferograms. Conoscopic imaging is an established method, and conoscopic laboratory instruments for surface metrology are commercially available. In Raman spectroscopy of a surface, one measures the spectrum of laser light scattered inelastically from a laser-illuminated spot on the surface. The wavelengths of the inelastically scattered light differ from that of the incident laser beam by amounts that correspond to the energies of molecular vibrations. The resulting vibrational spectrum can be used to identify the molecules. Raman spectroscopy is a standard laboratory technique for identifying mineralogical, biological, and other specific chemical compositions.

Schramm, Harry F.↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Discrimination of Hydrovolcanic Tephras from Volcanic and Non-Volcanic Backgrounds in Hyperspectral Data of Pavant Butte and Tabernacle Hill, Utah: Relevance for Mars

Water-magma, or ice-magma, interactions have long been theorized as an important process in the Martian geologic record [1-3]. The ability to unambiguously recognize tephra deposits and volcanic edifices produced by H2O-magma interactions is important for understanding the geologic history of Mars and for understanding the genesis of the major components of the Martian surface layer. Recognizing volcanic edifices produced by H2Omagma interactions on the basis of morphology alone is difficult.can be definitively identified as such. One means of providing supporting evidence for the identification of hydrovolcanic landforms and tephra deposits is through spectroscopy. Tephras produced by hydrovolcanic activity range from fresh basaltic glass (sideromelane) to glasses that have been completely altered to palagonite. A study of the visible through short-wave infrared (Vis-IR) reflectance of tephras composing tuff rings and tuff cones showed that the different stages of this alteration sequence have recognizable reflectance signatures [6,7]. However, the ability to recognize these different types of tephras against volcanic and nonvolcanic background materials has yet to be fully demonstrated. In this research, hyperspectral Vis-IR data over volcanic and hydrovolcanic terrains in the Black Rock Desert of Utah were analyzed in order to determine the separability of the component materials from volcanic and non-volcanic backgrounds.

Farrand, W. H.↗

High-Resolution NO2 Observations from the Airborne Compact Atmospheric Mapper: Retrieval and Validation

Nitrogen dioxide (NO2) is a short-lived atmospheric pollutant that serves as an air quality indicator and is itself a health concern. The Airborne Compact Atmospheric Mapper (ACAM) was flown on board the NASA UC-12 aircraft during the Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality Maryland field campaign in July 2011. The instrument collected hyperspectral remote sensing measurements in the 304-910 nm range, allowing daytime observations of several tropospheric pollutants, including nitrogen dioxide (NO2), at an unprecedented spatial resolution of 1.5 × 1.1 sq. km. Retrievals of slant column abundance are based on the differential optical absorption spectroscopy method. For the air mass factor computations needed to convert these retrievals to vertical column abundance, we include high-resolution information for the surface reflectivity by using bidirectional reflectance distribution function data from the Moderate Resolution Imaging Spectroradiometer. We use high-resolution simulated vertical distributions of NO2 from the Community Multiscale Air Quality and Global Modeling Initiative models to account for the temporal variation in atmospheric NO2 to retrieve middle and lower tropospheric NO2 columns (NO2 below the aircraft). We compare NO2 derived from ACAM measurements with in situ observations from NASA's P-3B research aircraft, total column observations from the ground-based Pandora spectrometers, and tropospheric column observations from the space-based Ozone Monitoring Instrument. The high-resolution ACAM measurements not only give new insights into our understanding of atmospheric composition and chemistry through observation of subsampling variability in typical satellite and model resolutions, but they also provide opportunities for testing algorithm improvements for forthcoming geostationary air quality missions.

Lamsal, L. N.↗

Site-level Foliar C, N, delta13C data from samples collected during field survey associated with NEON AOP survey, East River, CO 2018

Carbon (C) and nitrogen (N) weight percent concentrations were obtained from the bulk foliar samples collected across East River, Washington Gulch, Slate River, and Coal Creek watersheds in Gunnison, Colorado during the summer of 2018. These samples were collected from sun-lit leaves of meadow, shrub, and tree vegetation types within 72 hours of the National Ecological Observatory Network Airborne Observation Platform (NEON AOP) hyperspectral survey. These samples were dried and then run on an elemental analyzer coupled to a mass spectrometer for C and N concentrations and delta13C. The intention of these data were to provide ground truth data to develop foliar nutrient models across the imaging spectroscopy domain. Additional associated site metadata and vegetation fractional cover information can be found in the associated data releases (DOI: 10.15485/1618130). Here we provide site level C, N, and delta 13C data in the CN_Results_Foliar.csv. All of these samples were also registered with IGSN codes, and the details from that registration with metadata for the samples is included in foliar_sample_igsn_metadata.csv.

54 ENVIRONMENTAL SCIENCES↗

Development of Machine Learning Algorithms to Segment and Study Images of Astromaterial Samples

Introduction: Micrometer-scale chemical analyses of chondritic meteorites and mission-returned asteroid samples can reveal details of the physical and chemical processes operating in the early solar system, including processes that gave rise to planets, moons, and minor bodies. These primitive astromaterials are comprised of chondrules, calcium- and aluminum-rich inclusions (CAI), and many other silicates, oxides, metals, sulfides, and fine-grained materials. The chemical and mineralogical complexity of these samples, vast populations of different components, and heterogeneity across mm to km scales, all limit our understanding of the origin and evolution of these materials. Here, we describe recent efforts to use machine learning techniques to automate the segmentation of chemical maps of chondritic meteorites, designed to aid studies of asteroid samples returned by spacecraft. By automating the task of segmentation it will become possible to rapidly analyze and interpret the sizes, shapes, mineralogy, chemistry, and other properties of every chondrule, calcium- and aluminum-rich inclusion (CAI) and other clast within and between asteroid samples. Sample return missions significantly accelerate and heighten the need to develop such new data analysis techniques, and associated data repositories. Techniques: Neural networks require abundant training data, i.e. images which have been segmented by a human user. We have manually segmented data available from previous petrologic and chemical work at NASA Johnson Space Center and the American Museum of Natural History [1-4]. These data were derived from energy- and wavelength-dispersive X-ray spectroscopy (EDS, WDS) mapping of samples from many chondrite groups. The Deeplabv3+ [5] neural network architecture was trained on human-labeled masks and used to create machine-labeled masks. Several different algorithms were investigated, with inputs ranging from common RGB image formats through to hyperspectral datasets, with raw data comprising greyscale maps of Mg, Ca, and Al, with or without Si, Fe, Ti for both EDS and WDS data, and extending to other elements in EDS only. Each greyscale image was paired with a binary mask for each labelled particle type. Results: The trained algorithms can segment (Fig 1), classify, and measure the dimensions of thousands of particles in chemical maps of a standard 1-inch round petrographic section in seconds to minutes, rather than many hours needed by a human. Accuracy of the algorithms varied from chondrite to chondrite and across particle types. Further results and details of the algorithms will be presented at the workshop. Future directions: Machine learning has the potential to revolutionize our understanding of complex particle populations contained within primitive astromaterial, with segmentation being a critical first step. Example applications include better understanding of particle transport, nebular reservoirs, parent body accretion, and a deeper understanding of the relationships between particle populations and bulk rock elemental and isotopic compositions. In addition to benefits that machine learning can bring to individual researchers, building a community data repository of thousands to millions of particles across hundreds of samples will open up many other possibilities. For example, with a large enough dataset it will be possible to search for exceptionally closely matching particles across disparate samples. Such a capability would enable a single CAI from OSIRISREx or Hayabusa/II samples to be matched to chondritic CAIs that exhibit near-identical size, texture, and mineralogy, down to the level of similar core phenocrysts, zonation, and rim sequences. Such comparative analyses will help to disentangle precursor chemistry, chronology, gas/dust reservoirs during heating, and accretion. Such an endeavor would be impossible without machine learning and a large community data repository of astromaterial chemical/mineralogic maps.

Machine Learning↗

Near-field imaging of optical resonances in silicon metasurfaces using photoelectron microscopy

Precise control of light–matter interactions at the nanoscale lies at the heart of nanophotonics. However, experimental examination at this length scale is challenging since the corresponding electromagnetic near-field is often confined within volumes below the resolution of conventional optical microscopy. In semiconductor nanophotonics, electromagnetic fields are further restricted within the confines of individual subwavelength resonators, limiting access to critical light–matter interactions in these structures. In this work, we demonstrate that photoelectron emission microscopy (PEEM) can be used for polarization-resolved near-field spectroscopy and imaging of electromagnetic resonances supported by broken-symmetry silicon metasurfaces. We find that the photoemission results, enabled through an in situ potassium surface layer, are consistent with full-wave simulations and far-field reflectance measurements across visible and near-infrared wavelengths. In addition, we uncover a polarization-dependent evolution of collective resonances near the metasurface array edge taking advantage of the far-field excitation and full-field imaging of PEEM. Here, we deduce that coupling between eight resonators or more establishes the collective excitations of this metasurface. All told, we demonstrate that the high-spatial resolution hyperspectral imaging and far-field illumination of PEEM can be leveraged for the metrology of collective, non-local, optical resonances in semiconductor nanophotonic structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stratigraphy of the Apollo 17 Landslide Core 73002 From FMR Maturity and VNIR and Mössbauer Spectroscopy

A suite of samples from the Apollo missions to the Moon (1969-1973) were set aside and stored under controlled conditions to have unexamined lunar samples available decades later for analyses that take advantage of evolved sample handling techniques, maturation of then existing instrumentation, and development of new analytical techniques and instrumentation [e.g., 1]. One preserved sample is the Apollo 17 double drive tube core (73001/2) that was driven into the lunar surface on the landslide deposit at Station 3 on the South Massif in the Taurus-Littrow valley [2]. The deeper section (73001) was stored frozen in a Core Sample Vacuum Container (CSVC) to maximize preservation of lunar volatiles. We report here, as a part of the Apollo Next Generation Sample Analysis (ANGSA) Initiative [1,3], stratigraphy for the upper core section (73002) with respect to maturity (ferromagnetic resonance (FMR) maturity index Is/FeO [4-6]), visible-near-IR (VNIR) spectroscopy, and, for representative samples, grain-size analysis and Mössbauer spectroscopy. Stratigraphy provides data to model the dynamics of lunar landslide deposits and their post-emplacement evolution in comparison to impact-driven mixing on an airless body and stratigraphic context for volatile and (if any) organic behavior. Reported by [7] are preliminary results for multispectral imaging and hyperspectral scanning of the first dissection pass of 73002.

R. V. Morris↗

Spatially dependent H-bond dynamics at interfaces of water/biomimetic self-assembled lattice materials

Significance It is challenging to develop biomimetic lattice self-assemblies because such materials need to resemble the flexibility and crystallinity of their biological analog. We show that these materials exhibit unique micro- and mesoscopic-ordered ultrafast hydrogen-bond dynamics, which could be a key feature in the lattice self-assembly: the ultrafast dynamics ensure flexibility, whereas the domain-level ordering reflects crystallinity. This scientific insight cannot be revealed without the ultrafast transient vibrational sum-frequency generation microscope, which integrates ultrafast interfacial spectroscopy with interfacial molecular vibrational imaging––a state-of-the-art development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separating Physically Distinct Mechanisms in Complex Infrared Plasmonic Nanostructures via Machine Learning Enhanced Electron Energy Loss Spectroscopy

Electron energy loss spectroscopy (EELS) enables direct exploration of plasmonic phenomena at the nanometer level. To isolate individual plasmon modes, linear unmixing methods can be used to separate different physical mechanisms, but in larger and more complex systems the interpretability of the components becomes uncertain. Here, infrared plasmonic resonances in self-assembled heterogeneous monolayer films of doped-semiconductor nanoparticles are examined beyond linear unmixing techniques, and both supervised and unsupervised machine-learning-based analyses of hyperspectral EELS datasets are demonstrated. Additionally, in the supervised approach, a human operator labels a small number of pixels in the hyperspectral dataset corresponding to features of interest which are then propagated across the entire dataset. In the unsupervised approach, non-linear autoencoders are used to create a highly-reduced latent-space representation of the dataset, within which insight into the relevant physics can be gleaned from straightforward distance metrics that do not depend on operator input and bias. The advantage of these approaches is that the labeling separates physical mechanisms without altering the data, enabling robust analyses of the influence of heterogeneities in mesoscale complex systems.

36 MATERIALS SCIENCE↗

Autonomous elemental characterization enabled by a low cost robotic platform built upon a generalized software architecture

Despite the rapidly growing applications of robots in industry, the use of robots to automate tasks in scientific laboratories is less prolific due to the lack of generalized methodologies and the high cost of hardware. This paper focuses on the automation of characterization tasks necessary for reducing cost while maintaining generalization and proposes a software architecture for building robotic systems in scientific laboratory environments. A dual-layer (Socket.IO and ROS) action server design is the basic building block, which facilitates the implementation of a web-based front end for user-friendly operation and the use of ROS Behavior Trees for convenient task planning and execution. A robotic platform for automating mineral and material sample characterization is built upon the architecture, with an open-source, low-cost three-axis computer numerical control gantry system serving as the main robot. A handheld laser induced breakdown spectroscopy (LIBS) analyzer is integrated with a 3D printed adapter, enabling (1) automated 2D chemical mapping and (2) autonomous sample measurement (with the support of an RGB-Depth camera). We demonstrate the utility of automated chemical mapping by scanning the surface of a spodumene-bearing pegmatite core sample with a 1071-point dense hyperspectral map acquired at a rate of 1520 bits per second. Furthermore, we showcase the autonomy of the platform in terms of perception, dynamic decision-making, and execution, through a case study of LIBS measurement of multiple mineral samples. The platform enables controlled and autonomous chemical quantification in the laboratory that complements field-based measurements acquired with the same handheld device, linking resource exploration and processing steps in the supply chain for lithium-based battery materials.

Cao, Xuan [Lawrence Berkeley National Laboratory (↗

NASA Tech Briefs, June 2008

Topics covered include: Charge-Control Unit for Testing Lithium-Ion Cells; Measuring Positions of Objects Using Two or More Cameras; Lidar System for Airborne Measurement of Clouds and Aerosols; Radiation-Insensitive Inverse Majority Gates; Reduced-Order Kalman Filtering for Processing Relative Measurements; Spaceborne Processor Array; Instrumentation System Diagnoses a Thermocouple; Chromatic Modulator for a High-Resolution CCD or APS; Commercial Product Activation Using RFID; Cup Cylindrical Waveguide Antenna; Aerobraking Maneuver (ABM) Report Generator; ABM Drag_Pass Report Generator; Transformation of OODT CAS to Perform Larger Tasks; Visualization Component of Vehicle Health Decision Support System; Mars Reconnaissance Orbiter Uplink Analysis Tool; Problem Reporting System; G-Guidance Interface Design for Small Body Mission Simulation; DSN Scheduling Engine; Replacement Sequence of Events Generator; Force-Control Algorithm for Surface Sampling; Tool for Merging Proposals Into DSN Schedules; Micromachined Slits for Imaging Spectrometers; Fabricating Nanodots Using Lift-Off of a Nanopore Template; Making Complex Electrically Conductive Patterns on Cloth; Special Polymer/Carbon Composite Films for Detecting SO2; Nickel-Based Superalloy Resists Embrittlement by Hydrogen; Chemical Passivation of Li+-Conducting Solid Electrolytes; Organic/Inorganic Polymeric Composites for Heat-Transfer Reduction; Composite Cathodes for Dual-Rate Li-Ion Batteries; Improved Descent-Rate Limiting Mechanism; Alignment-Insensitive Lower-Cost Telescope Architecture; Micro-Resistojet for Small Satellites; Using Piezoelectric Devices to Transmit Power through Walls; Miniature Latching Valve; Apparatus for Sampling Surface Contamination; Novel Species of Non-Spore-Forming Bacteria; Chamber for Aerosol Deposition of Bioparticles; Hyperspectral Sun Photometer for Atmospheric Characterization and Vicarious Calibrations; Dynamic Stability and Gravitational Balancing of Multiple Extended Bodies; Simulation of Stochastic Processes by Coupled ODE-PDE; Cluster Inter-Spacecraft Communications; Genetic Algorithm Optimizes Q-LAW Control Parameters; Low-Impact Mating System for Docking Spacecraft; Non-Destructive Evaluation of Materials via Ultraviolet Spectroscopy; Gold-on-Polymer-Based Sensing Films for Detection of Organic and Inorganic Analytes in the Air; and Quantum-Inspired Maximizer.

Source record↗

HyTES: Thermal Imaging Spectrometer Development

The Jet Propulsion Laboratory has developed the Hyperspectral Thermal Emission Spectrometer (HyTES). It is an airborne pushbroom imaging spectrometer based on the Dyson optical configuration. First low altitude test flights are scheduled for later this year. HyTES uses a compact 7.5-12 micrometer m hyperspectral grating spectrometer in combination with a Quantum Well Infrared Photodetector (QWIP) and grating based spectrometer. The Dyson design allows for a very compact and optically fast system (F/1.6). Cooling requirements are minimized due to the single monolithic prism-like grating design. The configuration has the potential to be the optimal science-grade imaging spectroscopy solution for high altitude, lighter-than-air (HAA, LTA) vehicles and unmanned aerial vehicles (UAV) due to its small form factor and relatively low power requirements. The QWIP sensor allows for optimum spatial and spectral uniformity and provides adequate responsivity which allows for near 100mK noise equivalent temperature difference (NEDT) operation across the LWIR passband. The QWIP's repeatability and uniformity will be helpful for data integrity since currently an onboard calibrator is not planned. A calibration will be done before and after eight hour flights to gage any inconsistencies. This has been demonstrated with lab testing. Further test results show adequate NEDT, linearity as well as applicable earth science emissivity target results (Silicates, water) measured in direct sunlight.

remote sensing↗