High Resolution Imaging of the Sun with CORONAS-1

We applied several image restoration and enhancement techniques, to CORONAS-I images. We carried out the characterization of the Point Spread Function (PSF) using the unique capability of the Blind Iterative Deconvolution (BID) technique, which recovers the real PSF at a given location and time of observation, when limited a priori information is available on its characteristics. We also applied image enhancement technique to extract the small scale structure imbeded in bright large scale structures on the disk and on the limb. The results demonstrate the capability of the image post-processing to substantially increase the yield from the space observations by improving the resolution and reducing noise in the images.

Karovska, Margarita↗

Optical correlator use at Johnson Space Center

For automation and robotics in the Space Station era, NASA's Johnson Space Center is pursuing several means of synthetic vision. The optical correlator is one such means. The deformable mirror device will form the basis of the first correlator in this project. In-house and contracted effort is being used. Initial in-house activities will concentrate on an impulse deconvolution technique and on a programmable retina for spatial remappings of an image prior to correlation. The retina will permit a form of edge extraction and other primitive operations. Additionally, it will be used as a research tool for assisting persons with low vision.

Juday, Richard D.↗

Narrow band imagery in the 8-14 micron spectral region

The problem of deconvolution of the point source response function (PSF) for two-dimensional imaging infrared arrays is addressed. A variety of phenomena can lead to PSF degradation, ranging from atmospheric turbulence to the array itself. The maximum entropy algorithm is used to demonstrate that substantial image quality improvements are possible in the case of a PSF which is degraded by electronic rather than optical smearing. This result implies that IR arrays need not have perfect or even very good pixel-pixel crosstalk rejection ratios for use in astronomy.

Goebel, J. H.↗

Ground Testing of the MISSE-16 Materials

The harsh space environment imposes very stringent requirements upon spacecraft materials, especially those located on exterior surfaces of space objects in low Earth orbit (LEO). As humankind moves from space exploration to space commercialization, these materials may have to last for 15–20 years without considerable degradation of their optical, electrical, mechanical, and thermal properties. Operational requirements dictate that these materials continue to function according to expectations. Hence, we must understand the effects of the space environment on materials currently in use as well as on untested materials. For the years, the Materials International Space Station Experiment Flight Facility (MISSE-FF) have flown many different materials to investigate the effect of LEO space weather exposure on the performance and durability of materials and devices. The MISSE-16 scientific team members plan to launch fifteen different novel and well-characterized spacecraft-relevant materials to the LEO environment for a duration of six months during the MISSE-16 mission. Changes in spectral reflectivity will be measured throughout the mission as the samples are exposed to the space environment. The same chemical damage the produces changes in optical reflectance also causes changes in numerous other physical properties such as electrical conductivity, mechanical strength, and chemical reactivity. Correlation of the changes in each of these properties as a function of radiation type, flux, and fluence allows various material properties to be inferred from one experimentally tractable measurement: color change. Flying identical test fixtures on the ram, zenith, and wake positions of the MISSE-FF, collecting spectrally resolved images of the materials, and concomitantly measuring the ambient space environment allows deconvolution of the material effects which occur as a result of exposure to neutral atomic oxygen (AO), unfiltered solar ultraviolet (UV) radiation, and electrons. The flight experiment will function as a ground truth reference for our team’s ongoing laboratory-based space weather-material interactions experiments. Comparison of the MISSE-16 data with extensive testing of “flight-duplicate” samples under simulated space weather conditions will enable development of chemical models for prediction of material degradation. This paper discusses preliminary results from the ground test campaign including measurements of UV/VIS/IR reflectance spectra, bidirectional reflectance distribution function (BRDF), surface potential decay, and surface morphology under electron and AO exposure.

Elena A. Plis↗

Deconvolution of a pre-outburst picture of SN 1987A

The block iterative method (Young 1971) of algebraic image restoration is applied to a photographic plate of the field around SN 1987A obtained 4 yr before outburst by Chu at the CTIO 4-m telescope. By setting appropriate constraints for the solution on a pixel-by-pixel basis, the image of a starfield centered on Sk -69 202, the precursor to the supernova, is restored. It is found that this star has two companions, which others (e.g., Walborn et al., 1987 and West et al., 1987) have also noted and designated as Star 2 and Star 3. Also found is marginal evidence for Star 4, a weak source at theta = 222 deg, r = 1.9 arcsec. Correction for the contributions of these companions yields an estimate of the magnitude for Sk -69 202 alone of V = 12.37.

Heap, Sara R.↗

Single-Filament Imaging Mass Spectrometry Lipidomics in Arthrospira platensis

Elucidating intra-organismal biochemical and lipid organization in photosynthetic biological cell factories of filamentous cyanobacteria, i.e., Arthrospira platensis (Spirulina), is important to track physiological response mechanisms during growth. Little is known about the filaments' biochemical organization and cellular structure and no label-free imaging techniques exist that provide molecular mapping. We applied ultra-high resolution mass spectrometry (7T FT-ICR-MS) matrix-assisted laser desorption ionization (MALDI) imaging to immobilized Spirulina filaments to investigate the localization of lipids across distinct physiological regions. We optimized matrix selection and deposition methods with the goal of facilitating high spatial, and intra-filament, resolution using untargeted multivariate statistical spectral deconvolution across MS pixels. Our results demonstrate an improved two step application with an optimized procedure for intra-organismal lipid profiling to improve analyte sensitivity and achieve higher spatial resolution, whereby we evaluate three conventional matrices 2,5-dihydroxybenzoic acid (DHB), a 9:1 ratio of DHB:superDHB (sDHB), 1,5- diaminonaphthalene (DAN) and a 50:50 mix of DHB:sDHB and compare delineation and pixel-based elucidation of intra-filament lipidomics. We identified a total of 1,626 features that could be putatively assigned a lipid-like formula based on database query and 46 unique features, with associated lipid assignments that were significantly distinct in their intra-filament location. MALDI- imaging MS with untargeted statistical spectral deconvolution was used to visualize intra-filament lipidomics organization in Spirulina filaments. Improvements in matrix deposition, including sequential sublimation and pneumatic spraying, increased signal abundance at high spatial resolution and allowed for identification of distinct lipid composition regions. Here in this work outlines a methodology that may be used for micro-ecological untargeted molecular phenotyping.

09 BIOMASS FUELS↗

Space Telescope astrometry from CCD images

The astrometric application of the Wide Field Camera and the Planetary Camera is reviewed. It is shown that the digital image centering algorithms can yield a positional accuracy of 0.1 milli-arcsecond. Deconvolution of CCD's sensitivity, non-flatness of the filters, and crinkling of the CCD surface may limit the positional accuracy of 1 milli-arcsecond.

Chiu, L.-T. G.↗

Development and applications of laser-induced incandescence

Several NASA-funded investigations focus on soot processes and radiative influences of soot in diffusion flames given their simplicity, practical significance, and potential for theoretical modeling. Among the physical parameters characterizing soot, soot volume fraction, f(sub v), a function of particle size and number density, is often of chief practical interest in these investigations, as this is the geometrical property that directly impacts radiative characteristics and the temperature field of the flame and is basic to understanding soot growth and oxidation processes. Diffusion flames, however, present a number of challenges to the determination of f(sub v) via traditional extinction measurements. Laser-induced incandescence (LII) possesses several advantages compared to line-of-sight extinction techniques for determination of f(sub v). Since LII is not a line-of-sight technique, similar to fluorescence, it possesses geometric versatility allowing spatially resolved measurements of f(sub v) in real time in nonaxisymmetric systems without using deconvolution techniques. The spatial resolution of LII is determined by the detector and imaging magnification used. Neither absorption by polycyclic aromatic hydrocarbons (PAH's) nor scattering contributes to the signal. Temporal capabilities are limited only by the laser pulse and camera gate duration, with measurements having been demonstrated with 10 ns resolution. Because of these advantages, LII should be applicable to a variety of combustion processes involving both homogeneous and heterogeneous phases. Our work has focussed on characterization of the technique as well as exploration of its capabilities and is briefly described.

Vanderwal, Randy L.↗

An artificial intelligence’s interpretation of complex high-resolution in situ transmission electron microscopy data

Complicated nano- and atomic-scale processes with sub-angstrom spatial resolution and millisecond time resolution visualized by in situ transmission electron microscopy (TEM) are often highly dynamical and time consuming to analyze and interpret. Here, we report how variational autoencoders (VAEs) can provide an artificial intelligence’s interpretation of high-resolution in situ TEM data by condensing and deconvoluting complicated atomic-scale dynamics into a latent space with reduced dimensionality. We designed a VAE model with high latent dimensions capable of deconvoluting information from complex high-resolution TEM data. We demonstrate how this model, with high latent dimensions trained on atomically resolved TEM images of lead sulfide (PbS) nanocrystals, is able to capture movements and perturbations of periodic lattices in both simulated and real in situ TEM data. Importantly, the VAE model shows the capability of detecting and deconvoluting dynamical nanoscale physical processes, such as the rotation of crystal lattices and intra-particle ripening during the annealing of semiconductor nanocrystals.

47 OTHER INSTRUMENTATION↗

Instrument-induced spatial crosstalk deconvolution algorithm

An algorithm has been developed which reduces the effects of (deconvolves) instrument-induced spatial crosstalk in satellite image data by several orders of magnitude where highly precise radiometry is required. The algorithm is based upon radiance transfer ratios which are defined as the fractional bilateral exchange of energy betwen pixels A and B.

Wright, Valerie G.↗

Platform for Postprocessing Waveform-Based NDE

Taking advantage of the similarities that exist among all waveform-based non-destructive evaluation (NDE) methods, a common software platform has been developed containing multiple- signal and image-processing techniques for waveforms and images. The NASA NDE Signal and Image Processing software has been developed using the latest versions of LabVIEW, and its associated Advanced Signal Processing and Vision Toolkits. The software is useable on a PC with Windows XP and Windows Vista. The software has been designed with a commercial grade interface in which two main windows, Waveform Window and Image Window, are displayed if the user chooses a waveform file to display. Within these two main windows, most actions are chosen through logically conceived run-time menus. The Waveform Window has plots for both the raw time-domain waves and their frequency- domain transformations (fast Fourier transform and power spectral density). The Image Window shows the C-scan image formed from information of the time-domain waveform (such as peak amplitude) or its frequency-domain transformation at each scan location. The user also has the ability to open an image, or series of images, or a simple set of X-Y paired data set in text format. Each of the Waveform and Image Windows contains menus from which to perform many user actions. An option exists to use raw waves obtained directly from scan, or waves after deconvolution if system wave response is provided. Two types of deconvolution, time-based subtraction or inverse-filter, can be performed to arrive at a deconvolved wave set. Additionally, the menu on the Waveform Window allows preprocessing of waveforms prior to image formation, scaling and display of waveforms, formation of different types of images (including non-standard types such as velocity), gating of portions of waves prior to image formation, and several other miscellaneous and specialized operations. The menu available on the Image Window allows many further image processing and analysis operations, some of which are found in commercially-available image-processing software programs (such as Adobe Photoshop), and some that are not (removing outliers, Bscan information, region-of-interest analysis, line profiles, and precision feature measurements).

Roth, Don↗

Deconvolution of SNPP VIIRS Solar Diffuser Bidirectional Reflectance Distribution Function On-orbit Change Factor

The Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly calibrates its reflective solar bands (RSBs), primarily through observing an onboard sunlit solar diffuser (SD). The on-orbit change of the value of the SD bidirectional reflectance distribution function (BRDF) is quantified by a numerical factor, called the H-factor, and is determined by the onboard SD stability monitor (SDSM). Because the spectral response function of an SDSM detector spreads in wavelength, the directly measured H-factor is the true H-factor convolved with the spectral response function. To find the true H-factor, we use the traditional direct method and an innovative iterative approach to separately deconvolve the measured H-factor. Our iterative approach relies on two properties of the SDSM detector spectral response function: the central peak width is narrow enough so that the H-factor does not change much over the peak width, and the dominance of the spectral response function’s integral with respect to the wavelength over the width. The iterative approach is more accurate, of a smaller noise impact, much more flexible in terms of interpolation and extrapolation of function values, and faster. We have used deconvolved H-factors to calibrate the NASA SNPP VIIRS RSB Collections 1 and 2 Level-1B products.

SNPP VIIRS↗

Deconvolution of X-ray natural and magnetic circular dichroism in chiral Dy-ferroborate

Structural chirality and magnetism, when intertwined, can have profound implications on materials properties. Using X-ray imaging and spectroscopic measurements that leverage the natural and magnetic circular dichroic effects present in magnetized chiral crystal structures, we probe the interplay between chirality and magnetism across the field-induced spin-flop transition of Dy ferroborate, DyFe 3 (BO 3 ) 4 . Deconvolution of natural and magnetic circular dichroic signals at the Fe K and Dy L 2,3 absorption edges of the non-centrosymmetric structure was enabled by use of tunable temperature and magnetic field, providing access to element-specific magnetic information across the spin-flop transition. The magnetic response of Fe and Dy sublattices was found to be independent of domain chirality. The chiral domains were robust against both the (chirality preserving) R32 to P3 1 21/P3 2 21 structural phase transition at 280 K, and application of magnetic field up to 4 Tesla. A third flavor of X-ray dichroism, magneto-chiral dichroism, was not detected within the accuracy of our measurements. The absence of significant Fe magnetization along the screw, c-axis for the magnetic field strength used in this study, together with non-linear coupling of magnetic field to electric polarization across the spin-flop transition, may hinder observation of magneto-chiral dichroic effects in this system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deducing Electron Properties from Hard X-Ray Observations

X-radiation from energetic electrons is the prime diagnostic of flare-accelerated electrons. The observed X-ray flux (and polarization state) is fundamentally a convolution of the cross-section for the hard X-ray emission process(es) in question with the electron distribution function, which is in turn a function of energy, direction, spatial location and time. To address the problems of particle propagation and acceleration one needs to infer as much information as possible on this electron distribution function, through a deconvolution of this fundamental relationship. This review presents recent progress toward this goal using spectroscopic, imaging and polarization measurements, primarily from the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI). Previous conclusions regarding the energy, angular (pitch angle) and spatial distributions of energetic electrons in solar flares are critically reviewed. We discuss the role and the observational evidence of several radiation processes: free-free electron-ion, free-free electron-electron, free-bound electron-ion, photoelectric absorption and Compton backscatter (albedo), using both spectroscopic and imaging techniques. This unprecedented quality of data allows for the first time inference of the angular distributions of the X-ray-emitting electrons and improved model-independent inference of electron energy spectra and emission measures of thermal plasma. Moreover, imaging spectroscopy has revealed hitherto unknown details of solar flare morphology and detailed spectroscopy of coronal, footpoint and extended sources in flaring regions. Additional attempts to measure hard X-ray polarization were not sufficient to put constraints on the degree of anisotropy of electrons, but point to the importance of obtaining good quality polarization data in the future.

Kontar, E. P.↗

Timing Analysis with INTEGRAL: Comparing Different Reconstruction Algorithms

INTEGRAL is one of the few instruments capable of detecting X-rays above 20keV. It is therefore in principle well suited for studying X-ray variability in this regime. Because INTEGRAL uses coded mask instruments for imaging, the reconstruction of light curves of X-ray sources is highly non-trivial. We present results from the comparison of two commonly employed algorithms, which primarily measure flux from mask deconvolution (ii-lc-extract) and from calculating the pixel illuminated fraction (ii-light). Both methods agree well for timescales above about 10 s, the highest time resolution for which image reconstruction is possible. For higher time resolution, ii-light produces meaningful results, although the overall variance of the lightcurves is not preserved.

Grinberg, V.↗

A simple method for correcting spatially resolved solar intensity oscillation observations for variations in scattered light

A measurement of the intensity distribution in an image of the solar disk will be corrupted by a spatial redistribution of the light that is caused by the earth's atmosphere and the observing instrument. A simple correction method is introduced here that is applicable for solar p-mode intensity observations obtained over a period of time in which there is a significant change in the scattering component of the point spread function. The method circumvents the problems incurred with an accurate determination of the spatial point spread function and its subsequent deconvolution from the observations. The method only corrects the spherical harmonic coefficients that represent the spatial frequencies present in the image and does not correct the image itself.

Jefferies, S. M.↗

High resolution obtained by photoelectric scanning techniques.

Several applications of linear scanning of different types of objects are described; examples include double stars, satellites, the Red Spot of Jupiter and a landing site on the moon. This technique allows one to achieve a gain of about an order of magnitude in resolution over conventional photoelectric techniques; it is also effective in providing sufficient data for removing background effects and for the application of deconvolution procedures. Brief consideration is given to two-dimensional scanning, either at the telescope or of electronographic images in the laboratory. It is suggested that some of the techniques described should be given serious consideration for space applications.

Hall, J. S.↗

Evaluation of partial volume correction and analysis of longitudinal [ 18 F]GTP1 tau PET imaging in Alzheimer's disease using linear mixed-effects models

Purpose: We evaluated the impact of partial volume correction (PVC) methods on the quantification of longitudinal [ 18 F]GTP1 tau positron-emission tomography (PET) in Alzheimer's disease and the suitability of describing the tau pathology burden temporal trajectories using linear mixed-effects models (LMEM). Methods: We applied van Cittert iterative deconvolution (VC), 2-compartment, and 3-compartment, and the geometric transfer matrix plus region-based voxelwise methods to data acquired in an Alzheimer's disease natural history study over 18 months at a single imaging site. We determined the optimal PVC method by comparing the standardized uptake value ratio change (%ΔSUVR) between diagnostic and tau burden–level groups and the longitudinal repeatability derived from the LMEM. The performance of LMEM analysis for calculating %ΔSUVR was evaluated in a natural history study and in a multisite clinical trial of semorinemab in prodromal to mild Alzheimer's disease by comparing results to traditional per-visit estimates. Results: The VC, 2-compartment, and 3-compartment PVC methods had similar performance, whereas region-based voxelwise overcorrected regions with a higher tau burden. The lowest within-subject variability and acceptable group separation scores were observed without PVC. The LMEM-derived %ΔSUVR values were similar to the per-visit estimates with lower variability. Conclusion: The results indicate that the tested PVC methods do not offer a clear advantage or improvement over non-PVC images for the quantification of longitudinal [ 18 F]GTP1 PET data. LMEM offers a robust framework for the longitudinal tau PET quantification with low longitudinal test–retest variability. Clinical trial registration: NCT02640092 and NCT03289143.

60 APPLIED LIFE SCIENCES↗