Search NASA⌕ Search

SEARCH · Search NASA

Results for “image velocimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).

Wernet, Mark P.↗

The Isolated Synthetic Jet in Crossflow: A Benchmark for Flow Control Simulation

An overview of the data acquisition, reduction, and uncertainty of experimental measurements of the flowfield created by the interaction of an isolated synthetic jet and a turbulent boundary layer is presented. The experimental measurements were undertaken to serve as the second of three computational fluid dynamics validation databases for Active Flow Control. The validation databases were presented at the NASA Langley Research Center Workshop on CFD Validation of Synthetic Jets and Turbulent Separation Control in March, 2004. Detailed measurements were made to document the boundary conditions for the flow and also for the phase-averaged flowfield itself. Three component Laser-Doppler Velocimetry, 2-D Particle Image Velocimetry, and Stereo Particle Image Velocimetry were utilized to document the phase averaged velocity field and the turbulent stresses.

Schaeffler, Norman W.↗

The Isolated Synthetic Jet in Crossflow: A Benchmark for Flow Control Simulation

An overview of the data acquisition, reduction, and uncertainty of experimental measurements made of the flowfield created by the interaction of an isolated synthetic jet and a turbulent boundary layer is presented. The experimental measurements were undertaken to serve as the second of three computational fluid dynamics validation databases for Active Flow Control. The validation databases were presented at the NASA Langley Research Center Workshop on CFD Validation of Synthetic Jets and Turbulent Separation Control in March, 2004. Detailed measurements were made to document the boundary conditions for the flow and also for the phase-averaged flowfield itself. Three component Laser-Doppler Velocimetry, 2-D Particle Image Velocimetry, and Stereo Particle Image Velocimetry were utilized to document the phase-averaged velocity field and the turbulent stresses.

Schaeffler, Norman W.↗

Instantaneous velocity field measurements of a turbulent rectangular jet (AR-4) using particle image displacement velocimetry

A whole field experimental technique, commonly referred to as Particle Image Displacement Velocimetry (PIDV) is used for the measurement of the two dimensional instantaneous velocity fields in the transition region of a three dimensional jet issuing from a rectangular nozzle of an aspect ratio 4. The instability process of an initially laminar jet is studied visually and quantitatively to determine the structure and growth of the mixing region of the jet. The experiments were performed using an air jet at a Reynolds number based on the hydraulic diameter of 3600. The roll-up of the laminar shear layer into vortices and their subsequent interactions are examined.

Lourenco, L.↗

Devices that Alter the Tip Vortex of a Rotor

Small devices were attached near the tip of a hovering rotor blade 'in order to alter the structure and trajectory of the trailing vortex. Stereo particle image velocimetry (PIV) images were used to quantify the wake behind the rotor blade during the first revolution. A procedure for analyzing the 3D-velocity field is presented that includes a method for accounting for vortex wander. The results show that a vortex generator can alter the trajectory of the trailing vortex and that a major change in the size and intensity of the trailing vortex can be achieved by introducing a high level of turbulence into the core of the vortex.

McAlister, Kenneth W.↗

Measurement of Separated Flow Structures Using a Multiple-Camera DPIV System

A novel multiple-camera system for the recording of digital particle image velocimetry (DPIV) images acquired in a two-dimensional separating/reattaching flow is described. The measurements were performed in the NASA Langley Subsonic Basic Research Tunnel as part of an overall series of experiments involving the simultaneous acquisition of dynamic surface pressures and off-body velocities. The DPIV system utilized two frequency-doubled Nd:YAG lasers to generate two coplanar, orthogonally polarized light sheets directed upstream along the horizontal centerline of the test model. A recording system containing two pairs of matched high resolution, 8-bit cameras was used to separate and capture images of illuminated tracer particles embedded in the flow field. Background image subtraction was used to reduce undesirable flare light emanating from the surface of the model, and custom pixel alignment algorithms were employed to provide accurate registration among the various cameras. Spatial cross correlation analysis with median filter validation was used to determine the instantaneous velocity structure in the separating/reattaching flow region illuminated by the laser light sheets. In operation the DPIV system exhibited a good ability to resolve large-scale separated flow structures with acceptable accuracy over the extended field of view of the cameras. The recording system design provided enhanced performance versus traditional DPIV systems by allowing a variety of standard and non-standard cameras to be easily incorporated into the system.

Humphreys, William M., Jr.↗

Forced Diffusion of Trailing Vorticity from a Hovering Rotor

A small turbulence generating device was Attached near the tip of a hovering rotor blade In order to alter the structure of the trailing vortex. Stereo particle image velocimetry (PIV) images were used to quantify the wake behind the rotor blade during the first revolution. An analysis of the 3D-velocity field includes a method for accounting for vortex wander. The results show that a major change in the size and intensity of the trailing vortex can be achieved.

McAlister, Kenneth W.↗

Vertical Lunar Regolith Conveying as a Flight Experiment in Simulated Lunar-Gravity

Regolith conveying will be an essential task for supplying regolith feedstock to In-Situ Resource Utilization (ISRU) reactor systems for regolith processing on the Moon and Mars. The Vertical Lunar Regolith Conveyor (VLRC) is a technology being developed at NASA Kennedy Space Center (KSC) as a regolith transport task for the GCD ISRU FLEET project led by NASA Glenn Research Center (GRC). Single test loop versions of the VLRC are being developed at NASA KSC as a technology demonstration for a flight experiment. The NASA Flight Opportunities program selected the VLRC for a technology demonstration opportunity on a future Blue Origin New Shepard suborbital launch vehicle to study regolith transport physics in a relevant environment in a vacuum chamber under simulated lunar gravity conditions in order to advance its technology readiness level (TRL) for future space applications. The VLRC system includes four primary subsystems to achieve the objectives of the lunar gravity (Lunar-G) flight experiment. (1) An eccentric vibratory conveyor stack to convey regolith particles consisting of three single-loop helical surface conveyors with each actuated by two vibratory motors that vibrate in unison. One of the three single-loops contains a 0.8°-3.1° inclined helical path and the other two contain a 1.6°-6.2° incline. (2) A stick-slip conveyor stack to convey regolith particles consisting of three single-loop helical surface conveyors with each actuated by the same motor to move in unison in a stick-slip motion. One of the three single-loops contains a 0.8°-3.1° inclined helical path and the other two contain a 1.6°-6.2° incline. (3) A regolith containment system to contain the regolith in each single-loop track during launch before the start of the experiment using containment caps that will be lifted in unison at the start of Lunar-G. (4) COTS cameras will record the motion of regolith and tracer particles. Post-flight analysis of the videos will be used to determine convey speeds and flow rates. The VLRC experiment will use the well-known technique of Particle Image Velocimetry (PIV) image analysis to determine the velocity of tracer particles entrained in the regolith flow. This velocity will be used to calculate the mass flow rate of the regolith being conveyed.

ISRU↗

Particle Seeding Method for Small-Scale, High-Pressure Nozzles

NASA tests new launch and reentry vehicle configurations in wind tunnels, where flow visualizations and quantitative flowfield measurements are often desired. Some of these vehicles have rocket motors for propulsion, retro-propulsion, or reaction control. High-pressure air is used to supply these rocket motor plumes. However, it is difficult to make off-body measurements in these regions, for several reasons. First, the plumes themselves lack seeding particles for flow diagnostics, and at the low pressures after expansion, Rayleigh scattering or other molecular techniques yield insufficient signal for flow velocity measurements. Second, the plumes displace particle-seeded tunnel air, preventing measurements in the vicinity of the plume. Third, the plumes force shock waves ahead of the vehicle, which melts the ice crystal fog commonly used for visualization and measurement techniques in certain facilities. In the current work, a novel method for seeding the flow in these small-scale, high-pressure nozzles has been devised and initially demonstrated, potentially enabling quantitative and qualitative measurements with particle-based instruments such as Doppler global velocimetry or particle image velocimetry. The method involves a Venturi contraction to draw the seed liquid out of a reservoir and into the nozzle channel, wherein shearing forces atomize the seed into particles. The concept was tested with a laser sheet visualization, which demonstrated that the flow rate of liquid spray was controllable; a valve could be adjusted to drop the flow rate by up to 65%. This relatively inexpensive and simple technique may prove useful in wind tunnel experiments involving particle-based laser diagnostics and small, high-pressure nozzles.

lasers↗

Particle image displacement velocimetry measurements of a three-dimensional jet

A whole field experimental technique, commonly referred to as particle image displacement velocimetry (PIDV), is used for the measurement of the instantaneous two-dimensional velocity fields in the transition region of a three-dimensional jet issuing from a rectangular nozzle with aspect ratio 4. The experiments were performed using an air jet at a Reynolds number based on the hydraulic diameter of 3600. The rollup of the laminar shear layer into vortices and their subsequent interactions are examined.

Lourenco, L.↗

PIV/HPIV Film Analysis Software Package

A PIV/HPIV film analysis software system was developed that calculates the 2-dimensional spatial autocorrelations of subregions of Particle Image Velocimetry (PIV) or Holographic Particle Image Velocimetry (HPIV) film recordings. The software controls three hardware subsystems including (1) a Kodak Megaplus 1.4 camera and EPIX 4MEG framegrabber subsystem, (2) an IEEE/Unidex 11 precision motion control subsystem, and (3) an Alacron I860 array processor subsystem. The software runs on an IBM PC/AT host computer running either the Microsoft Windows 3.1 or Windows 95 operating system. It is capable of processing five PIV or HPIV displacement vectors per second, and is completely automated with the exception of user input to a configuration file prior to analysis execution for update of various system parameters.

Blackshire, James L.↗

Development of a Large Field-of-View PIV System for Rotorcraft Testing in the 14- x 22-Foot Subsonic Tunnel

A Large Field-of-View Particle Image Velocimetry (LFPIV) system has been developed for rotor wake diagnostics in the 14-by 22-Foot Subsonic Tunnel. The system has been used to measure three components of velocity in a plane as large as 1.524 meters by 0.914 meters in both forward flight and hover tests. Overall, the system performance has exceeded design expectations in terms of accuracy and efficiency. Measurements synchronized with the rotor position during forward flight and hover tests have shown that the system is able to capture the complex interaction of the body and rotor wakes as well as basic details of the blade tip vortex at several wake ages. Measurements obtained with traditional techniques such as multi-hole pressure probes, Laser Doppler Velocimetry (LDV), and 2D Particle Image Velocimetry (PIV) show good agreement with LFPIV measurements.

Jenkins, Luther N.↗

The development of laser speckle or particle image displacement velocimetry. Part 1: The role of photographic parameters

One of the difficult problems in experimental fluid dynamics remains the determination of the vorticity field in fluid flows. Recently, a novel velocity measurement technique, commonly known as Laser Speckle or Particle Image Displacement Velocimetry became available. This technique permits the simultaneous visualization of the 2 dimensional streamline pattern in unsteady flows and the quantification of the velocity field. The main advantage of this new technique is that the whole 2 dimensional velocity field can be recorded with great accuracy and spatial resolution, from which the instantaneous vorticity field can be easily obtained. A apparatus used for taking particle displacement images is described. Local coherent illumination by the probe laser beam yielded Young's fringes of good quality at almost every location of the flow field. These fringes were analyzed and the velocity and vorticity fields were derived. Several conclusions drawn are discussed.

Lourenco, L. M. M.↗

PIV Measurements of a Low-noise Top-mounted Propulsion Installation for a Supersonic Airliner

A model-scale exhaust system was tested to validate low-noise propulsion concepts and noise prediction methods. The tests involved far-field acoustics, phased array, and particle image velocimetry (PIV). This paper covers the particle image velocimetry portion. Data was acquired at NASA Glenn's Aero-Acoustic Propulsion Lab for a series of nozzles with different chevron designs, both uninstalled and installed on a representative aircraft planform. The impact of the various chevron treatments on the turbulent velocity field was documented, along with the impact of the pylon and planform. When correlated with far-field acoustic measurements and phased array measurements, reported in companion papers, the explanation of acoustic benefits from top-mounted propulsion is clear as is the path toward optimization of the concept.

Propulsion Airframe Integration↗

Physical Analysis and Scaling of a Jet and Vortex Actuator

Our previous studies have shown that the Jet and Vortex Actuator generates free-jet, wall-jet, and near- wall vortex flow fields. That is, the actuator can be operated in different modes by simply varying the driving frequency and/or amplitude. For this study, variations are made in the actuator plate and wide-slot widths and sine/asymmetrical actuator plate input forcing (drivers) to further study the actuator induced flow fields. Laser sheet flow visualization, particle- image velocimetry, and laser velocimetry are used to measure and characterize the actuator induced flow fields. Laser velocimetry measurements indicate that the vortex strength increases with the driver repetition rate for a fixed actuator geometry (wide slot and plate width). For a given driver repetition rate, the vortex strength increases as the plate width decreases provided the wide-slot to plate-width ratio is fixed. Using an asymmetric plate driver, a stronger vortex is generated for the same actuator geometry and a given driver repetition rate. The nondimensional scaling provides the approximate ranges for operating the actuator in the free jet, wall jet, or vortex flow regimes. Finally, phase-locked velocity measurements from particle image velocimetry indicate that the vortex structure is stationary, confirming previous computations. Both the computations and the particle image velocimetry measurements (expectantly) show unsteadiness near the wide-slot opening, which is indicative of mass ejection from the actuator.

Lachowicz, Jason T.↗

Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data

Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. Results Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.

4D-flow MRI↗

Experimental Evaluation of an Isolated Synthetic Jet IN Crossflow

The second case for this workshop builds upon the isolated synthetic jet of Case 1 by adding a crossflow, with no streamwise pressure gradient, for the developing jet to interact with. Formally, Case 2 examines the interaction of a single, isolated, synthetic jet and a fully turbulent zero-pressure gradient boundary layer. The resulting flow has many of the characteristics that need to be modeled with fidelity if the results of the calculations are to serve as the basis for research and design with active flow control devices. These include the turbulence in the boundary layer, the time-evolution of the large vortical structure emanating from the jet orifice and its subsequent interaction with and distortion by the boundary layer turbulence, and the effect of the suction cycle on the boundary layer flow. In a synthetic jet, the flow through the orifice and out into the outer flowfield alternates between an exhaust and a suction cycle, driven by the contraction and expansion of a cavity internal to the actuator. In the present experiment, the volume changes in the internal cavity are accomplished by replacing one of the rigid walls of the cavity, the wall opposite the orifice exit, with a deformable wall. This flexible wall is driven by a bottom-mounted moveable piston. The piston is driven electro-mechanically. The synthetic jet issues into the external flow through a circular orifice. In the present experiment, this orifice has a diameter of 0.250 inches (6.35 mm). The flow is conceptually similar to that documented in Schaeffler [1]. To document the flow, several measurement techniques were utilized. The upstream boundary conditions (in-flow conditions), and several key phase-averaged velocity profiles were measured with a 3-component laser-Doppler velocimetry system. Phase-averaged velocity field measurements were made with both stereo digital particle image velocimetry and 2-D digital particle image velocimetry as the primary measurement system. Surface pressure measurements were made utilizing an electronically scanned pressure system.

Schaeffler, Norman W.↗

PIV Measurements of the CEV Hot Abort Motor Plume for CFD Validation

NASA s next manned launch platform for missions to the moon and Mars are the Orion and Ares systems. Many critical aspects of the launch system performance are being verified using computational fluid dynamics (CFD) predictions. The Orion Launch Abort Vehicle (LAV) consists of a tower mounted tractor rocket tasked with carrying the Crew Module (CM) safely away from the launch vehicle in the event of a catastrophic failure during the vehicle s ascent. Some of the predictions involving the launch abort system flow fields produced conflicting results, which required further investigation through ground test experiments. Ground tests were performed to acquire data from a hot supersonic jet in cross-flow for the purpose of validating CFD turbulence modeling relevant to the Orion Launch Abort Vehicle (LAV). Both 2-component axial plane Particle Image Velocimetry (PIV) and 3-component cross-stream Stereo Particle Image Velocimetry (SPIV) measurements were obtained on a model of an Abort Motor (AM). Actual flight conditions could not be simulated on the ground, so the highest temperature and pressure conditions that could be safely used in the test facility (nozzle pressure ratio 28.5 and a nozzle temperature ratio of 3) were used for the validation tests. These conditions are significantly different from those of the flight vehicle, but were sufficiently high enough to begin addressing turbulence modeling issues that predicated the need for the validation tests.

Wernet, Mark↗