Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Rapid neutron and gamma-ray source localization using machine learning

Rapid localization of radiation sources is critical for applications including nuclear emergency response, safeguards, and security. However, conventional imaging systems such as neutron scatter cameras and Compton cameras depend on rare coincidence events, which often result in long acquisition times. In this work, we address the challenge of rapid source localization by developing a machine learning approach to predict the direction of a single radiation source using only count rates from an array of neutron and gamma-ray detectors. The proposed model is a fully connected neural network (FCNN) trained using Monte Carlo simulation data from a 252 Cf source. The model hyperparameters are optimized with a small set of routine 252 Cf measurements. We benchmarked the performance of the trained and optimized machine learning model using additional 252 Cf , 137 Cs , and PuBe measurements under laboratory conditions with varying source-detector configurations. For these measurements, the machine learning model achieved a mean localization error smaller than 30° with 3 x 10 3 system counts, corresponding to 8 s measurement time for the imaging system used in this work. In this low-statistics regime, the method outperformed traditional scatter-based imaging by more than 75% in localization accuracy for the evaluated measurement configurations. These results demonstrate that a machine learning-based approach can significantly reduce the time required for accurate single-source localization, providing a robust and computationally efficient alternative to traditional imaging systems in time-critical nuclear security and emergency response scenarios.

Gamma-ray imaging↗

First look at neutron emission shape characteristics of ignition hotspots at the National Ignition Facility (invited)

The nuclear imaging system has been capturing neutron images of inertial confinement fusion (ICF) driven implosions for over a decade at the National Ignition Facility. This imaging system has evolved from one to three nearly orthogonal lines-of-sight, allowing for the study of three-dimensional shape characteristics of ignition shots. Limited-view tomography algorithms help visualize the burning hotspot in 3D and assess neutron source geometry using Legendre mode parameters. With its neutron, gamma-ray, and x-ray image reconstruction capabilities, NIS has provided critical insight into mechanisms that have limited implosion performance, such as fill tube diameter for ignition-type targets. This comprehensive diagnostic suite opens a window into the shape characteristics of ignition shots and how symmetry affects ICF implosion performance. In more recent ignition shots, neutron yields have visibly increased. Analyzing the shape and size of the reconstructed neutron source has shown an expansion of the burn volume, which is indicative of more efficient alpha heating during the implosion process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combining visible shadowgraph imaging with x-ray imaging for dynamic shock experiments

Interrogating ejecta particles launched from target materials that are undergoing dynamic shock can be done with both x-ray imaging and visible shadowgraph imaging. Our dynamic testing must be done inside a containment vessel with limited access ports available. We designed an imaging system to relay both types of imaging systems through a single port using the same optical relay and then splitting the images onto three separate high-speed imaging cameras outside the containment vessel. X-ray imaging provides ejecta density measurements. Shadowgraph imaging that is done at two wavelengths (blue and red) constrains ejecta particle size distributions and provides areal density measurements of the ejecta cloud. The ejecta particles are positioned 225 mm before the x-ray scintillators; this arrangement permits a folded mirror system to allow the shadowgraph data to bypass the x-ray scintillators. This configuration results in spatial separations between the intermediate image planes of the x-ray and shadowgraph images along the optical axis. At the position of the x-ray intermediate image plane, mirrors are positioned such that the shadowgraph images are kicked out and their images are sent on to different cameras. Positioning of the large doublet relay lenses keeps shrapnel from impacting the vessel containment windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated imaging assembly and method for using

Certain disclosed embodiments concern an integrated imaging system that combined light-sheet microscopy, which enables considerable speed and phototoxicity gains, with quantitative-phase imaging. A method for using such imaging systems also is disclosed. In an exemplary embodiment, an integrated imaging system was used for multivariate investigation of live-cells in microfluidics.

Vasdekis, Andreas E.↗

Three-dimensional broadband nonlinear phased array imaging

System include an ultrasonic transducer configured to couple to a nondestructive testing (NDT) sample and configured to produce and direct an ultrasonic probe wave at a selected frequency into a subsurface region of the NDT sample, a 3D laser scanning vibrometer configured to direct a detection beam in a scan area on a surface of the NDT sample and to receive a return beam from the scan area, and to detect, based on the return beam, a 3D motion of the surface across a wideband frequency range, and a processor, and a memory configured with instructions that, when executed by the processor, cause the processor to produce sub-surface image data of the NDT sample at multiple harmonics of the selected frequency in the wideband frequency range based on the detected 3D surface motion, wherein the sub-surface image data describes a nonlinear defect response produced in the NDT sample by interaction of the ultrasonic probe wave with the subsurface region.

Remillieux, Marcel↗

System and method for testing true stress and true strain

A true stress testing system broadly comprising a force input machine, an imaging system, and a computer. The imaging system includes a light source for projecting a light beam at the specimen in a first direction and a camera positioned on an opposite side of the specimen for receiving portions of the light beam not blocked by the specimen such that a shadow image of the specimen is created via the camera. The computer may determine a minimum dimension of the specimen perpendicular to the first direction at a point in time over a plurality of points along the force axis via the shadow image of the specimen such that the processor accounts for changes in position of the minimum dimension along the specimen. A true stress of the specimen may then be determined according to the minimum dimension of the specimen perpendicular to the first direction at the point in time.

42 ENGINEERING↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Cost X-Ray CT System for Imaging of Roots

The goal of this project was to develop and demonstrate an innovative, low cost, field deployable, stationary 3D x-ray computed tomography (CT) system that will image total root phenotypes with a micron size resolution at a throughput of hundreds of plants per cycle. This system is based on UHV’s unique low cost linear x-ray tube technology and sophisticated reconstruction & image segmentation algorithms developed at University of Massachusetts, Lowel and University of Nottingham; and was tested for several types of soils at University of Wisconsin and Texas A&M University. Currently, no technologies exist that have been designed to image roots in complex media such as agricultural field conditions. Due to its small size, high resolution & fast imaging of fine roots, low power consumption, large penetration depth (i.e. ability to see through several feet of soil) and ease of field deployability, this CT system will increase the speed and efficacy of discovery, field translation, and deployment of improved crops and systems that improve soil carbon accumulation and storage, decrease N2O emissions, and improve water efficiency leading towards advancements that could mitigate 10% of the total US Greenhouse gases. This degree of imaging in the field has never been available and would be invaluable to scientists in understanding how environmental conditions and phenotypic variations contribute to carbon deposition through root development.

54 ENVIRONMENTAL SCIENCES↗

Label-free quantum super-resolution imaging using entangled multi-mode squeezed light

Abstract In this study, we explore the theoretical application of entangled multi-mode squeezed light for label-free optical super-resolution imaging. By generating massively entangled multi-mode squeezed light through an array of balanced beam splitters, using a single-mode squeezed light input, we create a multi-mode quantum light state with exceptional entanglement and noise suppression below the shot noise level. This significantly reduces imaging measurement errors compared to classical coherent state light imaging when the same number of photons are used on the imaging sample. We demonstrate how to optimize the imaging system’s parameters to achieve the Heisenberg imaging error limit, taking into account the number of entangled modes and photons used. We also examine the effects of optical losses in the imaging system, necessitating adjustments to the optimized parameters based on the degree of optical loss. In practical applications, this new quantum imaging approach reduces the number of photons needed to achieve the same image quality by two orders of magnitude compared to classical imaging methods that use non-entangled, non-squeezed coherent state light.

Soh, Daniel (ORCID:0000000325625675)↗

Compressive sensing optical design and simulation tool

A system or method for designing optical systems includes generating a mathematical model of an imaging system; tracing a plurality of light rays from a source through the model of the imaging system in a forward direction and a backward direction incident upon an arbitrarily defined detector location; calculating the total light rays incident upon the arbitrarily defined detector location in response to the plurality of light rays; tracing a series of calibration images first through the computational or compressive imager mathematical model; measuring an output set of parameters based on a plurality of detected rays calibration images at the defined detector location; storing the output set of parameters in software, and determining an estimated system transfer function.

42 ENGINEERING↗

Gamma-ray imaging of Np-237 metal using an organic glass imager

Neutron and gamma-ray imaging systems are deployed within the field of nuclear safeguards for the detection and localization of special nuclear materials and other materials of interest. 237 Np is one of these materials of interest due its presence in spent nuclear fuel and potential for use in nuclear weapons when purified. Here, for the first time, a 6 kg neptunium sphere (98.8 wt% 237 Np) was measured using a dual-particle imager, from the University of Michigan, consisting of organic glass and inorganic scintillators. The novel composition of organic glass scintillator was recently developed at Sandia National Labs and has been used in particle imaging systems due to its time resolution and particle discrimination capabilities. Gamma-ray energy spectra from single and coincident events were extracted and the sequencing of Compton scatter and photoelectric absorption gamma-ray events was used to generate images using simple backprojection. The emissions of interest in this work are the 312 keV and 416 keV gamma rays from 233 Pa, a daughter isotope from the neptunium decay series. The results of this work show that there is close agreement between the true source location in angular space and the converged location from the gamma ray images created using the system. The gamma spectroscopy from single and coincident events also identified the characteristic emission from the daughter isotope and could be used to assist with the identification of 237 Np. Furthermore, successful localization of the source with 5 s of data demonstrates the practical application of the imaging system for imaging and detection of material in weapons-useable quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

Apparatus, method and system for imaging and utilization of SEM charged particles

A scanning electron microscope (SEM) system includes an SEM objective that emits an electron beam toward a sample, causing emission of charged particles including secondary electrons, Auger electrons, backscattered electrons, anions and cations. The SEM system includes electron optics elements that are configured to establish electric fields around the sample that accelerate charged particles toward a detector. A two-dimensional distribution of locations of incidence of the charged particles on the detector is indicative of energies of the charged particles and their emission angles from the sample. A three-dimensional spatial distribution of charged particles emitted from the sample is recovered by performing an Abel transform over the distribution on the detector. The energies and emission angles of the charged particles are then determined from the three-dimensional spatial distribution.

42 ENGINEERING↗

Image registration for accurate electrode deformation analysis in operando microscopy of battery materials

Operando imaging techniques have become increasingly valuable in both battery research and manufacturing. However, the reliability of these methods can be compromised by instabilities in the imaging setup and operando cells, particularly when utilizing high-resolution imaging systems. The acquired imaging data often include features arising from both undesirable system vibrations and drift, as well as the scientifically relevant deformations occurring in the battery sample during cell operation. For meaningful analysis, it is crucial to distinguish and separately evaluate these two factors. To address these challenges, we employ a suite of advanced image-processing techniques. These include fast Fourier transform analysis in the frequency domain, power spectrum-based assessments for image quality, as well as rigid and non-rigid image-registration methods. These techniques allow us to identify and exclude blurred images, correct for displacements caused by motor vibrations and sample holder drift and, thus, prevent unwanted image artifacts from affecting subsequent analyses and interpretations. Additionally, we apply optical flow analysis to track the dynamic deformation of battery electrode materials during electrochemical cycling. This enables us to observe and quantify the evolving mechanical responses of the electrodes, offering deeper insights into battery degradation. Together, these methods ensure more accurate image analysis and enhance our understanding of the chemomechanical interplay in battery performance and longevity.

Sun, Tianxiao↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Neutron Imaging Using Organic Glass Scintillators

In this work, we develop of a compact neutron imaging system based on organic glass scintillator and silicon photomultiplier arrays. The recently developed organic glass scintillator has excellent neutron and gamma-ray detection efficiency and exhibits pulse shape discrimination capability that is nearly as good as current state-of-the-art materials such as trans-stilbene. We have cast and characterized 6 mm by 6 mm by 50 mm bars of organic glass in our laboratory. When coupled to a silicon photomultiplier array, these bars demonstrated better energy and timing resolution than the stilbene organic scintillator. Here, this performance makes organic glass an ideal material for a compact neutron imaging system, which must resolve neutron scatter events on a sub-nanosecond time scale. We have demonstrated neutron imaging with bars of organic glass scintillator coupled to arrays of silicon photomultipliers. Additional bars of organic glass will be implemented into the system to improve the efficiency and imaging performance. The resulting system will be demonstrated using 252 Cf and PuBe neutron sources in our laboratory. In addition, we will compare imaging performance to other compact neutron imaging systems that exist in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model development for flash boiling spray and validations with isooctane, hexane, ethanol and their binary mixtures

The objective of this study is to develop a comprehensive model for spray atomization under the consideration of flash boiling, which includes nucleation, bubble growth, and droplet breakup. Although flash boiling has been previously studied, there is still no well-established analytical and numerical model of their mechanisms, or general guidelines on the implementation of this atomization strategy. In this study, detailed formulations are elaborated for the unified spray atomization model under both non-flash and flash boiling conditions. Next, the model was implemented into CFD software and 3-D simulations were performed for model validations. Two fuel blends are tested: ethanol-isooctane blends and hexane-isooctane blends. Simulation results were compared with the experimental measurements conducted using two methodologies, DBI (Diffuse Backlight Imaging) system for spray images captured by a high-speed camera, and a PDA (Phase Doppler Anemometry) system for droplet size measurement during the spray injection process. It was found that the current flash boiling model can accurately capture the spray characteristics under different environment conditions, such as the spray plume interactions and liquid penetration. The averaged Sauter mean diameter (SMD) calculations match the measurement sufficiently well. The spray structures for both single- and multi-component fuels during the injection process are well represented by current model.

42 ENGINEERING↗