Search NASA⌕ Search

SEARCH · Search NASA

Results for “impact study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Degradation and recovery of solid oxide fuel cell performance by control of cathode surface acidity: Case study – Impact of Cr followed by Ca infiltration

Solid oxide fuel cells (SOFC) have attracted attention as clean and efficient energy conversion devices with low emissions. However, several degradation mechanisms limit the electrochemical performance of current SOFCs, with cathode degradation due to Cr-poisoning from metal interconnects particularly problematic. The acidity/basicity of binary additives has been found to be a sensitive descriptor of the oxygen exchange kinetics, indicating that acidic Cr-species/basic Ca-species can be expected to deactivate/activate the cathode surface, respectively. Inspired by recent advances, the feasibility of relative acidity as a tool for reviving degraded SOFCs is demonstrated by neutralizing Cr-poisoned SOFCs by subsequent serial infiltration of Ca-species. Furthermore, a model mixed ionic and electronic conducting oxide, Pr 0.1 Ce 0.9 O 2-δ (PCO), is selected as the cathode material. Area-specific resistances (ASR) of symmetric cells obtained by electrochemical impedance spectroscopy show that Cr-infiltration results in a seven-fold increase in ASR, while subsequent infiltration of Ca-species leads to complete recovery. Performance degradation and recovery are attributed to depressed/enhanced redox properties at the PCO surface, as supported by XPS analysis. Experiments using anode-supported fuel cells show a reduction in peak power density by 26% upon Cr-infiltration, reversed following Ca-infiltration, after which no degradation is observed during subsequent operation for 100 h.

(Pr,Ce)O2-δ↗

Electron-impact study of the PH radical using the R-matrix method

The PH radical is an interesting case to study because of its {pi}{sup 2} electronic configuration, which leads to the three low-lying electronic states, X {sup 3{Sigma}-}, a {sup 1{Delta}}, and b {sup 1{Sigma}+}. The singlet states possess long lifetimes, because direct combination with the ground state is not allowed. This is similar to the O{sub 2} case. The R-matrix method is employed to calculate elastic differential and integral cross sections, momentum-transfer cross sections, and inelastic cross sections. The energy range is 0-10 eV. The Hartree-Fock ground-state configuration of PH is 1{sigma}{sup 2}2{sigma}{sup 2}3{sigma}{sup 2}1{pi}{sup 4}4{sigma}{sup 2}5{sigma}{sup 2}2{pi}{sup 2}. We have included thirty-seven target states in the trial wave function of the scattering system in our best model. Each target state is represented by a configuration interaction (CI) wave function. In our CI model, we freeze ten electrons in orbitals 1{sigma}, 2{sigma}, 3{sigma}, and 1{pi}; the remaining six electrons are free to move among the seven orbitals 4{sigma}, 5{sigma}, 6{sigma}, 7{sigma}, 8{sigma}, 2{pi}, and 3{pi}. Our CI model yields a dipole moment of 0.67 D at the equilibrium PH bond length, R{sub e}, of 2.687 a{sub 0}; this dipole moment compares favorably with the experimental value 0.70 D. We have carried our scattering calculations in one state with the CI wave function and thirty-seven-state model. We have detected a stable anionic bound state {sup 2}B{sub 1} of PH at various bond lengths of PH molecule. The vertical electron affinity value is 0.97 eV, which is in excellent agreement with experimental value of 1.00 eV. We have included up to g partial waves in the scattering calculations. The contribution of higher partial waves is accounted for by using a Born-closure procedure.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron-impact study of the SO radical using the R-matrix method

The SO radical with an even number of electrons belongs to an open-shell system due to its {pi}{sup 2} ground-state electronic configuration. This configuration gives rise to three low-lying states X {sup 3}{Sigma}{sup -}, a {sup 1}{Delta}, and b {sup 1}{Sigma}{sup +}. The inclusion of these target states in a trial wave function of the entire scattering have important implications in the resonances that may be detected in this open-shell molecule. The R-matrix method is a well-established ab initio formalism which is employed to calculate elastic differential and integral cross sections, momentum-transfer cross sections, and inelastic cross sections. The Hartree-Fock ground-state configuration of SO is 1{sigma}{sup 2}2{sigma}{sup 2}3{sigma}{sup 2}4{sigma}{sup 2}1{pi}{sup 4}5{sigma}{sup 2}6{sigma}{sup 2}7{sigma}{sup 2}2{pi}{sup 4}3{pi}{sup 2}. We have included 28 target states in the trial wave function of the scattering system. In our configuration-interaction (CI) model, we freeze 12 electrons in orbitals 1{sigma}, 2{sigma}, 3{sigma}, 4{sigma}, and 1{pi}, the remaining 12 electrons are free to move among the eight orbitals 4{sigma}, 5{sigma}, 6{sigma}, 7{sigma}, 8{sigma}, 9{sigma}, 2{pi}, and 3{pi}. We have carried our scattering calculations in static-exchange, one-state with CI wave function, and 28-state models. We have detected a stable anionic bound state {sup 2}B{sub 1} of SO at various bond lengths of SO molecule. The vertical electron affinity value is 0.970 eV, which is comparable to the experimental value of 1.125 eV. We also detected two core-excited shape resonances, both of {sup 2}{Pi} symmetry and with {sup 1}{Delta} and {sup 1}{Sigma}{sup +} as the parent states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hardware-in-the-Loop (HIL) Simulations for Smart Grid Impact Studies

Hardware-in-the-loop (HIL) simulations are increasingly employed in power engineering as more inverter-based generation and smart appliances are connected to the electric grid. HIL techniques allow for the co-simulation of analytical models with actual devices whose complex behavior is computationally inefficient or difficult to model. They also allow for testing the behavior of these devices under adverse conditions that rarely occur in the field but are important to evaluate. This paper provides an overview of how HIL simulations have been used to date and proposes that HIL simulations should play an important role in evaluating new control strategies, especially at the distribution level, that are being proposed to allow for continued affordable and reliable operation of the electric grid. We present a new capability that was developed to evaluate the interactions between residential loads and the smart grid: smart home hardware-in-the-loop. The paper includes results from an HIL experiment that incorporates multiple technologies and controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data, scripts, and figures associated with a manuscript studying impact of climate and topography on post-fire vegetation recovery.

This data package is associated with the publication “Impact of Topography and Climate on Post-fire Vegetation Recovery Across Different Burn Severity and Land Cover Types through Machine Learning” submitted to Remote Sensing of Environment (Zahura et al. 2023). In this research, a machine learning algorithm, random forest (RF), was utilized to examine the impact of climate and topography on post-fire vegetation recovery. We used enhanced vegetation index (EVI) to examine varying burn severity and land cover types. The data package includes the input files for RF model training, outputs from model predictions and analysis, and python scripts to run the model, analyze the results to understand model performance and interpretability, and plot manuscript figures. This data package contains three folders (Data, Scripts, and Figures), a file-level metadata (FLMD) csv, and a data dictionary (dd) csv. Please see Postfire_recovery_flmd.csv for a list of all files contained in this data package and descriptions for each. The data dictionary (Postfire_recovery_dd.csv) describes the csv column headers. The “Data” folder provides all the inputs and outputs to train the RF model, evaluate performance, and interpret predictions. The “Scripts” folder contains python scripts and jupyter notebooks for model training and result analysis. The “Figures” folder includes the figures used in the manuscript in “.png” and “.jpg” format.

54 ENVIRONMENTAL SCIENCES↗

Formulating a simplified equivalent representation of distribution circuits for PV impact studies.

With an increasing number of Distributed Generation (DG) being connected on the distribution system, a method for simplifying the complexity of the distribution system to an equivalent representation of the feeder is advantageous for streamlining the interconnection study process. The general characteristics of the system can be retained while reducing the modeling effort required. This report presents a method of simplifying feeders to only specified buses-of-interest. These buses-of-interest can be potential PV interconnection locations or buses where engineers want to verify a certain power quality. The equations and methodology are presented with mathematical proofs of the equivalence of the circuit reduction method. An example 15-bus feeder is shown with the parameters and intermediate example reduction steps to simplify the circuit to 4 buses. The reduced feeder is simulated using PowerWorld Simulator to validate that those buses operate with the same characteristics as the original circuit. Validation of the method is also performed for snapshot and time-series simulations with variable load and solar energy output data to validate the equivalent performance of the reduced circuit with the interconnection of PV.

Reno, Matthew J.↗

Li-FSI Impurity Impact Study: Final CRADA Report

There is growing interest in lithium bis(fluorosulfonyl)imide (LiFSI ) as an alternative to LiPF6 and as an additive to electrolytes used in lithium-ion cells. LiFSI has attracted attention because it is reported to have higher ionic conductivity, better high temperature stability, and enhanced stability toward hydrolysis, Also, LiFSI additive to electrolytes can bring benefits of improved storage properties and reduced gas evolution in the cells. Different levels of different electrochemically active impurities could affect the performance of LiFSI as an electrolyte salt for Li-ion batteries, generating inconsistent and conflicting interpretations of the experimental data.

25 ENERGY STORAGE↗

Long Beach Climate Resiliency Study: Impacts on Water Supply and Demand

The City of Long Beach is located in a semi-arid region with finite natural water supplies. Long Beach has established itself as a leader in conservation, achieving a 31% reduction in gallons per capita per day (GPCD) from the 1980’s to today. However, due to the arid climate of the Southwest, specifically Southern California with its large population, there is not enough naturally occurring water to meet demands without importing water from other regions. Long Beach is no exception and obtains 39% of water supply from imported sources. Additionally, the 54% originating from groundwater is partially dependent upon imported sources for recharge. Recycled water makes up just 7% of the water supply portfolio. Plans to expand the recycled water system have not yet been realized. Currently, purchasing imported water is more cost effective for Long Beach than expanding the recycled water system or constructing a desalination facility. However, stress on imported water supplies from climate change could drive up prices and make expansions of local supplies more economically attractive.

54 ENVIRONMENTAL SCIENCES↗

Lahaina Wildfire Study: Impacts of Post-Disaster Housing Programs on Maui’s Economy

In August 2023, wildfires destroyed more than 4,000 housing units in Maui County, Hawaiʻi, primarily in the town of Lahaina. One hundred and two people were killed, making it the deadliest wildfire in the United States in more than a century.1 The fire displaced 13,000 people; 5,000 found new housing without government assistance, and 8,000 applied for assistance.

99 GENERAL AND MISCELLANEOUS↗

Impact Study of Metal Fasteners in Roofing Assemblies using Three-Dimensional Heat Transfer Analysis

Heat transfer analysis was performed on typical roofing assemblies using HEAT3, a three-dimensional heat transfer analysis software. The difference in heat transferred through the roofing assemblies considered is compared between two cases - without any steel fasteners and with steel fasteners. In the latter case, the metal roofing fasteners were arranged as per Factor Mutual Global (FMG) approvals, in the field, perimeter, and corner zones of the roof. The temperature conditions used for the analysis represented summer and winter conditions for three separate Climate Zones (CZ) namely Climate Zone 2 or CZ2 represented by Orlando, FL; CZ3 represented by Atlanta, GA; and CZ6 zone represented by St. Paul, MN. In all the climatic conditions, higher energy transfer was observed with increase in the number of metal fasteners attributed to high thermal conductivity of metals as compared to the insulation and other materials used in the roofing assembly. This difference in heat loss was also quantified in the form of percentage change in the overall or effective insulation of the roofing assembly for better understanding of the practical aspects. Besides, a comparison of 2D heat transfer analysis (using THERM software) and 3D analysis using HEAT3 is also discussed.

3D modeling↗