Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedance of transformers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Autonomous Infrared and Small (Wide) Angle X-Ray Scattering (IR-S(W)AXS) Capability

Thin water films are 2-D, nanoconfined layers that form on solid surfaces exposed to humid atmospheres—environments ubiquitous across catalysis, corrosion science, soil science, and subsurface geochemistry. At relative humidity (RH) values below saturation, these films are Å–nm thick and exhibit properties that differ sharply from bulk water, including disrupted H-bonding and impeded mass transport. Owing to their high surface-to-volume ratio, dissolution of the solid can rapidly drive strong supersaturation with respect to secondary phases. Reactivity in thin water films is highly sensitive to film thickness, and critically, thickness evolves during reaction because the hygroscopicity of the interfacial system changes as ions accumulate or diminish in the film and as reaction products transform. To accurately probe and control these dynamics, a capability is needed that can measure and automatically maintain a constant water-film thickness while simultaneously monitoring solid dissolution, nucleation, and growth. This project developed an autonomous Infrared/Small Angle X-ray Scattering-Wide Angle X-ray Scattering (IR/(W)SAXS) for investigating reactivity in thin water films on solid surfaces exposed to humidified gases. The capability consists of an IR spectrometer, a (W)SAXS instrument, and a mass flow controller system for generating variably humidified gas flows to a custom reaction cell. Progress on each of the major components of the capability are detailed below.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact Analysis of High-Altitude Electromagnetic Pulse Coupling Effects on Power Grid Protection Relays

Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.

42 ENGINEERING↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Revealing the Electrochemical Kinetics of Electrolytes in Nanosized LiFePO 4 Electrodes

Lithium-ion battery rate performance is ultimately limited by the electrolyte, yet the behaviors of electrolytes during high-rate (dis)charge remain elusive to electrochemical measurement. Herein, we develop and study a nanosized LiFePO 4 model system in which the electrolyte completely controls the electrochemical kinetics of the porous electrode. Impedance spectroscopy, cyclic voltammetry, and rate performance testing prove that ion transport in the electrolyte is the sole rate-limiting process, even in thin electrodes. A novel pseudo-steady-state extrapolation (S3E) method for Tafel analysis shows that LiFePO 4 obeys Butler-Volmer kinetics with a transfer coefficient of 3. The combination of these unexpectedly rapid interfacial kinetics and an activation barrier for phase transformation causes extreme reaction heterogeneity, which manifests as a moving reaction zone. Resistance versus capacity analysis enables direct measurement of electrolyte resistance growth during high-rate (dis)charge, revealing how the interaction between concentration polarization and a moving reaction zone controls electrolyte rate performance in LiFePO 4 electrodes. This work elucidates the profound impacts of the electrolyte on electrochemical measurements in porous battery electrodes: when the active material is not rate limiting, it is impossible to directly measure the intrinsic kinetics of the active material, but conversely, it becomes possible to directly measure the kinetics of the electrolyte.

Electrochemistry↗

Flexible PCB Windings Size Optimization for Winding AC Resistance Minimization Under the Sinusoidal Voltage Regime

In this paper, optimization of the winding AC resistance of the flexible printed circuit board (FPCB) wire windings is performed. A one-dimensional model of the FPCB winding is introduced and an equation for the FPCB winding AC resistance and its low and medium frequency approximation are derived. The approximate FPCB winding AC resistance equation is used to derive optimum thickness of the FPCB winding conductor thickness at which minimum of winding AC resistance (global optimum) is achieved. The Finite Element Method analysis and experimental verification of derived equations (winding resistance, impedance, power loss, and temperature measurements) is performed in order validate derived model and winding resistance equation.

42 ENGINEERING↗

Roadmap for the future of extreme wildfire events

Background Extreme wildfire events (EWEs) represent a growing threat globally, posing substantial risks to ecosystems, human communities, and infrastructure. Despite increased recognition of their ecological, social, and economic significance, current definitions of EWEs vary widely, reflecting disciplinary biases and regional contexts. This article emerges from an interdisciplinary workshop convened to reassess and refine the definition of EWEs, examine their impacts across ecological and social dimensions, and identify critical knowledge gaps impeding our understanding of these infrequent but important events. Results Our synthesis highlights significant limitations with existing definitions, particularly their reliance on subjective thresholds and their emphasis on extreme fire behavior alone. EWEs encompass a spectrum of complex, multi-dimensional phenomena that extend beyond immediate biophysical characteristics to include cumulative social, economic, and ecological impacts. These impacts often manifest over extended timeframes and include hazardous environmental contamination, severe geomorphic disturbances, ecosystem transformations, and unintended consequences of post-fire management actions. Current wildfire modeling frameworks inadequately capture these compounding factors, particularly the interactions among social systems, ecological conditions, and extreme fire behavior. To overcome these issues, we advocate for an interdisciplinary and context-sensitive approach to defining and studying EWEs. This revised definition emphasizes wildfires exhibiting anomalies in fire behavior, ecological outcomes, or social impacts relative to historically observed baselines, accommodating variability across different geographic regions and ecological settings. Conclusions Adopting an interdisciplinary framework that integrates biophysical and social sciences will enhance the predictive capability of wildfire models and improve resilience planning and response strategies. Filling identified knowledge gaps—such as limited high-quality empirical fire behavior data and insufficient integration of social dynamics into modeling—will better prepare communities and ecosystems to cope with and adapt to EWEs. This inclusive approach underscores the necessity for collaboration across disciplines and sectors, essential to managing extreme wildfires in an era of increasing climatic and ecological uncertainty.

54 ENVIRONMENTAL SCIENCES↗

Impact of Geomagnetic Induced Current Neutral Blocking Devices on Distance Relays in Sub-transmission Networks with IBR

Geomagnetically induced currents (GICs) can flow through transmission lines during geomagnetic disturbances, such as solar flares or coronal mass ejections. These currents can cause problems like transformer saturation and equipment damage. The most common method of mitigating GICs involves installing GIC neutral blocking devices (NBDs) in transformer neutrals. However, the wide application of capacitive GIC blocking devices may have unintended adverse effects on other devices, such as distance protection relays. As the number of inverter-based resources being connected to the transmission and sub-transmission systems increases, the likelihood of a sub-transmission line protected by a distance relay connected to a transformer with NBDs is increasing. Therefore, distance relays fed by IBRs and transmission lines with GIC-NBDs must be studied. This paper studies the effect of GIC-NBDs on a 69kV sub-transmission line of various lengths fed by a 25 MVA IBR and synchronous source. This work focused on the behavior of the GIC-NBDs using the measured apparent phase-to-ground and phase-to-phase impedance calculated by the relay and the source impedance ratio (SIR) during various electrical faults.

Patel, Trupal R [Sandia National Laboratories (SNL↗

Crosslinked Polyethyleneimine Gel Polymer Interface to Improve Cycling Stability of RFBs

Redox flow batteries are considered a promising technology for grid energy storage. However, capacity decay caused by crossover of active materials is a universal challenge for many flow battery systems, which are based on various chemistries. In this paper, using the vanadium redox flow battery as an example, we demonstrate a new gel polymer interface (GPI) consisting of crosslinked polyethyleneimine with a large amount of amino and carboxylic acid groups introduced between the positive electrode and the membrane. The GPI functions as a key component to prevent vanadium ions from crossing the membrane, thus supporting stable long-term cycling. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements were conducted to investigate the effect of GPI on the electrochemical properties of graphitic carbon electrodes (GCFs) and redox reaction of catholyte. X-ray photoelectron spectroscopy (XPS) and 1 H nuclear magnetic resonance (NMR) spectra demonstrated that the crosslinked GPI is chemically stable for 100 cycles without dissolution of polymers and swelling in the strong acidic electrolytes. Results from inductively coupled plasma mass spectrometry (ICP-MS), Fourier-transform infrared (FTIR) spectroscopy, and energy-dispersive X-ray (EDX) spectroscopy proved that the GPI is effective in maintaining the concentration of vanadium species in their respective half-cells, resulting in improved cycling stability because of it prevents active species from crossing the membrane and stabilizes the oxidation states of active species.

Lim, Hyung-Seok↗

Quantile regression-enriched event modeling framework for dropout analysis in high-temperature superconductor manufacturing

High-temperature superconductor (HTS) tapes have shown promising characteristics of high critical current, which are prerequisites for applications in high-field magnets. Due to the unstable growth conditions in the HTS manufacturing process, however, the frequent occurrences of dropouts in the critical current impede the consistent performance of HTS tapes. To manufacture HTS tapes with large scale, high yield, and uniform performance, it is essential to develop novel data analysis approaches for modeling the dropouts and identifying the related important process parameters. Conventional methods for modeling recurrent events, such as the point process, require the extraction of events from quality measurements. As the critical current is a continuous process, it may not comprehensively represent the drop patterns by transforming the time-series measurements into a set of events. Here, to solve this issue, we develop a novel quantile regression-enriched event modeling (QREM) framework that integrates the non-homogeneous Poisson process for modeling the occurrence of dropouts and the quantile regression for capturing the drop patterns. By incorporating the feature selection and regularization, the proposed framework identifies a set of significant process parameters that can potentially cause the dropouts of HTS tapes. The proposed method is tested on real HTS tapes produced using an advanced manufacturing process, successfully identifying important parameters that influence dropout events including the substrate temperature and voltage. The results demonstrate that the proposed QREM method outperforms the standard point process in predicting the occurrence of dropouts.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

Improved Characterization of Soil Organic Matter by Integrating FT-ICR MS, Liquid Chromatography Tandem Mass Spectrometry, and Molecular Networking: A Case Study of Root Litter Decay under Drought Conditions

Understanding of how soil organic matter (SOM) chemistry is altered in a changing climate has advanced considerably; however, most SOM components remain unidentified, impeding the ability to characterize a major fraction of organic matter and predict what types of molecules, and from which sources, will persist in soil. Here we present a novel approach to better characterize SOM extracts by integrating information from three types of analyses, and we deploy this method to characterize decaying root-detritus soil microcosms subjected to either drought or normal conditions. To observe broad differences in composition, we employed direct infusion Fourier-transform ion cyclotron resonance mass spectrometry (DI-FT-ICR MS). We complemented this with liquid chromatography tandem mass spectrometry (LC-MS/MS) to identify components by library matching. Since libraries contain only a small fraction of SOM components, we also used fragment spectral cosine similarity scores to relate unknowns and library matches through molecular networks. This integrated approach allowed us to corroborate DI-FT-ICR MS molecular formulas using library matches, which included fungal metabolites and related polyphenolic compounds. We also inferred structures of unknowns from molecular networks and improved LC-MS/MS annotation rates from ~5 to 35% by considering DI-FT-ICR MS molecular formula assignments. Under drought conditions, we found greater relative amounts of lignin-like vs condensed aromatic polyphenol formulas and lower average nominal oxidation state of carbon, suggesting reduced decomposition of SOM and/or microbes under stress. Our integrated approach provides a framework for enhanced annotation of SOM components that is more comprehensive than performing individual data analyses in parallel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the Effect of Electrolyte Additive Functionalities on NMC622/Si Cell Performance

Unstable electrode/electrolyte interface is the major cause of degradation for silicon (Si)-based anodes for lithium (Li)-ion batteries. Development of functional electrolyte additives can provide a viable path toward stabilizing the dynamic Si/electrolyte interface, which will benefit the development of high energy density Li-ion batteries. Here, we evaluate polymerizable electrolyte additives with varying functional groups (fluorocarbon, thiophosphate, and fluorophosphazene). The additives are examined using LiNi 0.6 Mn 0.2 Co 0.2 O 2 /Si full cells where the cycle performance and impedance are measured. Electrochemical tests show that the fluorine-containing additives provide better passivation at the Si electrode, leading to enhanced full cell performance. Here, among the three additives examined, best electrochemical performance is observed from the fluorocarbon-containing compound, followed by fluorophosphazene- and thiophosphate-containing compounds. Characterization of the solid electrolyte interphase (SEI) on cycled electrodes using Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS), and attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) reveal that higher concentration of fluorine and lithium oxide, and lower concentration of carbonate and organic species correlate with enhanced electrochemical performance.

25 ENERGY STORAGE↗

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays↗

Interface pinning causes the hysteresis of the hydride transformation in binary metal hydrides

Hydriding and dehydriding transitions in bulk and nanocrystalline binary metal hydrides were studied using the Pd-H model system by measuring pressure-composition isotherms with in situ x-ray diffractometry. Nanocrystalline Pd showed a smaller pressure hysteresis, solvus hysteresis, and hysteresis in lattice parameter, compared to bulk Pd. The time-dependence of pressure equilibration was measured after dosing with aliquots of hydrogen, giving equilibration times that were much faster in the single-phase regions than in the two-phase plateaus. In the broad two-phase plateaus, the pressure relaxations were exponential functions of time. An explanation of hysteresis is developed that is based on a dissipative potential barrier that impedes the motion of the interface due to interactions between lattice defects and the two-phase interface. The exponential pressure relaxations and hysteresis are consistent for this mechanism. For a simple model of the pinning potential, the potential barrier maximum is an order of magnitude less than typical grain boundary energies. These pinning effects are substantially different in the nanocrystalline Pd, suggesting differences in the hydriding mechanism.

36 MATERIALS SCIENCE↗

Mechanistic insights into sulfate and phosphate-mediated hexavalent chromium removal by tea polyphenols wrapped nano-zero-valent iron

Nano zero-valent iron via green synthesis (g-nZVI) has great potential in removing toxic hexavalent Cr(VI) from industrial wastewater. Sulfate and phosphate in wastewater can influence Cr(VI) removal by g-nZVI. Here, in this study, the Cr(VI) removal kinetics by different g-nZVI materials were investigated with the existence of sulfate and/or phosphate, and the corresponding mechanisms were first revealed using multiple characterizations, including X-ray absorption near-edge spectra (XANES) and X-ray photoelectron spectroscopy (XPS). The results showed that Cr(OH) 3 was the dominant species initially formed on the surface of g-nZVI particles before transforming to Cr 2 O 3 during the reaction of g-nZVI with Cr(VI). Sulfate in wastewater can promote the reduction from Cr(VI) to Cr(OH) 3 by g-nZVI, because sulfate triggers the release of Fe(II) and tea polyphenols (from tea extracts) from the g-nZVI surface due to the corrosion of Fe 0 core, which is in line with an obvious increase in pseudo-second-order rate constant (k 2 ) and subtle change in Cr(VI) removal capacity (q e ). However, phosphate impedes the g-nZVI corrosion and inhibits q e because of the inner-sphere complexation of phosphate onto g-nZVI decreasing the released Fe(II) for Cr 2 O 3 production. When sulfate and phosphate coexisted in contaminated water, the inhibition effect of phosphate in Cr(VI) removal by g-nZVI was stronger than the promotion of sulfate. Accordingly, q e value of g-nZVI declined from 93.4 mg g –1 to 77.5 mg g –1 , while k 2 remained constant as the molar ratio of phosphate/sulfate increased from 0.1 to 10 in water. This study provides new insights into applying g-nZVI in efficient Cr(VI) removal from contaminated water with enrichment of sulphates and phosphates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementing Admittance Relaying for Microgrid Protection

An earlier study evaluated issues with microgrid protection. This highlighted the difficulties with microgrid protection, which include: 1. lack of fault current from inverter-interfaced generation, 2. varying fault current between grid-connected and islanded modes, 3. potential for normally-meshed operation and 4. unbalanced operation due to single-phase loads. It is worth noting that not all microgrid designs will include all these challenges. For example, microgrids could choose to omit meshed operation. Previous work identified differential protection based on the discrete S-transform for line protection and admittance protection for load protection as possible solutions . However, some severe limitations were identified. This included the potential for blinding of the discrete S-transform protection when fault contribution on either end of the line is similar, and loss of protection selectivity for admittance protection in the case of upstream line-ground faults. This report investigates admittance protection as a solution for line and load protection in greater detail by comparing analytical and simulated results. Section 2 describes the protection schemes analyzed and the behavior of inverter-interfaced microgrids under faults in more detail. Section 3 derives sequence networks for the fault cases considered. Section 4 presents a transient model constructed to validate the impedances calculated from the sequence networks. Section 5 compares the results from the sequence networks and transient model. Last, Section 6 presents the conclusions of this study in terms of the suitability of admittance relaying for protection of inverter-interfaced microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transforming an Ionic Conductor into an Electronic Conductor via Crystallization: In Situ Evolution of Transference Numbers and Structure in (La,Sr)(Ga,Fe)O 3–x Perovskite Thin Films

Mixed-conducting perovskites are workhorse electrochemically active materials, but typical high-temperature processing compromises their catalytic activity and chemo-mechanical integrity. Low-temperature pulsed laser deposition of amorphous films plus mild thermal annealing is an emerging route to form homogeneous mixed conductors with exceptional catalytic activity, but little is known about the evolution of the oxide-ion transport and transference numbers during crystallization. Here the coupled evolution of ionic and electronic transport behavior and structure in room-temperature-grown amorphous (La,Sr)(Ga,Fe)O 3-x films as they crystallize is explored. In situ ac-impedance spectroscopy with and without blocking electrodes, simultaneous capturing-synchrotron-grazing-incidence X-ray diffraction, dc polarization, transmission electron microscopy, and molecular dynamics simulations to evaluate isothermal and non-isothermal crystallization effects and the role of grain boundaries on transference numbers is combined. Ionic conductivity increases by ≈2 orders of magnitude during crystallization, with even larger increases in electronic conductivity. Consequently, as crystallinity increases, LSGF transitions from a predominantly ionic conductor to a predominantly electronic conductor. The roles of evolving lattice structural order, microstructure, and defect chemistry are examined. Grain boundaries appear relatively nonblocking electronically but significantly blocking ionically. The results demonstrate that ionic transference numbers can be tailored over a wide range by tuning crystallinity and microstructure without having to change the cation composition.

36 MATERIALS SCIENCE↗